Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 26-02-2026 | Amendment to BoQ | BOQ | 11-03-2026 |
| Sl. No. | Item Description |
| 1 | Chipping / removing loose concrete up to reinforcement bars, without damaging the reinforcement, removing all the loose materials and to make all the exposed surfaces free from oil, dust and all impurities etc. complete all as specified and directed. |
| 2 | M&L for removing all loose scale and corrosion deposits of the exposed corroded steel including surface preparation, corroded steel should be cleaned all around including the back of exposed reinforcement with the clearance/ gap between steel and concrete as recommended by manufacturer, then applying rust remover with brush by complete wetting the rusted material surface by rust remover and leaving for 24 hours and thereafter surface preparation of coated bars and applying 2nd coat of rust remover and leaving the same for the specific period as per manufacturer\"s instructions and further again preparing and cleaning the steel surfaces for treatment, complete all as specified and directed by the Engineer-in-Charge.Make :- Sika Rustoff 100 / Fosroc Rebacklens / BAS Emaco S420. |
| 3 | Providing and fixing rebar of 8/10/12mm dia TMT bars of required length and diameter with sika anchor fix @ 3+ fosroc lock fix / equivalent in BAS wherever required in RCC members including power drilling, cleaning of holes, then rebar should be inserted in the holes that should the filed with epoxy as mentioned above to ensure the bond as per manufacturer\"s instructions complete as per site requirement and as directed by Engineer-in-Charge. |
| 4 | Providing and fixing rebar of 16/20mm dia TMT bars of required length and diameter with sika anchor fix @ 3+ fosroc lock fix / equivalent in BAS wherever required in RCC members including power drilling, cleaning of holes, then rebar should be inserted in the holes that should the filed with epoxy as mentioned above to ensure the bond as per manufacturer\"s instructions complete as per site requirement and as directed by Engineer-in-Charge. |
| 5 | Corrosion Resistance Coating :- M&L for applying passivator / anti corrosion coating to the prepared reinforcement steel surfaces of relevant items mentioned here-in-above of this BOQ. The material shall be cement based polymer modified coating for corrosion protection and shall be applied as per manufacturer\"s instructions, complete all as specified and directed.Note :- Site for application is at various locations and height varies upto 15.0 Mtr. Cost for scaffolding and other means shall be deemed to include in the quoted rates.Make :- Sika Armatec 108 / Fosroc Nito cole AP-35 / Equivalent in BASF. |
| 6 | M&L for preparation of old RCC / concrete surface and applying a coat of (two components solvent free) epoxy bonding agent using brush after cleaning of surface from all dust or laitance complete all as per manufacturer\"s instructions and as directed by Engineer-in-Charge.Note :- Site for application is at various locations and height varies upto 15.0 Mtr. Cost for scaffolding and other means shall be deemed to include in the quoted rates.Make :- Sika Sikadur 32 LP / Fosroc Nitobond EP / Equivalent in BASF. |
| 7 | Providing and applying ready to use single component high strength polymer modified cementious repair mortar 25mm thick with water / powder ratio as specified by manufacturer so as to achieve the following parameters :-(i) 28 days Compressive Strength >= 50 N/mm2 (ii) Flexural Strength at 28 days>= 5 N/mm2Note :- Site for application is at various locations and height varies upto 15.0 Mtr. Cost for scaffolding and other means shall be deemed to include in the quoted rates.Make :- Sikatop 122 HS / Fosroc Nito Mortars / Equivalent in BASF |
| 8 | Curing Compound :- M&L for applying high efficiency water based film forming curing compound over the fresh concrete cementious surface to form a continuous non-penetraling coating providing a barrier to moislure loss ensuring more effcient cement trydration improved durability and reduced shrinkage. Teh compound shall be applied by sprayer only as per manufacturer\"s instuctions to ensure complete and proper coverage, pump pressure should be maintained to give an even fine spray and finish as per the manufacturer\"s specification and as directed by Engineer-in-Charge. |
| 9 | Notes :- The rates quoted against serial item Nos 1.00 to 8.00 here-in-above shall includes the followings :-(i)The work shall be executed only through authorized applicator of manufacturer.(ii) All scaffolding work and safety measures such as provision of props and supports shall be of steel and extent of provision shall be to the entire satisfaction of GE.(iii) After obtaining approval of the makes of products the contractor shall give a letter from the manufacturer regarding the details of agency and name of person to be deployed for carry out repair & supervisor of work.(iv) The T&P shall be strictly as per manufacturer instruction.(v) Necessary jacks shall be errected to support various floors before exposing columns / beams for repair and it shall also be ensured that no damage is made to the existing structure during repair process & all safety norms shall be followed. |
| 10 | (vi) Contractor shall furnish a written guarantee for structural repairs carried out under above serial items of BOQ for a period of five years. An amount to the tune of 5% of total amount quoted against ser item Nos 1.00 to 8.00 or Rs. 50,000.00 whichever is less shall be held back from contractor\"s payment as security deposit against the guarantee period of 5 years from certified date of completion.Alternatively, the contractor may give interest bearing deposit in favour of GE (North) Udhampur for five year for the sum mentioned here-in-before which shall be refunded back after satisfactory completion of five year from date of completion. |
| 11 | (vii) Close vigil & promptness on the progress and joint measurement has to be ensured and Photographic evidence in Soft copy for complete repair process for each structural members shall be taken by contractor & handed over to GE.(viii) The Construction chemical/ Fibers to be used shall be of following approved brands :-(a) Sika(b) Chembond(c) Hilti(d) BASF(e) Dr.Fixit(f) FOSROC(g) CICO(h) STP Limited. |
| 12 | Taking down cement plaster of any description on brick work or stone masonry or cement concrete walls including raking out joints, hacking for key, scrubbing down with water, complete all as specified and directed. |
| 13 | M&L for 15mm thick rendering on fair faces of brick work or concrete surface or roof surfaces of any type in CM 1:4 with using water proofing compound including finishing the surface even and smooth without extra cement, complete all as specified and directed.Note :- WPC shall be measured and paid separately under relevant item of this BOQ. |
| 14 | Supply only integral water proofing compound. |
| 15 | M&L for 15mm thick rendering on other than fair faces of brick work or concrete surface in CM 1:6 including finishing the surface even and smooth without extra cement, complete all as specified and directed. |
| 16 | M&L for 5mm thick rendering on ceiling surfaces of concrete or brick work in CM 1:3, complete all as specified and directed. |
| 17 | M&L for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper over one coat of primer and 2-3mm thick wall care putty, complete all as specified and directed. |
| 18 | M&L for complete removal of old treated/ plastered surfaces of wall and applying two coats of oil bound distemper over a coat of primer over two coats of approved wall care putty, complete all as specified and directed. |
| 19 | M&L for preparation of new plastered surfaces of ceiling and applying two coats of white wash, complete all as specified and directed. |
| 20 | M&L for preparation of old plastered/ decorative surfaces of ceiling and applying two coats of white wash, complete all as specified and directed. |
| 21 | M&L for two coats water based premium acrylic smooth exterior emulsion of approved colour with silicon additive & colour stay technology, excellent drit pick up resitance with low VOC less than 50 gram/litre as per LEEDS specifications, Anti Algal properties in two coats @ 1.79 ltr (undiluted with water as per manutacturer\"s instructions applied with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI, allow 6-8 hrs to dry the surface in both the coats of paint over waterproof cement based putty exterior grade @ 1 Kg (undiluted) per Sqm of average thickness 1mm over the newly plastered surface of walls and sanding of the putty surface with mechanical wall sander (having mechnical vacuum mechanism having RPM not less than 1500, sanding pad of 240 Grit above, complete all as specified and directed. |
| 22 | M&L for two coats water based premium acrylic smooth exterior emulsion of approved colour with silicon additive & colour stay technology, excellent drit pick up resitance with low VOC less than 50 gram/litre as per LEEDS specifications, Anti Algal properties in two coats @ 1.79 Itr (undiluted with water as per manufacturer\"s instructions applied with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI, allow 6-8 hrs to dry the surface in both the coats of paint over waterproof cement based putty exterior grade @ 1 Kg (undiluted) per Sqm of average thickness 1mm over the old plastered surface of walls and sanding of the putty surface with mechanical wall sander (having mechnical vacuum mechanism having RPM not less than 1500, sanding pad of 240 Grit above including complete removal of existing treatment, complete all as specified and directed. |
| 23 | Demolition of cement concrete (un-reinforced) as in ground floor and paving, not exc 15cm thickness below or above GL, complete all as specified and directed. |
| 24 | Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc, complete all as specified and directed. |
| 25 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing and rubbish off the premises, complete all as specified and directed. |
| 26 | M&L for non skid ceramic coloured tiles of 7 to 8mm thick (square / rectangular), area of each tile exc 0.11 Sqm but not exc 0.18 Sqm as in floor, skirtings etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, laid/ fixed over and including 15mm thick screed bed in CM 1:6, complete all as specified and directed. |
| 27 | M&L for coloured glazed ceramic tiles of each size 300x450x7-8mm as on vertical surfaces of walls, dados, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, fixed over and including 10mm thick rendering on fair faces of brick / concrete surfaces in cement mortar 1:4, complete all as specified and directed. |
| 28 | M&L for 15-18mm thick Udaipur green or white marble slab as in floors, in shelves etc, bedded, jointed and pointed with white cement sturry mixed with pigment to match with slab including cutting and polishing, complete all as specified and directed. |
| 29 | M&L for 18-20mm thick machine cut kota stone slab flooring in single piece with morror polishing, as in floor, laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete, laid/ fixed over and including 15mm thick scceed bed in CM 1:3, complete all as specified and directed. |
| 30 | All as per serial item No. 29.00 here-in-above but as on vertical surfaces such as dados, skirtings etc, fixed over 15mm thick plaster in CM 1:4. |
| 31 | Taking down chowkats or frames (without taking off shutters from frame), area not exc 1.50 Sqm each including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fasts shall be finished identical to existing finish without any extra cost to Govt.), complete all as specified and directed. |
| 32 | Taking down chowkats or frames (without taking off shutters from frame), area exc 1.50 Sqm but not exc 4.00 Sqm each including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fasts shall be finished identical to existing finish without any extra cost to Govt.), complete all as specified and directed. |
| 33 | S&F pressed steel frames of size 125mm x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, complete all as specified and directed. |
| 34 | S&F pressed steel frames of size 105mm x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, complete all as specified and directed. |
| 35 | M&L for mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, water tanks staging, braces etc. complete, drilled for fixing of steel sheeting or other covering, doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive or steel sheeting or other covering, running rails and guides) and hanging, also fastening and fixing complete, confirming to Fe-410-W (Gde E- 250)Quality \"A\", complete all as specified and directed. |
| 36 | M&L for mild steel work for bands, straps, supports or stays for rainwater, ventilating pipes including bolts, if required, hooks (stay),heavy, for large gates, hook and pintle hinges, large hasps and staples, chains, hand made sliding bolts, clamps, hold fasts, wall ties, hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts two way and three way straps, plate washers and similar small articles, conforming toFe-290 Gde-E-165, complete all as specified and directed. |
| 37 | M&L for cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) as in lintels upto 1.5 mtr clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded for chamfered angles and throating, complete all as specified and directed. |
| 38 | S&F steel windows and ventilators, box type, comprised of tubular frame and shutters made out of 1.58mm thick MS steel tube factory made with glazing bars, glass glazed shutter (glass panes shall be measured and paid separately) with side hung shutters with steel handle and steel peg stay dovetailed of welded including 2 Nos tower bolts 150mm long for each leaf and 8mm square bar grills at spacing as shown on drg welded to F1 frame work including other fittings, hinges, handles tarred hold fasts PCC blocks etc. all as shown on drg No. CEUZ TD-1517/15 sheet1/3 to 3/3 including two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified directed. |
| 39 | S&F steel windows and ventilators, box type, comprised of tubular frame and shutters made out of 1.58mm thick MS steel tube factory made without glazing bars, guaged shutter (wire mesh shall be measured and paid separately) with side hung shutters with steel handle and steel peg stay dovetailed of welded including 2 Nos tower bolts 150mm long for each leaf and 8mm square bar grills at spacing as shown on drg welded to F1 frame work including other fittings, hinges, handles tarred hold fasts PCC blocks etc. all as shown on drg No. CEUZ TD-1517/15 sheet1/3 to 3/3 including two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, complete all as specified and directed. |
| 40 | M&L for mild steel framed work for grills, gratings etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work, conforming to Fe-290 Gde-E-165, complete all as specified and directed. |
| 41 | S&F plain framed, panelled shutter 35mm thick, 2nd class hard wood (two panel) with lock rail and panel of 9mm thick BWP commercial ply or 12mm thick veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS:1003 (Part I), kiln seasoned and chemically pressure treated, complete all as specified and directed. |
| 42 | S&F 35mm thick glazed and skeleton shutters, 2nd class hardwood, open rebated and prepared to receive glass, gauze etc. (without sash bars), edge of framing plain, chamfered or rounded, fitted with cut and mitred beds for securing glass etc, sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.20 (a), supplied and fitted to chowkats at site, complete all as specified and directed. |
| 43 | S&F in repair 18mm thick prelaminated particle boards, interior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination, fixed with screws as in shelves, cup board shutters etc, complete all as specified and directed. |
| 44 | Extra over rates for teak wood lipping, 6mm thick, fixed with nails, complete all as specified and directed. |
| 45 | S&F continuous (piano) hinges, mild steel bright finish or elcctroglavanised, width of flap 30mm when opened, complete all as specified and directed. |
| 46 | S&F locks, suitable for cupboard, drawer, Grade-I, size 75mm 4 lever, complete all as specified and directed.Make :- Harrison / Godrej / Link |
| 47 | S&F magnetic catcher of size 50x25mm and fixed in position with stainless steel screws, ISI marked, suitable for cupboard & rubber wood shutters, complete as per the sample kept in the office of Engineer-in-Charge. |
| 48 | S&F hasp and staple of 150mm size, safety type, aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with SS screws, complete all as specified and directed. |
| 49 | S&F stainless steel handle, fancy type, 150mm size and fixed in position with stainless steel screws, ISI marked, suitable for cupboard drawers, complete as per the sample kept in the office of Engineer-in-Charge.Make :- NU-LITE / CROWN / EURO / OXFORD / GLOBAL / KWALITY |
| 50 | S&F factory made solid panel PVC door shutter, 30mm thick (style), consisting of frame made out of MS tubes for top and bottom rail, MS frame shall be covered with heat moulded plain colour PVC \"C\" channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/ sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, suppling & fixing in the frame at site, complete all as specified and directed. |
| 51 | S&F solid PVC door frame of size 50mm x 47mm, made out of 5mm plain colour PVC sheet reinforced with MS Square tube in opening and fixed at site, complete all as specified and directed. |
| 52 | M&L for preparation of new wooden surfaces of any description, over 10cm in width or girth and applying two coats of synthetic enameled paint over a coat of pink primer, complete all as specified and directed. |
| 53 | M&L for preparation of new steel/ iron surfaces of any description, over 10cm in width or girth and applying two coats of synthetic enameled paint over a coat of red oxide zinc chrome primer, complete all as specified and directed. |
| 54 | S&F 3mm thick sheet glass, ordinary quality, fixed with oil putty not exc 0.50 Sqm in each pane, complete all as specified and directed. |
| 55 | S&F 3mm thick figured glass, pin head type and glazing with oil putty in squares not exc 0.50 Sqm in each pane, complete all as specified and directed. |
| 56 | S&F 250mm long mild steel siding door bolts, plate type, stove enamelled black with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate, complete all as specified and directed. |
| 57 | S&F 150mm long aluminium, anodised, barrel tower bolts of extruded section, complete all as specified and directed. |
| 58 | S&F 150mm long, extruded aluminium alloy handles, fabricated type, anodised, complete all as specified and directed. |
| 59 | S&F 100mm long butt hinges, medium weight cold rolled mild steel, complete all as specified and directed. |
| 60 | S&F galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or galvanised wire staples, complete all as specified and directed. |
| 61 | S&F 1st class hard wood small fittings, such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like including all necessary labours, articles not exc 200 Cucm, complete all as specified and directed. |
| 62 | S&F in replacement anodised aluminium alloy curtain rod of 19mm dia with and including brackets, stops, rollers, fixed with SS screws, complete all as specified and directed. |
| 63 | Demolition of brick work or stone masonry, built in cement mortar including all quoines, arches, pillars etc. but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified and directed. |
| 64 | M&L for brick work with sub class \"B\" bricks, old size, straight or curved on plan, exceeding 6 metre mean radius, built in cement mortar 1:6, complete all as specified and directed. |
| 65 | Demolition of reinforced cement concrete of any description and in any position, not otherwise specifically provided, complete all as specified and directed. |
| 66 | M&L for 25mm thick cement concrete 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregates) as in flooring and finished the surface even and smooth with using extra cement, complete all as specified and directed. |
| 67 | M&L for 50mm thick cement concrete 1:3:6 type C-1 (using 20mm graded crushed stone aggregates) as in plinth protection, laid in alternate ways (not exc 2.0 Sqm each) and finished the surface even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection, filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight, complete all as specified and directed. |
| 68 | Taking down eaves gutters and rainwater pipes, PVC pipes (any size or pattern) including all fittings, heads, shoes, bends, swan necks etc. (measured overall as fixed along the centre line over fitting and accessories), complete all as specified and directed. |
| 69 | S&F in replacement of 100mm dia cast iron floor trap with grating including jointing to Cl waste pipe including cement concrete 1:2:4 type B-1 for fixing, complete all as specified and directed. |
| 70 | All as per serial item No. 69.00 here-in-above but cast iron nahani trap. |
| 71 | S&F cast iron \"P\" or \"S\" trap suitable for 100mm dia cast iron pipe,complete all as specified and directed. |
| 72 | S&F 100mm bore sand cast iron soil, waste and vent pipes, in any length with or without ears with cement joints, laid in trenches or in floors, complete all as specified and directed. |
| 73 | S&F 100mm bore sand cast iron soil, waste and vent pipes, in any length with or without ears with cement joints, fixed to wall with MS clamps of suitable size, complete all as specified and directed. |
| 74 | S&F 75mm bore sand cast iron soil, waste and vent pipes, in any length with or without ears with cement joints, fixed to wall with MS clamps of suitable size, complete all as specified and directed. |
| 75 | S&F cast iron branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches, suitable for 100mm bore pipe, complete all as specified and directed. |
| 76 | S&F cast iron branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches, suitable for 75mm bore pipe, complete all as specified and directed. |
| 77 | S&F cast iron bends (any radius) with duck\"s foot or heel rest, suitable for 100mm bore cast iron pipe, complete all as specified and directed. |
| 78 | S&F cast iron bends (any radius) with duck\"s foot or heel rest, suitable for 75mm bore cast iron pipe, complete all as specified and directed. |
| 79 | S&F 100mm dia cast iron vent cowl, complete all as specified and directed. |
| 80 | S&F 100mm diacast iron diminshing piece, junction plain of any radius, fixed to Cl pipes in reducer, complete all as specified and directed. |
| 81 | M&L for treatment of sunken floor surfaces with 0.488 Kg/Sqm, first layer of slurry of cement mixed with acrylic based polymer modified cementitious composite compound @ 0.253 Kg/Sqm. This layer shall be allowed to be cured for 4 hours and then aplying in second layer slurry of cement @ 0.242 Kg/Sqm mixed with acrylic based polymer based modified cementitious composite compound @ 0.126 Kg/Sqm. This layer shall be allowed to be cured for 4 hours including demolition/ dismantling old/existing treatment with wire brusing and clearing the dust and foreign material before new treatment, complete all as specified and directed by Engineer-in-Charge. |
| 82 | S&F 32mm bore GI pipe, medium grade, fixed in sunken floor as spout, complete all as specified and directed. |
| 83 | S&F vitreous squatting pan \"Orissa\" pattern of size 580x440mm white with integral foot rests complete including trap, set in and provision of cement concrete as filling in sunken portion, complete all as specified and directed. |
| 84 | S&F in replacement 10 liters capacity PVC valveless syphonic action dual type, flushing cistern, low level, white with inlet ball valve, float, flush pipe of chromium plated brass tube of 32mm dia and handle including brackets, complete all as specified and directed. |
| 85 | S&F 110mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints, fixed to walls with MS clamps of suitable size, complete all as specified and directed. |
| 86 | S&F 110mm bore PVC (SWR) bends of any radius, complete all as specified and directed. |
| 87 | S&F in replacement PVC connection pipe of 15mm size with PTMT nuts of length 450mm, complete all as specified and directed. |
| 88 | S&F in replacement grating doom of 100mm dia of PTMT (Minimum weight 25 gms), complete all as specified and directed. |
| 89 | S&F in replacement grating doom of 125mm dia with waste hole of PTMT (Minimum weight 40 gms), complete all as specified and directed. |
| 90 | S&F in replacement wash basin with pedestal, vitreous china (flat back type), size 550mm x 400mm including cutting for and pinning in ends of brackets or erecting stand, complete all as specified and directed. |
| 91 | S&F in replacement 32mm dia waste coupling of CP brass (half or full threaded), complete all as specified and directed. |
| 92 | S&F in replacement single lever wall mixer, 3 in 1, with provn of over head shower & hand shower, telephonic type, brass, chromium plated, fancy type with capstan head handles with lettered \"hot and \"cold\", screwed down high pressure including CP brass wall flanges and necessary extension nipples, screwed for 15mm bore pipe connection with provision for both hand shower and over head shower, complete all as specified and directed.Make :- Jaquar Cat Part No. FUS-29281 / Cera Cat Part No. F 2007403 or equivalent of makes as specified in PS of this tender. |
| 93 | S&F in replacement centre hole mixer for mixing hot & cold water for wash hand basin, cast copper alloy with dual capstan heads, chromium plated, screwed down high pressure, with lettered \"Hot\" & \"Cold\" with long screwed shanks and fly-nuts, screwed for 15mm bore iron pipe, complete all as specified and directed.Make :- Jaquar Cat part No. SOL-6169B / Cera Cat Part QTF 2006461 or equivalent of makes as specified in PS of this tender. |
| 94 | S&F gun metal, globe or gate valves with iron wheel head, screwed both ends for 20mm bore iron pipe, complete all as specified and directed. |
| 95 | S&F 300mm size, ordinary rat tail rod pattern springs including roller and roller plate, fixed to wooden or steel frames with screws or welding etc, complete all as specified and directed. |
| 96 | S&F in replacement stop valves, brass, fancy type with flange, chromium plated with long shank and cup (concealed type), screwed down high pressure, with capstan head handle, screwed both ends for 15mm bore iron pipe or unions, complete all as specified and directed.Make :- Jaquar Cat Part No. CQT-23083 / Cera- F 1014751 for exposed part & F 4060102 for consealed part or equivalent make as listed in PS as approved by GE. |
| 97 | M&L for RCC 1:1.5:3 (Nominal Mix) type A-1 (using 20mm graded crushed stone aggregates) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and the shelves including 15mm thick plastering mixed with water proofing compound, laid/ made to slope as in RCC roof surfaces, complete all as specified and directed by Engineer-in-Charge. |
| 98 | S&F in replacement 20mm dia brass chromium plated tubular towel rails, \"D\" type, 60cm long between flanges, complete all as specified and directed. |
| 99 | S&F in replacement brass chromium plated towel ring, round of 200mm dia, fixed with SS screws, complete all as specified and directed. |
| 100 | S&F glass shelf assembly consisting of 5.5mm thick sheet glass shelf, 12cm wide with chromium plated bracket guard and railing 60cm long, complete all as specified and directed. |
| 101 | S&F in replacement kitchen sink with drainage board, made of stainless steel 1mm thick, overall size 915mm x 460mm, bowl size 410mm x 330mm x 160mm with plugs including bedding in cement mortar and fixing cantilever brackets, CP waste coupling & PVC waste pipe, complete all as specified and directed. |
| 102 | S&F in replacement stainless steel plate rack of size 750mm x 600mm x 250mm, made out of 1.0mm thick stainless steel sheet with steel shelves and hanging arrangement for utensil with SS screws, complete all as specified and directed. |
| 103 | S&F in replacement 600mm x 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers, complete all as specified and directed. |
| 104 | Demolition of cement concrete (un-reinforced) as in roofs as concrete padding alongwith poly membrane if any, floors (other than ground floor), complete all as specified and directed. |
| 105 | Brushing neat cement slurry with and including 3.0 Kg of cement per Sqm, complete all as specified and directed. |
| 106 | M&L for preparing RCC roof slab top by wire brushing and cleaning the dust and foriegn material etc. complete and applying a coat of hot blown bitumen 85/25 grade @ 1.2 Kg/Sqm over coat of bitumen primer @ 0.40 Ltrs/Sqm and thereafter laying of a layer of APP based polymenic membrane (five layered with centre core as 100 microns, high molecular high density ployethlene film) minimum weighing 3.0 Kg/Sqm and reinforced with polyster non woven fabric (weight not less than 150 Gms/Sqm) laid on bituminous surface by press application method with 75mm side overlap and 100mm end overlap, the membrane has to be laid with LPG torch application and overlaps sealed and finished neat, after taght applying one coat of bitumen, 85/25 grade on top surface @ 1.20 Kg/Sqm and blinded with premier dry sand @ 0.50 Kg/Sqm dusted over bitumen coat, complete all as specified and directed. |
| 107 | M&L for preparation of surfaces and applying two coats of aluminium paint on roof, complete all as specified and directed. |
| 108 | M&L for reinforced cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) as in cover slabs (for manholes, drains etc.), chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces and set in CM 1:6 including necessary formwork, complete all as specified and directed. |
| 109 | S&F in replacement soap dish, brass, chromium plated, heavy duty, fixed to wall with plugs with brass cromium plated screws, complete all as specified and directed. |
| 110 | S&F corner glass self (with CP brakets) of size 225mm x 225mm, fixed with SS screws, complete all as specified and directed. |
| 111 | M&L for cement concrete 1:3:6 type C-0 (using 12.5mm graded crushed stone aggregates) as filling in pressed steel door frame / hold fast, back of chowkat etc, complete all as specified and directed. |
| 112 | S&F 15mm bore steel water tubing, medium grade, galvanised with all fittings and fixtures, fixed to wall or ceiling or laid in floors, complete all as specified and directed. |
| 113 | All as per serial item No. 112.00 here-in-above but 20mm bore. |
| 114 | Fixing only 15mm bore steel water tubing, medium grade, galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floors, complete with all fittings such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.), complete all as specified and directed. |
| 115 | All as per serial item No. 114.00 here-in-above but 20mm bore. |
| 116 | S&F 500 ltrs capacity rotational moulded polyethylene water storage tank, tripple layered, white colour (cylindrical vertical with closed top), hoisted and fixed in position including nipple, inlet and outlet,conneting pipes and 20mm PTMT float valve and including taking down of old UNSV existing tank with all fittings, complete all as specified and directed. |
| 117 | S&F in replacement shower rose, brass, chromium plated with CP arm of 120mm dia with or without swivel joint, with & including CP brass arm and wall flange, fixing to steel pipe or union of 15mm bore,complete all as specified and directed. |
| 118 | S&F in replacement bib tap, brass, chromium plated, fancy type, long nose with capstan head handle, screwed down high pressure including CP brass wall flanges, screwed for 15mm bore pipe connection, complete all as specified and directed. |
| 119 | S&F in replacement angle valve, brass, chromium plated, fancy type, with capstan head handle, screwed down high pressure including CP brass wall flanges, screwed for 15mm bore pipe connection, complete all as specified and directed. |
| 120 | Taking up or down 15/20mm bore steel tubing and connections including cleaning for refixing or removal to store, complete all as specified and directed. |
| 121 | Taking down carefully existing surface / concealed unserviceable aluminum/ copper point wiring (light, fan, socket, power or sunken box) complete including fittings such as switches, ceiling roses, pendants, regulators, sockets, bracket holder, boards light fittings etc. and making good to disturbed surfaces of walls, floors, ceilings etc. where required and finished the existing surfaces after complete of new point wiring, complete all as specified and directed. |
| 122 | Dismantling and taking down fluorescent tube light / panel light / bulk head light of any wattage or size fittings for repair or replacement of bumt/ worn out accessories or carrying to MES store for reuse or taking in schedule of credit, complete all as specified and directed. |
| 123 | Taking down unserviceable main switch / DBs / AC\"s box of any size and capacity including MCCB/MCB of any type & capacity for reuse, carefully disconnecting and making good to disturbed surfaces to match with existing surface, complete all as specified and directed. |
| 124 | M&L for point wiring using approved color coding as per IS code (Red, Black and Green for single phase circuit) with multi stranded copper condutor 1.5 Sqmm nominal cross section area, single core, PVC insulated and unsheathed FRLSH cable 1100V grade in and including medium grade, PVC concealed conduit ISI marked of dia not less than 20mm and conduit accessories, concealed in wall/ roof/ floor etc. with terminated to new pressed flush metal box and readily available cover with outer plates and inner plates of required module etc, suitable for mounting modular type switches, sockets, fan regulators etc. and PVC insulated multistranded copper condutor 1.5 Sqmm nominal cross section area, single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly, complete all as specified and directed for the followings :- One light Point, controlled by one, one way switch. |
| 125 | All as per serial item No. 124.00 here-in-above but for one ceiling fan point, controlled by one way switch. |
| 126 | All as per serial item No. 124.00 here-in-above but for one exhaust fan, controlled by one way switch. |
| 127 | All as per serial item No. 124.00 here-in-above but for one bell point, controlled by one way switch. |
| 128 | All as per serial item No. 124.00 here-in-above but for 3 Pin 5 Amp socket on the same board with other switches. |
| 129 | All as per serial item No. 124.00 here-in-above but 3 Pin 5 Amp Socket on independent board. |
| 130 | All as per serial item No. 124.00 here-in-above but one light point, controlled by two way switch. |
| 131 | M&L for point wiring using approved color coding as per IS code (Red, Black and Green for single phase circuit) with multi stranded copper condutor 2.5 Sqmm nominal cross section area, single core, PVC insulated and unsheathed FRLSH cable 1100V grade in and including medium grade, PVC concealed conduit ISI marked of dia not less than 25mm and conduit accessories, concealed in wall/ roof/ floor etc. with terminated to new pressed flush metal box and readily available cover with outer plates and inner plates of required module etc, suitable for mounting modular type switches, sockets of 6/16 Amps and PVC insulated multistranded copper condutor 2.5 Sqmm nominal cross section area, single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly, complete all as specified and directed. |
| 132 | S&F modular switch, single pole, one way, 6 Amps, 240 volts with polycarbonate body, complete all as specified and directed. |
| 133 | S&F modular socket, 6 Amps, 5 pin, flush type, 240 volts with polycarbonate body, complete all as specified and directed. |
| 134 | S&F modular socket outlet, 5 pin, 6 Amps and 15 amps, multipurpose 2 in 1, flush type, 230 volts with polycarbonate body, complete all as specified and directed. |
| 135 | S&F modular switch, single pole, one way, 16 Amps, 240 volts with polycarbonate body, complete all as specified and directed. |
| 136 | S&F modular switch, single pole, two way, 6 Amps, 240 volts with polycarbonate body, complete all as specified and directed. |
| 137 | S&F modular electronic fan regulator, step type, two module, 120 watt, 230 Volt and making all necessary connections, complete all as specified and directed. |
| 138 | S&F modular bell push, 6 Amps, 1 module, complete all as specified and directed. |
| 139 | S&F call bell, ding dong type, complete all as specified and directed. |
| 140 | S&F ceiling rose surface bakelite type, size 65x50mm three terminals, complete all as specified and directed. |
| 141 | S&F decorative ultra slim linear LED lighting fixture 18/20 Watt LED complete making all connection with using 1.5 sqmm copper conductor multistranded PVC insulated twin core flexible cable from ceiling rose to fitting, drawn through in PVC flexible conduit of same colour to match with fittings/wall surface, complete all as specified and directed. |
| 142 | S&F decorative ultra slim linear LED lighting fixture 10/12 Watt LED complete making all connection with using 1.5 sqmm copper conductor multistranded PVC insulated twin core flexible cable from ceiling rose to fitting, drawn through in PVC flexible conduit of same colour to match with fittings/wall surface, complete all as specified and directed. |
| 143 | S&F decorative ultra slim linear LED lighting fixture 5/6 Watt LED complete making all connection with using 1.5 sqmm copper conductor multistranded PVC insulated twin core flexible cable from ceiling rose to fitting, drawn through in PVC flexible conduit of same colour to match with fittings/wall surface, complete all as specified and directed. |
| 144 | S&F new generation energy saving 9/10 Watt LED bulk head light fitting with opal diffuser suitable for 600 LUMEN, complete all as specified and directed. |
| 145 | S&F in replacement of 35 Watt LED security light fitting with ASTRA NEO, street lights are made up of pressure die cast housing with toughened glass and high power LED with secondary optics and IP-66 protection and with 0.60 mtr long 20/25mm dia (as per manufacturer\"s standard) Gl Pipe light grade in 45 degree bend shape and necessary clamping devices as required at site, complete all as specified and directed. |
| 146 | M&L for sub main wiring with copper conductor cable four runs of multistaranded 6.0 Sqmm FRLS PVC ISI marked with all insulated unsheathed in and including PVC concealed conduit 25mm dia medium grade fittings including cutting chasing and one run of 6.0 Sqmm copper conductor cable FRLS PVC insulated unsheathed multithreaded using as continues earth wire connected to common earth and earth duly wire complete including taking down unserviceable submain of any type and size and testing on completion etc, complete all as specified and directed.Note :- Four runs of 6.0 Sqmm and one run 6.0 Sqmm cable and one run of PVC conduit shall be measured as one RM. |
| 147 | S&F in replacement MCCB DB TPN, 4 ways with metal double door CRCA sheet steel power coated, IP-43 protection suitable for MCB as outgoing, 415 Volt, 3 Phase complete with appropriate size copper bus bar and neutral link complete, cutting chases to wall for fixing of DB and making good distrubed wall surface all as required at site, complete all as specified and directed. |
| 148 | S&F MCB Metalic Distributition Board, 12 way, double door, 230 Volts concealed flush to wall for mounting MCBs, factory made, fabricated out of CRCA sheet fitted with DIN channel, neutral link and approriate rated bus bar DBs shall be semi glossy finished with epoxy polyster based powder paint sprayed and backed at high temperature, between powder paint process to ensure smooth finish and protection against corsion atmosphere. The DB shall be double door type with hinged door with locking arrangement. The DBs shall be of same make as MCBs, DB shall also be provided with lable marking indicating the incoming and outgoing circuits on all ways as specified. The DBs shall be of IP-43 protection, complete all as specified and directed. |
| 149 | S&F MCB TPN, 440 Volts, 63 Amps, breaking capacity 10 KA, \"B\" Series etc, complete all as specified and directed. |
| 150 | S&F MCB SPN, 240 Volts, 40 Amps, 50 HZ, breaking capacity 10 KA, \"B\" series, complete all as specified and directed. |
| 151 | S&F MCB SP, 240 Volts, 40 Amps, 50 HZ, breaking capacity 10 KA, \"B\" series, complete all as specified and directed. |
| 152 | S&F MCB SP, 240 Volts, 6-32 Amps, 50 HZ, breaking capacity 10 KA, \"B\" series, complete all as specified and directed. |
| 153 | S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 16 to 32 Amps 240 Volt capacity, complete all as specified and directed. |
| 154 | Taking down the existing geyser of any capacity carefully and deposit to the MES store yard of GE (North) office complex and re-fixing the same after completion of B/R works as directed by Engineer-in-Charge.Note :- Geyser will be deposited to MES store yard as directed. |
| 155 | Taking down ceiling fan / exhaust fan of any type complete and re-hanging the same when directed and connecting up with including three core copper conductor cable of 1.5 Sqmm nominal cross sectional area and length not less than 0.50 mtr from ceiling rose to fan, complete all as specified and directed.Note :- Fans shall be deposited to MES store yard as directed. |
| 156 | Supply, laying and testing of XLPE inulated, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty), 1100 Volts grade, aluminium conductor of size 50 Sqmm 3.5 Core, complete all as specified and directed. |
| 157 | M&L for earthing in repair complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to earth lead by means of bolts nuts and washers of GI steel and including earthing pit charcoal, common salt, GI 25X4mm strip as earthing lead 20mm Gl medium grade watering pipe, 40mm bore light grade protection GI pipe 5 Mtr length with wire mesh and funnel PCC pit in PCC 1:2:4 type B-1 (using 20mm graded stone aggregate), angle iron frame and RCC cover and earth work complete all as shown in electrical plate No. 3 of SSR -2009 (Part-1), complete all as specified and directed. |
| 158 | Excavation in trenches, exceeding 1.50 mtr wide and not exceeding 1.50 mtr in depth for foundation, electric pole, laying of UG cables/ pipes etc. and getting out in any type of soil, complete all as specified and directed. |
| 159 | Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick, complete all as specified and directed. |
| 160 | Removing excavated soil to a distance not exc 50 mtr form site and depositing where directed at a level not exc 1.50 mtr from the starting point, complete all as specified and directed. |
| 161 | M&L for dry river sand as in cushioning to underground cables, provided with a layer of sand 8cm thick before laying the cable and 15cm thick after laying the cable and stretching the cable, complete all as specified and directed. |
| 162 | Supply and laying sub class \"B\", old size brick, well burnt as covering or mechanical protection to UG cable, complete all as specified and directed. |
| 163 | M&L for 40mm bore GI tubing, light grade with all fittings and fixed to wall with MS clamps of suitable size or laid in floor/ trenches, complete all as specified and directed. |
| 164 | S&F in repair rigid non - metalic PVC casing caping of 25/12mm inclusive of all elbow, tees,etc complete all as per the direction of Engr-in-Charge. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail