| 1 | CIVIL WORK |
| 2 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 3 | 1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size. |
| 4 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : |
| 5 | 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) incuding manufactured sand derived from Recycled Concrete Aggregate (RCA) upto 20% : 3 graded stone aggregate 20 mm nominal size of Recycled Concrete Aggregate (RCA) upto 20%. |
| 6 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level. |
| 7 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 8 | Centering and shuttering including strutting, propping etc. and removalof form work for : |
| 9 | Foundations, footings, bases for columns |
| 10 | Boring with hydraulic piling rigs with power units, providing an installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured up to to the bottom of pile cap) : |
| 11 | 300 mm dia piles |
| 12 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 13 | Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) |
| 14 | Supply and fixing of Membrane Tensile Roof, Fabric BrandValmex Mehatop FR 700 Imported Fabric, Structure workMS 100dia round pipe, 3.6MM thickness, MS 80dia round pipe, 3.2MM thickness, along with MS plates, primer 1 coatand Epoxy paint two coated Manual for structure work(pipe)fabric fixing- aluminium top session profile and flat, self-drilling screw, fabric laying, cutting, welding, Tools &Equipment, Erection, all other accessories etc., IncludingLabour.( Including necessary hold fasteners ,bolt & nuts ,etc ,foundation bolt ,base plate ,etc. as per the instruction of engineer in charge . |
| 15 | Scaffolding for all types of work as per the direction of Engineer in charge |
| 16 | 12 mm cement plaster: |
| 17 | 1:4 (1 cement : 4 fine sand) |
| 18 | Brick work with common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 in foundation and plinth in: |
| 19 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 20 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift up to 1.5 m, as directed by Engineer-incharge. |
| 21 | All kinds of soil |
| 22 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. Meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the wallscomplete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge |
| 23 | With cement mortar 1:4 (1 cement : 4 fine sand) |
| 24 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 25 | 75 mm diameter |
| 26 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming toIS : 5382, leaving 10 mm gap for thermal expansion. |
| 27 | Coupler |
| 28 | 75 mm |
| 29 | Bend 87.5° |
| 30 | 75 mm bend |
| 31 | Single tee with door |
| 32 | 75x75x75 mm |
| 33 | Providing and laying 60 mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. |
| 34 | Taking out existing CC interlocking paver blocks from footpath/ centralverge, including removal of rubbish etc., disposal of unserviceable materialto the dumping ground, for which payment shall be made separately andstacking of serviceable material within 50 metre lead as per direction ofEngineer-in-Charge. |
| 35 | Laying old cement cocrete interlocking paver blocks of any design/ shapelaid in required line, level, curvature, colour and pattern over and including50 mm thick compacted bed of coarse sand, filling the joints with fine sandetc. all complete as per the direction of Engineer-in-charge. (Old CC paverblocks shall be supplied by the department free of cost). |
| 36 | Supplying and filling including ramming consolidated and dressing complete |
| 37 | Red gravel |
| 38 | Providing and laying in position cement concrete of specified grade excluding the cost ofcentering and shuttering - All work up to plinth level : |
| 39 | 1:1.5:3 (1 Cement: 1.5 coarse sand (zone-III) including manufactured sand derived fromRecycled Concrete Aggregate (RCA) upto 25% : 3 graded stone aggregate 20 mm nominalsize including Recycled Concrete Aggregate (RCA) upto 25%). |
| 40 | Painting with synthetic enamel paint of approved brand and manufactureof required colour to give an even shade |
| 41 | One or more coats on old work |
| 42 | Finishing walls with textured exterior paint of required shade : |
| 43 | Old work (Two or more coats on existing cement paint surfaceapplied @ 3.28 ltr/10 sqm. |
| 44 | Demolishing R.C.C. work manually/ by mechanical means includingstacking of steel bars and disposal of unserviceable material within 50metres lead as per direction of Engineer - in- charge |