| 1 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres All kinds of soil. |
| 2 | Providing and laying stone soling hand packed including spreading ,watering and maintaining level Including cost of material involved complete. |
| 3 | Providing and laying in position cement concrete 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: Including cost of material involved complete. |
| 4 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering and shuttering. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)Including cost of material involved complete. |
| 5 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)Including cost of material involved complete. |
| 6 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete in sub-structure and super structure Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 7 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) Including cost of material involved complete. |
| 8 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:6 ( 1 cement : 6 coarse sand) Including Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level including all carriage |
| 9 | Centering and Shuttering including strutting, propping etc and removal of formwork in Foundations, footings, bases of columns etc. for mass concrete. |
| 10 | Centering and Shuttering including strutting, propping etc and removal of formwork in Lintel, beams, plinth beams, girders, bressumers and cantilevers. |
| 11 | Centering and shuttering including strutting, propping etc. and removal of formwork in Suspended floors, roofs, landings, balconies and access platforms. |
| 12 | Supplying and filling of RBM in plinth including spreading, dressing watering including all carriage and cost of material involved complete. |
| 13 | Providing woodwork in frames of doors, windows hoisted and fixed in position complete imported ( Imported Kailwood). Including Hold Fasts of complete. |
| 14 | Providing and fixing panelled or panelled and glazed shutters for doors, windows including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws 35mm thick. Imported kail wood. Including 4 mm thick glass panes with necessary fittings. |
| 15 | Providing and fixing 35mm thick wire guaze shutters using galvanised M.S wire guaze for aperture 1.4mm in both bdirections with wire of dia 0.63mm for doors, windows with hinges and necessary screws (Imported kail Wood) all complete. |
| 16 | Providing and fixing 4mm thick panes of plain glass including nails, beadings etc complete. |
| 17 | Providing and fixing of almunium fittings and fixtures ISI marked on doors and windows complete job as per directions of Engineer Incharge. |
| 18 | Tower bolt 100mm x 10mm |
| 19 | Tower bolt 150mm x 10mm |
| 20 | Handles 100mm |
| 21 | Handles 150mm |
| 22 | L-Drops with locking system |
| 23 | 12mm Cement plaster of mix: 1 : 6 ( 1 cement : 6 fine sand) |
| 24 | 6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand) |
| 25 | Providing and applying white cement based putty of specified thickness,of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2 mm thick |
| 26 | Finishing walls with acrylic smooth exterior paint of required shade on New work (Two or more coats applied @ 1.67 liter/10sqm over and including priming coat of exterior primer applied @2.20kg/10sqm) |
| 27 | Providing and applying priming coat on wood work with ready mixed grey or pink primer of approved brand and quality |
| 28 | Painting with synthetic enamel paint of approved brand and manufacturer of required colour to give an even shade. Two or more coats on new work over an under coat of priming coat. |
| 29 | Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 50 mm thick with 20mm nominal size stone aggregate. |
| 30 | Making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete. |
| 31 | Providing and fixing steel work in built up sections in angles, channels and plates of approved quality including two or more coats of primer of required colour of approved brand and manufacture including all carriage complete including soffit/eves (Welded). |
| 32 | Providing and fixing precoated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05%) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling / self tapping screws of size (5.5 × 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 33 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05%) total coated thickness, zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete: Ridges plain (500 – 600 mm). |
| 34 | Providing and fixing of angle iron door shutter with necessary fittings of complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. |
| 35 | Providing/laying conduits for electrical wiring, fan boxes, light boxes including bends all complete including binding conduits with binding wire. (Fan Boxes). |
| 36 | Providing/laying conduits for electrical wiring, fan boxes, light boxes including bends all complete including binding conduits with binding wire. (Light Boxes). |
| 37 | Providing/laying conduits for electrical wiring, fan boxes, light boxes including bends all complete including binding conduits with binding wire. (Conduits). |
| 38 | Painting with synthetic enamel paint of approved brand & manufacture to give an even shade 2 or more coats on new work for drawing 3D paintings (Like: Samagra Logo, School name with U-DISE Code and Executing agency name) & as per directions of the Engineer-in-charge complete. |
| 39 | Providing and fixing of 4 mm thick glass strips and 40 mm wide in cement concrete flooring of complete job. |
| 40 | Carriage for different materials: |
| 41 | Crushed aggregate average lead of 15 Kms |
| 42 | Sand average lead of 15 kms. Please Enable Macros to View BoQ information |