| 1 | Dismantling of asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed. |
| 2 | Dismantling of timber scantling 40 sqcm and over in section, in any position as in framed work complete all as specified and as directed. |
| 3 | S&F Pre-painted galvalume aluminum zinc coated GI based corrugated steel sheet 0.50 mm thick ofcolour,as approved having tensile strength of 550 Mpa, AZ-150 as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 4 | S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick ofcolour as approved having tensile strength of 550 Mpa, AZ-150 as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 5 | Dismantling of boarding of any deescription and fixed in any position with nails complete all as specified and directed. |
| 6 | S&F in repairs E-boards, ceiling, 4 mm thick with J framed work with mainTee of size 24 x 28.5 mm made out of PGI sheet .3 mm thick double at web and single at flange, flange coverd with powder coated sheet 0.25 mm thick and wall angle 24 x 24 x .45 mm powder coated for ceiling , ceiling boards 60cm x 60cmx 4mmthick , suspended with GI wire 2mm dia and 2m average length with adjustable hanging device complete including plugging in brick/stone walls with steel rawl plug @ 600 mm C/C Ceiling board shall be pressed to the ceiling tee with staple clips at all four sides and painted with two coats of oil bound distemper incl making good all the disturbed portion complete all as spd & directed. |
| 7 | S&F rolled mild steel section for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., conforming to Fe-410-W(Gde-E-250) quality-Acomplete all as specified and as directed.Note : The rates quoted allow for cutting to dead length where required, notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting angle cleats, fish plates, gusset plates etc., also for wedging, plumbing, truing up and fixing complete. |
| 8 | S&F mild steelPlates (plain or chequered) channels,squarecutor notched (ordinaryand countersunk) forming holes, without any attachment confirming to Fe 410-W (Gde E- 250) quality A complete all as specified and as directed. |
| 9 | S & F mild steel screwbolts 05 to 10 mm dia ( Machine made) with hexagonal or square heads at one end and screwed the other, each screwed end to be fitted with washers and one hexagonal or square nuts exc 5 cm and n exc 10 cm long, complete all as specified and directed. |
| 10 | S&F mild steel work as in hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc and similar work conforming to Fe-290 Gde E-165 steel with and including necessary drilling holes etc complete all as specified and directed.Note: The unit rate quoted by contractor is deemed to be inclusive of cutting to dead lenth where required, notching, drilling, fitting, rivetting and/or welding or connecting with bolts and nuts (including rivets or bolt and nuts), providing and fiitings angle cleats, fish plates, gusset plate etc., also for welding plumbing, truing up and fixing complete. No claim whatso ever shall be entertained by Govt on this account. |
| 11 | Taking down chowkhats or frames of any description with shutters (without taking off shutter from the frames) not exceeding 1.5 Sq.m each complete all as specified and directed. |
| 12 | Taking down chowkhats or frames of any description with shutters (without taking off shutter from the frames)exceeding 1.5 Sq.m each but n exceeding 4.0 sqm each complete all as specified and directed. |
| 13 | Providing and fixing windows & ventilators fabricated from Rolled Formed GI Section made of Galvanised steel colour coated(PPGI Sheets) (Base steel as per IS 513 ‘’D’’ quality. Galvanised as per IS 277 with Zinc of 90 Gsm/SqMt w. PAINT: Pre-Painted sections should be with primer coat of epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with alkyd backer of 5-7 microns or powder coated with pure polyester powder upto 50-60 microns thick.GI Section of 0.58mm thick inDouble rebate windows in which both glazed shutter andflymesh shutter, 74 X 60mm outer frame , Mullion 72 x 49mm, Glazed shutter 48 x 22mm, Flymesh 41 x 22mm, Beading with round ends for Glass Fixing 12 x 12mm in fixed portion and the outer frame and mullions to have rebate for glazed/gauzed shutters the sections cut to length metre joined with corner PolyVinylChloride brackets centre mullion fixed with PolyVinylChloride Mullion caps . Glass of 4mm thick plain float glass fitted with Ethylene Propylene Diamine Monomer in glazed shutterand wiremesh of Stainless steel of 36 guage to fix mesh in mesh shutter using VC Black Gypsum Drywall screws and Spoon profile of 0.58mm GI Sheet. Corners of the windows should be joined with corner brackets made of polyvinylchloride with crca of zinc phosphate coat.Each glazed shutter and fly mesh shutter shall be provided with SS Pivot Hinges 2 in each,PolyVinylChloride handle 1 in each and Powder coated Peg stay in Glass shutter.Window shall be provided with Powder coated MS Grill/Guard Bars made of 10mm MS Sq Bar welded to 6 x 12mm MS Flat with countersunk holes at both vertical ends . Gap between the bars should not be more than 150mm .Window frames shall be fixed to brick / concrete masonry by using nylon self expension caps & 75/100 mm MS screwsafter drilling in walls. VC Black Gypsum Drywall screws should be used while fixng corner brackets,stay,hinges,mullion caps of windows. complete all as specified. |
| 14 | S&F Factory made double rebate WPC (wood polymer composite) solid door frames/chowkat of size 65x125 mm of virgin PVC Polymer of K value 58-60(Suspension Grade) calcium carbonate and natural fibres (wood powder/rice husk/wheat husk ) and non toxicadditives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threated star heads SS screw having minimum frame density of 750 kg/cum screw withdrawal strenght of 2200 N (face) and 1100 N (Edge)proof,minimum compressive strenght of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water / moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete all as specified and directed. |
| 15 | S & F 30mm thick factory made modularsingle extruded WPC (Wood Polymer Composite) solid decorative type flush door shuttercomprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws,complete all as specified and directed.(Note: butt hinges and necessary S.S screws shall be paid separately) |
| 16 | S & F 35 mm thick factory made modularsingle extruded WPC (Wood Polymer Composite) Wire mesh / glazed solid decorative type flush door shuttercomprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and directed.(Note: butt hinges and necessary S.S screws shall be paid separately) |
| 17 | M&L for Prelam Solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supplying & fixing in opening as per specification and drawing complete all as specified and directed. |
| 18 | S&F Factory made solid panel PVC door shutter 30mm thick prelam(style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the MS frame welded/ sealed to the stiles & rails with suitable PVC sheet beading, and jointed together with solvent cement, supplying & fixing in the frame at site as per manufacturer’s instructions complete all as specified and directed. |
| 19 | S & F Butt hinges, 100 mm long extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21 ISI marked complete all as specifiedand directed. |
| 20 | S & F Aluminium handles cast type anodised of size 150mmISI marked complete all as specified and directed. |
| 21 | S & F 250mm long aluminium alloy anodised sliding door bolt with hasp staple, bolt type, and fixing clips of sheet, cast or extruded sections & fixing bolts and sliding bolts of extruded section or cast aluminium alloy, ISI marked complete all as specified and directed. |
| 22 | S & F 100 mm long, aluminium anodised, barrel tower bolts, of extruded section ISI marked complete all as specified and directed. |
| 23 | M&L for twocoats of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surface over 10cm width or grith complete all as specified and directed. |
| 24 | M&L for twocoats of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surface n exc 10cm width or grith complete all as specified and directed. |
| 25 | Demolition of brick work or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins,arches, pillars,etc. but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. |
| 26 | M&L for brick work with old size full bricksubclass ‘B’ burnt clay bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified and directed. |
| 27 | Taking down cement plaster on brick or stone wall surfaces including glazed tiles wherever exists including raking out joints, hacking for key and scrubbing down with water and removing unseviceable materials out side MoD land complete all as specified and as directed. |
| 28 | M&L for 15mm thick plastering on fair faces of brick wall in two layers, Ist layer 10mm thick CM (1:6), and IInd layer 5mm thick CM (1:4), surface finished even and fair(without using nextra cement) mixed with @ 200ml per bag WPC (liquid type) complete all as specified and directed.Note :- WPC (Liquid type) shall be measured and paid separately as supply only. |
| 29 | M&L for 10 mm thick plastering onbrick or contretesurfaces, in CM (1:6), surface finished even and smooth without using extra cement complete all as specified and directed. |
| 30 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. Note:-1. The newly plastered surface must be prepared in a manner so that there should not be any impression of dent and it should be made even all as per manufacture instruction before application of emulsion paint. The cost of all materials, T&P and labour required for preparation of surface are deemed to be included in the rates quoted. (ii). The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor.The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work. (iii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by department for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture.(iv). after carrying out preparation of surface the same shall be got approved from GE /AGE (I) before application of distemper for each building.(v).The colour / shade will be all as approved by GE / AGE (I)(vi) The cost of Scaffolding wherever required are deemed to be included in the rates quoted by the contractor |
| 31 | M&L preparing newly plastered surfaces ,and applying 2 coats of Oil Bound Distemper over a coat of alkali resistent primer over 1mm thick wall putty on walls complete all as specified and directed |
| 32 | M&L preparationof old distempered surface of wall, pillasters cornices etc by washing rubbing down & stopping etc and applying one coat of oil emulsion distemper complete all as specified and as directed |
| 33 | Material & Labour for Preparation of old decorated plastered or un plastered surfaces of walls including brooming downor steel wire brushing, scrappingdown smoke soot, moulds, moss and efflorescentsalts and trading oil and greasy spots and including filling the nail holes and small patches of peeled off plaster of size not exc 0.01 Sqm by using filling compound of Altek/Birlawhite putty to obtain even & smooth finish by using sand paper preparation and applyingtwo coats of exterior anti fungal acrylic emulsion paint having three years of performance warranty) over a coat of exterior water based primer of same make all as specified and prescribed by manufacture of paint and as directed at site by Engineer-in-Charge.Note: (i) The old surface must be prepared in a manner so that there should not be any impression of dent and it should be made even all as per manufacture instruction before application of distemper.The cost of materials, labour & T&P required for preparation of surface are demand to be included in the rates quoted.(ii). The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor.The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work. (iii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by deportment for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture.(iv). after carrying out preparation of surface the same shall be got approved from GE /AGE (I) before application of distemper for each building.(v).The colour / shade will be all as approved by GE / AGE (I)(vi) The cost of Scaffolding wherever required are deemed to be included in the rates quoted by the contractor |
| 34 | M&L for preparation of old painted surface of wood and wooden based material of any description over 10 cm width or girth and applying one coat of synthetic enamel paintcomplete all as specified and as directed. |
| 35 | Supply only WPC integral water proofing compound (Liquid type) complete all as specified and directed. |
| 36 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to storeand rubbish off the premises from MoD land complete all as specified and as directed. |
| 37 | M&L for non skid ceramic coloured tiles 7mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floorsover 15 mm thick screed bed or bedding layer in CM 1:6 finished fair and even for laying floor finishes/tiles etc complete all as specified and directed . |
| 38 | S & F glazed ceramic coloured tiles of size 450mmx350mmx 7 mm thick on vertical surface such as skirting, dados, risers to steps etc set &jointed in neat cementslurry and pointed inwhite or coloured cementto match the colour oftiles over and including 10mm thick cement plaster in CM (1:4) complete all as specified and directed. |
| 39 | Demolition of cement concrete in ground floorand pavings not exc 15 cm thickness below or above ground levelincluding removal of rubbish out side of MOD land complete all as specified and directed. |
| 40 | M&L for 75mm thick PCC (1:3:6), type C-2 using 40mm graded stone aggregate as in plinth protection, surface finished even & faircomplete all as specified and directed. |
| 41 | S & F in repair vitreous china squatting pan \"Orissa pattern\" size 580X 440 mm white with integral foot rest (excluding flushing cistern and flush pipe) including provision of lime concrete bedding etc complete all as specified and directed. |
| 42 | Taking up or down steel tubing and connections,15 mm bore including cleaning for refixing or removal to store complete all as specified and directed. |
| 43 | S&F 15mm dia medium grade GI tubing with all fittings and fixtures complete fixed to walls, ceilings etc all as specified and as directed. |
| 44 | S & F in repairbib tap 15 mm dia cast copper alloy CP with crutch or butter fly handle screwd for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 45 | S&F in repair PVC valve less syphonic action type flushing cistern 10ltr capacity low level, white/coloured with inlet ball valve flaot and handle including bracket and fixing of PVC flush pipe 32 mm dia and PVC connection pipes complete all as specified and directed. |
| 46 | S & F in repair15 mm bore CPstop valve , cast copper alloy, screweddown, highpressure, withcrutch or butterfly handle, screwed both ends foriron pipe orfor unions and fixed, complete all as specified and directed. |
| 47 | S&F in repair PVC connection15mm dia, 450mm long with PTMT check nuts and washer on both ends complete all as specified and directed. |
| 48 | S & F in repair Curtain rods 20mm dia, mild steel, chromium plated with fixing brackets, stops, rollers etc complete all as specified and directed. |
| 49 | S & F in repair Soap dish, Mild steel Chromium plated, fixed to plugs with chromium plated brass screws complete all as specified anddirected |
| 50 | Taking down carefully copper/aluminum point wiring (light/fan/socket power) complete , including fixture and fitting such as switches, ceilling roses, pendants, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition seperately) and making good disturbed surfases of walls, floors, etc. all as specified and directed. |
| 51 | Material & Labour for Point Wiring for one light Point/one fan point/ one call bell point, controlled by one switch with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 sqmm multi stranded copper conductor cable (FRLSH) with continuous earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed , drawn in and including concealed rigid PVC conduit(ISI marked) ,duly cutting chases & concealed to wall/floor or above false ceiling with fittings(ISI marked) not less than 20 mm dia(Color coding of wires shall be Phase, neutral and earth wire all as specified ) including metal flush box made of GI sheet and white cover with making good the disturbs surfaces of wall/floor/ceiling complete all as specified and directed for the following.Note: Flush box and cover plate should be of same make all as approved for switches/sockets. |
| 52 | One light/fan/bell point controlled by one No modular type switch 6 Amps single pole one way complete all as specified & directed. |
| 53 | One 3 pin 6 Amps socket outlet on same board controlled by one, one way 6 Amps modular switch complete all as specified & directed. |
| 54 | One socket outlet 5/3 pin 6 Amps controlled by one modular switch on independent board. omplete all as specified & directed. |
| 55 | All as per item No 51 here-in-before but wiring with 2.5 sqmm single core multi stranded copper condcutor1100 V grade PVC insulated FRLSH but unsheathed single core for16 Amps power point on independent board and 2.5 sqmm FRLSH cable as earthwire complete all as specified & directed. |
| 56 | S & F switch Modular single pole,one way 6 Amps , 1 module,230 volts, 50 hzcomplete all as specified and directed. |
| 57 | Supply and fix Modular switch 1 way 16 Amps, 1 module, 230 volts, 50 Hz complete all as specified and directed. |
| 58 | Supply and fixModular Socket outlet, 6A - 2/3 pin combined, 2 module ISI marked, 230 volts, 50 hz complete all as specified and directed. |
| 59 | Supply and fixModular Socket outlet, 16A - 2/3 pin combined, 2 module ISI marked, 230 volts, 50 hz complete all as specified and directed. |
| 60 | S&F ceiling rose 3 terminal / PVC/ polycarbonate, isolated body complete all as speccified and directed |
| 61 | S&F MCB DB SPN 8 way, 240 volts in sheet steel enclosure.double door type including taking down old DB complete all as specified and directed. |
| 62 | S&F MCB DB TPN 4 way with suitable rating, 415 volts rated aluminium busbarin sheet steel enclosure.double door type including taking down old DB complete all as specified and directed. |
| 63 | S&F MCB , SP, AC, 240 volts of 06 to 32Amps capacity 10KA, \"C\" series and making connections with suitable size of copper lugs complete all as specified & directed. |
| 64 | S&F MCB, SPN, AC, 240 volts of 40 Amps capacity 10KA, \"C\" series and making connections with suitable size of copper lugs complete all as specified & directed. |
| 65 | S&F MCB, TPN, AC, 415 volts of 63 Amps capacity 10KA, \"C\" series and making connections with suitable size of copper lugs complete all as specified & directed. |
| 66 | S& F surface mounted LED luminiare, 10 watt, 2 Feet with all accessories having aluminumextruded channel with diffuser for glare free light, high lumen output, driver PF >0.90 having over voltage protection upto 400 voltsand lumen efficiency >120 lumen per watt, internally pre-wired through flexible wire connecting with ceiling rose complete all as specified & directed. |
| 67 | S& F surface mounted LED luminiare, 20 watt, 4 Feet with all accessories having aluminumextruded channel with diffuser for glare free light, high lumen output, driver PF >0.90 having over voltage protection upto 400 voltsand lumen efficiency >120 lumen per watt, internally pre-wired through flexible wire connecting with ceiling rose complete all as specified & directed. |
| 68 | Supply and fixLED building security light 1 x 20 W housing made out of pressure die-cast aluminium alloy with toughned glass, IP 65 protection working on 240 volts, 50 Hz, consisting of reflecting lamps wired with appropriate driver PF> 0.90 having over voltage protection upto 440 volt,including fixed on wall with 1.2 mtr 32 mm GI pipe bracket & 02 Nos MS clamp made out of F1 40 x 6 mm or as directed including connecting with 1.5 sqmm , 3 core, PVC insulated copperconductor cable 1100 Volt grade from ceiling box to light complete all as specified and as directed. |
| 69 | S&F sub main wiringtwo single core6 Sqmm PVC insulated, unsheathed, stranded copper conductor cable(FRLSH) 1100Volts grade drawn in & including rigid PVC Conduit 20mm dia or more medium grade concealed in wall along with 6.00 Sqmm PVC insualted unsheathed copper conductor cable (FRLSH) as earth wire andwire connected with main earth dolly including cutting chases and making good disturbed portion complete all as specified and directed. Note : Two runs of phase, neutral wire and one run of earth wire and PVC conduit will be measured as one RM or one length. |
| 70 | Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. ( earth pit not less than 2.25 mtr depth below ground levelat any type of strata ) with top edge of the earth plate not less than 1.5mtr below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all around the plate. connected by 4mm GI Wirecheck nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320x320x80mm size (1:2:4) Type B1 using 20mm graded stone aggregate rainforced with XPM all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI strip upto 7.5 mtrs long with 15 mm dia light grade GI pipe protection and watering pipe of GI 40 mm bore, medium grade, including all exavation and earth work and connecting the earthing strip to panel, including testing on completion complete all as specified and directed . Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick rainforced with XPM weighing not less than 4kg/sqm in lieu of CI cover.(ii) Cost of additional GI strip more than 7.5 mtrs will be measured and paid seperately under relevant items. |
| 71 | S&F 36 Watt,LED Panel 2X2 Feet environmentalfriendly, fully diffused, using engineering grade aluminum diffuser, new generation, aesthetically designed, CRCAhousing, ultramodern recess mounting luminaire with high brightness SMD LEDsas light source, suitablefor Armstrong/ Grid Ceiling, Voltage range – 120v- 280V AC, System efficacy – 110 Lumen / Watt, power factor >0.90, thd<15%, CCT 6500K,with separate electronic driver ceiling light 36W including connectingup with twin core twisted flexible copperconductorcable with suitable size of 230V, 50HZ allas specified & directed. |