| 1 | Dismantling of plain or corrugated steel sheeting any guage, thickness including Nanital or similar pattern roof coverings complete all as specified and as directed. |
| 2 | Taking down roof trusses, coupled rafters or trussed beams of clear span upto 4 mtrs complete all as specified and as directed. |
| 3 | Taking down cement plaster on brick or concrete wall and ceiling including raking out joint, hacking for key, scrubbing down with water etc complete all as specified and as directed. |
| 4 | Dismantling timber scantlings 40 sq. cm and over in section, in any position. |
| 5 | Taking down chowkat or frame with shutters (without taking off shutters from the frame) not exceeding 1.5sqm each and making good to disturbed surfaces and removing from site of work complete all as specified and as directed. |
| 6 | Taking down chowkat or frame with shutters (without taking off shutters from the frame) exceeding 1.5sqm but not exceeding 4.0sqm each and making good to disturbed surfaces and removing unserviceable materials from site of work complete all as specified and directed. |
| 7 | Demolition of unreinforced cement concrete in ground floors and pavings n. exc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 8 | M&L for providing reinforced cement concrete Type A-1 1:1 1/2:3 (using 20mm nominal size graded crushed stone aggregate)as in beams, cantilevers, bressumers,lintels over 1.5m span etc.complete including necessary form work all as specified and directed. |
| 9 | M&L for Pressed steel frames (105 x 60) for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed. |
| 10 | M&L for plain cement concrete (1:3:6), type C-1, (using 20mm graded crushed stone aggregates) as in bed block, blocks for holdfasts,filling in pressed steel door frames , benching slightly rounded or chamfered angles & throating etc including necessary use & waste of form work complete all as specified and directed. |
| 11 | S&F 30 mm thick, Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides & fixed to chowkats complete all as specified & directed. |
| 12 | S&F Steel windows with side hung shutters including box type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded. |
| 13 | S&F framed work such as griils, grating, angle iron door frames etc., with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, barred iron doors, laders, framed balusters, walk ways, railings frame work of water tanks and similar work conforming to Fe-290. Gde E-165 complete all as specified & as directed. |
| 14 | S&F4mm thick sheet glass, ordinary quality and glazing with oil putty in squares n exc 0.5sq. m in each panecomplete all as specified and as directed. |
| 15 | S&F 150 mm size, aluminium anodised , barrel tower bolts of extruded section & fixed completeall as specified and as directed. |
| 16 | S&F 250mm length of bolt, aluminium alloy, anodized,sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified & as directed. |
| 17 | S&F 150mm size aluminium handles, cast type, anodized and fixed complete all as specified & as directed. |
| 18 | M&L preparing new wood & wood based surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified & directed. |
| 19 | Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. including brushing neat cement slurry with 3.0 kg of cement per sq. metre. |
| 20 | M&L for machine cut kota stone slab flooring 20-25mm thick over 15 mm thick screed bedin CM !:6 laid and jointed wiyh grey cement slurry mixed with pigment to matxch the shade of the slab including rubbing and polishing complete all as specified and directed |
| 21 | M&L for kota stone slab 20-25mm thick I riser of steps, skirting, dado and pillar over 10 mm thick rendering in CM 1:4and jointed with grey cement mixed with pigment to matxch the shade of the slab including rubbing and polishing complete all as specified and directed |
| 22 | M&L for 75 mm thick Cement concrete type C-2, 1:3:6 (using 40 mm graded stone aggregates) as in plinth protection etc, finishing cement concrete surface even and smooth with out using extra cement including making joints with hot bitumastic mix in proportion of bitumen and sand 1:2 complete as specified & directed. |
| 23 | S&Frolled mild steel Plates (plain or chequred) channels, square cut or notched (ordinary and counter sunk) forming holes, with out any attachmentconforming to Fe:410-W(Gde-E-250) quality-A complete all as specified and directed. |
| 24 | S&F mild Steel work in hollow square/rectangular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S. 4923 -1997 (Reaffirmed 2009)grade Yst.-310 complete all as specified and directed. |
| 25 | S & F Mild steelbolts with hexagonal or square heads at one end and screwed the other or screwed both ends each screwedend to be fitted with washers and one hexagonal or square nut exc 30cm long and diameter exc 12 n.exc 20 complete all as specified and directed |
| 26 | S&Fpre-painted galvalume aluminium zinc coating GI based corrugated steel sheeting0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed |
| 27 | M&L for hot dip aluminium-zinc alloy metallic coated plain steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ 150, 0.50mm thick of an approved colour and having yield strength of 550MPa as in ridge/valley/gutter/eaves boardings fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed. |
| 28 | Dismantling fencing wiremesh, any type , complete all as specified and directed. |
| 29 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed surfaces embedded in concrete, complete all as specified and directed. |
| 30 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, in soft and loose soil , complete all as specified and directed. |
| 31 | S&F mild steel angle iron for posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat ironfillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 , complete all as specified and directed. |
| 32 | M & Lfor Plain Cement Concrete, Type C2 1:3:6 , (using 40 mm graded crushed stone aggregate) in foundations bed concrete, filling and mass concrete complete all as specified and directed. |
| 33 | Supply only chain link fencing MS galvanised fencing including lines wires, any mesh, size and type to standards, rails, straining bolts, etc. including provision of binding wire all as specified and directed |
| 34 | Fixing only chain linkMS galvanised fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire. |
| 35 | M&L for mild steel bars round bars 10mm dia and over, cut to length, bent to shape required and fixing as required in fencing completeall as speciified and directed. |
| 36 | M&L for mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt not exc 5 cm long diameter of the neck 5 to 10 mm complete all as specified and directed. |
| 37 | M&L for brick work with sub class old size \"B\" bricks, straight or curved on plan to any radius, built in cement mortar 1:4 as in half brick thick walls complete as specified and directed. |
| 38 | M L for brick workwith subclass “B” Old size bricks, straight or curved on plan,exceeding 6 m mean radius, built in CM 1:6 complete all as specified and directed. |
| 39 | M&L for provinding cement concrete type B-0 1:2:4(12.5mm graded crushed stone aggregate) as in coping including weathering slightly rounded or chamfered angles and throating complete all as specified and directed. |
| 40 | M&L for rendering 10mm thick plaster in cm 1:6 on fair faces of brick work or concrete surfacesincluding finishing top even and smooth without using extra cement,complete all as specified & directed. |
| 41 | M&L for preparation of new plastered surfaces of wall and preparing surfaces as directed by applying thin layer of wall care putty of 1 mm thick and finally applying two coats of distemper oil emulsion over a coat of primer complete all as specified & directed. |
| 42 | M&L for rendering 15mm thick in CM 1:4 in fair faces of brick work or concrete surfaces, finished fair and evenwithout using extra cement ,complete all as specified and directed. |
| 43 | M&L for waterproof cement based putty @ 1 Kg (undiluted) per sq mtr of average thickness 1mm over the plastered / old painted wall after complete scrapping of existing treatmentto prepare the surface even and smooth complete and sanding of the putty surface with mechanical wall sander (having mechanical vacuum mechanicsm) having RPM not less than 1500, sanding pad of 240 grit or above to make the surface free from dust etc by skilled labour as per following steps : -Step 1 : Mix the putty powder by adding water as per manufacturer instructions and mix it with putty mixer with the mixing capacity of min 2.5Kg putty per minute.Step 2 : Apply the first coat the prepared mixer with the help of fully automatic airless spray machine of putty application having flow speed of max 6 ltrs per minutes with a max pressure 3300 PSIStep 3 : Allow 6-8 hrs time to dry the putty surfaceNote : (a) The work pertaining to periodical services and water proofing shall be executed from authorized applicator through manufacturer of which the materials i.e. Paint, Distemper, Putty etc is proposed to be used by the contractor and approved by GE.(b) Cost of Scafolding upto 10 mtr height of building is included in this item.(c) The contractor shall upload along with the documents under cover I , Memorandum of understanding (MoU) with only one manufacturer mentioned in the contract, failing which the bid shall be liable to be rejected.(d) Masking of waindow/doors during spray painting using polythine film will be included (e) Cleaning and clearing site of paint, mats etc included. |
| 44 | M&L for two coat water based premium acrylic smooth exterior emulsion of approved colour with silicon additive and color stay Techonology, Excellent Dirt Pick up resistance with low VOC less than 50 gram/litre as per the LEEDS specifieecations, Anti Algal properties in two coats @ 1.79 ltr (Undiluted)/10 Sqm with water as per manufacturer instructions applied over priming coat with fully automatic airless spray machine of paint application with a flow spreed of min 1 ltr per minute having a pressure of 3300 PSI Allow 6-8 hrs to dry the surface in both coatsof paint complete all as specified and directed.Note :(a) The work pertaining to periodical services and water proofing shall be executed from authorized applicator through manufacturer of which the materials i.e. Paint, Distemper, Putty etc is proposed to be used by the contractor and approved by GE.(b) Cost of Scafolding upto 10 mtr height of building is included in this item.(c) The contractor shall upload along with the documents under cover- I , Memorandum of understanding (MoU) with only one manufacturer mentioned in the contract, failing which the bid shall be liable to be rejected. |
| 45 | S&F Galvanised. 2 strand, steel barbed wire 2.24mm diabarbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying atrossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed |
| 46 | M&L for preparation of new or previously steel surfaces of any description, over 10 cm width or girth, not otherwise described and evenly applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 47 | Taking down steel gates from its position and repair the same including thorughtining alignment properly including welding additional stiffer,pintol hinges locking arrangement etc and erecting the same back in position after applying one coat of synthetic enamel paint in area of gate n.exc 5.00 Sqm each leaf all as directed (Note : Necessary MS sections such as angle, pipe, bars, flats ,lathe /bush Pintol hinges shall be finished with necessary greasing and the same shall be be measured and paid seperately by weight ) |
| 48 | Dismantling wrought cast iron or mild steel work of any description not otherwise provided for |
| 49 | S&F Framed work of rolled mild steel conforming toFe-290 (GdeE165)as in doors or gates of angle or other section with gusset plates, rails, braces, etc, drilled for fixing of steel sheeting or other covering; doors etc to be prepared for hanging or sliding with and including either hooks & hinges or steel hanging door fittings (exclusive of steel sheeting, running rails & guides) and hanging, fastening & fixing complete ,all as specified and as directed. |
| 50 | Dismentling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing seviceable tiles to store and rubbish off the premisses complete ,all as specified and as directed. |
| 51 | M&L for chequered cement concrete tiles, cast in rubber mould, glossy finish of approved colour, general purpose, double layer, size 25 cm x 25 cm x 20 mm thick, with mixture of white and grey cement slurry in floor including laying over 15 mm thick bedding of cement mortar (1:4) complete ,all as specified and as directed. |
| 52 | M&L for 40 mm thick cement concrete type B-1, 1:2:4 (using 20 mm graded aggregate) complete ,all as specified and as directed. |
| 53 | Taking down aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete ,all as specified and as directed. |
| 54 | Material and labour for Point wiring with 1.5 Sqmm copper conductor unsheathed, multistranded, PVC insulated, single core cable FRLSHwith earth continuity conductor of 1.5 sqmm PVC insulated copper conductor and including concealed type rigid PVC conduit of suitable size but not less than 20mm dia. and allaccessories fixed to the surface of the roof/ walls etc., including terminal boxes made out of MS sheet of thickness should be not lessthan 1.2mm thickfor fixing of switches, fan regulators socket outlet etc along-with 3mm thick top laminated bakelite sheet and modular box for housing switches etc, including making good all disturbed work to match the existing complete all as specified and as directed for:-Note :- (i) Modular Plates & Covers and Modular Metal Boxes/PVC Boxes will deemed in quoted rate.(ii) Necessary PVC rigid junction boxes for identifying junction as required on site/directed by Engr-in-charge for point wiring work with PVC dummy plates shall deemed to be included in the quoted rate.(iii) The wiring shall be done strietly by following proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads. |
| 55 | (a) One light /Fan /Ex Fan point controlled by one, one way switch |
| 56 | (b) One socket outlet 3 or 5 Pin, 6 Amp on same board. |
| 57 | All as per Ser item No 54 above but with 2.5 sqmm copper cable in and concealed type rigid non-metallic PVC conduit complete all as specified and as directed for socket outlet 3 or 5 Pin, 6 Amp on independent board. |
| 58 | All as per Ser item No 54 above but with 4 sqmm copper cable in and concealed type rigid non-metallic PVC conduit complete all as specified and as directed for socket outlet 3 or 6 pin 15 Amps. |
| 59 | S&F modular switch 6 Amp one way 1 module 230 V AC complete all as specified and directed. |
| 60 | S&F modular switch 16 Amp one way 1 module230 V AC complete all as specified and directed. |
| 61 | S&F modular socket outlet 6Amp 2 module intel multi socket for all pins 230 V AC complete all as specified and directed. |
| 62 | S&F modular socket outlet 16 Amp 2 module and 6/16 Amp heavy duty 230 V AC complete all as specified and directed. |
| 63 | S&F modular ceiling fan regulator, electronic step type, 5 speed AC 230 volts, 2 module complete all as specified and directed. |
| 64 | S&F ceiling rose, three terminal, PVC/polycarbonate, isolated body, ISI markedcomplete all as specified and as directed. |
| 65 | S&F LED Tube lights fitting 1 x 18/20 Watt, 4 feet ,220V AC decorative box type with driver, holder including fitting fixed on wall/ceiling and connecting up complete with flexible cable white of suitable size and making necessary connection complete all as specified and directed. |
| 66 | Fixing only serviceable LED Tube lights fitting 1 x 18/20 Watt, 4 feet ,220V AC obtained from item no 1.00 above. |
| 67 | Taking down carefully old unserviceable ceiling fans complete, removing its blade and deposit to the MES Store yard/Keep in safe for refixing by the contactor. |
| 68 | Over hauling of ceiling fan of any sweep/ make i.e. opening of fan and cleaning ball bearing, filling grease/ oil and changing of u/s cotter pin, nut, screw, check nuts and bolts as required incl. cleaning of body, blades, down rods, canopies etc and re-assembling andpaintingcomplete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust complete all specified and directed. |
| 69 | Hanging only ceiling fan any make/ sweep and connecting up with existing electric circuit complete received from MES Store Yard all as specified and directed. |
| 70 | S&F LED Building security light fitting 1 x 35 Watt new generation energy saving and environmental friendly long life LED street light made up of pressure diecast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP65 protectionincluding mounting bracket of suitable size and connection complete all as specified and directed. |
| 71 | S&FDistribution Board factory made sheet metal enclosure double door distribution board class IP-43 IK 09 with 200 Amp rated copper bus bar 240 Volts 4 way Triple pole and neutral link, including taking down old u/s any type, complete all as specified and as directed. |
| 72 | S&F MCB triple pole and neutral (TP&N) 63 Amp 415 volts 10 KA \"C\" series with all incoming/outgoing connections with proper size lugs including taking down old unserviceable, complete all as specified and directed. |
| 73 | S&F single pole and neutral DB wall mounting type, 240 Volts,4 Way with 200 Amps rated bus bar, double door suitable for fixing MCB\"s including connecting etc and taking down U/S DB ,main switch complete. |
| 74 | S&F MCB single pole and neutral (SP&N) 32 Amp 240 volts 10 KA \"C\" series with all incoming/outgoing connections with proper size lugs including taking down old unserviceable, complete all as specified and directed. |
| 75 | S&F MCB single pole (SP) 6 to 32 Amp 240 Volts 10 KA \"C\" series with all incoming/outgoing connection with proper size lugs complete all as specified and directed. |
| 76 | M&L for providing sub main wiring with two single core 4.00 Sqmm (nominal area) PVC Insulated FRLSH unsheathed multi stranded copper conductor cable 1100 volts grade drawing through including concealed PVC Conduit of suitable sizeincluding 4.00 Sqmm PVC insulated unsheathed multi stranded FRLSH single core copper conductor cable for earth wirecomplete all as specified and directed. Note : (i) Three runs of single core 4.00 Sqmm multi stranded copper cableand one run of conduit shall be measured as one run length (ii)cutting chasing and making good to the disturbed srface shall be included in quoted rates. |
| 77 | Suplly and fix ON Load change over switch 415V in sheet metal enclosure 4 Pole of capacity 63 Amps, 50Hz Operating frequency,Electricallife min 3000 cycles,Mechanical life min 20000 cycles,Insulation Voltage 1000VManual with SS enclosure, loaded with Source seperator& Phase barrier etc complete all as specified and directed by Engineer-in-charge. |
| 78 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core, complete. |
| 79 | Excavation in trenches not exc. 1.5 meter deep and not exc 1.5 metre wide for taking up/laying of under ground cable/pole and stay foundation and getting out in soft/loose soil complete as specfied and as directed. |
| 80 | Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specfied and as directed. |
| 81 | Removing surplus soil to a distance not exc 50 meter and depositingwhere directed at a level not exc 1.5 meter above the starting point complete all as specified and as directed. |
| 82 | M&L for brick protection over cables inside the trench by using common burnt clay building bricks,sub-class\"B\" laid dry and flat and width wise along the axis of the trench complete all as specified and as directed by Engineer-in-Charge. |
| 83 | M&L for sand cushioning in cable trenches over & under the cables, with river washed coarse sand, as per standard practice with proper compaction complet all as specified anddirected by Engr-in-Charge. (Punned thickness shall be considered for payment). |
| 84 | M&L for light grade galvanized pipe ISI marked with all fitting ISI marked, laid in trenches, under road or fixing on wall/pole/ crossing nallahetc of bore40mm, complete all as specified and as directed . |
| 85 | M&L for Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to galvanized iron earth lead wire 4mm dia, (main earthing lead ) by means of galvanized bolts, nuts and washers all as shown in electrical plate no 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm dia GI pipe light grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia light grade for watering pipe with funnel & wire meshincluding necessary earth work and PCC (1:3:6) type C-1 for earth pit and 40 mm thick pre-cast RCC cover in 1:2:4 type B-1 with 3 Nos 8 mm dia TMT bars both ways, completeall as specified & directed. |