| 1 | Description of Item |
| 2 | Microprocessor based fire alarm control panel, expandable to minimum 8 loops fully networkable with each loop capable of taking at least 126 devices with a min loop length support of 1500mtrs. The system should be in accordance with NFPA- 72 and UL/FM Listed approved or EN 54 with VDS/LPC approval.Electronics, power supply and batteries for continuous 8hrs operation with full load |
| 3 | Microprocessor based fire alarm control panel, expandable to minimum 4 loops fully networkable with each loop capable of taking at least 126 devices with a min loop length support of 1500mtrs. The system should be in accordance with NFPA- 72 and UL/FM Listed approved or EN 54 with VDS/LPC approval. Electronics, power supply and batteries for continuous 8hrs operation with full load |
| 4 | Microprocessor based fire alarm control panel, expandable to minimum 2 loops fully networkable with each loop capable of taking at least 126 devices with a min loop length support of 1500mtrs.. The system should be in accordance with NFPA- 72 and UL/FM Listed approved or EN 54 with VDS/LPC approval.Electronics, power supply and batteries for continuous 8hrs operation with full load |
| 5 | Microprocessor based repeater Panel |
| 6 | Intelligent Multisensor Addressable smoke detectors(Model - 58000-700 APO) |
| 7 | Intelligent Addressable Heat Detectors (Model - 58000-400APO) |
| 8 | Apollo Discovery Multisensor Detector Base (Model -45681-210APO) |
| 9 | LED type Response indicator having coloured LED lamp including connections etc.. |
| 10 | Addressable intelligent MCP (Model Ravel RE-716P1T ) |
| 11 | Mini Switch Monitor Module (Model -55000-760APO) |
| 12 | Apollo Addressable base sounder with Red Cap. (Model - 45681-277APO) |
| 13 | Relay modules for potential free contacts (Model - 55000-847SIL) |
| 14 | LHS Zone Interface Unit (Model - 55000-845APO) |
| 15 | Fault Isolator (Model - 55000-720APO) |
| 16 | Hardwarerequired for modification & interfacing with Mimic Panel |
| 17 | LHS cable |
| 18 | HMI PC/workstation withnecessary Graphical User Interface sofwares |
| 19 | Network components eg, FO converters, Patch cords, Ethernet Switches, LIU/Patch panels, Components for fiber termination etc. |
| 20 | Foldable Step Ladder 1) Min Height - 2mtr2) Min Height 4 mtrs (MOC - Aluminium) |
| 21 | Supply of Six core Single mode/ Multimode Fibre optic cable with PVC conduit for interconnection of all the SDS panels for looping Fire Control Room Panel-6 & APU SRR Panel-9 |
| 22 | Supply of 3Cx 2.5 sq.mm , 1.1 kV FRLS copper conductor flexible armoured cable with steel braided including connectors, PVC conduit etc.. as required |
| 23 | Supply of2Cx 1.5 sq.mm (14SWG), 1.1 kV grade flexible FRLS copper conductor armoured twisted cable with steel braided and overall shielded with aluminum mylar tape, including connectors, PVC conduit etc.. as required |
| 24 | TOTAL OF SUPPLY ITEMS |
| 25 | Description |
| 26 | Laying of 2Cx 1.5 sq.mm , 1.1 kV grade flexible FRLS copper conductor armoured twisted cable with steel braided and overall shielded with aluminum mylar tape, including connectors, PVC conduit etc. as required |
| 27 | Laying of Six core single / multi mode armoured fibre optic cable that integrates all the SDS control panel at Uran Plant with PVC conduit etc. and termination of all six cores of FO cables at respective locations. |
| 28 | Laying of LHS cable |
| 29 | Installation and Commissioning of new system & revamping of existing system that includes SDS control panels, Repeater panels, Smoke Detectors, MCPs, Hooters, Relay modules & LHS Zone Interface Modules etc. including Engineering, Configuring, Testing & Documentation etc. of the entire system as per the Scope of Work including Dismantling of the old system and shifting of all the scrap materials generated during execution of the work to the site designated by ONGC. |
| 30 | Revamping and Commissioning of Mimic Panel, 02 No HMI workstation, Network Switch, Processor Node or any other controller necessary for successful integration of all SDS control panel for centralized monitoring facility at Fire Control Room includingEngineering, Software Designing, Configuring, Testing & Documentation etc. of the entire system as per the scope of work. |
| 31 | TOTAL OF SERVICES = |
| 32 | Description |
| 33 | Charges for Post Warranty Comprehensive AMC, including supply of spares for 5 years (20 quarters) for Uran Plant & Trombay Terminal inclusive of applicable tax etc. as per scope of the comprehensive AMC for Intelligent Addressable Smoke Detection Systems (SDS). |
| 34 | ITEM |
| 35 | Excise Duty (if applicable) |
| 36 | GST on materials |
| 37 | GST on Service portion |
| 38 | Any other tax / duty |