| 1 | Building Items (Part A) |
| 2 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding NOld work (one or more coats) including scrapping surface and necessary repairs. (a) Colour Change r |
| 3 | Applying one coat of Cement primer of approved brand and manufacture on wall surface including all scaffolding: |
| 4 | Painting exterior surface of wall with 100% acryic exterrior paint of approved brand and manufacture to give an even shade with two or more coats including prepartion of base with sand parering prime putty etc complete in all respect New work |
| 5 | Painting with enamel paint of approved brand and manufacture to give an even shade : One or more coats on old work. |
| 6 | Painting with enamel paint of app brand and manufacturer to give an even shade two ro more coat on new work |
| 7 | Plaster on new surface on walls in cement sand mortar 1 : 6 including raking of joints etc. complete fine finished : 20 mm thick |
| 8 | P & F 1st qualityVitrified Porcelain Polished tiles on floor, skirting and steps etc.in different sizes (thickness to be specified by manufactuer) with water absortion less than 0.08% and conforming to IS 15622 of pproved make in all colour and shade, laid with 20 mm thick CM 1 : 4 includinggrounting the joints with white cement and matching pigment etc complete.size 600 mm X 600 mm |
| 9 | Add extra for Fixing glazed/ Ceramic/ Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477 , using 5kg. adhesive per sqm of tile area, in average 3mm thickness instead of cement mortar. |
| 10 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, making of lines or groove etc complete but excluding the cost of nosing of steps etc. complete. 75mm thick with 20mm thick nominal size aggregate |
| 11 | Labour charges for repair to door / window without using any material such as applying randha (finishing) tightening of bolts& screw etc |
| 12 | Providing and Fixing2nd ist quality standard white/ivory, grey, fuma red brown, light green, light blue and other light shades glazed tiles of ISI marked (IS:13753) of size 300 mm x 200 mm in walls, floors, steps, pillars etc. laid on a bed of neat cementslurry finished with flush pointing in white cement mixed with pigment to match the shade of tile complete (excluding the cost of cement plaster on walls & pillar): Category - A kajaria, jhonson, somnani make etc. |
| 13 | Providing and fixing iind quality MAT finished ceremic tiles size 300x300 mm confirming to IS 13753 colour such as white, grey, lvory, fume red brown in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry including nicely finished joints using water proof joint filler powder (untile or roffe make)and finishing with flush pointing in white cement mixed with pigment to match the shade of tile complete (including the cost of cement mortar bed 1:4). 20mm thick |
| 14 | Providing and applying white cement based putty over plastered surface to prepare the surface even and smooth complete New Plastered Surface (three or more coats) |
| 15 | Renewing glass panes, with putty and nails whenever necessary : Float glass panes of thickness 4 mm |
| 16 | Providing and fixing curtain rods of 1.25 mm thick chromium plated brass plate, with two chromium plated brass brackets fixed with C.P. brass screws and wooden plugs, etc., wherever necessary complete: 20mm |
| 17 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting (height upto 10 m) , fixing in position and applying a priming coat of approved steel primer all complete: |
| 18 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M20 grade Nominal Mix1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone |
| 19 | Kota stone slab flooring 25 mm thick over 20 mm (average)thick base laid over and jointed with grey cement slurrymixed with pigment to match the shade of the slab includingrubbing and polishing complete with base of cement mortar 1: 4 (1 cement : 4 coarse sand)For area of each slab from 2001 to 5000 Sq.Cm |
| 20 | Random Rubble stone masonry with hard stone insuperstructure above plinth level and upto five level above30cm. thick walls in Cement Mortar 1:6 ( 1-Cement : 6-Sand): |
| 21 | Half brick masonry in Superstructure , above plinth level uptofloor V level using bricks of designation 75Cement mortar 1 : 6 (1 cement : 6 coarse sand) |
| 22 | Earth work in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms, lift up to 1.5 Mtr. including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soil |
| 23 | Providing and laying in position cement conrete including curing compaction etc. Complete in specified grade excluding the cost of centering and shuttering. All work up to plinth level 1:4:8 (1 cement: 4 coarse sand:8 graded stone aggregate 40 mm nominal size) |
| 24 | Random Rubble stone masonry for foundation and plinth in Cement Sand mortar above 30CM thick wall in: Cement Mortar 1:6 ( 1-Cement : 6-Sand). |
| 25 | Providing and fixing of double leaf steel shutter for cupboard, the frame is made of pressed steel ISI section 80x25 mmx1.25 mm thick with 1.00 mm MS sheet to spot welded including holdfasts of 15x3mm, MS oxidized fittings such as butt hinges, sliding doors bolts, handles, tower bolts and twinpeg etc complete including applying priming coat of approved steel primer of red oxide zinc chromate and spray painting inapproved shade with deco paint of approved quality complete as per direction of Engineer In Charge |
| 26 | Repair of door, window shutters including cost of material and labour for change of damaged :Panel by Shuttering Ply - 9mm thick (Commercial) |
| 27 | Repair of door, window shutters including cost of material and labour for change of damaged :Panel by Wire Gauge 14 mesh x 24 gauge |
| 28 | Repair of door, window shutters including cost of material and labour for change of damaged :Panel by Plain Glass Panes 4mm thick |
| 29 | Repair of door, window shutters including cost of material and labour for change of damaged :Aldrop of mild Steel12\" long x12mm dia |
| 30 | Repair of door, window shutters including cost of material and labour for change of damaged :Stopper of Aluminium with Double Rubber Gutka |
| 31 | Providing and fixing welded mesh/expanded metal mesh in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. complete (excluding frame work) of sizeWelded mesh 50 mmx 50 mm x 2.1 mm. |
| 32 | Supplying and fixing in walls machine cut and polished stone shelves, tands and in CM 1:3 with machine cut edges :Kota stone minimum 30mm thick. |
| 33 | Providing and fixing T-iron frames for doors windows and ventilators of mild steel Tee-sections, joints mitred and welded with 15x3 mm lugs: 10 cm long embedded in cement concrete blocks 15x10x10cm of 1:3:6 (1 cement:3 coarse sand:6 graded stone aggregate 20 mm nominal size)or with wooden plugs and screw or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. |
| 34 | Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section (IS 1038- 1983) joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer,excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required :Windows side hung /Ventilators top or centre hung (openable)Deduct for Pin headed 4mm thick glass panels is used insteadof 4mm thick plain glass |
| 35 | Supplying and fixing fixed wire gauge of 14 mesh x 24 gaugeto the metal frame of rolled section by metal beading 20x3mmwith suitable screw at not exceeding 150mm distance |
| 36 | Providing and fixing Square bars or other flat welded to window, ventilatiors etc. |
| 37 | Providing and fixing M.S. sheet 1mm thick single leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint Add extra for double leaf shutters |
| 38 | Finishing with neat cement (punning). |
| 39 | Patch repair to cement concrete floor including digging out old floor in regular shape and removal of rubbish curing etc. complete in all respects. |
| 40 | Removal and refixing stone chhajja 50 to 75 mm thick including finishing, complete in all respects. |
| 41 | Repair to stone masonary in cement sand mortar 1:6 with old and new stone. |
| 42 | Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster incl. disposal of rubbish to the dumping ground within 50mtr lead |
| 43 | Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge:In cement mortar. |
| 44 | Making holes in stone masonry wall upto 450 mm x 450 mm size and making good in CM 1:6. |
| 45 | Providing and fixing bright finished Mortice lock of approved make Godrej or equivalent with pair of CP handles for doors with necessary screws etc complete (Best make of approved quality) as per direction of Engineer-in-charge. |
| 46 | Supplying and fixing in walls machine cut and polished stone shelves, tands and in CM 1:3 with machine cut edges :Sand or other approved stone 50mm thick. |
| 47 | Providing & fixing external grade board solid core single lef flush door shutters ISI 2200-67 mark using phenol formal dehyderesin in glue both sides with approved steel fittings complete as per annexure 30 mm thick .Commercial Veneer both side |
| 48 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
| 49 | Providing and fixing horizontal chajja of Red/ White sand stone 40 mm thick and upto 80 cm projection in cement mortar 1:4 (1 cement : 4 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade. |
| 50 | Sanitary Items (Part-B) |
| 51 | P & F Indian type white glazed vitreous china I st quality W.C. Orissa pan (I.S. : 2556 Mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor. Size 580 X 440 mm |
| 52 | P & F WVC wash basin (Ist quality, I.S. : 2556 Mark) of approved make with C.I. brackets duly painted I No 15 mm C.P. pillar cock (I.S. : 8934 Mark) & 32 mm C.P. Brass waste coupling of approved make 25 mm G.I. waste Pipe complete including cutting & making good the wall. & Floor Size 510 X 400 mm. |
| 53 | P & F Looking Mirrors with P.V.C. frame of approved make as per direction of Engineer-in-charge Size 500x400mm |
| 54 | P & F full way valve (IS 778 mark) or wheel valve of app make gunmetal 15 mm nominal bore |
| 55 | P & F full way valve (IS 778 mark) or wheel valve of app make gunmetal 25 mm nominal bore |
| 56 | P & F PVC Storage Tank ISI Marked (IS : 12701) indicating the BIS license No), of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design 500 litres capacity. |
| 57 | P & F waste coupling with fitting of approved quality / make : C.P. Brass 32 mm dia |
| 58 | P & F waste pipe with all fitting : PVC with PVC with cp nut 32 mm |
| 59 | P & F flush/ flush Cock valve (IS 9758 mark) for WC to app quality / make brass/ gun metal half turn wt 1 Kg of quality/make 25 mm nominal bore |
| 60 | P & F Grating of app quality / make stainless steel size 125 mm dia |
| 61 | P & F Bib cock (IS 8931 mark) superior quality of app make Brass 400 gm 15 mm nominal bore |
| 62 | P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Gyser etc. C.P. Inlet connection 15mm.Brass (IS : 8931 marked) |
| 63 | Providing & Laying C.C. 1:5:10 (Stone aggregate 40mm nominal size) upto haunches of S.W. pipes including 150 mm thick bed concrete (Width W= Dia of pipe in Cm+ 30Cm.) concrete width to be reduced from width W at center of pipe to `0` at top of pipe. (Excluding cost of pipe) 100mm dia S.W. pipe |
| 64 | P & F Bib cock (IS 8931 mark) superior quality of app make C P Brass 15 mm |
| 65 | P & F Stop cock (IS 8931 mark) superior quality of app make Brass 400 gm 15 mm nominal bore |
| 66 | P & F Ball Cock (IS :1703 Mark) with Rod & P.V.C. Ball complete :Brass wt. Not less than 300 gm,15mm |
| 67 | P & F GI pipes (internal work) with fitting (IS 1239 mark) & MS clamps incl cutting & making good the walls & floor (a) exposed on wall 15 mm dia nominal bore B class |
| 68 | P & F GI pipes (internal work) with fitting (IS 1239 mark) & MS clamps incl cutting & making good the walls & floor (a) exposed on wall 25 mm dia nominal bore B class |
| 69 | P & F GI pipes ( External works ) with GI fittings eccluding Union (IS:1239 mark ) and MS clamps, including trenching and refilling earth etc.15 mm dia nominal size B class |
| 70 | P & F GI pipes ( External works ) with GI fittings eccluding Union (IS:1239 mark ) and MS clamps, including trenching and refilling earth etc.25 mm dia nominal sizeB class |
| 71 | P & F Square-mouth gully trap `A` grade (IS 651-1992 :marked) of approved make complete with C.I. grating, frame & Cover masonary chamber in C.M. 1:6, 100mm thick C.C. 1:5:10 base concrete, 40mm thick C.C.M-15 grade coping, 12mm thick cement plaster in CM 1:3 complete as per approved design & type. 3.5.1 Trap size 150 X 100mm, ferrow cement cover with frame, Internal Chamber size 300 X 300mm |
| 72 | Construction of chamber in all type of soil with 300 mm thick masonry in CM 1:6 100 mm thick C.C. 1:5:10 in foundation, 20 mm thick inside plaster in Cm 1:6 finished with floating neat cement, 50 mm thick M-154 grade C.C. flooring, earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtr. Inside 300 X 300 mm depth up to 0.5 M & 5 kgs of cement cover with frame |
| 73 | Construction of manhole in all type of soil inner size 90 X 60 cm 450 mm thick masonry in CM 1:6 m 10 cm thick C.C. 1:5:10 in foundation, 20 mm thick inside plaster in Cm 1:6 finished with floating neat cement, 50 mm thick M-15 grade C.C. flooring, making channels 80 mm thick stone slab covering with 40 mm thick M-15 grade CC floor cement cover with frame of 450 mm dia earth work etc. complete as per design incl disposal of surplus earth within 50 mm lead. Depth up to 0.5 m |
| 74 | P & F rigid PVC pipe (IS 4985 mark) class 11/4 kg/cm 2) appd quality/ make incl jointing the pipe with solvent cement rubber ring & lubricant (B) 110 mm dia |
| 75 | P & F rigid PVC pipe fitting (IS 4985 mark) appd quality/ make incl jointing the pipe with solvent cement rubber ring & lubricantBend 87.5 110mm |
| 76 | P & F rigid PVC pipe fitting (IS 4985 mark) appd quality/ make incl jointing the pipe with solvent cement rubber ring & lubricant Vent cowel 110mm dia mm |
| 77 | P & F rigid PVC pipe fitting (IS 4985 mark) appd quality/ make incl jointing the pipe with solvent cement rubber ring & lubricant Door Tee 110 Mm |
| 78 | P & F 15 mm dia connection pipe of appd quality / make PVC pipe with CP Brass nuts up to length 450 mm |
| 79 | P & F water closet seat covers with brass hinges complete : Solid PVC (ISI marked) grade-1 white for EWC |
| 80 | P & F European type white glazed vitreous china 1 st quality W.C pan (IS : 2556 Mark) with P or S trap including cutting and making good the wall and floor |
| 81 | P & F jet spray for water closet with CP copper tube flange of approved make |
| 82 | P & F C.P. Health Faucet with 1Mtr. Long Tube & Hook of approved make and heavy as per direction of Enginner-in-Charge |
| 83 | P & F low level Flushing Cistern of 10 liters capacity 9IS:2556 mark), of approve make with complete fittings CI brakets duly painted, brass ball cock with ball, (IS: 1703 mark) complete including cutting and making good the wall: PVC with PVC bend as per IS 7231 |
| 84 | Supply & fixing G.I. Union ISI marked in G.I. pipe line asrequired complete in all respect of size :2.32.1 15mm dia nominal bore |
| 85 | Supply & fixing G.I. Union ISI marked in G.I. pipe line asrequired complete in all respect of size 25 mm dia nominal bore |
| 86 | Electric (Part C) |
| 87 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) on surface ISI marked ( IS:14927 P - II ) virgin material UPVC trunking & it\"s accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal/ Surface Moulded virgin material UPVC Modular Box , 10 A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose/holder /3 way Connector, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet\"s & Electrical/ Wiring ccessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR (A) short point (up to 3 mtr.) |
| 88 | (B) Medium point (up to 6 mtr.) |
| 89 | Long point (upto 10mtr.) |
| 90 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR 2 x 1.5 sq.mm |
| 91 | BSR 2 x 2.5 sq. mm. + 1x1.5sqmm |
| 92 | P & F ISI marked (IS:3854) 6 amp. flush type non modular switch with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material including cutting hole in tile and making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . |
| 93 | Providing & Fixing of of 3/5 pin 6 amp. flush type non modular socket made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal with Porcelain based back cover & captive screws including cutting hole in tile and making connection testing etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attachedwith this BSR |
| 94 | Providing & Fixing of Recessed/surface mounting heavy duty Enclosure made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted complete with din rail making internal DB terminations with copper lugs, detachable gland plate, including making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure \"A\" attached with this BSRSuitable for Six / Eight module for MCB/ RCCB |
| 95 | Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR 6 A to 32 A rating |
| 96 | Providing & Fixing of 240/415 V isolator ISI marked IS:13947-III/conforming to IEC 60947-3, suitable for AC22A utilization category, 4KV impulse withstand voltage, true contact indication, Red colour dolly / lever shall have single mould covering over all poles for operation , two position din rail mounting, minimum phase termination capacity of 35sq.mm. IP 20 contact protection and fitted in existing distribution board / sheet including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR30 A / 40 A rating |
| 97 | Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printed made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , including all as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR 5 step fan regulator 2 Module 360 dgree rotating |
| 98 | Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost of ISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification of Wiring accessories refer Chapter E - 07 related item & For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 99 | Providing & Fixing of energy efficient direct fit (Retrofit) Polycarbonate/ Glass housing SMD Mid Power LED tube rod (with integral driver & alumn. heat sink ), on existing fixture. system lumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.≥0.95,CRI >80 , life time of minimum 35000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .1200mm , Min. Lumens output 2000 lm LED Tube rod with Polycarbonate Housing |
| 100 | Providing & Fixing of BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan Conforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR 1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) |
| 101 | Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / Sqaure SMD Mid Power LED Downlight with power coated die-cast aluminum housing with UV Stabilized non yellowish Diffuser with BIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80, life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .Recessed MountingMinimum lumen output 1950 lm |
| 102 | Providing & Fixing of Heavy duty capacitor start, copper wound Double ball bearing 900/1400 RPM single phase Exhaust fan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . Please Enable Macros to View BoQ information |