| 1 | Earth wk in excavation by mechanical means (hydraulic excavat) in trenches f foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and f shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil : |
| 2 | Providing & Laying of stone soling (dully hand packed)including watering dressing and ramming with all carriages loading un-loading and stacking etc complete |
| 3 | Providing & laying in position cement concrete of specified grade excld. The cost of centring and shuttering all wk upto plinth level(1:4:8 coarse sand 40mm nominal size crushed stone agg.) |
| 4 | P/L in position specified grade of reinfced cement cencrete excld. The cost of centring, shuttering, finishing and reinfecement-All wk upto plinth level. 1:1.5:3 graded stone agg. 20mm nominal size |
| 5 | Reinfced cement concrete wk in beams, suspended flos, roofs having slope upto 15°,landings, balconies, shelves, chajjas, lintels, bands,plain window sills, staircases and spiral stair cases upto flo five level excluding the cost of centring, shuttering, finishing and reinfcement with 1:1.5:3 ( 1 cement : 1.5 coarse sand : 3 graded stone aggregate |
| 6 | Providing & laying in position cement concrete of specified grade excld. The cost of centring and shuttering all wk upto plinth level 1:2:4 (1 cement 2coarse sand 4 20mm nominal size crushed stone agg.) |
| 7 | RCC wk in walls, including attached pilasters, buttresses, plinth and string courses, columns, pillars, abts, posts and struts etc upto flo 5 level excld cost of centering and shuttering, finishing and reinfcement 1:1.5:3 graded crushed stone agg 20mm nominal size |
| 8 | Centring and shuttering including proping, strutting & removal of the same for foundation footings base of columns etc. |
| 9 | Centring and shuttering including proping, strutting & removal of the same lintel , beams etc |
| 10 | Centring and shuttering incld. Strutting, proping etc & removal of form work for columns, pillars, piers, abutments, posts etc |
| 11 | Centring and shuttering incld. Strutting, proping etc & removal of form work for suspended floors, roofs, landings, balconies & access platefm |
| 12 | Brick work with FPS bricks of class designation 75 in super structure in cement mtar 1:6 (1 cement, 6 coarse sand) |
| 13 | Providing wood work in frames of doors, windows, cleresty windows & other frames, wrought framed & fixed in position Impted wood |
| 14 | Providing & fixing panelled panelled & glazed shutters for doors & windows and cleresty windows including ISI marked black enamelled M.S Butt hingeswith necessary screws excluding panelling ( imported wood) 30mm thick |
| 15 | Providing and fixing ISI marked flush do shutters confirming to IS: 2202 (Part I) decative type, ce of block board construction with frame of ist class hardwood and well matched teak 3 ply veneering with vertical grains cross bands and face veneers on both faces of shutters with ISI marked M.S presses butt hinges bright finished of required size with necessary screws |
| 16 | Providing & fixing of 40x5mm flat iron hold fast 40cm long including fixing to frameswith 10mm dia bolts nuts &wooden plugs and embedding in cement conc block 30x10x5cm 1:3:6mix (1cement:3coarse sand:6 graded st agg)20mm nominal size |
| 17 | 12mm Cement Plaster of mix 1:6(1 cement:6 fine sand) |
| 18 | 6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand) |
| 19 | Providing and laying vitrified flo tiles in different sizes (thickness to be specified by the manufacturer) with water absption less than 0.08% and confming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mtar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 600x600 mm |
| 20 | Providing glass panes 3.50 mm thick ) cleresty window shutters (Area of opening f glass panes excld ption inside shall be measured) |
| 21 | Providing and applying wall putty of 2mm thick over plaster surface (internal only) |
| 22 | Distempering with ist quality acrylic washable distemper (ready made) of approved brand and manufacture to give an even shade on New wk (two or more coats) |
| 23 | Finishing walls with acrylic smooth exteri paint of required shade on New wk (Two me coats applied @ 1.67 liter/10sqm over and including priming coat of exteri primer applied @ 2.20kg/10sqm) |
| 24 | Painting with synthetic enamel paint of app. Brand & manufacture to give an even shade 2 me coats on new wk incl applying priming coat: with ready mixed pink grey primer of approved brand and manufacture on wood wk( hard and soft wood) |
| 25 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 26 | Providing hardware items of standard make as per directions of EIC |
| 27 | L Drop |
| 28 | Towerbolts 100 mm |
| 29 | Handles 125 mm |
| 30 | Providing and fixing 4 layer 18 gauge (304) plain stainless steel railing of approved make jindal i/c pillar and boster on alternate steps equivalent i/c welding, polishing as per the directions of the Engineer in charge complete |
| 31 | Providing and laying of stone dust incl watering, ramming with all carriages, loading, unloading etc complete |
| 32 | Providing and laying Polished Granite stone floing in required design and patterns, in linear as well as curvilinear ptions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mtar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab jet Black, Cherry Red, EliteBrown, Cat Eye equivalent. |
| 33 | Making plinth protection 50 mm thick of cement concrete 1:3:6 with 20 mm nominal size aggrigates over 75 mm bed of dry brick ballast 40 mm nominal size well rammed, consolidated & grouted with the fine sand i/c finishing the top smooth and curing complete |
| 34 | Filling available excv. Earth(excld. Rock) in trenches plinth sides of foundation etc. layers not excd. 20cm in depth consolidating each deposited layer by raming and watering lead 50m and lift upto 1.5 mtr |
| 35 | Structural steel work in built up sections, trusses, framed wk incld cutting hoisting fixing in positon and applying a priming coat of approved steel primer all complete i/c soffits / eaves boarding (welded) |
| 36 | Providing crugated GS sheet roofing fixed with polymer coated J L hooks, bolts and nuts 8mm dia with bitumen and GI limpet washers upto a pitch of 60 degree excl cost of purlins, rafters and trusses 0.50mm thick with zinc coating not less than 275g/sqm |
| 37 | Providing ridges and hips of width 60cm overall width plain GS sheets fixed with polymer coated J L hooks bolts and nuts 8mm dia GI limpet and bitumen washers complete 0.50mm thick with zinc coating not less than 275g/sqm |
| 38 | Carriage of materails By Mech.Transpt, from source to site of wk |
| 39 | Stone agg. for an avg lead of 15 km |
| 40 | Sand for an avg lead of 15 km |
| 41 | Bricks for an avg lead of 15 km |
| 42 | Headload f an avg lead of 200m for Sand/Stone aggregates |
| 43 | Headload f an avg lead of 200m for Bricks |
| 44 | Electrification. |
| 45 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 2x1.5 sq.mm FRLS PVC insulated copper conductor Havell/Polycab/Anchor/eq,standard make as desired by engineer incharge ) single core cable in surface/recessed medium class PVC conduit, with modular switch (Anchor ramn plus/ Legand Mylinc /SSK NV/Schnelder/ABB Tvisho make) moduar plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable etc. as required.as approved by EIC. |
| 46 | Wiring for Light /Power Plug with 2 x 4 sq.mm+1x4 sqmm Earth wire,FRLS PVC Insulated Copper Conductor (Havell/Polycab/finolex/Anchor/equivalent as directed by Engineer-incharge) single core cable in surface/Recessed medium class PVC Conduit |
| 47 | Supplying and fixing suitable size GI Box with modular plate and cover infront on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A Modular socket outlet and 15/16 A modular switch, modular plate suitable GI Box connections etc, as required. Modular Switch & socket (Anchor roma plus/Legrand Myllnc/SSK NV/Schneider Lelya/ABB Tvisha make) same to be approvedby Engineer incharge. |
| 48 | Wiring for lighting Circuits/ inverter circuits/ 6-10 amp power plug with 2x2.5 sq.mm FRLS PVC insulated copper conductor (Havell/polycab/ Fenolex/Anchor/Equivalent as direted by Engineer incharge) single core Cable in surface/Recessed medium class PVC conduit along with 1 No 2.5 sq mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 49 | Supplying and fixing suitable size GI Box with modular plate and cover infront on surface or in recess, including providing and fixing 2 nos 3 pin 5/6 A Modular socket outlet and 2 nos 5/6 A modular switch, connections etc as required (for light plugs to be used in non residential buildings). Modular switch and socket (Anchor roma plus/Legrand Myllnc/SSK NV/Schneider Lelya/ABB Tvisha make) same to be approvedby Engineer incharge. |
| 50 | Supplying and fixing suitable size GI Box with modular plate and cover infront on surface or in recess, including providing and fixing 3 pin 5/6 A Modular socket outlet and 5/6 A modular switch, connections etc as required. |
| 51 | supplying installation testing and commissioning of indicator of Anchor roma plus/Legrand Mylinc/SSK NV Schnelder Livla/Crabtree athena make.) |
| 52 | Sub Head -2 Fixtures and fittings |
| 53 | Supply fixing testing and commissioning of backlite holder /batten holder/angle holder /ceilling rose SSK/Anchor make incl. PVC Block and 15 watt LED Lamp, Phillips/Trulux /Wipro make / sample to approved before installation. |
| 54 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, ceiling fan with 3 No. Aluminium blades, 30 cm long down rod, 2nos, canopies, shackle kit, Power Factor not less than 0.9, Service Value Including safety pin, nut bolts, washers, temperature rise-75 degree C (max.), Insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hx, and including iron hook complete. USHA/Havells/Crompton make ( sample to be approved before installation) |
| 55 | Supply and fixing of 6 amp/250 V AC fan dimmer step type 2 module with cover plate Anchor roma plus/Legrand Mylinc /ABB Thysha/schneider Livia/Havell Coral make. |
| 56 | S/F testing and comm. Of MCB\"s 10 K of the below mentioned capacities in sub main controls legrand C curve/ Schinidor/ABD /equivalent make as directed by engineer Incharge |
| 57 | 6-32 Amp SP MCB |
| 58 | 40-63 amp DP MCB |
| 59 | Supplying and fixing following way. single pole and neutral, sheet steel, MCB distribution board, legrand/Shtaider/lager mako) 240 V, on surface/ recess,complete with tinned copper trus bar, neutral bus bar, earth bar,din bar, interconnections, powder jpainted including earthing etc.as required. (But without MCB/RCCD/Isolator) |
| 60 | 24 way, Double door |
| 61 | Supply fixing testing and commissioning of backlite holder /batten holder/angle holder /ceilling rose SSK/Anchor make incl. PVC Block and 15 watt LED Lamp, Phillips/Trulux /Wipro make / sample to approved before installation. |
| 62 | S/L, testing and commissioning of PVC XLPE Insulated PVC (unarmoured) cable 650 V/1100 V Grade as per IS: (Part 1) 1988 with upto Date Amendments.Havell/Eq. standard make as directed by engineer Incharge and making end termination withs brass compression gland and aluminium lugs of required size. |
| 63 | 25 sq.mm 2 core Please Enable Macros to View BoQ information |