| 1 | Schedule \"A\" |
| 2 | Supply, installation, testing and commissioning of 6.0 Mtr automatic type Electrohydraulic rising Boom Barrier havingElectrohydraulic Drive Mechanisms with internal locking feature circuit controller for Auto off in fully raised and lowered position with limit switches and manual operation in case of Power failure, with aluminium housing, boom connectors, rectangular boom with red reflecting warning tape and rubber buffer, ergonomically emergency release, sinusoidal movement in both directions, drilling template, completely prewired terminal row, microprocessor logic MO63.2 sockets for loop detectors. maintenance main power outlet, double pole circuit breaker, including necessaryCivil Works as per Manufactures instructions for installing rising Boom Barrier, complete all and as specified and as directed and comprising of following design parameters and specifications:- (i) Application Environment Condition Indoor / Outdoor(ii) Drive Motor: Electro-Mechanical DC Brushless(iii) Protection Degree: IP 65 (IP 67 Operator)(iv) Power Supply: 230V AC(v) Finish: Control unit- Powder coated in a suitable colour - Boom- Powder coated white then applied with bright red colour reflecting tape strips.(vi) Housing Dimension: 355mm x 230mm x 1035mm, Housing Colour: Red |
| 3 | (vii) Boom Arm Material: Octagonal aluminium with rubber protection(viii) Opening and closing time: 1.8 to 6 second(viii) Duty cycle: 100% (ix) MCBF (Mean Cycle Between Failure): 12 Millions(x) No. of Digital Inputs: 8 No. of Relays/Digital Outputs: 6/4(xi) Integration: With Long Range RFID Access Control System where applicable, and manual weather proofed over-ride open and close switch(xii) Control Operation: Outdoor manual over-rise and wireless remote switch CE Certified 6 Mtr Boom Barrier have:-a) Supply of Push Buttonb) Supply of Fix Boom Rest Standc) Supply of Flash LED Light on Boom Barrierd) Supply of Loop Detectore) Supply of Remote Controlf) Supply of Photocell Safety SensorMake:Godrej & Boyce Mfg Co. Ltd Type ES-50 or equivalent Make and model of NEPTUNE, GUNNEBO, AUTOMATIC CONTROL |
| 4 | Supply, installation, testing and commissioning of 6.0 Mtr Hydraulic Tyre killer Flat top surface types with electro-Hydraulic drive in separate drive. Emergency operation through hand pump, having steel profile construction to absorb a static load and the wall thickness of the structural components 8 to 10mm, electrical PLC control installed separately in a weather proof lockable steel casing for outdoor installation on a concrete base having maximum 20 Metre distance from the road block, including necessary Civil Work as per Manufactures instructions for installing Road Blocker, complete alland as specified and as directed and comprising of following design parameters and specifications:-(i) System Type Automatic Hydraulic tyre killer active 1-way. (ii) Construction Galvanized steel(iii) Height 150mm (iv) Width 500mm (v) Length 2 mtr to 6 mtr in 500mm Increments (vi) spikes Distance between spikes 100mm. (vii) Opening Closing Time 1-3 sec. (viii) Dia of spikes 25mm(ix) Spike material AISI 304 |
| 5 | (x) Blocking Height 60 Degree, 120mm minimum (Customizable)(xi) Power supply voltage 230V~ - 50Hz (xii) Absorbed power 220 W (xiii) Current consumption 1 Amp(xiv) Accessories max. Current 500mA (xv) Environment Temperature (-) 20°C to (+)70°C(xvi) Ingress Protection IP56 for control unit (xvii) Humidity 10% to 95%RH (xviii) Duty cycle 100 % (xix) Load bearing Capacity 100 Ton.6 mtr Tyre Killer have:-(a) Supply of Push Button(b) Supply of Two CHANNEL LOOP DETECTOR(c) Supply of Photocell Safety Sensor(d) Supply of Wireless RemoteMake: Godrej & Boyce Mfg Co. Ltd Type TC- RBS 675 Basic type or equivalent Make of NEPTUNE, GUNNEBO, AUTOMATIC CONTROL |
| 6 | Supply, laying underground in trenches, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100V grade, cross sectional area 4 core 16 sqmm, complete all as specified and directed by Engineer-in-Charge. |
| 7 | Supply & Fixing factory made sheet metal enclosure MCB Distribution board Double door IP 43 protection class TPN 4 way 415 volts complete with 200 Amps rated bus bar and neutral link, complete all as specified and directed by Engineer-in-Charge. |
| 8 | Supply and fixing MCB TPN 63A 10 KA, class \"C\", complete all as specified and directed by Engineer-in-Charge. |
| 9 | Supply and fixing MCB SP 5-30 A 10 KA, class \"B\", complete all as specified and directed by Engineer-in-Charge. |
| 10 | Excavation in trenches not exceeding 1.5 Metre wide and not exceeding 1.5 Metre in depth and getting out Soft/ Loose soil, complete all as specified and directed by Engineer-in-Charge. |
| 11 | Returning filling in including spreading levelling watering and well Ramming in layers not exc 25 cm thick, complete all as specified and directed by Engineer-in-Charge. |
| 12 | Removing excavated material not exc 50 Metre and depositing where directed at a level not exceeding 1.5 Metre above the starting point, complete all as specified and directed by Engineer-in-Charge. |
| 13 | Supply and laying 50 /38mm Double Walled Corrugated (DWC) Pipes having corrugation on the outer wall and plain surface on the inner wall confirming to IS14930 (Part-II) for protection of UG cables, laid in trenches/ road/ drain or fixed along wall, poles or laid under floor, complete all as specified and directed by Engineer-in-Charge.Make : Rex / Poly/ Gemini |
| 14 | Material & Labour for cutting existing road/hard standing not exc 45 x 45 cm in wide & depth getting out excavated material for laying cable/GI tube, returning filling & well ramming watering finish surface 10 cm from top using PCC 1:3:6; including removal of surpluses soil, complete all as specified and directed by Engineer-in-Charge. |
| 15 | Material & Labour for bore Earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 2.5 metres length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with Earthing lead of 4mm dia galvanised iron or steel wire all as shown in Plate No. 2 to the Earthing test point all as specified and indicated including testing on completion, complete all as specified and directed by Engineer-in-Charge. |