| 1 | Surface dressing n.exc 30cm deep and averaging 15 cm deep and getting out in soft/ loose soil complete all as specified and directed. |
| 2 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5m deep and getting out in soft/ loose soil complete all as specified and directed. |
| 3 | All as per item No 2 as above but depth exc 1.5m and n.exc 3.00m complete all as specified and directed. |
| 4 | M&L for provision of PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed. |
| 5 | M&L for RCC M25 Design Mix as in footing, plinth beams and columns below GL the like including necessary form work complete all as specified and directed. |
| 6 | M&L for RCC M25 Design Mix as in column above GL and the like complete all as specified and directed. |
| 7 | M&L for RCC M-25 (Design mix) as in lintel/ roof beam complete all as specified and directed. |
| 8 | M&L for damp proof course to horizontal or vertical surfaces including necessary formwork, 40mm thick, in cement concrete 1:2:4 type B0 complete all as specified and directed. |
| 9 | Form work to sides of concrete foundation, footings, base of columns, raft and raft beems, sides and soffits if any of foundation and plinth beems and similar work, verticle or to batter of rough finished surfaces of concrete flat complete all as specified and directed. |
| 10 | Form work to sides of pillars, posts, struts, piers, columns and stanchions of rough finished surfaces of concrete square, rectangular or polygonal complete all as specified and directed. |
| 11 | Formwork to sides & soffits of floor/roof beams, lintel beams and the like rough finished of cone flat surfaces complete all as specified and directed. |
| 12 | Form work to soffits of suspended slabs as roof slab similar items n.exc 200mm thick for fair finished flat surfaces complete all as specified and directed.Crompton Cat Part No : TCS-108-20-65-SL-DP-NWH. |
| 13 | M&L for high strength deformed TMT steel bars 10mm dia and over as in reinforcement cut to length, bent to shape required including cranking, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 14 | M&L for high strength deformed TMT steel bars, as in reinforcement, 6mm to 8mm dia, cut to length, bent to shape required including cranking, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 15 | All as per item No 13 but 5mm to 10mm in stirrups, spacers and binders complete all as specified and directed. |
| 16 | M&L for Spreadig, levelling in layers n exc 25 mm thick and well ramming in floorsincluding watering in soft/ loose soil complete all as specified and directed. |
| 17 | M&L for brick work with sub class \"B\" bricks built in cement mortar 1:6 straight orcurved on plan & exc 6 m mean radius with old size bricks complete all as specified and directed. |
| 18 | Returning filling in cluding spreading levelling watering and well ramming in layers n.exc 25 cm in soft loose soil complete all as specified and directed. |
| 19 | Removal of surplus soil n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed. |
| 20 | M&L for broken stone as hard core of gauge n,exc 63mm, deposited, spread and leveled in layers n.exc 150mm thick, watered and rammed to a true surface complete all as specified and directed. |
| 21 | M&L for PCC 1:4:8 type D2, 75mm thick (using 40mm graded stone aggregate) as in sub base in flooring work complete all as specified and directed. |
| 22 | M&L for vitrified ceramic (square/ rectangular) light coloured polished tiles of thickness 10mm, (1st quality) area of each tiles n.exc 0.36 sqm and in floors etc, set and jointed in neat cement slurry and pointed in whitecement and pigmentto match over 15 mm thick screeding in cement mortar 1:6 complete all as specified and directed.Note: screed bed shall also deemed to be included in the quoted rate by the contractor. |
| 23 | All as per item No 22 above, but in skirting/dado over 10mm coment mortar 1:4 complete all as specified and directed. |
| 24 | M&L for rendering 15mm thick in cement mortar 1:6 on brick/ concrete surface finished even and smooth without using extra cement internal wall surface complete all as specified and directed. |
| 25 | M&L for rendering 20mm thick intwo layers (12+8) in cement mortar 1:4 on brick/ concrete surfaceas in external wall surface etc, finished and even and smooth without using extra cement complete all as specified and directed. |
| 26 | M&L for rendering 5mm thick in cement mortar 1:3 on concrete as in ceiling surface etc finished fair and even without using extra cement complete all as specified and directed. |
| 27 | M&L for PCC 1:2:4 type B0 (using 12.5mm graded stone aggregate) as in coping and similar works including necessary form work complete all as specified and directed. |
| 28 | M&L for PCC 1:2:4 type B1 (20mm graded stone aggregate) as in floors 40mm thick finished rough to receive floor finishes complete all as specified and directed. |
| 29 | M&L forpreparation of newly plastered surfaces of walls andapplying two coats of exterior emulsion paint 100% acrylic, any tinted as in (camouflage pattern),over acoat of cement based primerincluding washing floors, cleaning glass, joinery, electrical fittings, wiring etc, or drops andsplashes complete all as specified and directed. |
| 30 | M&L for Preparing newly plastered surfaces of walls and applying 2mm thick wall care putty on plastered surfaces and distempering with oil emulsion distemper two coats complete all as specified and directed. |
| 31 | M&L for Preparing newly plastered surfaces and applying white wash of three coats on ceiling complete all as specified and directed. |
| 32 | S&F for Galvanized mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperature 1.18 mm fixed with tinned tacks or galvanised wire staples complete all as specified and directed. |
| 33 | M&L for preparation of new steel surfaces of any description, over 10cm in width or girth,not otherwise described and applying two coat of synthetic enamel paint over a coat of red oxide complete all as specified and directed. |
| 34 | S&F for anodised aluminium grill (anodised transparent or dyed to required shade according to IS:1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with CP brass/ stainless steel screws @ 200mm centre to centre, including cutting the grill to proper opening sixe for fixing and operation of handles and fixing approved anodised aluminium sstandard section around the opening complete all as specified and directed. (only weight of grill to be measured for payment |
| 35 | S&F for 35 mm thick Flush door shutter, solid core construction with block board coreand plywoodface panels commercial type on both side complete all as specified and directed. |
| 36 | M&L for Preparation of new wood surfaces of any description over 10cm width or girth and priming with pink primer and painting with synthetic enamel painting two coats complete all as specified and directed. |
| 37 | S&F for 300 mm long Aluminium alloy anodised sliding door bolts with hasp and staple(bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium and fixed complete all as specified and directed. |
| 38 | S&F for 100mm size, mild steel butt hinge medium weight cold rolled & fixed complete all as specified and directed. |
| 39 | S&F for 150mm length aluminum, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed. |
| 40 | S&F for 150mm size aluminum handles, cast type anodised complete all as specified and directed. |
| 41 | Supply only Liguid water proofing compound complete all as specified and directed. |
| 42 | S&F for tubular roof trusses (framed) trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pleces, cleats etc complete all as specified and directed. |
| 43 | S&F for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 44 | S&F for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 45 | S&F for powder coated aluminium window and ventilator shutters, sliding type without sash bars, aluminium sections weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings complete all as specified and directed. |
| 46 | S&F for powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed. |
| 47 | S&F for 5mm thick sheet glass, ordinary quality and glazing with oil putty in square exc 0.5 sqm in each pane complete all as specified and directed. |
| 48 | S&F for 20mm dia curtain rod mild steel, chromum plated with fixing brackets, stops, rollers etc complete all as specified and directed. |
| 49 | S&F for aluminium anojdised snap grid grame work as in false ceiling all as specified size of grid 605 x605mm with aluminium main \"T\" section of size 36.5 x23.5 x 1.60mm including 6mm dia GI hangers complete all as specified and directed. |
| 50 | S&F for non-asbestos fibre cement building board, 4mm thick, fixed to aluminium frame work with screw as in ceiling in flat or sloping complete all as specified and directed. |
| 51 | M&L for MS Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and directed. |
| 52 | M&L for Mild steel bolts, purpose made, with hexagonal or square head one end and screwed the other, or screwed both ends each screwed end to be fitted with washers and one hexagonal or square nut exc 30cm long complete all as specified and directed. |
| 53 | M&L for Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long dia bolt 16 to 20mm complete all as specified and directed. |
| 54 | M&L for MS wind ties for roof including securing bolts; including all necessary drilling bolting etc conferming to Fe-290 Gde E-165 complete all as specified and directed. |
| 55 | M&L for preparation of new steel surfaces of any description, nexc 10cm in width or girth,not otherwise described and applying two coat of synthetic enamel paint over a coat of red oxide complete all as specified and directed. |
| 56 | M&L for Antitermite treatment to back fill in contact with masonry @ 7.5 ltrs/Sqm complete all as specified and directed. |
| 57 | Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and directed. |
| 58 | M&L for treating the top surface of filled earth with anti termite emulsion at the rate of 5 litres per square metre of surface area complete all as specified and directed. |
| 59 | M&L for treating the top surface of filled earth under plinth protection with anti termite emulsion at the rate of 5 litres per square metre of surface area complete all as specified and directed. |
| 60 | M&L for point wiring with 1.5 sqmm cable PVC unsheathed and insulated copper multistranded conductor(FRLS) 1100 Volts grade cable (red colour cable to be used for Phase connection and black colour cable to be used for neutral connection)including PVCconduit with all accessories including 1.5 sqmm copper multistrand conductor FRLS 1100 Volts grade unsheathed PVC insulated (green colour) continuity earth wire connected to common earth dolly and sunk cast pressed steel terminal box made out of MS sheet 1.2 mm thick for mounting of fittings like switch, socket and fan regulator with 3 mm thick hylum laminated sheet cover complete all as specified and as directed. |
| 61 | Light/ Fan/Exhaust fan/ Bell point |
| 62 | 5 amp socket on same boared |
| 63 | 5 Amp switch socket on Independent Board. |
| 64 | All as per item No 60 here in before but 4.0Sqmm P.V.C insulated un sheathed cable with stranded copper conductor for 5 pin 6/16 Amp switch socket combination on independent board complete all as specified and directed. |
| 65 | S&F for socket only 3 pin, 5 Amps flush type 230/240 V complete all as specified and directed. |
| 66 | S&F for switch socket combination 2 in 1, 5/6 Amps flush type230/240 V complete all as specified and directed. |
| 67 | S&F for switch socket combination 3 pin, 15/16 Amps flush type 230/240 V complete all as specified and directed. |
| 68 | S&F for ceiling rose 3 phase/PVC/polycarbonate, isolated body, surface type with ISI marked complete all as specified and directed. |
| 69 | S&F for switch piano flush type 5/6 amps, 240 volt single pole one way complete all as specified and directed. |
| 70 | S&F for Step type electronic fan regulator flush type230 volt 5 speed control and connecting up and fix position complete all as specified and directed. |
| 71 | S&F for ceiling fans complete with blades, down rods, and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed. |
| 72 | S&F for exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete all as specified and directed. |
| 73 | S&F for wall decorative ultra slim LED 18/20 Watt, 230 volts, 50 Hz, 4 feet, lighting fixture with extruded polycarbonate lighting fixture, environmental friendly, energy efficient ready to use pack including lamp ccomplete all as specified and directed.Crompton Cat Part No : TCS-108-20-65-SL-DP-NWH. |
| 74 | S&F for recessed mounted 36 Watt (clear white) LED panel light2x2 feet, ultra slim design, 230 volts, 50 Hz with CRCA sheet housing precoated white colour and high quality diffuser for uniform light and high efficiency with separate replaceable electronic driver including lamp complete all as specified. Crompton Cat Part No : TCR-145-36-65-SL-NWH. |
| 75 | S&F for building security light LED type of minimum 3000/3500 Lumens (30/35watts) pressure die cast aluminium housing IP 66 protection with all accessories internally prewired and including connecting up with twisted copper conductor cable of suitable size including bracket made of 32mm dia GI light grade pipe of 1.2m long bent to shape fixed with suitable MS clamps, bolts, nuts and washers duly painted complete all as specified and directed. Crompton Cat Part No : ERP-427-35-57-HL2-LM-NBK. |
| 76 | M&L for sub main wiring withtwo run of 6.0 Sqmm PVC unsheathed, copper conductor cable, 1100 Volt,and onerun of copper earth wire 6.0 Sqmm drawn through PVC concealed conduict of 25 mm dia, complete all as specified. Note: Copper conductor 2 run and one run of copper earth wire along with PVC concealed conduictshall be measured as one length & Cutting of chases/ walls and making good the disturbed surface are included in the ratecomplete all as specified and directed. |
| 77 | S&F for factory made sheet metal enclosure for DBs double door, SPN, 230 volt,12 Way, IP-42 protection with bus bar, neutral link, earth link complete all as specified and directed. |
| 78 | S&F for factory made sheet metal enclosure for DBs double door, SPN, 230 volt,4 Way, IP-42 protection with bus bar, neutral link, earth link complete all as specified and directed. |
| 79 | S&F for 240V, 10KA \"C\" curve miniature circuit breaker (MCB) SP 10 to 32 Amp current carrying capacity complete with connection testing complete all as specified and directed. |
| 80 | S&F for 240V, 10KA \"C\" curve miniature circuit breaker (MCB) SPN 63 Amp current carrying capacity complete with connection testing complete all as specified and directed. |
| 81 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 2 core complete all as specified and directed. |
| 82 | S&F for GI Pipe of 25 mm dia light grade for cable protection pipe complete all as specified and directed. |
| 83 | M&L for sand cushioning to under ground cable provided with a layer of sand 8 cm depth before laying of cable and 15 cm depth after laying and stretching the cable complete all as specified and directed. Note: Punned thickness of sand shall be measured & paid. |
| 84 | M&L for well burnt sub class \"B\" bricks of nominal size 230X115X75 mm abutting each other for mechanical protection of cable with width equal to lenght of brick including taking out old complete all as specified and directed. |
| 85 | M&L for earthing complete with GI plate electrode 600x600x6.3mm thick, buried directly and preferably vertically in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected with Galvanize earth wire 4 mm dia by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No 3, connected to earthing with DBs all as specified including earth work and excavation in any type of soil, PCC 1:3:6 type C1 chamber & RCC 1:2:4 type B1 cover 40mm thick, with 8mm dia steel deformed (TMT bars) reinforcement at 150mm c/c both ways,20mm dia GI medium grade pipe for watering , water funnel complete all as specified and testing on completion. |
| 86 | Material and labour laying well burnt old sizebricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection all as specified. |