| 1 | 1.0)Running Maintenance & Operation of Internal electrical installation of staff quarter by providing following staff: |
| 2 | 1.1) Wireman Gr-II -1 No. (General shift) |
| 3 | 1.2) Khallasi -1 No. (General shift) |
| 4 | 2.0) Rewiring for light point/ fan point/ exhaust fan point/call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.(Group- B) |
| 5 | 3.0)Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. As required. |
| 6 | 3.1) 5/6 A switch |
| 7 | 3.2)15/16 A switch |
| 8 | 3.3)3 pin 5/6 A socket outlet |
| 9 | 3.4)6 pin 15/16 A socket outlet |
| 10 | 4.0)Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 11 | 5.0) Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 12 | 5.1)Single pole |
| 13 | 5.2) Double pole |
| 14 | 5.3) Triple pole |
| 15 | 6.0) Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. As required. a) 63 A |
| 16 | 7.0) Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 17 | 7.1) 1 x 1.5 sq. mm |
| 18 | 7.2) 3 x 1.5 sq. mm |
| 19 | 7.3) 3 x 2.5 sq. mm |
| 20 | 7.4) 3 x 4 sq. mm |
| 21 | 8.0)Repairing/ replacement of defective/ wornout parts like coil & thermostat of existing Geyser in different location at above said site i/c connection testing etc required. |
| 22 | 9.0)Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. As required. |
| 23 | 9.1)1 or 2 Module |
| 24 | 9.2)3 Module |
| 25 | 9.3)4 Module |
| 26 | 9.4)6 Module |
| 27 | 9.5)8 Module |
| 28 | 9.6) 12 Module |
| 29 | 10.0)Annual comprehensive maintenance & servicing of CATA-C Chimney at Staff Quarters i/c rewinding of fan motor, replacement of indicating lamps & switches, fan blades etc. and servicing of chimney with the help chemical once in a year and as & when required at site. |
| 30 | 11.0)Brush Less Direct Current (BLDC) Fan without RemoteSupply, Installation, Testing and Commissioning (including deduction of cost for replaced item) of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. (a) 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 31 | 12.0)Supply and replacement of capacitor of following capacityetc. as required. |
| 32 | 12.1) 3.15 MFD for exhaust fan |
| 33 | 12.2) 2.5 MFD for ceiling fan |
| 34 | 13.0) Rewinding of 48\" ceiling fan oiling, greasing servicing, cleaning dismantaling and re- assembling along with replacement of bearings, testing, commissoning etc. as required. |
| 35 | 14.0) Supply & replaacement of ball bearing pf 48\"\"/56\"\" ceiling fan i/c testing etc. complete as required. |
| 36 | 15.0)Supply and Replacement of Chimney size 3ft (90 cm) made with high-grade stainless steel, The chimney have Mechanical control panel, 3 Extraction level, Maximum air flow-1000 m3/hr, maximum energy cunsumption-270W, Dishwasher- washable filter, max- pressure-430 Pa, minimum sound power-56dB(A), Maximum: 70 DB (A) i/e testing commissioning etc. complete as required |
| 37 | 16.0) Installation, Testing and Commissioning of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. As required.(a) Upto 450 mm sweep |
| 38 | 17.0) Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. |
| 39 | 17.1) 1 or 2 Module (75mmX75mm) |
| 40 | 17.2) 3 Module (100mmX75mm) |
| 41 | 17.3) 4 Module (125mmX75mm) |
| 42 | 17.4) 6 Module (200mmX75mm) |
| 43 | 17.5) 8 Module (125mmX125mm) |
| 44 | 17.6) 12 Module (200mmX150mm) |