| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 mtr in width as well as 10 sqm on plan) in average fixed classification as, 85% All kind of soil, 10% Soft Rock & 5% Hard rock (Required blasting ) including disposal of surplus, excavated earth as directed by engineer- in-charge at site for safe disposal of same without damaging private/public property and all required leads/lifts and carriage. (Complete job) |
| 2 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts,wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil . |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering- All work upto plinth level.1:5:10 (1 cement: 5 coarse sand :10 graded stone aggregate 40mm nominal size) |
| 4 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)with 20% boulder |
| 5 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centenng. shuttering, finishing and reinforcement-All work upto plinth level.1.1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size) |
| 6 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. Layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering lead upto 50m and lift upto 1.5m. |
| 7 | Brick work with common burnt clay F.P.S.(non-modualar) bricks of class designation 75 in foundation and plinth inCement mortar 1 :4 ( 1 cement : 4 coarse sand) |
| 8 | Providing and laying damp-proof course 50 mm thick with cement concrete 1:2:4 (1 cement : 2 co.:Hse sand 4 graded stone aggregate 20mm nominal size i(A) Crushed |
| 9 | Applying a coat of residual petroleum bitumen of Grade VG- 10 of approved quality using 1.kg per square metre on damp-proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. |
| 10 | stone filling hand packed in horizontal level including the cost of the stone |
| 11 | Brick work with common burnt clay F.P.S.(non-modualar) bricks of class designation 75 brick work in superstructure above plinth level upto floor V level. (By manual means) |
| 12 | Reinforced cement concrete work in walls (anythickness), including attached pilasters, buttresses,plinth and string courses, fillets, columns, pillars,piers, abutmen\"ts, posts ans sturts, etc. upto floorfive level excluding cost of centring, shuttering, fmishing and reinforcement.1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded crushed stone aggregate 20mm nominal size) |
| 13 | Reinforcement for R.C.C. work including straightening,cutting, bending, placing in position and binding all complete.Thermo-Mechanically Treated bars. |
| 14 | Providing and laying Reinforced Cement Concrete 1:1.5:3 (1 cement: 1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size) in suspended floors, balconies, landings and staircase having upto 15° slope. excluding cost of centering and shuttering , all work upto floor V level |
| 15 | Cement concrete flooring 1:2:4 ( 1 cement: 2 coarse sand .: 4 graded stone aggregate) finished with a floating coatof neat cement including cement slurry, but excluding the cost of nosing of steps etc. omplete.25mm thick with 20mm nominal size stoneaggregate.(a) Crushed. |
| 16 | 6mm cement plaster to ceiling of mix 1 : 3 (1 cement: 3 fine sand) |
| 17 | 12mm Cement plaster of mix:1 : 6 ( 1 cement : 6 coarse sand) |
| 18 | Providing and applying white cement based putty ofaverage thickness 2 mm, of approved brand andmanufacture, over the plastered wall surface to preparethe surface even and smooth complete. |
| 19 | Applying one coat of water thinable cement primer ofapproved brand and manufacture on wall surfaceWater thinable Cement primer |
| 20 | Finishing walls with acrylic smooth exterior paint ofrequired shade on New work (two or more coats applied@ 1.67 litre/1 Osqm over and including base Coat ofwater proofing cement paint applied @ 2.20kg/1 Osqm) |
| 21 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately) sal wood |
| 22 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. Second class deodar wood |
| 23 | Providing and fixing wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge Second class deodar wood |
| 24 | Centring and shuttermg including strutting, propping etc.and removal of form for· |
| 25 | Foundations: footings, bases of columnsetc. for mass concrete. |
| 26 | Suspended floors, roofs, landings, balconiesand access platform. |
| 27 | Columns, Pillars, Piers, Abutments, Postsand Struts |
| 28 | Lintels, beams, plinth beams, girders,bressumers and centilevers. |
| 29 | Edges of slabs and breaks in floors andwalls.Under 20cms wide |
| 30 | Providing and fixing white vitreous china pedestal type water closet(European type) with seat and lid , 10 liter low level white vitreous chinaflushing cistern and CP flush bend with fittings and C.I. brackets, 40mmflush bend, overflow arrangement with specials of standard make andmosquito proof coupling of approved municipal design complete,including painting of fittings and brackets, cutting and making good thewalls and floors wherever required: |
| 31 | Providing c;1nd fixing oval wash basin withwith all fittings and fixture over grenite shelf with wash basin mixer including waste coupling waste pipe :White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps complete job |
| 32 | Providing and fixing mirror of superior glass( of approvedquality) and of required shape and size with wooden .moulded frame of approved make and shade with 6 mmthick hard board backingRectangular shape 1500X450MM |
| 33 | Providing and fixing 600x120x5mm glass shelf with edgesround of supported on anodised aluminium angle framewith C. P. brass brackets and guard rail complete fixedwith 40 mm long screws, rawl plugs, etc. complete |
| 34 | Providing and fixing toilet paper holderC.P. brass |
| 35 | Providing and fixing PTMT grating of approved quality andcolour.125 mm nominal dia with 25mm waste hole |
| 36 | Providing and fixing PTMT liquid soap container 109 mmwide, 125 mm high and 112 mm distance from wall ofstandard shape with brackets of the same materials withsnap fittings of approved quality and colour, weighing notless than 105 gms. |
| 37 | Providing and fixing PTMT towel ring trapezoidal shape215 mm long, 200mm wide with a minimum distance of37 mm from wall face with concealedfittingsarrangements of approved quality and colour, weighingnot less than 88 gms. |
| 38 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality andcolour:600 mm long towel rail with total lengthof 645 mm, 78 mm wide and effectiveheight of 88 mm, weighing not less than190 gms. |
| 39 | Providing and fixing C.P. brass bib cock of approved qualityconforming to IS : 8931 short body quarter turn of jaguar/cera superior quality NSI |
| 40 | Providing and fixing C.P. brass angle valve for basin mixerand gyser points _of approved make conforming to IS : 893115 mm nominal boreOf jaguar / cera superior quality nsi |
| 41 | Providing and fixing PTMT Waste Coupling for wash basinand sink, of approved quality and colour:Waste coupling 38mm of 83 mm lengthand 77 mm breadth weighing not less than 60gms. |
| 42 | Providing and fixing PTMT shelf 440 mm long , 124 mmwidth and 36 mm height of approved quality and colour,we1ghing not less than 300 gms. |
| 43 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer)pipes conforming to IS: 15801, UV stabilized and anti-microbial fusionwelded, having thermal stability for hot and cold water supply includingall PP-R plain and brass threaded Polypropylene random fittings. Thisincludes testing of joints complete as per direction of Engineer-incharge. External work including trenching, refilling etc. |
| 44 | PN-16 pipe , 25mm OD(SDR-7.4) |
| 45 | PN-16 pipe, 40mm OD (SDR-7.4) |
| 46 | PPR Union 40mm |
| 47 | UPV -P TRAP NSI |
| 48 | UPVC FLOW TRAP NSI |
| 49 | uPVC pipes (working pressure 4 kg / cm2 ) Single socketed pipe metre 75 mm dia |
| 50 | uPVC pipes (working pressure 4 kg / cm2 ) Single socketed pipe metre 177.00110 mm dia |
| 51 | uPVC pipes (working pressure 4 kg / cm2 ) Rubber (Seal) Ring 110 mm dia |
| 52 | UPVC coupler for UPVC drainage pipes 75 mm |
| 53 | UPVC coupler for UPVC drainage pipes 110 mm |
| 54 | uPVC single equal Tee (without door) 75x75x75 mm |
| 55 | Providing and fixing on wall face unplasticised - Rigid PVCrain water pipes conforming to IS : 13592 Type A includingjointing with seal ring conforming to IS : 5382 leaving 10 mmgap for thermal expansion. |
| 56 | 110 mm diameter |
| 57 | Providing and fixing on wall face unplasticised- PVC mouldedfittings/accessories for unplasticised- Rigid PVC rain waterpipes conforming to IS: 13592 Type A including jointing withseal ring conforming to IS : 5382 leaving 1 0 mm gap for thermalexpansion. |
| 58 | 110mm |
| 59 | 110x110x110 mm |
| 60 | Polyethylene water storage tank with cover and suitable locking arrangement complete job |
| 61 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 1.1.1 Group A |
| 62 | groop A |
| 63 | GROUP B |
| 64 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. |
| 65 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 66 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 67 | Supplying and fixing following modular switch/ socket on theexisting modular plate & switch box including connections butexcluding modular plate etc. as required |
| 68 | 5/6 A switch |
| 69 | 2 way 5/6 A switch |
| 70 | 15/16 A switch |
| 71 | 3 pin 5/6 A socket outlet |
| 72 | indicator 5/6 amp |
| 73 | blank plate |
| 74 | led tube light 4 feet long with one year warrety |
| 75 | Supplying and fixing two module stepped type electronic fanregulator on the existing modular plate switch box includingconnections but excluding modular plate etc. as required. |
| 76 | Supplying and fixing following size/ modules, GI box alongwithmodular base & cover plate for modular switches in recessetc. as required |
| 77 | 4 Module (125 mmX75 mm) |
| 78 | 12 Module (200 mmX150 mm) |
| 79 | 6 Module (200 mmX75 mm) |
| 80 | Supplying and fixing following way, horizontal type three poleand neutral, sheet steel, MCB distribution board, 415 V, onsurface/ recess, complete with tinned copper bus bar, neutralbus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)6 |
| 81 | 6/4 way (4+18) double door |
| 82 | Supplying and fixing following Modular base & cover plate onexisting modular metal boxes etc. as required. |
| 83 | 12 Module |
| 84 | 6 Module |
| 85 | 4 Module |
| 86 | Supplying and fixing brass batten/ angle holder includingconnections etc. as required. |
| 87 | Installation, testing and commissioning of ceiling fan, includingwiring the down rods of standard length (upto 30 cm) with 1.5sq. mm FRLS PVC insulated, copper conductor, single corecable, including providing and fixing phenolic laminated sheetcover on the fan box etc. as required. |
| 88 | supply and fixing of electric items suitable for operating 240/230 volts 50hz including connections |
| 89 | ceiling fan 1200mm sweep ( 5 star crompton greaves) |
| 90 | supply and fixing exhaust fan ceiling ventilation with sweep(200 mm) with exit pipe complete job |
| 91 | 12watt led builb |
| 92 | 50 litr gyser |
| 93 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator) |
| 94 | 8 way, Double door |
| 95 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 96 | Single pole |
| 97 | Single pole and neutral |
| 98 | service line three core aluminium thickness 35mm |
| 99 | carriages for the materials |
| 100 | sand for an avg. diatance of 150 km M.T |
| 101 | Aggregatesize below 40mm for an avg distance of 50km M.T |
| 102 | stone for an avg. distance of 10 km M.T |
| 103 | bricks for a distance of 160km M.T Please Enable Macros to View BoQ information |