| 1 | Providing and laying Gypsum panel partitions 100 mm thick with water proof Gypsum panels of size 666x500x100 mm, made of calcite phosphor Gypsum fixed with tongue and groove edges and jointed with bonding plaster as per manufacturer’s specifications in super structure above plinth level up to floor V level. Gypsum blocks will have a minimum compressive strength of 9.3 kg/cm |
| 2 | Providing and fixing frame work for partitions/ wall lining etc. made of 50x50x1.6 mm hollow MS tube, placed along the walls, ceiling and floor in a grid pattern with spacing @ 60 cm centre to centre both ways horizontally) or at required spacing near opening, with necessary welding at junctions and fixing the frame to wall/ ceiling/ floors with steel dash fasteners of 8 mm dia, 75 mm long bolt, including making provision for opening for doors, windows, electrical conduits, switch boards etc., including providing with two coats of approved steel primer etc. complete, all as per direction of Engineer-in-charge. |
| 3 | Supplying & installing of ABC Type Fire Extinguisher Cap. 6 kg Filled with Mono Ammonium Phosphate Powder 50% confirms to IS 4308, Stored Pressure Type, UGTS Pressure Gauge, Discharge Time 24 Sec, Controllable discharge mechanism, Jet Range 5 Meters, Average Discharge is 92%, applicable on Class A,B & C and electrically started Fire, Fire Rating 4A:144B, Can Construction : Deep drawn & CO2 Mig welded, EPDM Rubber Hose with both end Aluminum clamped, Internal Coating - Epoxy Powder coating, External Coating - Pure Polyester Powder coating (UV Resistant), Brass forged valves with safety Pin is of SS material, Made up from 2mm thick sheet, ISI Approved IS 15683:2018 |
| 4 | Wiring for circuit/sub main wiring along with earth wire with the 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire sizes of FRLS PVC insulated copper conductor, single core cable including surface/ recessed medium class PVC conduit/ casing capping, bends and all fixing accessories as required. |
| 5 | SITC of AC point with 20 Amps 2 Pin + Earth (AS 20) reroll type metalic sockets- 1 NO / 20 AmpsDP MCB with separate Neutral link as controlling S/W - 1No./20 Ampsmetalic top- 1 No. for the above socket. |
| 6 | Supply and Fixing of 100W, LED Flood light fitting, IP-65/67 outdoor type |
| 7 | Supply % fixing of 22W,4\" long surface type LED tube lighting fixture |
| 8 | Supply & laying of 2.5 sqmm Cu wire |
| 9 | Supply & laying of 1.5 sqmm Cu wire |
| 10 | Providing & erecting distribution made out of 2 mm thick (in case of fabrication) MS CRCA sheet with concealed hinges, mounted on MS angle frame & grouted on the wall/fixed on the coloum with anchor fastener with earthing terminal, neutral link, interconnection with adequate size of Bus-bar/wires, interior of the DB shall be covered with 3 mm thickFRP sheet with necessary cut out, neoprene gasket, painting with seven tank metal treatment process. All as above for 63 amps TPN MCB--1 No. /// 40 amps DP ELCB(30 mA)--3 Nos /// 16 amps SP MCB (8 ways)--24 Nos. |
| 11 | Supply, installation, testing & commissioning of 1.1 KV grade PVC insulated stranded/ round wire armoured Copper/Aluminium conductor power cables ISI mark fixed on wall/ coloum/ ceiling or in shaft/existing trench on 5 mm thick spacers/ angle support fixed with screws/ coach screws/ anchor fasteners, all other fixing accessories etc. as per instruction of Engg.-in-charge. Cable will be 4 x 10 sq. mm copper conductor. Including lug, gland and all accessories. |
| 12 | 16 Amp,5 pin, switch socket combination board(Composite) |
| 13 | Supply & fixing of Cable Gland for 4 C x 10 sqmm cable |
| 14 | Supply & fixing of Lug for 4C x 10 sqmm Cable |
| 15 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed including medium class PVC conduit/casing capping, with modular switch, modular plate,suitable box , ceiling fan roseand earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. including PVC conduits, Bends, and all fixing accessories. Group A |
| 16 | Secondary point wiring light to light looping with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.including PVC conduits , Bends and all fixing accessories. |
| 17 | Supplying and fixing the 1 or 2 Modules, PVC box, modular base & cover plate for modular switches in surface / concealed, etc. as required. |
| 18 | Supplying and fixing the 8 Modules, PVC box, modular base & cover plate for modular switches in surface / concealed, etc. as required. |
| 19 | Supplying and fixing the 6 Modules, PVC box, modular base & cover plate for modular switches in surface / concealed, etc. as required. |
| 20 | Supplying and fixing the 6A/16A modular switch on the existing modular plate & switch box including connections etc. as required. |
| 21 | Supplying and fixing the 6A/16A modularsocket on the existing modular plate & switch box including connections etc. as required. |
| 22 | SITC of Cat 6 type I/O with RJ 45 socket in the provided Box, including faceplate, and fixing screws, having the compliance/certifications for ISO 9001:2015 & ROHS |
| 23 | SITC of Telephone socket (RJ -11) type with faceplate and fixing screws. |
| 24 | Supply & laying of CAT-6 cable through provided casing-capping, PVC conduit all as directed by EIC. |
| 25 | Supply & Fixing of 25 mm size PVC rigid conduit with spacers & saddles screws, rawal plug etc. along with all accessories complete in all respect on any hard surface/wall/trench/ceiling etc. Compete as per instruction of EIC. |
| 26 | Supply & Fixing of casing capping of 1.25Inch size with screws, rawal plug etc. along with all accessories complete in all respect on any hard surface/wall/trench/ceiling etc.Complete as per instructions of EIC. |
| 27 | Providing & installation of analoguetelephone instrument |
| 28 | Providing, fixing & commissioning of 1200 mm ceiling fan, colour as per requirement including down rod, double ball baring etc all as per instructions and as directed by E-I-C, ES. |
| 29 | Supply, fixing, testing and commissioning of the ceiling fan regulator on the modular plates. |
| 30 | Supply & fixing of 225 mm Ex-fan Metal/ PVC body with required accessories |