| 1 | SCH \"A\" PART-I (B/R WORK)Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as per specified and as directed by Engineer-in-charge. |
| 2 | Demolition of unreinforced cement concrete in ground floors and pavings nexc 15 cm thickness (below or above ground level) complete all as specified and as directed by Engineer-in-charge. |
| 3 | Demolition of unreinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed by Engineer-in-charge. |
| 4 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as per specified and as directed by Engineer-in-charge. |
| 5 | Dismantling wrought iron or mild steel work of any description not otherwise providedcomplete all as specified and as directed by Engineer-in-charge. |
| 6 | Dismantling framed trusses span n exc 10 mtr, complete all as per specified and as directed by Engineer-in-charge. |
| 7 | M&L for PCC 1:3:6 Type C2 (using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete complete all as specified and as directed by Engineer-in-charge. |
| 8 | M&L for plain cement concrete type C-2, 1:3:6 (using 40 mm gradedstone aggregate) as in surface channels and drains, complete all as per specified and as directed by Engineer-in-charge. |
| 9 | M&L for providing plain cementconcrete type C-1, 1:3:6, (using 20 mm graded stone aggregate), as in copings, bed block for filing hollow space of steel chowkhats, fixing of hold fast, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work, complete all as per specified and as directed by Engineer-in-charge. |
| 10 | M&L for fly ash brick work, straight or curved on plan exc. 6m mean radius in cement mortar 1:6, complete all as per specified and as directed by Engineer-in-charge. |
| 11 | S&F of screw bolts (machine made) (diameter of neck 16 to 20 mm) with hexagonal or square head at one end and screwed the other or screwed both ends to be fitted with washers and one hexagonal or square nut exc. 22.5 cm but n.exc. 30 cm long MS Work as in bands , straps, supports or stays incl bolts, if reqd. , hold fasts, wall ties and similar small articlesconforming to Fe-290 Gde E-165 complete all as specified and as directed by Engineer-in-charge. |
| 12 | S&F of roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. Confirming to Fe 410-W (Gde E- 250) quality-A, includingsteel is painted one shop coat of zinc chromate primer paint (including preparation of surface) at Contractor’s workshop before fabrication, complete all as per specified and as directed by Engineer-in-charge. |
| 13 | Erection and fixing only structural steek work Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracketframing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. Confirming to Fe 410-W (Gde E- 250) quality-A, includingsteel is painted one shop coat of zinc chromate primer paint (including preparation of surface) at Contractor’s workshop before fabrication, complete all as per specified and as directed by Engineer-in-charge. |
| 14 | M& L for MS Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment confirming to Fe 410-W (Gde E- 250) quality-A , complete all as per specified and as directed by Engineer-in-charge. |
| 15 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated or semi-corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa as in roof covering/cladding to wall, fixed with self tapping screws or J hooks, complete all as per specified and as directed by Engineer-in-charge. |
| 16 | S&F of Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa as in roof covering/cladding to wall, fixed with self tapping screws or J hooks, complete all as specified and as directed by Engineer-in-charge. |
| 17 | M&L for 150 mm thick PCC (1:3:6) type C-2 (using 40 mm graded crushed stone aggregate) as in sub-base of floor over cement concrete surface even & fair etc including necessary form work complete all as specified and as directed by Engineer-in-charge. |
| 18 | Providing and laying of 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand, complete all as per specified and as directed by Engineer-in-charge. |
| 19 | M&L for 15 mm thick rendering on fair faces of brick work or concrete surface in cement mortar 1:6, and surface finished even and smooth (without using extra cement),complete all as specified and as directed by Engineer-in-charge. |
| 20 | M&L for applying two coats of oil emulsion distemper over a coat of alkali resistant primer over and including applying 1mm thick wall care putty two coats on newly plastered surfaces of wall after and including preparation of surfaces complete all as specified and directed. |
| 21 | M&L for preparation of new or previously untreated steel or iron surface of any description and applying two coats of synthetic enamel paint, primer over 10cm width or girth complete all as specified and as directed by Engineer-in-charge. |
| 22 | M&L for preparation of old painted surfaces of steel surfaceof any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint, complete all as specified and as directed by Engineer-in-charge. |
| 23 | SCH \"A\" PART-II (E/M WORK)Taking down carefully old unserviceable copper/ aluminium point wiring (light, exhaust fan, socket or power) complete incl fittings such as switches, ceiling roses, pendants, regulators, bells, sockets, tube light fittings etc., and making good disturbed surface of walls & floors etc., complete all as per specified and as directed by Engineer-in-charge. |
| 24 | M&Lfor point wiringcomplete with 1.5 sqmm PVC insulated, FRLS type, ISI marked, conforming to IS-694/1990 unsheathed,multistranded,single core, copperconductor cable 1100 volts grade colour code cablesdrawn through and including PVC casing capping sleeves and caps of adequate width and length, including cutting, chasing work at any height and all accessoriesconcealedinwalls / roofs / floors / ceiling etc. flush mountingMS box with top, bottom, side/back wall knockout for conduitentry from any direction made out of 1.60mm thick and 50mm depth suitable for fixing ofmodular top cover , blankingplate as per numbers of switch modules, modular switches, sockets, fan regulators, red colour indicator, blank plates etc as approved colouresmodular accessories of suitable modules andincluding 1.5 Sqmm PVC insulated multistranded FRLS type unsheathedsingle core cable with copper conductor cable as earth continuity conductor andconnecting to common earth dolly and including making good the disturbed surfaces to match with existing surfaces by applying white/colour wash/distemper as applicable after applying of putty for smooth finish surfacecomplete all as specified and directedfor one light point controlled by one way switch, complete all as per specified and as directed by Engineer-in-charge.(Note:- (i) Allnecessary accessories such as, blank plate, MS box, screws, washers etcare to be used of same make/brand onlyin relevant items.(ii) Cutting & chasingof wall for point wiring at any height shall be done and cost of the same deemed to be including with quoted rate.) |
| 25 | All as per serial item No. 24 above but for one ceiling/exhaust fan point controlled by one switch. |
| 26 | All as per serial item No. 24 above but for one socket outlet 5/6 AMPs on independent board. |
| 27 | All as per serial item No. 24 abovebut with 2.5 sqmm single core copper conductor for one socket out let 15/16 AMPs point on the independent board, complete all as per specified and as directed by Engineer-in-charge. |
| 28 | Supply and fix switch piano flush type, 6/5 Amps 240 volts single pole one way, complete all as specified and as directed by Engineer-in-charge. |
| 29 | M & L for Socket outlet 2 in 1, 3 pin, 6 and 16 amp flush type universal, 240 volts, complete all as specified and as directed by Engineer-in-charge. |
| 30 | S&F ofSocket outlet 2 in 1, 3 pin, 5/6 Amp, white ivory finish flash type, complete all as specified and as directed by Engineer-in-charge. |
| 31 | Supply and of fix ceiling rose surface PVC three terminals, PVC/ polycarbonate, insulated body, complete all as per specified and as directed by Engineer-in-charge. |
| 32 | S&F of Switch piano, flush type single pole, one way 16 Amp, complete all as specified and as directed by Engineer-in-charge. |
| 33 | Supply and fix LED tube light fittings1 x 20 Watt, 4 feet long, 220 V, AC decorative box type with driver holder including LED tube rodconnecting up with three core flexible copper conductor cable from ceiling rose to tube light fitting complete all as specified and as directed by Engineer-in-charge. |
| 34 | Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including taking down old unserviceable street light, complete all as specified and as directed by Engineer-in-charge. |
| 35 | Supply and fixing of ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC), complete all as per specified and as directed by Engineer-in-charge. |
| 36 | Supply and fixing of fan regulator electronic type, rotary step(speed regulation in 5 steps), SP 240 Volt, suitable for ceiling fans complete all as specified and as directed by Engineer-in-charge. |
| 37 | Supply and fix sheet metal enclosure powder painted for MCB SPN 12 way double door DB with din rail and suitable bus bar including cutting chases for DB of reqd size and making good disturbed surface area and putting blanking plate, including taking down old unserviceable DB, complete all as specified and as directed by Engineer-in-charge. |
| 38 | Supply and fixing of amp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of SPN 40 to 63 AMP and current carrying capacity in the MCB DB complete with connection testing complete all as specified and as directed by Engineer-in-charge. |
| 39 | Supply and fixing of amp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of SP 6 To 32 AMP current carrying capacity in the MCB DB complete with connection testing and commissioning, complete all as specified and as directed by Engineer-in-charge. |
| 40 | M&L for earthing with glavanised steel earth plate electrode of size 600mmX600mmX6mm thick buried directly in ground (earth pit not less than 2.25 m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts, check nutsand washers of galvanisediron or steel using GI or steel wire 4mm dia as earthing lead as shown in electrical plate No.3 of SSR Part-I connected to earthing test point all specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposalof surplus soil, earth pit in PCC (1:3:6) type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe , 15mm dia GI medium grade earth lead protection pipe and pre-cast earth pit cover 50mm thick made of RCC (1:1.5:3) type A-1 duly reinforced with 8mm dia TMT bar @150c/c both ways, one lifting handle made out of 10mm dia TMT bar 250 mm long embedded in cover slab and cover, wire, copper lugs etc mesh, charcoal and common salt in alternate layer of 15 cm thick including taking down old earthing completeall as specified and directed.(Notre: Galvanised iron wire of 4mm dia upto 7.5m long including testingis deemed to be included with quoted rate). |
| 41 | S&F of street light bracket made out of GI tubing 25 mm bore medium grade 1.20 Mtr long bend to required shape as in bracket for street light fittings fixed with two No of MS flat iron 25mm x 5mm size and 30cm long clamp of required shape with bolts nuts and washers suitable for building security light including painting of mild steel flat iron surfaces with two coats of aluminium paint over a coat of red oxide primer, including taking down old unserviceable GI bracket, complete all as specified and as directed by Engineer-in-charge. |
| 42 | S&F XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 1100Volt grade on walls with fixing acessories of size 16 Sqmm4 Core cable including taking down old cable, complete all as per specified and as directed by Engineer-in-charge.(NOTE: Excavation/earth work, sand cushioning, cable cover/brick shall be measured and paid separately if required) |
| 43 | Supply & Laying of Sub-Class B Bricks, well burnt, laid breadth wise along the length of cable laid in trenches over sand cushion laid for UG cable protection, complete all as per specified and as directed by Engineer-in-charge. |
| 44 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-charge. |
| 45 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm in hard/dense soil, complete all as per specified and as directed by Engineer-in-charge. |
| 46 | Removing excavated soil material not exc. 50 m & depositing where directed at a level not exc. 1.5 m above starting point complete all as specified and as directed by Engineer-in-charge. |
| 47 | M&L for sand cushioning to under ground cable in trenches/existing cable trenches/ductsin layers of 8 cm deep before laying the cable and 15 cm deep including required watering and consolidation after laying and stretching the cable complete all as specified and directed. (Note: Only punned down volume of sand to be measured)NOTE:-The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule \"A\"/BOQ. |