Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Demolition ofbrick work built in cementmortar incl all arches, pillars etc but excluding ashlar facings dressed stone quoins work ,complete all as specified and directed. |
| 2 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fitting and accessories) ,complete all as specified and directed. |
| 3 | Taking down cement plaster on brick or stone walls, etc.including raking out joints, hacking for key, scrubbing down with water, etc ,complete all as specified and directed. |
| 4 | S&F MS bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required; hooks (stay), heavy, for large gates; hook and pintle hinges; largehasps and staples; chains; hand made sliding bolts; clamps; hold fasts; will ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe410-0 or Fe 310-0,complete all as specified and directed. |
| 5 | S & F 160mm bore PVC (SWR) pipessingle socketed in any length with rubber ring jointsfixed to walls,complete all as specified and directed. |
| 6 | S&F PVC SWR bends any radius of size 160mm bore,complete all as specified and directed. |
| 7 | M&L for Brick work with sub-class `B\" bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:4,complete all as specified and directed. |
| 8 | M&L forcement concrete type B-1, 1:2:4 (using 20 mm graded stone aggregate) as in coping, bed platesetc complete all as specified and as directed |
| 9 | M&L for Rendering 15mm thick on fair faces of brick work or concrete surfaces finished even in CM (1:6) complete all as specified and as directed. |
| 10 | M&L for Rendering 15mm thick on fair faces of brick work or concrete surfaces finished even in CM (1:4) with WPC complete all as specified and as directed. (WPC measured and paid saperatly). |
| 11 | Supply only water proofing compound,complete all as specified and directed. |
| 12 | M&L for preparation of newly plastered surfaces of wall and applying two coat of white wash complete all as specified and as directed. |
| 13 | M&L applying two coats of acrylic exterior weather proof emulsion paint over a coat of exterior primer on newly plastered wall surfaces/complete all as specified and directed. |
| 14 | M&L for two coats of distemper oil emulsion over old plastered surfaces of wallincluding preparation of surfaces complete all as specified and directed. |
| 15 | M&L for preparation of old decorated surfaces of wall and applying two coat of white wash complete all as specified and as directed. |
| 16 | M&L forComplete Removal of existing treatment including preparation of old treated surface andapplying two coats of acrylic exterior weather proof emulsion paint over a coat of exterior primerold decorated wall surfaces, complete all as specified and directed. |
| 17 | M&L for Preparation of Newly Plastered surfaces of Wall and applying Two coats of Oil Bound Distemper over a coat of primer,complete all as specified and directed. |
| 18 | M&L Preparation of Newly Plastered surfaces of Ceiling and applying Three coats of White Wash complete all as specified and directed. |
| 19 | M&L 5mm thick rendering in CM 1:3 on ceiling surfaces even and smooth without using extra cement complete all as specified |
| 20 | M&L for preparation of old plastered surfaces of ceilings and apply one coat of white wash complete all as specified and directed. |
| 21 | M&L for preparation of newly steel surfaces of any description over 10 cmin width or girth not otherwise described and applying two coats of synthetic enamelpaint over a coat ofred oxide primer complete all as specified and directed. |
| 22 | M&L for preparation of old steel surfaces of any description over 10 cmin width or girth not otherwise described and applying two coats of synthetic enamelpaint over a coat ofred oxide primer complete all as specified and directed. |
| 23 | Preparation of new steel surface any description, nexc10cm in width or girth not otherwise described applying two coats of synthetic enamel paint over a coat ofred oxide primer |
| 24 | S&F 20mm thick hardwood 2nd class boarding plain on both side butt joint & fixed with screw complete all as specified and directed. |
| 25 | Preparation of old steel surface any description, nexc10cm in width or girth not otherwise described applying two coats of synthetic enamel paint over a coat ofred oxide primer |
| 26 | M&L for Preparation of new wood surfaces of any description,not otherwise,described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 27 | M&L for preparation of old painted surfaces of wood and wood based surfaces of any description, over 10 cm in width or girth and apply one coat of synthetic enamel paint complete all as specified and directed. |
| 28 | M&L for scrapping out loose mortar/ concrete by chiseling/wire brushing complete and applying rust removing solution (rebaklene solution) to exposed corroded reinforcement and applying a coat of epoxy primer (Nitozink primer from M/s Fosrock or equivalent as approved by GE) as per manufacturers instructions and fixing of hard drawn steel wire fabric (Hard drawn steel wire fabric measured & paid separately) and apply 25 mm average thickness in cement concrete type B0 1:2:4 (using 12.5 mm graded stone aggregate) mixed with liquid integral water proofing compound (WPCmeasured & paid separately) etc. complete all as specified and directed. |
| 29 | M&L for providing precast cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate for landings, cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces,complete all as specified and directed. |
| 30 | S&F TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. |
| 31 | Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0,complete all as specified and directed. |
| 32 | Hard drawn steel wire fabric cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm in dia supplied and fixed in reinforcement |
| 33 | S&F for 25mm dia Stainless Steel Curtain Rod with brackets incl T/D of any type old curtain rods complete all as specified and directed |
| 34 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off premises complete all as specified and directed |
| 35 | M & L coloured vitrified tiles Light shade 10 mm thick (square/rectangular) polish area of each tiles n exc 0.36 Sqm coloured cut to required size set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles as in floor incl 15 mm thick screed bed in CM 1:4 complete all as specified and directed. |
| 36 | M & L coloured vitrified tiles 10 mm thick (square/rectangular)polish area of each tiles n exc 0.36 Sqm coloured cut to required size set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles but in vertical surfaces incl 10 mm thick rendering in CM 1:3 complete all as specified and directed. |
| 37 | Taking down chowkhat or frames n exc 1.50 Sqm each with shutters (without taking off shutters from the frame) and removing to or from store complete all as specified and directed |
| 38 | Taking down chowkhat or frames exc 1.50 Sqm and n exc 4 Sqm each with shutters (without taking off shutters from the frame) and removing to or from store complete all as specified and directed |
| 39 | S&F Powder coated Aluminium anodised glazed side hung door shutters with anodised aluminium frame of section of 100x44x2mm and bottom rail of 44.5x99x1.8mm including 5.5mm thick tinted sheet glass ordinary quality with all necessary suitable push & pull plate/handle , screw, jointing cleats, rubber packing aluminium snap beading and 1 No 200mm long Aluminium tower bolt, 100mm long 3 No Aluminium butt hinges B-21 Type and one No mortice brass lock 100 size 4 leaver (Vertical Type) with 01 No door closer Aluminium (Diie cast) body hydraullically regulated designation ;No 02 universal type, for each shutters,complete all as specified and directed. |
| 40 | S&F Second class hard wood (Sal) plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed. |
| 41 | S & F 35 mm thick second class hard wood rail and style plain, framed, factory made panelled shutters (Two panels) with lock rail and panel of 9 mm thick BWP commercial ply or 12 mm thick veneered particle board with commercial veneering on both faces. The size of rail and stiles are as per IS – 1003 (Part – I), kiln seasoned & chemically pressure treated complete all as specified and directed. |
| 42 | S&F in repair 100 mm long butt hinges extruded aluminium alloy with galvanised mild steel hinge pin anodised type B-21 complete all as specified and directed. |
| 43 | S&F in repair 250 mm long aluminium alloy, anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloycomplete all as specified and directed. |
| 44 | S&F in repair floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring fixed in floor, over all length of cover plate 150 mm complete all as specified and directed. |
| 45 | M&L for preparation of new or previously untreated surfaces of wood and wood based surfaces of any description, over 10 cm in width or girth and apply two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 46 | S&F in repair 300 mm mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed. |
| 47 | S&F powder coated anodised aluminium sections of required size for door windows frames ventilator with one or more rebates includingof required size jointing cleats, screws sash fasteners, rollers to move shutters,plug for fixing with walls, columns etc complete all as specified and directed. |
| 48 | S&F powder coated anodised aluminium windows and ventilators shutters,side hung type, without sash bars, aluminium sections weighing 0.55 kg /m incl neccessaryjoining cleats , glazing clips , rubber packing , anodised aluminium snap beading ,screws, rollers and locking assembly, annodised aluminium fiting such as peg stays 150 mm long (1 Nos). hinges type B-21 100 mm long (2 Nos) suitable handle (1 Nos),complete all as specified and directed. |
| 49 | S&F 5.5 mm thick coloured sheet glass, selectedquality and glazing with clips etcin square in exc 0.5 sq.m in each pane,complete all as specified and directed. |
| 50 | S&F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples,complete all as specified and directed. |
| 51 | S&F in repair double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty complete all as specified and directed. |
| 52 | S&F in repair door closer hydraulically regulated designation No 2, universal type, suitable for door shutter of weight not more than 60 Kg of aluminium (extruded section body) complete all as specified and directed. |
| 53 | Taking down existing water proofing treatment/membrane of any type and Cleaning the surface of roof, palstered surfaces etc by roughening, picking, sweeping clean and washing down with water to remove all loose dirt etc and preparing the surface to receive plaster and brushing neat cement slurry @ 3.00 Kg of cement per Sqm complete all as directed by Engr-in-Chrg |
| 54 | M&L Water proofing treatment on \"Non approachable / non accessible and approachable roof\" surface (Horizontal & Vertical surfaces) in following sequence through manufacturer / authorized applicator of the manufacturer including taking down of existing roof treatment,properly cleaning & drying the concrete surfaces complete (i) Applying a coat of oxidised bitumen based solvent primer @ 0.3 Kg / Sqm(ii)Applying evenly a tack coat of industrial bitumen 85/25 grade @ 1.2 kg/ Sqm incl cleaning surfaces complete all as specified and directed. (iii) Laying evenly over the bitumen coated surface, polymeric water proofing membrane Hyperplas standard wt not less than 3kg /Sqm with 100 mm over laps shall be sealed by flame as per manufacturers instruction complete all as specified and directed.(iv) Applying two coats of bituminous aluminium paintincluding preparation complete all as specified and directed. |
| 55 | M&L for PCC 1:2:4 type B0 (Using 12.50mm gradedstone aggregate) in roof padding/ kerbs/ sunken slab etc complete all as specified and directed. |
| 56 | M&L10 mm thick rendering on roof surfaces/ concrete surface in CM 1:4 with liquid water proofing compound @ 200 ml per 50 Kg cement complete all as specified and directed. (Waterproofing compound should be measured and paid separately). |
| 57 | Supply only water proofing compound (liquid), ISI marked complete all as specified and directed. |
| 58 | Demolition of Cement Concrete (unreinforced) of any description & in any position not otherwise specifically provided for complete all as specified & directed. |
| 59 | M&L for Removing Demolished material exc. 250 m but n exc. 500 m anddepositing where directed complete all as specified and directed. |
| 60 | M&L for Making corner fillets with Polymer modified cementitious (PMC) mortar (PMC:C:M :: 1:2:4 by weight) at all joints of horizontal and vertical surface and doing bore packing with PMC mortar complete all as specified and directed. |
| 61 | Taking down carefully copper/aluminium point wiring (light,fan,bell, socket or power)complete,including fixtures and fittings such as switches, ceiling roses, holders,regulators, sockets, tube light fittings i.e removingmaterials to store forkeeping in safe custody or for taking credit (credit for above items should be made for conditions separately )and including making good the disturbed surfaces to match with existing surface and colour shade with proper puttyfor smooth finishing without andulations complete all as specified and directed.( Note:-All credit materials should be deposited in MES yard as available on work site the same materials should be issued to contractorthrough gate passas per schedule of credit materials againstcontract agreement). |
| 62 | Material and labour for cutting chasing,pinning ofbrick/ stone/concrete wallat any height wall cutting and chases for concealedwiring for 20/25 mm PVC conduit dia pipe,water tubing,etc and making good to facings where required and pointing in cement motor 1:3 to ends or edges of landigs,wall surfaces etc,cutting not exc 10 cm girth and including making good the disturbed surfaces to match with existing surface and colour shade with proper putty for smooth finishing with existing wall complete all as specified and directed |
| 63 | M&L for point wiring using approved colour coding incl providing circuit wiring with 1.5 sqmm PVC insulated, FRLSH type, ISI marked,conf to IS-694/1990 unsheathed,multistranded,single core, coppercable 1100 volts grade cablesdrawn throughPVCConduit 20/25 mm dia medium grade(MMS) at any height and all accessoriesare concealedinwalls / roofs / floors / ceiling etc. flush mounting modular MS boxmade out of 1.60mm thick suitable for modular top cover and framefor fixing of modular switches,sockets,fan regulators, blank plate etc andincluding 1.5 Sqmm PVC insulated multistranded FRLSH type unsheathed(Green colour),single core cable with coppercable as earth continuity conductor andconnecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour shade with necessary putty for smooth finishing complete all as specified and directedfor One light point controlled by one 10amps switch, one way |
| 64 | All as per item no. 63 but for Onefan point controlled by one switch 10 amps, and oneregulator. |
| 65 | All as per item no. 63 but for Oneexhaust fan point controlled by one switch 10 amps,one way |
| 66 | All as per item no. 63 but forOne 5 pin 6 amps socket point controlled by one 10 amps switch on independent board . |
| 67 | All as per item no. 63 but forOne 5 pin 10 amps socket point controlled by one 10 amps switch on same board . |
| 68 | All as per item no. 63 but for One light point controlled by two 2 way switches. |
| 69 | All as per item no. 63 but for point wiring with 2.5 sqmm and earth conductor of size 2.5 sqmm complete all as specified and directed for One 6 pin 16/20amps socket outlet point controlled by one 16/20 amps switchon independent board. |
| 70 | All as per item no. 69 but for One 6 pin 16/20 amps socket outlet point controlled by one 16/20 amps switch on same board. |
| 71 | All as per item no. 63 but for point wiring with 4.0 sqmm and earth conductor of size 4 sqmm complete all as specified and directed. |
| 72 | Supply & fixing modular type switch 10 Amps, single pole,1way,1 module,240V,AC, withISI Markedcomplete all as specified and directed. |
| 73 | Supply & fixing modular type switch 10 Amps ,2way,single pole,1 module,240V,AC,with ISI Markedcomplete all as specified and directed. |
| 74 | Supply & fixing modular type switch 16/20 Amps, single pole,1way,1 module,240V,withISI Marked complete all as specified and directed. |
| 75 | Supply & fixing modular type socket shuttered type 10 Amps, 2/3 Pin combined 2 module,240V,ACISI Marked complete all as specified and directed. |
| 76 | Supply & fixing modular type socket 16/20 Amps, 6 Pin combined shuttered socket 2 module,240V,ACISI Markedcomplete all as specified and directed |
| 77 | Supply & fixing modular type step fan speed regulator 120W, 2 module,230volts,AC, 360 degree rotation 1 to 8 steps,ISI Markedcomplete all as specified and directed. |
| 78 | Supply & fix angle lamp holder latest model, insulated PVC out side body and brass inside holder with back plate for batten fittings/bulbscomplete all asspecified and directed. |
| 79 | Supply & fix ceiling rose, 3 terminal ,PVC/polycarbonate body ISI marked, complete all as specified and directed |
| 80 | Supply & fixdecorative box type 40 watt light fitting, end caps, pre-wired and including providing single/double sideLED tube light (tube rod) white/warm 40 watt-01 Nomade of aluminium extrusion with high efficientLED driver,IP-20, Tube efficiency of 100lm/w, including PVC/Wooden round/square block -02 Nosand connected with LED fitting to ceiling roseand including removing old unserviceable fitting complete all as specified and directed. |
| 81 | Supply and fixing 20 watts LEDAustra ARK mirror smart light fitting one feet long,contemporary design of mirror light complete decorative LED lighting with extruded polycarbonate, environmentalfriendly, energy efficient, easy to install,PC diffuser, high quality materials,pre-wired including providing PVC round/PVC square blocks-02 Nos and connected with LED fitting to ceiling rose terminal and incl removing old unserviceable fitting complete all as specified and directed. |
| 82 | Supply and fix LED secruity light fitting of capacity 60 Watt LED street light fitting in aluminium PDC housing, toughened glass cover with IP65 protectionwith 4/5 KV inbuilt surge protector and cable connection from ceiling rose/looping box/switch board/DBs to light fitting and testing and including removing of old unserviceable item complete all as specified and directed. |
| 83 | S & F Energy efficient and energy saving new generation 10 watts LED bulk head light fitting IP-65 luminaire with opel diffuser pre-wired ofluminaires including LED light driver and connected with LED fitting to ceiling rose terminaland incl removing old unserviceable fitting complete all as specified and directed. |
| 84 | Supply and fix GI bracket pipe of size 32 mm dia medium grade of 1.2 mtr long bent to shape suitable degree of bending as per site requirementwith hot or coldbending method of process for making the one end of GI pipe bracket suitable for fixing of any type street light fitting and shall be fixedonwall surfaces and including providingsuitable fabricate galvanised flat ironclamps of 30X6 mm thick-02 Nossuitable for fixing at any place/height with hole fastners,nuts,bolts & washers including grouting on wall etc and including removing of old unserviceable item complete all as specified and directed. |
| 85 | Supply & fixingand sheet metal enclosurewith acrylic door type, double door ,415 volts AC,VTPNDB, 4 way,8+12 modules, flush mounting with 200amps copper busbar, 2 neutral/earth bars links and MCCB incomer,and MCB SPN/SP/TPNas outgoing and complete forIP43&54 DBs protection and includingremoving old unserviceable DBs and incl making good the disturbed surfaces to match with existing surface and colour shade complete all as specified and as directed. |
| 86 | Supply & fixing andsheet metal enclosure, with acrylic door type, double door, 240 volts AC,SPN,DB, 8 way, flush mounting with 100amps copper busbar,neutral bar,earth bar links and MCB incomer MCB SPN/DP and MCB SP as outgoingforIP 43& IP54 DBs protection nd includingremoving old unserviceable DBs and making good the disturbed surfaces to match with existing surface and colour shade acomplete all as specified and as directed. |
| 87 | Supply & fix andsheet metal enclosure, with acrylic type double door, 240 volts AC,SPN,DB, 4/6 way, flush mounting with 100amps copper busbar,neutral bar,earth bar and MCB incomer,MCB SPN/DP,and MCB SP as outgoingforIP 43& IP54 DBs protection nd includingremoving old unserviceable DBs making good the disturbed surfaces to match with existing surface and colour shade complete all as specified and as directed. |
| 88 | Supply & fixMCB SP 6 to 32 Amps 10 KA,\"C\" series,AC,240Volts,50Hz , ISI marked and including removing old unsv items complete all as specified and directed. |
| 89 | Supply & fix and MCB SPN 32 to40 Amps 10 KA,\"C\" series,AC,240Volts,50Hz, ISI marked and including removing old unsv items complete all as specified and directed. |
| 90 | Supply & fix and MCB TPN 4063 Amps 10 KA,\"C\" series,AC,415Volts,50Hz, ISI marked and including removing old unsv items complete all as specified and directed as approved by GE |
| 91 | M & L for sub main wiring complete in repairs with 4 run of 10 sqmm single core copper conductor (ISI marked)cable1100 volts grade, ISI marked,FRLSH type (conforming to IS-694/1990 as amended) PVC insulated, unsheathed,flexible,multi strandedcolour coded cables drawn through and including rigid PVC conduit in concealed ISI marked medium grade(MMS) with all connected accessories such asBend,Tee,Elbow,Short peices etc concealed in wall/roofs/floorsand including one run of 10 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, ISI marked,FRLSH type as earth continuity conductor connected to common earth dolly and including removing old unsv submain wiring making good the disturbed surfaces to match with existing surface and colour shade and complete all as specified and directed.Note : - Four run of 10 sqmm single core copper conductor cable and one run of 10 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit. |
| 92 | M & L for sub main wiring complete with 2 run of 6 sqmm single core copper conductor (ISI marked)cable1100 volts grade, ISI marked,FRLSH type (conforming to IS-694/1990 as amended) PVC insulated, unsheathed,flexible,multi strandedcolour coded cables drawn through and including rigid PVC conduit concealed ISI marked medium grade(MMS) with all connected accessories such asBend,Tee,Elbow,Short peices etc concealed in wall/roofs/floorsand including one run of 6 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, ISI marked FRLSH type as earth continuity conductor connected to common earth dolly and including removing old unsv sub main wiring andmaking good the disturbed surfaces to match with existing surface and colour shade and complete all as specified and directed.Note : - Two run of 6 sqmm single core copper conductor cable and one run of 6 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit. |
| 93 | Supply and fixMCCB,125 Amps,4 pole,415 Volts , 16/18KA thermal magnetic type with necessary lugs,thimbles, nuts bolts and washersand including removing old unserviceable itemcomplete all as specified and as directed. |
| 94 | Supply and fixingceiling fans complete with blades, down rods, and connected accessories, 230 V, 1200/1400mm sweep, copper winding,antidust -dustproof painted type,high speed,down rod. Star rated with induction motor complete all as specified and directed. |
| 95 | Taking down old unserviceable exhaust fans of any type/sweep from work site and deposit to MES store yard Supply and fix new exhaust fan, steelbody AC single phase.230Volts of size 300 mm sweep with bladesand including providing insect protection net frame , with louvers and frameincl writing MES No on exhaust fan with synthetic enamel paint complete all as specified and directedcomplete all as specified and directed. |
| 96 | Taking up/down old unsv underground cable from existing locations and supply, laying and testing cable XLPE insulated,screened,PVC bedded,galvanized steel strip or wire armoured,electric power cables 1100 volts grade with stranded aluminium conductor of size 50 sqmm,3.5 core complete all as specified and directed. |
| 97 | Boaring holes horizontally under road without damaging the surface of road (minimum 1.0 Mtr bellow the road surface) with the help of GI tubing of any dia not exc 80mm dia for passing of UG cable all as specified and as directed. |
| 98 | Supply and filling in and speading unwashed river sand for cushioning and covering the under ground cables in trenches and punning to provide required cover complete all as specified in SSR Part-I and as directed. |
| 99 | Excavation in trenches not exceeding 1.5 mtr wide and not exc 1.5 mtr depth for laying of cables, pipe lines, protection pipes and foundations etc and getting out in soft loose soil complete all asspecified and directed. |
| 100 | Returning filling in soil including spreading leveling watering and well rammimg in layer n exc 25 cm complete all as specified and directed |
| 101 | Removing excavated soil not exc50 mtr ant depositing where directed at a level not exc 1.5 mtr above the starting point all as specified and directed |
| 102 | M & L for brick sub class \"B\" 250mm x 115mm x 0.75mm and laid in trenches as in protection of UG cablecomplete all as specified and directed. |
| 103 | Material & labour for GI pipe 50 mm \"light grade\" laid in trenches floors/on , pole/road for cable protection with all fittings complete all as specified and directed. |
| 104 | Material and labour for Earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directely in ground vertically ( earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres belowground level, connected to and including galvanised iron wire 4 mm dia and light grade protection pipeof 15 mm diafrom earth electrode up to test point or up to 7.5mtr whichever is less by means of GIbolts, nuts, check nuts and washersall as per electrical plate No 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade,GI funnel with wire mesh,including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber 1:3:6 type C1, of size 45X 45X 45 CM,RCC/(PVC hevy duty cover) cover 1:2:4 type B1 of size 45X45X6CM, excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required valueincluding removing old item completeall as specified and directed. |
| 105 | Supply and fixing of metal flush box 1/2 module, ISI marked,and suitable for existing type as per site requirement and including removing old unserviceable item from existing loaction complete all as specified and as directed. |
| 106 | Supply and fixing ofmetal/PVC flush box 3 module ,ISI marked, and suitable for existing type as per site requirement and including removing old unserviceable item from existing loaction complete all as specified and as directed. |
| 107 | Supply and fixing of metal/PVC flush box 4/5 module, ISI marked,and suitable for existing type as per site requirement and including removing old unserviceable item from existing loaction complete all as specified and as directed. |
| 108 | Supply and fixing of metal/PVC flush box 6 module,1.60mm thikness ,ISI marked and suitable for existing type as per site requirement and including removing old unserviceable item from existing loaction complete all as specified and as directed. |
| 109 | Supply and fixing of metal/PVC flush box 8 module,1.60mm thikness ,ISI marked and suitable for existing type as per site requirement and including removing old unserviceable item from existing loaction complete all as specified and as directed. |
| 110 | Supply and fixmodular white cover plate with frame 1 modulesuitable for GI flush box,ISI marked and suitable for site requirement for above point wiring and incl screws,washears etc complete all as specified and as directed. |
| 111 | Supply and fixmodular white cover plate with frame 2 modulesuitable for GI flush box,ISI marked and suitable for site requirement for above point wiring and incl screws,washears etc complete all as specified and as directed. |
| 112 | Supply and fixmodular white cover plate with frame 3 modulesuitable for GI flush box,ISI marked and suitable for site requirement for above point wiring and incl screws,washears etc complete all as specified and as directed. |
| 113 | Supply and fixmodular white cover plate with frame 4 modulesuitable for GI flush box,ISI marked and suitable for site requirement for above point wiring and incl screws,washears etc complete all as specified and as directed. |
| 114 | Supply and fixmodular white cover plate with frame 6 modulesuitable for GI flush box,ISI marked and suitable for site requirement for above point wiring and incl screws,washears etc complete all as specified and as directed. |
| 115 | Supply and fixmodular white cover plate with frame 8 modulesuitable for GI flush box,ISI marked and suitable for site requirement for above point wiring and incl screws,washears etc complete all as specified and as directed. |
| 116 | Material and labour for 3-layer PP-RPolypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc.ISI Marked IS-15801 lying in trenches/wallc/ceilings or in floors and necessary clamps, saddles etc complete of size outer dia 32-40 mm complete all as specified and directed. |
| 117 | Supply and fixing PPR gate valve(Brass insert) of dia 40 mm fixing at near to building on wall upto one meter height complete all as spfd and directed. |
| 118 | Making connections of PPR pipes distribution branches with PPR main of following sizes of 50 to75mm by providing and fixing tee including cutting and making fusion joint etc |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail