| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 Sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil. ((DSR -2.8.1)) |
| 2 | Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil1.5M - 3.0M ((DSR -2.26)) |
| 3 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. ((DSR -2.25)) |
| 4 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. ((DSR -2.27)) |
| 5 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration ((DSR -2.35.3.1)) |
| 6 | Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.:With Chlorpyriphos/ Lindane E.C. 20% with 1%concentration ((DSR -2.35.2.1)) |
| 7 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) ((DSR -4.1.8)) |
| 8 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size) ((DSR -4.1)) |
| 9 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7Kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. ((DSR -4.13)) |
| 10 | \"Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, PortlandPozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.:Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content indesign mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear thecost of extra cement.\" All works upto plinth levelConcrete of M25 grade with minimum cement content of 330 kg /cum ((DSR -5.33.1.1)) |
| 11 | All works above plinth level upto floor V levelConcrete of M25 grade with minimum cement content of 330 kg /cum ((DSR -5.33.2.1)) |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form forFoundations, footings, bases of columns, etc. for mass concrete ((DSR -5.9.1)) |
| 13 | Suspended floors, roofs, landings, balconies and access platform ((DSR -5.9.3)) |
| 14 | Lintels, beams, plinth beams, girders, bressumers and cantilevers ((DSR -5.9.5)) |
| 15 | Columns, Pillars, Piers, Abutments, Posts and Struts ((DSR -5.9.6)) |
| 16 | Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. ((DSR -5.9.2)) |
| 17 | Stairs, (excluding landings) except spiral-staircases ((DSR -5.9.7)) |
| 18 | Arches, domes, vaults up to 6 m span ((DSR -5.9.9)) |
| 19 | Edges of slabs and breaks in floors and wallsUnder 20 cm wide (NSR) |
| 20 | Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured).Suspended floors, roofs, landings, beams and balconies (Plan area to be measured)UPTO -4.5 M (NSR) |
| 21 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. ((DSR -5.22.6)) |
| 22 | Providing and fixing in position Stainless steel Grade 304 plate-1.0 mm thick as per design for expansion joints.200 mm wide. ((DSR -5.43.1)) |
| 23 | Brick Work with common burnt clay ( non modular) bricks of class - 150 in foundation and plinth in: Cement mortar 1:6 ( 1 cement : 6 coarse sand) ((DSR -6.1.2)) |
| 24 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in: Cement mortar 1:6 (1 cement : 6 coarse sand) ((DSR -6.4.2)) |
| 25 | Extra for forming cavity 5 cm to 11.5 cm wide in cavity walls with necessary weep and vent holes including use of cores and cost of providing and fixing bitumastic coated M .S. ties 450 mm long of 25x3 mm section at not less than 3 ties per Sqm as per approved design. ((DSR -6.6)) |
| 26 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand) ((DSR -6.13.2)) |
| 27 | Stone work in plain ashlar in super structure upto floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) including pointing with cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade.Both face dressedRed sand stone ((DSR -7.12.2.1)) |
| 28 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels.Granite stone slab of colour black, Cherry/Ruby redArea of slab over 0.50 Sqm ((DSR -8.2.2.2)) |
| 29 | Providing and fixing 18mm thick Granite stone work for wall lining at all height in cement mortar 1:3 (1cement : 3 coarse sand) including pointing with white cement mortar with an admixture of pigment to match the granite shade complete as per direction of Engineer-in-charge. (NSR) |
| 30 | Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : Red sand stone - exposed face fine dressed with rough backing .40mm thick ((DSR -8.14.1.4)) |
| 31 | Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required. ((DSR -8.15)) |
| 32 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per Sqm, including pointing in white cement mixed with pigment of matching shade complete. ((DSR -8.31)) |
| 33 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) noncorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws ((DSR -9.21.1)) |
| 34 | Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) On one side only ((DSR -9.22)) |
| 35 | Providing and fixing Acoustic Door with wood frame The door should be designed to provide effective sound insulation, adhering to acoustic performance standards suitable for the project\"s requirements with with panic bar on each shutter & vision pane should be 600x600mm, includind necessary fitting and fixtures in design and specification approved by Architect in charge (NSR) |
| 36 | DOOR 12MM Toughened with OZONE/or equivalent floor machine for 80 kg door weight including top bottom patch and lock ,handle using H type size 32*457,of Door size 4*8 complete to the satisfaction of Engineer in charge and as per drawing approvd by Architect in charge (NSR) |
| 37 | Providing and fixing S. S. sliding door bolts, ISI marked required colour or shade, with nuts and screws etc. complete : 250mm x 16mm . (NSR) |
| 38 | Providing and fixing S. S. tower bolts with necessary screws etc. complete : 150x10 mm. (NSR) |
| 39 | Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. 125 mm (NSR) |
| 40 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. ((DSR -9.83)) |
| 41 | Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete. ((DSR -14.34)) |
| 42 | Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerancein dimension i.e. in depth & width of profile shall be acceptable.\"Two track four panels sliding windows with Aluminium channel for roller track, wool pile, zinc alloy (Zamak) powder coated handle on three panels along with multi-point locking system, nylon rollers with SS 304 body.Using R3 series with frame (55 mm & above) x (40 mm & above) & sash (30 mm & above) x (55 mm & above) (Height upto 1.8m).\" ((DSR -9.147.A2.1)) |
| 43 | Float glass panes: 4 mm thick glass pane (weight not less than 10 kg/Sqm). ((DSR -9.7.7.1)) |
| 44 | Providing and fixing factory made P.V.C. door frame of size 50x47 mm with a wall thickness of 5 mm, made out of extruded 5 mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long rackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer’s specification and direction of Engineerin- Charge. ((DSR -9.119)) |
| 45 | Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC ‘C’ channel of size 30 mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the ‘C’ Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturer’s specification & drawing.30 mm thick plain PVC door shutters (NSR) |
| 46 | Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strikeplate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineerin- charge:Fixing with adjustable lugs with split end tail to each jamb ((DSR -10.14.2.1)) |
| 47 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). ((DSR -10.28)) |
| 48 | Providing and fixing Stainless steel finish 304 grade railing Ozone/or equivalent make 16 gauge with 10MM toughened glass balustrade round, flat or square inlcuding the cost of installation and all necessary fittings and fixtures; height 1200mm as per drawing approved by Architect in charge complete to the satisfaction of Engineer in charge (NSR) |
| 49 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thick ((DSR -11.26.1)) |
| 50 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. ((DSR -11.27)) |
| 51 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to 1S:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/Sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Double charge vitrified tile polished finish of sizeSize of Tile 800 x 1600 mm ((DSR -11.41A.1.4)) |
| 52 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ Sqm including grouting the joint with white cement & matching pigments etc complete.Size of Tile 800x800 mm ((DSR -11.46.3)) |
| 53 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent ((DSR -11.56.1)) |
| 54 | Providing and fixing machine made Bricks for Flooring Domestic Smooth where edges are sharp and borders are straight and Size of desire having Smooth surface finish with Compression Strength should be less than 105 kg/sq cm and Water absorption should not exceed 20%, on a bed of 12 mm cement mortar, to be laid in pattern as per drawing approved from Architect in charge including filling the joints with same mortar (make Prayag Clay Products or equivalent) (NSR) |
| 55 | Providing & Fixing of ornamental or printed handmade Terrazzo Flooring of Magnum Terrazzo Slabs in Self colour Mosaic (600x1000)MM with Thickness of 25MM in any desired shade and pattern including the cost of graphics design on multiple tiles as approved by Architect in charge .(Magnum-Buttercup Base with T4 White Chips & Jade Green Base with T4 White Chips) (Make : Bharat Flooring/Kalinga/Johnson or equivalent.) (NSR) |
| 56 | Providing and fixing three-layer construction, wooden plank/engineered Wood size 185—200 mm X 2000-2426 mm of 3 strip oak with a total thickness of 14 mm and a wear layer thickness of 3.5mm should be resandable up to 2 to 3 times as per shade and pattern approved by Architect in charge. Surface Treatment: Matt/ Ultra matt Lacquer, Core: Pine/ Spruce/ Alder. Joint: Woodloc 5S, fifth-generation locking system, Moisture Content as per EN 13183: 7%, Reaction to fire as per EN13501-2:1 Dfl- s1CARB 2 compliant, Biological Durability as per EN350-2 Class1 confirming to strict quality and environment norms. It should be certified by PEFC, FSC, Blue Angel, and Real Wood. Matching Accessories like skirting & profile with,. Installation should be done by a trained and authorized team on Zero level of the hard surface .Make-Kahrs, Armstrong (NSR) |
| 57 | Designing, engineering, fabricating, and finishing of customised inverted terracotta filler slab including the cost of moulding of different shapes of terracotta pots of size ranging from 300 to 600mm diameter and placing them on the inverted shuttering with sand filling at desired location as per approved drawing to the complete satisfaction of Architect in charge. (excluding the cost of RCC WORK) (NSR) |
| 58 | Providing & Fixing of Acoustical Suspended Ceiling System with Dune Max (Bevelled Tegular) Edge Tiles With Armstrong/Knauf15mm Exposed GRID. he tiles should have Humidity Resistance (RH) of 99%, NRC 0.7, Light Reflectance ≥85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 20mm , suitable for Green Building application, with Recycled content of 63%. he tile shall be laid on 32 with 15 mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 32mm and a load carrying capacity of 8.8 Kgs/M2 & pull out strength of 100Kgs. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system of Armstrong/Knaufmake. INSTALLATION: To comprise main runner spaced at 1200mm centres securely fixed to the structural soffit using Armstrong/Knaufsuspension system (specifications below) at 1200mm maximum centre. The First/Last Armstrong/Knaufsuspension system at the end of each main runner should not be greater than 450mm from the adjacent wall. Flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm centre to form 1200 x 600 mm module. Cut cross tees longer than 600mm require independent support. 600 x 600mm module to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200 mm cross tees. Perimeter trim to be Armstrong/Knaufwall angles of size 3000x19x19mm, secured to walls at 450 mm maximum centres as approved by Architect in charge; Anchor Fastener, Hanger Wire 2.5mm dia, Hook Clip with J Wire assembly/ or equivalent) (NSR) |
| 59 | Providing and Installation of 18mm of double Bison board with CNC cut as per detail and design approved by Architect in charge (NSR) |
| 60 | Providing and Fixing SoundScapes Shapes - Acoustical clouds which are 30 mm thick, (tentative area of single unit: 1200*1200) flat glass fibre panels of Humidity Resistance RH 95%, with embedded frame made of aluminium extruded section of 38X10mm of grade 6063-T6 as per dimension mentioned in below table for reinforcement and secured hanging in pattern, size, shape and finish as per drawing approved by architect in charge. Embedded extrusion shall have grub slot with pre inserted nut for group hanging and connected using Aluminium die casted corner connector with ¼” – 20 threading for hanging using cable adjuster for independent clouds. The form of SoundScapes Shapes - shall be Square / Convex / Concave / Circle / Hexagon / Trapezoid / Parallelogram (Left & Right) / Rectangle (Small & Large) in standard Traffic White color with light reflectance 90% as per ASTM 1477-98 or in the color specified by the Architect / Engineer in charge (Shell / Tangerine / Cranberry / Moss / Kiwi / Reef / Lagoon). The SoundScapes Shape shall be made of Glass fibre panel with density of 110-120 Kgs/m3 along with acoustical sound absorbing scrim on the face to achieve sound absorption as per below mentioned table in accordance with EN ISO 354 :2003 (average of 500-4000Hz). The face and edges shall be finished with matching water-based texture paint (NSR) |
| 61 | Providing and Fixing Woodworks Linear of nominal width 100mm, having 80mm wide panel with 20mm reveal having a thickness of 15mm thickness and length 2400 mm. The panel shall be made of a Moisture resistant fibre board substrate having a minimum density of 595 Kg/m3 with a laminated facing as per the approved shade (Portland Maple, Sea Beech, Siam Wood & Mystique Walnut) and a melamine balancing layer on the reverse side. The panel shall have 0.7mm PVC edge banding along the length side with a similar finish as that of the face. The back of the panel shall have a black acoustic felt to cover the reveal of 20mm to attain an NRC of 0.5 (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) as per ASTM C423. The panels shall provide a Humidity Resistance (RH) of 70% with camber limit less than 1mm/1000mm and bow less than 1mm/300mm. The back of the panels shall be profile-grooved to receive 3600mm special linear carrier (PeakForm Prelude XL Main Beam) with integrated factory fitted clips for installation. The panels shall be upward mounted on Main Bars with 24 mm wide T - section flanges having rotary stitching along the length of the beam with a web height of 43mm. The Main Beam shall have integrated (factory fitted) locking clips installed at 100 mm centre to centre distance. The deflection loading of the main beam tested as per ASTM C635 (Deflection limit less than L/360) shall be at least 21.4kg/m. The end details of the main beam shall be made of pre hardened steel and fixed to the ends with 3 point fixing. All main beam to main beam connection shall have a pull out strength of more than 100kg. The T Sections shall be made of hot dipped galvanized steel of 100 gsm as per IS 277 (2003) and pre-painted steel with baked polyester paint with 0T bending capability. Installation should be carried out as per Knauf recommended procedure. The grid shall be installed with suspension system of Knauf make. (NSR) |
| 62 | Providing & fixing Vertical Linear Baffle Ceiling made out of Aluminum Extrusion in Aluminum alloy grade 6063 in pattern, shade in customisable shapes, inlducing the cost of design and preparation of parametric waves etc. as per the drawing approved by Archiect in charge. The baffle blade shall be in size of 100x25x3600mm in powder coated to Woodgrain finish – Red Oak & Cherry. The baffle blade shall be suspended using Slotted U-profile at on-center spacing in multiples of 25mm(C To C-200 ) Longer lengths of Baffle to be connected by Baffle Joiner and the ends to be fixed with End caps. Installation of U-Grid: The U profile to be suspended at every 1200mm on-centre using 6mm threaded rod from the structural soffit using U-profile hanger. U-profile splice to be used to join more than one U profiles of length 3.75M. 1st U-Grid Channel must be no more than 400mm from the perimeter. Installation; Locate the slot for Baffle Hangers in U Profile section at 1200mm centres. Hangers are inserted into the slot, then rotated 90° and fixed into position by tightening the grub screw. Baffle to be lifted into position and hangers engage over lip of U-Grid Channel. Each Hanger to be secured into position by inserting the Locking Clip. When doing continuous installation, Baffles blades are to be connected at ends with Baffle Joiner, which are inserted into the top and bottom slots of the Baffle closed profile for alignment only. The bottom Joiner to be located first and fastened on one side only. The top Joiner to be fitted then and secured with grub screws on one side. Then the two Baffle sections shall be joined and the top Joiner is screw fastened on the 2nd Baffle profile. End Caps to be located by pushing the End Cap tongues into open Baffle slots.Installation to be carried out by Armstrong/KnaufTrained Installation team & Installation should be carried out as per Armstrong/Knaufrecommended procedure. (NSR) |
| 63 | 15 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement: 6 coarse sand) ((DSR -13.5.2)) |
| 64 | 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) ((DSR -13.4.2)) |
| 65 | 15 mm cement plaster on rough side of single or half brick wall of mix: 1:4 (1 cement: 4 coarse sand) ((DSR -13.5.1)) |
| 66 | Washed stone grit plaster on exterior walls height at all levels above ground level, in two layers, under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand ) with a mix ratio of 1:4 (1 part cement to 4 parts coarse sand) and tinted with the specified color, furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 2 Kg of cement per square metre, top layer 15 mm cement plaster 1:1/ 2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10 mm nominal size), in panels with groove all around as per approved pattern, including scrubbing and washing the top layer with brushes and water to expose the stone chippings ,complete as per specification and direction of Engineer-in-charge, including the cos tof forming grooves at required areas and finishing the surface in desired finish and texture. ((DSR -13.72)) |
| 67 | Supply and Laying a water soluble penetrative solution for waterproofing of masonry building material & Nano technology based as it provides molecular level hydrophobicity to inorganic substrate .The product is based on organosilicon chemistry, hence reacts with the inorganic substrate surface, seals the surface uto a depth of 2-3 mm and provides long service life where Nano size allows penetration deep into substrate that provides 20+ years water repellency.(Zycosil/Pratt & Lamber or Equivalent) including cost of all materials, labour tools and plants etc. required for proper completion of the work. (NSR) |
| 68 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :Two or more coats applied on walls @ 1.25 ltr/10 Sqm over and including one coat of Special primer applied @ 0.75 ltr /10 Sqm ((DSR -13.48.1)) |
| 69 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. ((DSR -13.8)) |
| 70 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 Sqm over an under coat of primer applied @0.75 ltr/10 Sqm of approved brand and manufacture ((DSR -13.48.2)) |
| 71 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 Sqm over an under coat of primer applied @ 0.80 ltr/10 Sqm of approved brand and manufacture ((DSR -13.48.3)) |
| 72 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :(a) First layer of slurry of cement @ 0.488 kg/Sqm mixed with water proofing cement compound @ 0.253 kg/ Sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/Sqm mixed with water proofing cement compound @ 0.126 kg/Sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. ((DSR -22.5)) |
| 73 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/Sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ Sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :22.7.1 With average thickness of 120 mm and minimum thickness at khurra as 65 mm. (NSR) |
| 74 | Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment. ((DSR -25.1)) |
| 75 | Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including:b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment , including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass. d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight.\"(e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge\" \"The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge.\" Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this sub- head. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves) on the external face shall be measured in Sqm. up to two decimal places. Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NABL accredited lab or any other accreditation body which operates in accordance with ISO/ IEC 17011 and accredits labs as per ISO/IEC 17025 \"1. Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr 2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range up to 2000 ml. 3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml 4. Structural Performance Deflection and deformation by static air pressure test (1.5 times design wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm 5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test, Tests to be conducted on site. 6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml\" (NSR) |
| 76 | Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.26.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in Sqm (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25-0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. ((DSR -25.3)) |
| 77 | Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- in- Charge. ((DSR -25.4)) |
| 78 | Providing and fixing 12 mm thick frameless toughened glass of approved brand and manufacturer, including fixing required fittings, all complete as per direction of Engineer-in-charge (NSR) |
| 79 | 12 mm Brick tile work for wall lining over required bed of cement mortar 1:3 (1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/Sqm including pointing in white cement complete. (NSR) |
| 80 | Artistic Mural & painting as per Design received from Architect Incharge. (Complete In All respect) (NSR) |
| 81 | \"Designing, providing and fixing parametric wooden cladding for exterior works using high-quality seasoned and chemically treated wood as per desing anddrawing approved by Architext in charge. The surface of the louvers shall be smooth and finished with a UV-resistant, weatherproof coating, such as water-based polyurethane or acrylic, providing protection against environmental factors and maintaining the natural aesthetics of Sheesham. The finish shall conform to EN 927 standards, ensuring long-term performance in outdoor conditions.\" The louvers shall be fixed onto a durable aluminum sub-frame system made of anodized or powder-coated aluminum alloy conforming to EN 485 standards. The sub-frame shall ensure proper alignment, structural stability, and resistance to wind loads as per IS 875 (Part 3). Concealed fasteners shall be used for fixing the louvers to maintain a clean and seamless appearance. The system shall be designed to accommodate thermal expansion and contraction without compromising the structural integrity.\"All materials used, including wood and coating, shall be tested for compliance with relevant standards. The coating adhesion shall meet GT0 standards as per ISO 2409, and the weatherproofing shall pass a 2000-hour weathering test as per ASTM G154. A Manufacturer’s Test Certificate shall be provided for all materials used in the cladding system.The installation of the Facade shall be carried out as per the manufacturer\"s guidelines and under the supervision of the Engineer-in-Charge, ensuring precision, durability, and aesthetic appeal. Upon completion, the cladding shall provide a visually striking and weather-resistant façade, suitable for long-term exterior use.\" (NSR) |
| 82 | Providing and fixing transition profiles \"SS floor trims\" at junction of various types of floor ,should be of 304 grade & 1.2mm thickness, PVD coating or electrofied coating & type as mentioned in detail drawings in desried shape and finish as approved by Architect in charge (joint of carpet with hard floor, joint of carpet with wooden floor, joint of hard floor with wooden floor etc) wherever necessary as directed by Engineer-site -incharge. Make : Bottomline,Profile (NSR) |
| 83 | Supply and installation of floor-mounted cable trays, designed for efficient cable management. The trays are constructed from stainless steel (SS202 / SS304) or aluminum with a thickness of 1.2 to 3mm, ensuring durability and resistance to corrosion. Each tray width ranging from 50 to 1000mm, and is available in multiple surface finishes including self-finish, pre-galvanised, powder-coated, and stainless steel. Installation must be performed by qualified personnel, ensuring proper alignment and securing of the trays to maintain load capacity and stability as per architect- in-charge (NSR) |
| 84 | Designing, Making, providing & installation of customised Metal make relief work as per approved design with Bronze color finish/ or any desired finish.The metal sheet thickness shall be approx. 6mm -8mm. Metal relief are a testament to the enduring allure of metal as a medium for artistic expression. This ancient alloy has been used for thousands of years to create works that capture the complexity of form and the subtleties of expression. They offer a unique aesthetic that combines the timeless elegance of bron with the expansive canvas of a mural, providing an opulent touch to any space. Material Bronze Ingots to be used for casting shall be directly sourced from reputed Metal Alloy Manufactureer. Approx Composition of the Alloy Copper 85%, Balance 15% to be an approved mix of Tin, Zinc and Lead. The installation with back MS frameworks/ or any pther suuiatble material required & transportation cost is inclusive. The steps of artworks shall be follows – clay works, casting, melting, molding joining (if any) finishing, transportation at site then final finishing with all frameworks, complete with patina of approved shade and size, as per the design approved by Architect incharge and directions of the Engineer-in-charge. Research: Complete and comprehensive research based on the advisory note, included in the tender. The work will include but not be limited to appointment of expert research team, travel, stay, food, meetings and consultation with subject experts, archival material identification, all consumables, printing, stationary, copies of films, drafts and preparation of a Content Document for submission to and as approval by the Architect in charge (NSR) |
| 85 | TOILET CUBICAL : For assembly, the system includes screws and plugs to secure the installation. The cubicle panels are made from 12mm T Line High Pressure Compact Laminate (HPL), which boasts exceptional resistance to water, chemicals, heat, bacteria, fire, impact, and scratches. This HPL is manufactured to a minimum density of 1350 kg/m³, with a warpage limit of 0.5% of its length, ensuring structural integrity and longevity.The installation process involves fixing the top rail end to end, with all mid and end pilasters anchored securely into it. The system design maintains a clearance height of up to 150mm from the floor, facilitating easy cleaning and maintenance. U sections are employed for board-to-board jointing and board-to-wall fixing, ensuring a stable and seamless assembly (Make: Jaquar, Toto, and Kohlar or equivalent) (NSR) |
| 86 | SERVICES CUBICAL : For assembly, the system includes screws and plugs to secure the installation. The cubicle panels are made from 12mm T Line High Pressure Compact Laminate (HPL), which boasts exceptional resistance to water, chemicals, heat, bacteria, fire, impact, and scratches. This HPL is manufactured to a minimum density of 1350 kg/m³, with a warpage limit of 0.5% of its length, ensuring structural integrity and longevity.The installation process involves fixing the top rail end to end, with all mid and end pilasters anchored securely into it. The system design maintains a clearance height of up to 150mm from the floor, facilitating easy cleaning and maintenance. U sections are employed for board-to-board jointing and board-to-wall fixing, ensuring a stable and seamless assembly (Make: Jaquar, Toto, and Kohlar or equivalent) (NSR) |
| 87 | Providing and fixing glassd canopy as per drawing attached . The glass should be attack resistant laminated safety glass of thickness 12 mm tested as per EN 356 for P6B level of attack resistant . The glass should be vetrogard attack P6B 15 mm clear laminated safety glass with light transmission of 85%. The glass should be compliant to 1B1 category of impact resistant as per EN 12600. with Frame section 200X100X6 mm and base plate 20mm thick 300X300 mm . The glass should be kept on 80density gasket with chemical sealnt and gap should be fixed with waterproofing sealant as direction of engineer incharge (NSR) |
| 88 | Supply of Natura Green Wall modules of Size 700mm x 500mm fabricated with Coir hard board of 6mm thickness with a filling cavity of 30 mm of sufficient quantity to cover the required area. Modules to be filled with Natura Super Absorbent Polymer Substrate. Faceof the Module to have 61 mechanically drilled holes of 35 mm Dia. Plants to be preselected as per site conditions, planted on the individual modules and nurtured for a period of 45-90 days. Back of the module to be fitted with 4 Aluminum Hooks sufficient to install on 35mm GI channels fitted onto the wall or to be installed on a pre-fabricated MS frame. 16 mm irrigation pipes fitted with drippers and automated using a battery based timer to be installed for the purpose of irrigation. Basic PVC Drain to be fitted at the bottom for collection of excess water if any as per drawing aporved by Architect in charge (NSR) |
| 89 | Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100mm upto 200mm in RCC beams, lintels, columns and slabs to introduce steel bars for sunshades/balconies including fixing the steel bars in position using epoxy resin anchor grout of approved make but excluding the cost of reinforcement, all complete as per direction of Engineer-In-Charge.Upto and including 12 mm dia. ((DSR -26.30.1)) |
| 90 | Providing and injecting HM-500 Epoxy Anchoring Type: HM-500 : Red or Black Density: 1.5±0.1g/cm³ in proportion Mix Ratio: 3:1 Color/ or recommended by the manufacturer into drills cracks/honey-comb area of concrete/masonry by suitable gun/pump at required pressure including cutting of nipples after curing etc. complete as per directions of Engineer-in-Charge. (make Hilti/HM or equivalent) (NSR) |
| 91 | Providing and installation of customised vertical concrete panels with precise dimensions and robust material specifications. Each panel measures 120 mm in width, 1500 mm in height, and has a thickness of 22 mm having flutes/grooves/undulation or of approved size of desired finish and pattern including the cost of graphics illustrations as approved by Architect in charge. The composition of tiles should be ‘43’ Grade Portland cement and homogeny pigmentation should be done with exterior grade synthetic inorganic iron oxide pigments manufactured by ‘BAYFERROX / Lanxess (Germany)’ or equivalent. The pigmentation should be homogeneous and in accordance with British Standards BS EN 12878:1999. The other additives should be fine washed graded quartz, super plasticisers and integrated water proofing agents and others. The tiles should be produced with high vibration technology and concrete mix design compressive strength equivalent to M-40 Grade@28 days. The top surface of the tiles should be sealed with in surface water absorption of tiles, less than 1% and water absorption by 24 hrs immersion method, less than 8%. The tiles should be applied on a rough plaster of 1:3 cement mortar 1:3 (1 cement: 3 coarse sand) and the fixing of tiles should be done by ‘Greyscale’ tile adhesive or equivalent as per manufacturer’s laying instruction. ln addition to thistiles will also have an inSert of L profile fixed using epoxy and screwed on the wallfor additional safety. The installation should be meticulously carried out under the guidance and approval of the appointed Architect or Engineer-in-Charge, ensuring that all work is executed to the highest standards of quality and precision. (NSR) |
| 92 | Design, fabricating, supply and installation of customised perforated MS sheet in extruded triangular or parametrically eveolved pattern as approved by drawing submitted to Architect in charge at all levels mild steel (MS) sheets, which includes a series of detailed processes to achieve the desired design and finish through CNC cutting, which allows for precise and intricate patterns to be cut into the MS sheet based on the approved drawings and designs provided by the Architect in charge. Following the cutting process, etching and engraving are performed to add depth and detail to the design, enhancing the ornamental appearance. These processes involve carefully removing material from the surface to create the desired patterns and textures. After the cutting, etching, and engraving are completed, refilling is conducted to ensure the engraved areas are smooth and consistent with the overall design. This step ensures that the intricate details are highlighted and any imperfections are corrected. The MS sheet used for this work will be of an approved thickness to ensure structural integrity and durability. Additionally, the specification includes the cost of powder coating the MS sheet in an approved shade. (make Metaguise/Citadel/ Woodform Architectural or equivalent) (NSR) |
| 93 | Design, Fabrication & Installation of 4 mm thick exterior grade PVDF coated aluminium composite panels of ALUCOBOND having 0.5 mm thick aluminium PVDF coated sheet available in standard colours + 3 mm core material + 0.5 mm aluminium sheet chemically treated ( back sheet ) bent as per requirement, fitted on anodised aluminium necessary coated rectangular grid work, hardware, fixtures,brackets, anchor, fasteners of S.S. 304 grade etc. complete duly sealed with weathering silicon manufactured by DOW corning / G.E. silicon for circular columns and curved beams etc complete. All section for supporting ACP shall be of size 50 x 50 x 2.5 mm at a distance of 1.2 m Horizontally & Vertically or as per requirement of the design shop drawing has to be submitted by the contractor for the approval of structural Engineer. a) For Terrace b) For Entrance Canopy (NSR) |
| 94 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size600x500 mm with integral type foot rests (NSR) |
| 95 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid ((DSR -17.2.1)) |
| 96 | Providing and fixing of wall mounting type water closet of approved quality & make and as per the direction of Engineer-in-charge. (NSR) |
| 97 | Providing and fixing of S.STEEL TOILET PAPER HOLDER(WITH FLAP) of approved quality & make and as per the direction of Engineer-in-charge. (NSR) |
| 98 | Providing and fixing of SANITARY BIN WITH PEDAL,18 LITERS, BLACK of approved quality & make and as per the direction of Engineer-in-charge. (NSR) |
| 99 | Providing and fixing of SWING HANDICAP GRAB BAR -S.STEEL, 32MM DIA. of approved quality & make and as per the direction of Engineer-in-charge. (for H. Toilet) (NSR) |
| 100 | Providing and fixing of S.STEEL GRAB RAIL,300MM,32MM DIA of approved quality & make and as per the direction of Engineer-in-charge. (for H. Toilet) (NSR) |
| 101 | Providing and fixing Hand Shower (Health Faucet) with 8mm Dia,1.2 Meter Long Flexible Tube & Wall Hook of approved quality and make as approved by Engineer - in - charge. (NSR) |
| 102 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. (NSR) |
| 103 | Providing and fixing of Under Counter Basin of approved quality & make and as per the direction of Engineer-in-charge. (NSR) |
| 104 | Providing and fixing of AUTOMATIC TAP, BASIN MOUNT of approved quality & make and as per the direction of Engineer-in-charge. (NSR) |
| 105 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer (NSR) |
| 106 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. ((DSR -17.22A)) |
| 107 | Providing and fixing of AUTO SOAP DISPENSER of approved quality & make and as per the direction of Engineer-in-charge. (NSR) |
| 108 | Providing and fixing of S.STEEL HAND DRYER (HEAVYTRAFFIC ) of approved quality & make and as per the direction of Engineer-in-charge. (NSR) |
| 109 | Providing and fixing of AUTOMATIC HRT TISSUE PAPERROLL DISPENSER of approved quality & make and as per the direction of Engineer-in-charge. (NSR) |
| 110 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. ((DSR -17.72)) |
| 111 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. ((DSR -17.31)) |
| 112 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.For Internal Toilet 15 mm nominal outer dia Pipes ((DSR -18.8.1)) |
| 113 | 20 mm nominal outer dia Pipes ((DSR -18.8.2)) |
| 114 | 25 mm nominal outer dia Pipes ((DSR -18.8.3)) |
| 115 | 32 mm nominal outer dia Pipes ((DSR -18.8.4)) |
| 116 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall 20 mm nominal bore ((DSR -18.7.2)) |
| 117 | 25 mm nominal bore ((DSR -18.7.3)) |
| 118 | 32 mm nominal bore ((DSR -18.7.4)) |
| 119 | 40 mm nominal bore ((DSR -18.7.5)) |
| 120 | Providing and fixing GI pipes complete with GI fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on WallTerrace loop & Tank Filling Pipe40 mm nominal bore ((DSR -18.10.5)) |
| 121 | 50 mm nominal bore ((DSR -18.10.6)) |
| 122 | Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality :20mm diameter pipe ((DSR -18.40.2)) |
| 123 | 25mm diameter pipe ((DSR -18.40.3)) |
| 124 | 32mm diameter pipe ((DSR -18.40.4)) |
| 125 | 40mm diameter pipe ((DSR -18.40.5)) |
| 126 | 50mm diameter pipe ((DSR -18.40.6)) |
| 127 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) :20mm diameter pipe ((DSR -18.46.2)) |
| 128 | 25mm diameter pipe ((DSR -18.46.3)) |
| 129 | 32mm diameter pipe ((DSR -18.46.4)) |
| 130 | 40mm diameter pipe ((DSR -18.46.5)) |
| 131 | 50mm diameter pipe ((DSR -18.46.6)) |
| 132 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :For vertical pipe connection with terrace ringmain20 mm nominal bore ((DSR -18.17.1A)) |
| 133 | 25mm nominal bore ((DSR -18.17.1)) |
| 134 | 32mm nominal bore ((DSR -18.17.2)) |
| 135 | 40mm nominal bore ((DSR -18.17.3)) |
| 136 | 50mm nominal bore ((DSR -18.17.4)) |
| 137 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :25 to 40 mm nominal bore ((DSR -18.13.1)) |
| 138 | 50 to 80 mm nominal bore ((DSR -18.13.2)) |
| 139 | Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./H.P.H.D. plastic ball.15 mm nominal bore, 105 mm long, weighing not less than 138 gms ((DSR -18.62.1)) |
| 140 | 20 mm nominal bore, 120 mm long, weighing not less than 198 gms ((DSR -18.62.2)) |
| 141 | 25 mm nominal bore, 152 mm long, weighing not less than 440 gms ((DSR -18.62.3)) |
| 142 | 40 mm nominal bore, 206 mm long, weighing not less than 690 gms ((DSR -18.62.4)) |
| 143 | 50 mm nominal bore, 242 mm long, weighing not less than 1240 gms ((DSR -18.62.5)) |
| 144 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. ((DSR -18.48)) |
| 145 | Providing, Fixing, Testing & Commissioning of XLPE Insulation of 9mm thickness on hot water supply pipes. Astral or equivalent approved complete in all respect as directed by Engineer-in-charge.15mm dia (9 mm thickness) (NSR) |
| 146 | 20mm dia (9 mm thickness) (NSR) |
| 147 | 25mm dia (9 mm thickness) (NSR) |
| 148 | 32mm dia (9 mm thickness) (NSR) |
| 149 | 40mm dia (9 mm thickness) (NSR) |
| 150 | 50mm dia (9 mm thickness) (NSR) |
| 151 | Supply, fixing, testing and commissioning of following Electrical Actuator Single Phase 220V AC Operated Wafer Type Butterfly Valve - IP65CB - 230VAC, as per specifications:-Lehry Make Automatic OHT Level Control System Consist of Following Items\"1) LEHRY Make On-Off Type Electrical Actuator Single Phase 220V AC Operated Wafer Type Butterfly Valve with CI Body & SS Disc 2) Level Float Switch- 5M 3) Control Box (a) IP 65 Finishing(250 x 160 x 115)mm (b) LED Lamps: Tank FULL, Tank EMPTY, Power (c) Power supply toggle switch (d) Accepts 230V Single Phase power supply and provides 24VAC to float switch and 230VAC to valve coil. (e) Accepts NO/NC feedback from float switch.\"40mm (NSR) |
| 152 | Providing and fixing MS pipe puddle flanges of required size with 600mm long with 6mm thick MS plate of size 300mm x 300mm of suitable size properly fixed in RCC walls of water tanks, including necessary welding complete in all respect as per details shown on darwings and directions of Engineeer-in-charge for water tanks.25mm dia. (NSR) |
| 153 | 40mm dia. (NSR) |
| 154 | 50mm dia. (NSR) |
| 155 | 80mm dia. (NSR) |
| 156 | 100mm dia. (NSR) |
| 157 | 150mm dia. (NSR) |
| 158 | 200mm dia. (NSR) |
| 159 | 250mm dia. (NSR) |
| 160 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm dia (for rain water) ((DSR -12.41.2)) |
| 161 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Single Push Fit Coupler110 mm dia ((DSR -12.42.2.2)) |
| 162 | Single tee with door110x110x110 mm ((DSR -12.42.3.2)) |
| 163 | Plain bend 87.5 deg110 mm dia ((DSR -12.42.5.2)) |
| 164 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm dia ((DSR -12.43.2)) |
| 165 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. ((DSR -12.22)) |
| 166 | Providing and fixing 15 cm wide, 45 cm overall semi-circular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete.0.80 mm thick with zinc coating not less than 275 gm/m² ((DSR -12.7.1)) |
| 167 | Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m.All kind of soil Pipes, cables etc. exceeding 80 mm dia . But not exceeding 300mm dia. ((DSR -2.10.1.2)) |
| 168 | Providing, fixing, jointing and testing, uPVC SWR pipes, - type B conforming to IS : 13592 to wall, ceiling and floor, approved quality, complete, for soil, waste & rain water drain including pushfit jointing with seal ring. (i) Single socketed pipes.Internal Toilet (Soil & Waste Pipe)75 mm (NSR) |
| 169 | 110 mm (NSR) |
| 170 | Exposed on Wall (Soil & Waste Pipe)110 mm (NSR) |
| 171 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion.Bend without door (45°)75mm (NSR) |
| 172 | 110mm (NSR) |
| 173 | Bend without door (87.5°)75mm bend (NSR) |
| 174 | 110mm (NSR) |
| 175 | Y\" Fitting without door75mm (NSR) |
| 176 | 110mm (NSR) |
| 177 | Single Tee without door75mm (NSR) |
| 178 | 110 mm (NSR) |
| 179 | Single Tee with door75mm (NSR) |
| 180 | 110 mm (NSR) |
| 181 | Bend with door (87.5°)75mm (NSR) |
| 182 | 110 mm (NSR) |
| 183 | Clean Out Plug (COP)75mm (NSR) |
| 184 | 110 mm (NSR) |
| 185 | Reduced \"Y\" Fitting without door110mm x 75mm (NSR) |
| 186 | Reduced Tee with door110mm x 75mm (NSR) |
| 187 | Coupler75mm (NSR) |
| 188 | 110mm (NSR) |
| 189 | Vent Cowl110mm (NSR) |
| 190 | Providing, fixing, jointing and testing, unplasticized PVC pipes - 10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete, for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc. For Wash basin & Urinal32mm dia. Pipe (NSR) |
| 191 | 50mm dia. pipe (NSR) |
| 192 | Elbow (45°)32mm (NSR) |
| 193 | 50mm (NSR) |
| 194 | Elbow (90°)32mm (NSR) |
| 195 | 50mm (NSR) |
| 196 | T fitting 32mm (NSR) |
| 197 | 50mm (NSR) |
| 198 | Coupler 32mm (NSR) |
| 199 | 50mm (NSR) |
| 200 | Providing, fixing, jointing and testing , of PVC Multi Floor Trap without jali of minimum 50 mm water seal, making necessary cutting in slab or floors and making good including supports with cement concrete 1:3:6 complete as approved by Engineer-in-Charge.110mm x 75mm x 50mm/40mm (Toilet) (NSR) |
| 201 | Providing, fixing, jointing and testing , of PVC Nahani Trap without jali of minimum 50 mm water seal, making necessary cutting in slab or floors and making good including supports with cement concrete 1:3:6 complete as approved by Engineer-in-Charge.110mm x 75mm (Toilet & Kitchen) (NSR) |
| 202 | Providing, fixing, jointing and testing , of PVC Multi Floor Trap Adaptor (Height Riser), making necessary cutting in slab or floors and making good including supports with cement concrete 1:3:6 complete as approved by Engineer-in-Charge.110mm x 50mm/40mm (NSR) |
| 203 | Providing and fixing PTMT grating of approved quality and colour.Rectangular type with openable circular lid 150 mm nominal size square 100 mm diameter of the inner hinged round grating (including balcony) ((DSR -18.58.2.1)) |
| 204 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design :150 x 100mm size P-type with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 ((DSR -19.4.2.1)) |
| 205 | Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete:100 mm diameter ((DSR -19.1.1)) |
| 206 | Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m. All kind of soil Pipes, cables etc. exceeding 80 mm dia . But not exceeding 300mm dia. ((DSR -2.10.1.2)) |
| 207 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design:100mm dia SW pipe ((DSR -19.2.1)) |
| 208 | \"Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)\"(a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-\"F\" insulation, conforming to IS-325.(c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.(d) Suitable cement concrete foundation duly plastered and with anti vibration pads.900 lpm at 35 m Head ((DSR -18.4.1)) |
| 209 | 450 lpm at 35 m Head ((DSR -18.4.2)) |
| 210 | Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. (for terrace booster pump) ((DSR -18.22)) |
| 211 | Providing & fixing of start/stop push buttons including complete connection etc. as required. (for terrace booster pump) (NSR) |
| 212 | Providing and fixing in position the industrial type pressuregauges with gun metal / brass valves complete as required (for terrace booster pump) ((DSR -16.8)) |
| 213 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :150 mm dia. ((DSR -18.11.6)) |
| 214 | 100 mm dia. ((DSR -18.11.5)) |
| 215 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :150 mm dia. ((DSR -18.14.7)) |
| 216 | 100 mm dia. ((DSR -18.14.5)) |
| 217 | Providing, laying, testing & commissioning of \"C\" class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :80 mm nominal bore ((DSR -18.7.6)) |
| 218 | 100 mm nominal bore ((DSR -18.7.7)) |
| 219 | 150 mm nominal bore ((DSR -18.7.8)) |
| 220 | Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Gunmetal ((DSR -18.9.1)) |
| 221 | Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.40 m ((DSR -18.17.2)) |
| 222 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Gun metal ((DSR -18.16.1)) |
| 223 | Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :Gun metal ((DSR -18.18.1)) |
| 224 | Providing and fixing standard fire mans axe with heavy duty insulated rubber handle. (NSR) |
| 225 | Providing of FHC Door made of 16 gauge MS Sheet with frame of size 105x70mm complete door and frame assembly including all hardwares (Concealed Flush handle,Allen Key Lock, MS Hinges, 5mm Thick Float glass) & accesories . The door to be painted with fire resistance paint. The scope shall also include the painting of the frame with the same paint as the shutter or complete as per direction of Engineer-in-charge.(Approx. size of door: 900mm Wide & 1500mm Height) (NSR) |
| 226 | Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. ((DSR -18.13)) |
| 227 | Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. ((DSR -18.2)) |
| 228 | Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. (NSR) |
| 229 | Supply and fixing of fire extinguisher, ABC Type 6.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. (NSR) |
| 230 | Providing and fixing Fire related signages printed on photoluminescent U1000 aluminium sheet of 1.0 mm (+-10%) containing Lumigen II as base chemical, covered under UV stablized coating and of appropriate size including fixing on wall, door, ceiling etc. with proper clamps, hangers, cleats, anchor fasteners etc. complete in all respects as directed by Engineer-in-charge. (NSR) |
| 231 | Providing and fixing of Kent Elite Plus Water Purifier (RO+UV+UF+TDS Control) with flow rate (50L/hr) including all its accessories, complete in all respect including testing etc. (NSR) |
| 232 | Supplying, installation, testing and commissioning of fire fighting suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) (NSR) |
| 233 | (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-\"F\" insulation, conforming to IS-325.(c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.(d) Suitable cement concrete foundation duly plastered and with anti vibration pads.SITC of cabling, swithces, fans etc. for electrical works (NSR) |
| 234 | Providing and fixing of wooden framed str with wooden panelling of 18 mm thick block board with 1mm thk. Decorative Laminate as per drawing and approval of architect in charge. (NSR ) |
| 235 | Providing and fixing of wooden framed str with wooden panelling of 18 mm thick ply wood with stucco paint design as per drawing and approval of architect in charge . (NSR ) |
| 236 | P& F Full Ht\" Hanging Display of MS pipe of 10mm with the finish of Physical Vapour Decomposed Coating with bending and welding design as per drawing and approval of architect in charge. (C-11) (NSR ) |
| 237 | Providing and fixing in position at required location, GRC (Glass reinforced concrete) bush box Planter of height 1.5m, 1.50m length,width 500mm as per Architect\"s Design and as directed by project architect with all leads and lifts etc. complete in toto. (NSR) |
| 238 | Supply and installation of CARA Bench, measuring L74 x W35 x H42 cm, is constructed from a unique polymer blend that mimics the appearance of stone while offering lightweight durability. This material is 100% recyclable and features UV stabilization to prevent color fading, making it ideal for both indoor and outdoor applications. The bench combines aesthetic appeal with practical functionality, ensuring long-lasting performance and environmental sustainability. (NSR) |
| 239 | Supply, Installation and Commissioning of Kitchen setup, architectrual lighting and furninture customisation in desired material, shade and finish including burners, SS baskets, SS Cabinets etc. complete as per drawing and design approved and recived from Architect in charge (NSR) |
| 240 | Supply, Installation and Commissioning of architectrual lighting customised in desired material, shade and finish including track, cove, breacket, wall light etc. complete as per drawing and design approved and received from Architect in charge including the cost of shop drawing prepration and sampling (NSR) |
| 241 | Providing and laying of printed saxony carpet of FloorMaster Brand, manufactured in Indonesia or equivalent, having 100% Type 6\" Nylon/Polyamide Crealon or equivalent and 1/10 gauge, . The carpet should have a primary backing of woven pp and secondary backing of weaveback to ensure high performance and comfort. The carpet should be of 4M width to ensure lesser joints and minimum wastage. It should have a minimum total weight of 1650 gsm and minimum pile weight 800 gsm , minimum number of tufts to be 185040 or more The carpet should also qualify to the following minimum European standards performance specifications - (a) Fastness to rubbing, dry (ISO 105 X-12), minimum rating should be 4-5; (b) Fatness to rubbing, wet (ISO 105 X-12), minimum rating should be 5; (c) Water fastness, (ISO 105 E-01), minimum rating should be 4-5; (d) Fastness to light (ISO 105 B-2), minimum rating should be 5; (e) Thermal Resistance (ISO 8302), minimum rating should be 0,072 m² K/ W; (f) Impact sound insulation (ISO 140 - 8), minimum rating should be 25dB. The carpet should be Scotchguard ready for better stain resistance, and should have an approved fire rating of Class 1 under Bf1S1 and should be recommended for commercial usage under Class 23/32 classification.\" duly installed on smooth hard floor with company recommended adhesive and underlay of 10 mm (NSR) |
| 242 | The end details of the cross tee shall be made of pre hardened steel and fixed to the ends of the cross tee to provide double locking between “cross tee to cross tee” and “cross tee to main beam”. All main beam to main beam and cross tee to cross tee connection shall have a pull out strength of more than 100kg. The T Sections shall be made of hot dipped galvanized steel of 90 gsm as per IS 277 (2003) and pre-painted steel with baked polyester paint with 0T bending capability(MAKE - Armstrong/ Nittobo/ Tranquil or Equiavlent) (NSR ) |
| 243 | Supply and installation of furniture suitable for both indoor and outdoor use as instructed by Architect in chargeReception Table Reception-1 (NSR) |
| 244 | Reception Chair (NSR) |
| 245 | Admin Block Seater Sofa (NSR) |
| 246 | Admin Block Centre Table Libra 1200X600 (NSR) |
| 247 | Bed & 2-No Bed Side Table, Without Mattress (NSR) |
| 248 | Ottoman ( Master Bedroom ) (NSR) |
| 249 | wooden console of size 1250x450x800mm (NSR) |
| 250 | Room Side Table Bed Side Table (NSR) |
| 251 | Providing & Installing Sofa 3+1+1 Seater, 3000x850x450 (NSR) |
| 252 | Room Centre Table Libra 900X600 (NSR) |
| 253 | Loose Chair (NSR) |
| 254 | Wall Mounted wooden console With White Indian Marble Counter Top (NSR) |
| 255 | Circular Centre Table 1000 mm Dia Wooden (NSR) |
| 256 | Side Table (NSR) |
| 257 | Toilet Vanity Size: 2300mm X 600 mm X 750mm (NSR) |
| 258 | Indoor Swing (NSR) |
| 259 | Wardrobe Size: 4000x3000x600 mm (NSR) |
| 260 | Wall panelling in 12mm HDHNSR With Laminate On Wall & Ceiling (NSR) |
| 261 | Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured).Suspended floors, roofs, landings, beams and balconies (Plan area to be measured)Upto 4.50 Mtr Height- G.F. (NSR) |
| 262 | Upto 4.50 Mtr Height -f.f. (NSR) |
| 263 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 Sqm over and including one coat of Special primer applied @ 0.75 ltr /10 Sqm ((DSR -13.48.1)) |
| 264 | Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 Sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 Sqm ((DSR -13.45.1)) |
| 265 | Two or more coats on new works including a coat of wood filler (0) |
| 266 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications:Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 Sqm over an under coat of primer applied @ 0.80 ltr/10 Sqm of approved brand and manufacture ((DSR -13.48.3)) |
| 267 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. ((DSR -4.17)) |
| 268 | Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 includinggrouting with cement mortar 1:4 (1 cement : 4 fine sand). ((DSR -6.44)) |
| 269 | Providing, laying and making kerb channel 30 cm wide and 50 mm thick with cement concrete 1:3:6 (1 cement: 3 coarse sand:6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth etc. complete and as per direction of Engineer-in-charge. (NSR) |
| 270 | DOUBLE SKIN or SINGLE SKIN ROOF SHEETING Providing & fixing Top layer of TRIMDEK profile sheet of 1015 mm effective cover width and nominal 28.5 mm deep ribs with subtle square fluting in the five pans at nominal 200 mm centre to-centre. The end rib shall be designed for anti-capillary action, to avoid any seepage of water through the lateral overlap. The feed material is manufactured out of nominal 0.50 mm Total Coated Thickness (TCT), Hi-Tensile steel with min. 550 mpa yield strength, metallic hot dip coated with Aluminum-Zinc alloy (55% Aluminum, 45% Zinc) as per AS 1397 - Zincalume AZ150 (Min. 150 gms/sq.mt total on both sides). Thereafter providing sub girt in 0.5 mm thickness in Z shape of 50 mm web and 20 mm flange over bottom skin sheet shall be Panel rib profile of LYSAGHT to be installed over purlins directly with self drilling & tapping screws. to make air gap of 50 mm for providing sandwich insulation of 50 mm thick rock wool pads having density of 48 kg/mtr cube with HDPE vapor liners on both top and bottom surface of Rock wool. Complete job with all hardware, accessories, material and labour. (NSR) |
| 271 | Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05 mm) with Zinc coating 120 gram per Sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Ridges plain (500 - 600mm) ((DSR -12.51.1)) |
| 272 | Gutter (600 mm over all girth) ((DSR -12.51.6)) |
| 273 | Providing and fixing mild steel round holding down bolts with nuts and washer plates complete. ((DSR -10.19)) |
| 274 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished seamless type tubes ((DSR -10.16.2)) |
| 275 | Providing and fixing false ceiling at all heights including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/Sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.]. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.|. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer’s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks) ((DSR -12.45.1)) |
| 276 | \"AUDITORIUM ACOUSTICAL FALSE CEILING Providing & Fixing of Knauf Fibre Glass Acoustical Suspended Ceiling System with 15mm thick Optra Microlook 90 Edge Tiles with Knauf Suprafine 15mm face exposed grid in pattern and design as approved by Architect in charge. The tiles shall have smooth laminated visual with Humidity Resistance (RH) of 95%, NRC 0.85 – 0.95 (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) as per ASTM C423 standard, , Light Reflectance ≥88% as per ASTM E-1477, Colour black, Fire Performance of Class 0/1 as per BS 476 Part 6/7 with 20/25mm Square Tegular/Microlook 90˚ edge and 8mm drop in module size of 600 x 600mm. It shall be suitable for Green Building application, with Recycled content of 85%.\"SUSPENSION: The tile shall be laid on Knauf Suprafine 32 with 15 mm wide T - section flanges colour global white having roll formed double stroke rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 32mm (all sections). The deflection loading of the system shall be 12.5 kg/m2 (as per standard installation layout mentioned below) and main beam tested as per ASTM C635 (Deflection limit less than L/360) with a deflection loading of 15kg/m. The end details of the cross tee shall be made of pre hardened steel and fixed to the ends of the cross tee to provide double locking between “cross tee to cross tee” and “cross tee to main beam”. All main beam to main beam and cross tee to cross tee connection shall have a pull out strength of more than 100kg. The T Sections shall be made of hot dipped galvanized steel of 90 gsm as per IS 277 (2003) and pre-painted steel with baked polyester paint with 0T bending capability. All border cross tee/main beam shall be levelled using perimeter fill.\"INSTALLATION: To comprise main runner spaced at 1200mm securely fixed to the structural soffit using Knauf suspension system (specifications above) at 1200mm maximum. The First/Last Knauf suspension system at the end of each main runner shall not be greater than 450mm from the adjacent wall along with the first and the last main beam shall be at less than 600mm from the wall.Flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm to form 1200 x 600 mm module. Cut cross tees longer than 600mm require independent support. 600 x 600mm module to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200 mm cross tees.Perimeter trim to be Knauf wall angles of size 3000x19x19mm, secured to walls using screws at 450mm centre to centre maximum.\"\"Installation shall be carried out as per Knauf recommended procedure.KNAUF SUSPENSION SYSTEM accessories supplied by Knauf consisting of M6 Anchor Fasteners with hanger hole, pre-straightened hanger wire of dia – 2.5 mm of 1.80 m length having a tensile strength of 344-413 MPa and a minimum loading strength of 110 kgs. (Optionally, adjustable hook clips made of 0.7mm thick Grade 1 C55 galvanized spring steel of dimension 100 x 20mm and 4 mm aquiline wire to be used for level adjustment during installation purpose in main runners); T- sections shall be pre- painted with polyster paint all complete including combination of Gysum board bands with cope light provision installed on GI metal frame work as per DSR norms at all heights as per specifications drawings & as directed by Engineer –in – charge at an height of 6 mtr in auditorium including scaffolding, lead lift taxes complete job with material & labour and L angle hanger of desire length. (MAKE - Armstrong/ Nittobo/ Tranquil or Equiavlent)\" (NSR) |
| 277 | Providing and fixing of Pendant Ceiling Features Fabricated in Acoustical Customised MDF Board with Acoustic Treatment. The features will be constructed using approved Medium Density Fiberboard (MDF) of specified thickness, shape , shade and design as per the drawinfg approved by Architect incharge. Each feature must be wrapped in acoustically transparent and aesthetically pleasing fabric, filled with environmentally friendly and fire-retardant acoustic treatment material. Compliance with approved design, industry standards, and adherence to aesthetic and acoustic specifications is essential during fabrication and installation. The selected contractor must implement rigorous quality control measures, including inspections and documentation of materialsd. SUSPENSION: The tile shall be laid on Knauf Suprafine 32 with 15 mm wide T - section flanges colour global white having roll formed double stroke rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 32mm (all sections). The deflection loading of the system shall be 12.5 kg/m2 (as per standard installation layout mentioned below) and main beam tested as per ASTM C635 (Deflection limit less than L/360) with a deflection loading of 15kg/m. The end details of the cross tee shall be made of pre hardened steel and fixed to the ends of the cross tee to provide double locking between “cross tee to cross tee” and “cross tee to main beam”. All main beam to main beam and cross tee to cross tee connection shall have a pull out strength of more than 100kg. The T Sections shall be made of hot dipped galvanized steel of 90 gsm as per IS 277 (2003) and pre-painted steel with baked polyester paint with 0T bending capability(MAKE - Armstrong/ Nittobo/ Tranquil or Equiavlent) (NSR) |
| 278 | WALL PANEL - WW CHANNELED: Providing and Fixing Channeled Woodworks perforated panels of width 192mm, thickness of 15mm and length 2400 mm, made of a Moisture resistant fibre board substrate with a laminated facing as per the approved shade (Portland Maple, Sea Beech, Siam Wood & Mystique Walnut, Interior White) and a melamine balancing layer on the reverse side in pattern and design as approved by Architect in charge, including the cost of all necessary panelling in all levels in suitable material (MS/wooden/Plyboard etc. as aprroved). The boards shall have a special perforation pattern where the reverse surface has a “Helmholtz” fluted perforation with consecutive 3mm wide groove followed by 13/21mm of visible pane. The edges of the panel shall be “tongue-and-grooved” to fix special clips for installation and seamless visual. The back of the perforated panel shall have sound absorbing non-woven acoustical fleece hot pressed to achieve NRC upto 0.6. (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) as per ASTM C423 and Humidity Resistance (RH) of 70% with camber limit less than 1mm/1000mm and bow less than 1mm/300mm.The panels shall be mounted on special aluminium splines (keel) using inside clips provided by Knauf and approved by the Architect/ Engineer-in-Charge.The panel shall be mounted by tongue and groove mechanism using inside clip on Knauf aluminium extruded keel made of Grade 6063-T5 having dimensions 3000(L) x 24(H) x 15.5(W). The keel shall also be used for transition of the butt end of adjacent panel at every 7.2m. To ensure specification of tiles, Manufacturers Test Certificate is required having complete site address & duly signed by Manufacturer. INSTALLATION: An appropriate vapour barrier (by others) shall be applied/installed on the vertical surface before the installation to properly seal against entry of any moisture. Vapour barrier (by others) shall be installed as per Manufacturer’s recommendation. Install wooden batten grid (provided byothers) of section 50x50mm or as approved by the Architect on the solid wall/partition to provide level and plumb surface for fixing Knauf Keel. Install Keel vertically using screws and plugs at spacing of not more than 600mm centre-to-centre. The first and last keel should not be more than 150mm from the ends. Trim the tongue of the first bottom panel and install using headless nail with groove side upward. Subsequent panels are installed with tongue side downward by engaging with each other using tongue and groove mechanism and secured by inside clip. Continue this process until required height is achieved. Shorter butt edges need to be joined using industrial/wood glue. The keel shall also be used for transition of the butt end of adjacent panel at every 7.2m. Install the Skirting (provided by others) of width 50mm or more as required by the Architect/ Engineer-in-Charge. Finish off the edges using wooden moulding of matching colour (by others). Installation should be carried out as per Knauf recommended procedure and designs approved by the Architect/ Engineer-in-Charge. (NSR) |
| 279 | Providing and Fixing of Acoustical Wall Panel with square edges made of fibre glass substrate 25mm thick, wrapped on the front side with an acoustically transparent fabric as per the approved shade (Husk, Copper, Sangria, Sesame, Coffee, Charcoal, Titanium, Flame, Peanut and Shell) in pattern and design as approved by Architect in charge, including the cost of all necessary panelling in all levels in suitable material (MS/wooden/Plyboard etc. as aprroved) . The panel shall be classified for Fire Class A, as per ASTM E-84. The Acoustical Wall Panel shall be of sizes 600x600mm (Nominal) or 600x1200mm (Nominal) and shall achieve an NRC of 0.85 (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) with 50mm airgap as per ASTM C423 to be fixed to wall on a framework of wooden battens and using Wall panel Impalers (supplied by the manufacturer) or by using construction adhesives (as per the instructions laid down by the manufacturer). The fibre glass substrate shall have a recycle content of 85%. INSTALLATION: An appropriate vapour barrier (by others) shall be applied/installed on the vertical surface before the installation to properly seal against entry of any moisture. Vapour barrier (by others) shall be installed as per Manufacturer’s recommendation. Install wooden batten grid (provided by others) of section 50x50mm or as approved by the Architect on the solid wall/partition to provide level and plumb surface. The Impalers shall be fixed to the battens using self-tapping screws, 3 nos. in case of 600x600mm and 4 nos. in case of 600x1200mm. Silica based construction adhesive (by others) to be dabbed on to the projecting elements (spikes) of the Impalers. Wall Panels shall be pierced through the spikes of the Impalers ensuring the line and level of the panels are maintained (NSR) |
| 280 | Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment. ((DSR -25.1)) |
| 281 | Automatic Door OZONE make working on sensor technology for heavy traffic area, with safety beam for 2mtr opening using 10m toughened glass , including installtion, weight of the door is 70-80 Kg, DC 24V 60W herical gear motor, 55-60 DB noise level, built-in motor lock and must be CE certified complete to the satisfaction of Engineer in charge. (NSR) |
| 282 | Providing and fixing stone jali 40 mm thick throughout in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali slab without any chamfers etc.Red sand stone ((DSR -7.33.1 )) |
| 283 | Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : Red sand stone - exposed face fine dressed with rough backing .40mm thick ((DSR -8.14.1.4)) |
| 284 | Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required. ((DSR -8.15)) |
| 285 | Providing and fixing copper pins 7.5 cm long 6 mm diameter for securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases. ((DSR -8.16)) |
| 286 | Supplying, fabricating, transporting, hoisting and fixing in position good quality of 70 mm Red sandstone in various elements for all levels. Stone shall be free from cracks, lines stains and even in shade for each element. The The stone shall be fine grained and reddish or buff-colored (locally available). The work shall be carried out as per attached drawings with different process of i.e carving (manual/ by machine), ornamental work, traditional work, figure work (any type, any size), CNC cutting, moulding. The carving and molding work shall be of very good quality. The stones to be fixed in line, level and plumb in all respect with the use of brass clamps, pins, (to be paid separetely) dowels, cement slurry with matching pigment and Epoxy of Akemi Germany, Ardex Endura, MYK laticrete or approved make as required and as approved by the Architects. (NSR) |
| 287 | Providing & Fixing of 1.6 mm thick M.S/Door Frame, Door capable of accommodating fire Hose Reel, Landing Valve, Hose Pipes, fittings & accesNSRies. The door shall have a front glass with lock and key arrangement & shall be painted with post office red colour (approval shall be taken on the basis of submitted sample before ordering) Cost of fire extinguishers not included in item rate. (Liasioing with civil contractor for making Recessed type mansoary box1500x900 mm (Indoor Cabinet) Only Frame (NSR) |
| 288 | 750x600x250 mm (Outdoor Cabinet) For Yard Hydrant (NSR) |
| 289 | Supply, installation, testing & Commissioning of Left & Right Main FOH speaker with a Biamplified, 2/3 Way Loudspeaker Array. Individual loudspeaker modules with in the array shall meet the following criteria: Usable Frequency Range (-10dB) of 50 Hz - 20 kHz and Continuous Power Handling of >=1000W LF + 200W MF-HF. There shall be LF driver of at least 2 x 8\" Low Distortion Transducers, 3\" VC - Ferrite voice coil or better . The Loudspeaker shall have a Max. SPL (Peak) of >=140 dB or better & Sensitivity sholud be 103 dB or better. It should have suitable Drivers for LF and MF/HF with Horizontal dispersion pattern of 120º or better (with multiple waveguide options, Vertical dispersion of the specker shall be 15-20 degrees or better. The loudspeaker module shall be comprised of a shall be of Marine Birchwood construction with IP55 weather rating (NSR) |
| 290 | Supply, installation, testing & Commissioning of OEM array frames/ Hanging/ Mounting arrangement for Suspension of upto 8-10 array modules offered above, Shall offer multiple rigging points for achieving desired pitch settings. (NSR) |
| 291 | Supply, installation, testing & Commissioning of a 2x18\" subwoofer Ultra Low Drivers, 4\" VC - Ferrite. The louspeaker shall meet the following criteria: usable Frequency Range (-10 dB) of 37 Hz - 200Hz or better. It should have an axial Sensitivity of > = 101dB (1W/1m) or more delivering a free field Max. Calculated SPL(peak) of >=144 db or better. The loudspeaker should have a nominal impedance: 4 ohm or more and continuous Power Handling of 2000W or more; Complete with installation as per the site requirement. (NSR) |
| 292 | Supply, Installation, Testing and Commissioning of High Performance Amplifier 3300W (1650 W X 2 channels @4 ohm); THD < 0.02%; damping factor > 400; inbuilt Sensitivity Selection - High Pass Cut Off - Stereo, Bridge, Parallel Switch, Signal to Noise Ratio (1 kHz, 8 Ohms)- 105 dB . (NSR) |
| 293 | Supply, Installation, Testing & Commissioning of Software Controlled Digital DSP with below Specifications:-Number of Inputs - 4,Number of Outputs - 8,Input Impedance - 12kΩ unbalanced, 24 kΩ balancedCMNSR - >45 dBAdjustable Delay - 1 second / input & 1 second / output (NSR) |
| 294 | Supply, installation, testing and Commissioning of 32-channel Mixer with Effects and Console (NSR) |
| 295 | Supply, Installation, Testing and Commissioning Wireless Handheld Microphone System, Wireless Microphone system with MHZ carrier frequency band, Up to 16 pre-programmed frequencies within the same frequency band, Audio bandwidth 35 - 20,000 Hz THD at 1 kHz: <0.3% (Receiver) , Signal-to-noise: 120 dB(A) ( Receiver), Wideband FM Modulation, Up to 48 Simultaneous channels , up to 14 hours operation with one single AA battery or better, Pilot Tone, transmission to know the transmitter battery status, Receiver should have microphone level and line level output, Transmitter should have display to show the battery and LED to show the Muted /Unmuted status Sensitivity 6.3 dB V / -100 dBm, Should have Microprocessor-controlled diversity, T.H.D.: 0.7 % (Transmitter), Infrared programmable, RF output power: 10 or 50 mW With Twin Channel True Diversity Wireless Receiver. offers users upto 16 simultaneous operating channels, over a PLL synthesized circuit and anti-interference support, True-Diversity dual channel receiver comes in a 19\" rack size and can be mounted using the rack mount accessory. The RF range for the receiver is 100m (Line of Sight)Approved Make: OSL/Sennheiser/Shure /or Equivalent (NSR) |
| 296 | Supply, Installation, Testing and Commissioning of Speaker Cable – 2.5 Sqmm (80/0.20mm) x 2 core cable ATC copper conductor PVC insulated, core twisted, outer jacketed with Vasiform Type PVC Sheath. (NSR) |
| 297 | Supply, Installation, Testing and Commissioning of 18 AWG microphone cable (24/0.20mm) x 2 core ATC copper conductor, PE insulated, core twisted in a circular form, Inner sheathed with moisture Proof Polymer, braid shielded (80%) with ATC copper, outer Jacketed with Matt finish Rugged Flexible PVC. (NSR) |
| 298 | Supply, Installation,Testing & Commissioning of 42 U Equipment rack to house all rack mountable equipment, with internal wiring, front glass door,heat dissipation fans,power distribution units (NSR) |
| 299 | SITC of HDMI Transmitter over Cat 6 ( HDBaseT) up to 70m with Input 1 HDMI, Cat6 (HDBaseT) Output, 4K@60 4:4:4 support HDTV Compatible, HDCP 2.2 Compliant with CEC, IR and RS-232, Compliance : CE, ISO 9001, ISO 14001, OHSAS 18001, etc complete as required. (NSR) |
| 300 | SITC of HDMI Receiver over Cat 6 ( HDBaseT) up to 70m with Input 1 Cat6 (HDBaseT), 1 HDMI Output, 1080p, 2K and 4K@60 4:4:4 support, HDTV Compatible, HDCP 2.2 Compliant with IR and RS-232, Compliance : CE, ISO 9001, ISO 14001, OHSAS 18001, etc complete as required. (NSR) |
| 301 | Supply and Laying of HDBaseT recommanded 23 AWG shielded CAT6A Cable with appropriate connectors in existing conduit.Make (NSR) |
| 302 | SITC of Diecast aluminum \"C\" clamp with safetylocking chain, duly powder coated in black matttexture finish and technical specifications as below.• Finish - Pretreated and black epoxy polyesterpowder• Safe working load – 150Kg. Make : Bezel/Martin/ETC/ROBE/PLS US /or Equivalent (NSR) |
| 303 | SITC of Safety bond with lock clip (Safe Working Load 100Kgs ) to be fixed around the grid to avoid fall of the material in case if the \"C\" clamp is not locked properly including all accessories etc complete as required. (NSR) |
| 304 | SITC of Identification name plate round 80mm undergone through 7 Tank chemical treatement to keep them rust free and duly powder coated in matt White texture finish including all accessories etc complete as required. (NSR) |
| 305 | SITC of MS Signal junction box made up of 22SWG CRCA sheet undergone through 7 tank process with various chemical treatment to keep them rust free, duly powder coated with Matt black texture finish 5 pin XLR DMX out connector of below specifications:-• All metal housing with RF protection &electromagnetic shielding• Connection to join pin 1 to chassis ground (NSR) |
| 306 | SITC of MS Signal junction box made up of 22SWG CRCA sheet undergone through 7 tank process with various chemical treatment to keep them rust free, duly powder coated with Matt black texture finish finish 5 pin XLR DMX in connector of belowspecifications:-• Connection to join pin 1 to chassis ground. (NSR) |
| 307 | SITC of DMX lighting junction loop box made up of 22SWG CRCA sheet undergone through 7 tank process with various chemical treatment to keep them rust free, duly powder coated with Matt black texture finish 5 pin XLR DMX in / out connector ofbelow specifications:-• Connection to join pin 1 to chassis ground. (NSR) |
| 308 | Supply, Installation, Testing and commissioning of 5 Pin XLR Male & Female Connectors for DMX network (NSR) |
| 309 | Supply, Installation, Testing and commissioning of 5 Pin XLR Termination Connectors for DMX network. (NSR) |
| 310 | Supply, Installation, Testing and commissioning of Black valcro tape for Cable dressing. (NSR) |
| 311 | SITC of Screened DMX signal cable for DMX network including terminations etc complete as required. (NSR) |
| 312 | SITC of Main Valence fixing arrangement using 40NB Pipe 2mm thick, 10 mtr in length MS pipe, undergone through 7 tank process with various chemical treatment to keep them rust free duly powder coated with matt black texture finish with mounting brackets to suspend the arrangement including all accessories etc complete as required Make : Bezel/Martin/ETC/ROBE/PLS US. /or Equivalent (NSR) |
| 313 | SITC of Main curtain track system 10 Mtr long, centre parting with overlap of 0.9mtr provided with, Heavy duty extruded aluminium I track of 48x84mm, powder coated Track mounting brackets constructed of C track of dimension 40X50X40mm Electromechanical drive unit with 3PH INDUCTION MOTOR, 1.1KW, 3000RPM, 90B5 FLANGE MOUNT with GI wire ropes of 3mm in diameter constructed with 7 bundles of 7 strands with steel core at center Curtain holding Nylon wheel trollies consisting of 4 wheeler master trolley and 2 wheeler trolley placed uniformly at specific interval of 200mm throughout the track.Nylon moulded 6201 Ball bearing Diverter pulley with with 90mm for outer diameter, 72mm diameter at groove base, 19mm pulley thickness & MS yellow passivated Routing pulleys with 165mm for outer diameter, 150mm diameter at groove base with 12mm pulley thickness including all accessories etc complete as required. Make : Bezel/Martin/ETC/ROBE/PLS US /or Equivalent (NSR) |
| 314 | SITC of Fixed Rear curtain track system 10 Mtr long, centre parting with overlap of 0.9mtr provided with,Heavy duty extruded aluminium I track of 48x84mm, powder coated Track mounting brackets constructed of C track of dimension 40X50X40mm with Curtain holding Nylon wheel trollies consisting of 4 wheeler master trolley and 2 wheeler trolley placed uniformly at specific interval of 200mm throughout the track including all accessories etc complete as required. Make : Bezel/Martin/ETC/ROBE/PLS US /or Equivalent (NSR) |
| 315 | SITC of Fixed Wing Structure designed as per site condition for a height approx 5 Mtr x 1.5 Mtr made up of MS Square tube of 25mm or higher size rested on pivotable trolley on a track for the rotation of the wing with all accessories as required. Make : Bezel/Martin/ETC/ROBE/PLS US /or Equivalent (NSR) |
| 316 | SITC of Fire retardant velvette fabric 100% (2 times of the finished dimension) gathering for main Valance as per the approved patern and colour, not less than 300 GSM, duly stitched along with and eyelets including all accessories etc complete as required.Size :L 10 Mtr x H 1.2 Mtr. Make : Bezel/Martin/ETC/ROBE/PLS US /or Equivalent (NSR) |
| 317 | SITC of MS Fabricated made up of 22SWG CRCA sheet undergone through 7 tank process with various chemical treatment to keep them rust free, duly powder coated with Matt black texture finish power junction box (PJB) to terminate the Motorized section power connections including all accessories etc complete as required. (NSR) |
| 318 | Variable Refrigerant Flow Air-conditioning System (Heating & Cooling)Supply, installation, testing and commissioning of Variable Refrigerant Flow modular type air-conditioning system suitable for Cooling & Heating both by scroll compressor controlled by inverter complete with indoor and outdoor units with individual/group wired and wireless/wired remote controller for indoor units and centralized controller, interconnecting refrigerant piping, full charge of refrigerant gas (R-410A) & oil, internal control cabling and fittings etc. as per details given in specifications and having following items. The out door units shall be suitable for 3 phase 4 wire system, 415V + 10 %, 50 Hz AC supply and indoor shall be suitable for Single phase 220-240V, 50 Hz AC supply. MAKE L G /HITACHI/CARRIERSupply of Outdoor Unit VRF ODU 22.0 HP (NSR) |
| 319 | VRF ODU 8.0 HP (NSR) |
| 320 | 348 .0 HP Heat pump type: (NSR) |
| 321 | VRF INDOOR UNITSupply of Indoor units address setting and capacity as mentioned below. multispeed motor, coil section with DX coil, outer cabinet, drain pan mechanism insulation, pipe connections and fresh air intake connector as per Hitachi specifications. (NSR) |
| 322 | SITC OF VRF DUCTED TYPE UNIT (NSR) |
| 323 | SITC OF VRF CASSETTE TYPE UNIT (NSR) |
| 324 | Installation of HVAC units, laying of pipes etc. complete (NSR) |
| 325 | Supply & Installation of AIR CURTAINAIR CURTAIN - Suitable for 3.5’ door opening with air displacement 3000 cfm. motor rating 1350 RPM, 1.5 H.P. 3PH Motor (NSR) |
| 326 | INSTALLATION OF VRF AIR CONDITIONING SYSTEM 430 HP Heat Pump Type (Cooling & Heating ) (NSR) |
| 327 | Providing and fixing HT danger notice plate 250 mm x 200 mm made of mild steel at least 2mm thick & vitreous enamelled white on both sides and with inscription in signal red colour on front side as required. ((DSR -2.22)) |
| 328 | Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :With common burnt clay F.P.S.(non modular) bricks ofclass designation 7.5 ((DSR -18.34.1)) |
| 329 | Supply, Fabrication & Installation of exterior directional sign board of size 750W X _ 1800H(Information panel) mounted on M.S. internal skeletal framework made out of M.S. box sections as detailed. All MS work should have one coat of primer and 2 | coats of Epoxy paint applied as per manufacturers instructions. The information panel shall be made out of 4mm thick Aluminium Composite Panel boxing of approved make and colour bent to curved/straight profile on both the sides as detailed. Graphic shall be printed on_ External Grade External Grade Vinyl and stuck to the main panel. The panel formed shall have overall minimum thickness of 90mm. The panel to have NLSIU Logo, Text in trilanguage, _— etc as detailed. The panel shall \" be fitted 150mm above ground level. Exposed part of the panel grouted to the foundation shall be clad with Flame finish steel grey granite, all complete as per drawings, specifications & directions of Engineer In Charge. The rate quoted shall include the cost of scaffolding, fixing and grouting if any, etc. Cost for Excavation, Concrete and_ granite cladding shall be paid separately under their respective items. (NSR) |
| 330 | Supply, Fabrication & Installation of exterior directional sign board of size 750W xX _ 1050H (Information panel) mounted on M.S. internal skeletal framework . made out of M.S. box sections as detailed. All MS work should have one coat of primer and 2 coats of Epoxy paint applied as per manufacturers instructions. The information panel shall be made out of 4mm thick Aluminium Composite Panel boxing (Di-bond / Aluco bond or approved equivalent make) of approved colour bent to curved/straight profile on both the sides as detailed in the drawing. Graphic shall be printed on External Grade Vinyl and stuck to the main panel. The panel formed shall have overall minimum thickness _ of 90mm. The panel to have : NLSIU Logo, Text in trilanguage, etc as detailed. The panel shall be fitted 150mm above pround level. Exposed part of the panel grouted to the foundation shall be clad with Flame finish steel grey granite, all complete as per drawings, specifications & directions of Engineer In Charge. The rate quoted shall include the cost of scaffolding, fixing, grouting and grouting if | any, etc.Cost for Excavation, Concrete and granite cladding shall be paid separately under their respective items. (NSR) |
| 331 | Over all Size: Height -240 inch, Width - 46 inch, Depth - 12 inch Exterior monolithic double sided signage fixed with the help of MS pipe frame work cladded with 3mm thick Aluminium composite panel (ACP) duly cut by CNC router with 5mm/12mm imported A- cast “Acrylite” make acrylic fixed with 040 acrylic sheet on back with exterior grade vinyl text, illumination with backlit water proof IP-68 rated LED inside for individual letter illumination complete in all respects as per design. The Foundation work with reinforcement: Foundation Size 5 ft (L) x 3ft (W) x 5ft (D) (12 mm & 10 mm dia reinforcement steel @ 150mm bothways as per approval of Engineer-in-Charge, to be used in foundation with grouting of MS base plate (16 mm thickness) with the help of 20 mm dia grouting bolt of length not less than 450mm. The nominal mix concrete of mix proportion 1:1.5:3 to be used in foundation. The MS Structure to be erected over 16mm thick MS base plate. The 2 nos MS pipe of size 150 x 75 x 5 mm to be fixed over base plate suitably braced with MS pipe of size 150 x 75 x 5 mm in between (04 nos: 01 no top, 01 no bottom and 02 nos in between) . Framing of MS pipe of size 25x25x5 over existing braced structure to be made on both side and thereafter, 50x50x5 mm square pipe to be fixed on side of structure in such a way to make provision for opeing on one side for maintenance purpose . ACP sheet – 3mm ACP sheet as per color approved by Engineer-in-Charge : Both side with side coverage as per design,approved size and approved MS structure. The ACP sheet to be cut by CNC router as per exact letter size & logo and as per approval of mock-up plan. Illumination: Illumination of not less than 140 lumens per feet, color temperature 10,000 K with IP68 grade power supply of SAMSUNG or equivalent make. 1)Logo of approximate size 42\" x 14\" on both side. 2) 12mm solid acrylic sheet laser cut letters-\"\" 3) 5mm solid acrylic sheet laser cut letters - 4) 12mm solid acrylic sheet laser cut letters of letter size 7 5) 5mm solid acrylic sheet laser cut letters- Note: 1) Matter on one side to be writen in Hindi font and on another side in English Font. 2) Matter as per tentative lay-out given. However, before actual execution, the bidder to take prior approval of mock -up plan from Engineer-in-Charge. (NSR) |
| 332 | Supply, Fabrication & Installation of exterior Informatory signboard of size 450W X 450H / 450 dia mounted on 50 mm dia M.S. _ Pipe Medium (B-Class), with : one coat of primer and 2 coats of Epoxy paint applied as per manufacturers instructions as indicated. The information panel shall be made out of 4mm thick Aluminium Composite Panel _ of approved make = and colour as detailed in the drawing. Graphic shall be printed on External Grade Vinyl and stuck to : the main. panel, all complete as per drawings, specifications . & directions of Engineer In Charge. The rate quoted shall include the cost of scaffolding, fixing, sprouting and grouting if any, etc.Cost for Excavation, Concrete shall be paid separately under their respective ‘items. Top of board shall be 1950 from Finished floor level. (NSR) |
| 333 | Supply, Fabrication &| Sqm Installation of cautionary signs of size as per | design made of 2mm thick Aluminium plate with Reflective External Grade Vinyl _ stickers, Fixed to surface using 3M tape, \"__ including necessary surface cleaning, all complete as per drawings, specifications & directions of Engineer In Charge. The rate quoted shall include the cost of scaffolding, fixing, etc. (NSR) Please Enable Macros to View BoQ information |
| 334 | Supply, Fabrication &| Sqm Installation of cautionary signs of size as per | design made of 2mm thick Aluminium plate with Reflective External Grade Vinyl _ stickers, Fixed to surface using 3M tape, \"__ including necessary surface cleaning, all complete as per drawings, specifications & directions of Engineer In Charge. The rate quoted shall include the cost of scaffolding, fixing, etc. (NSR) Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail