| 1 | Dismantling Stone slabs & tiles of any description or thickness in floors, aprons etc., laid bedded & pointed in any mortar complete all as specified and directed. |
| 2 | Demolition of cement concrete (unreinforced) of any description & in any position not otherwise specifically provided for complete all as specified and directed. |
| 3 | M&L for Machine cut Kota stone slab flooring 20-25 mm thick laid over & including 20 mm thick screed bed or bedding layer of 1:6 cement mortar, laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & polishing complete all as specified and directed. |
| 4 | M&L for Machine cut Kota stone slab 20-25 mm thick in riser of steps, skirting, dado & pillar over & including rendering 15 mm thick in 1:4 cement mortar, laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & polishing complete all as specified and directed. |
| 5 | M & L for Mirror polishing on marble/ granite/ Kota stone/ stone work where ever required to give high gloss finish complete all as specified and directed |
| 6 | M&L for Rounding to edges of stone slabs one edge, such as in steps, cooking platform & other similar situations complete all as specified and directed. |
| 7 | M&L for 75 mm thick Cement Concrete Type C2, 1:3:6 (using 40 mm graded stone aggregate) as in plinth protection etc. & finishing cement concrete surface even and smooth without using extra cement complete all as specified and directed. |
| 8 | M&L for providing Glass dividing strips, 3 mm thick and 38 mm width of strip in plinth protection for making panels complete all as specified and directed. |
| 9 | Demolition of brick work or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc., but excluding ashlar facings, dressed stonework & precast concrete articles complete all as specified and directed. |
| 10 | M & L forbrickwork with subclass `B\" bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified and directed |
| 11 | M&L brick work with sub class B bricks straight or curved on plan exc 6m mean radius in half brick built in CM (1:6) complete all as specified and directed. |
| 12 | M&L for cement concrete Type D-2, 1:4:8 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed. |
| 13 | Taking down cement or cement lime plaster, any description on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed. |
| 14 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces of Wallin CM 1:6 and to be finished even and smooth (without using extra cement) complete all as specified and directed. |
| 15 | M&L for rendering 5 mm thick in cement mortar 1:3 on RCC ceiling surface and finished even and smooth (without using extra cement) complete all as specified and directed. |
| 16 | M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces of wallin CM 1:4and to be finished even and smooth (without using extra cement) complete all as specified and directed. |
| 17 | M&L for preparation of newly plastered or unplastered brick work or concrete surfaces & applying two coat of cement based paint over & including one coat of alkali resistant priming paint on prepared brick work or concrete surfaces complete all as specified and directed. |
| 18 | M&L for preparation of newly plastered or unplastered brick work or concrete surfaces & applying two coats of oil bound distemper over & including one coat of alkali resistant priming paint on prepared brick work or concrete surfaces complete all as specified and directed. |
| 19 | M&L for preparation of newly plastered or unplastered surfaces of ceiling and apply three coat of white wash on prepared ceiling surface complete all as specified and directed. |
| 20 | M&L for complete removal of existing treatment on brick work or concrete surfaces & applying 2 mm thick Wall Care Putty on brick work or concrete surfaces complete all as specified and directed. |
| 21 | M&L for preparation of newly plastered or unplastered brick work or concrete surfaces & applying 2 mm thick Wall Care Putty on newly plastered or unplastered brick work or concrete surfaces. Complete all as specified and directed . |
| 22 | M&L for preparation of old painted brick work or concrete surfaces & applying two coat of cement based paint on brick work or concrete surfaces. Complete all as specified and directed. |
| 23 | M&L for preparation of old painted brick work or concrete surfaces & applying two coat of oil bound distemper on brick work or concrete surfaces complete all as specified and directed. |
| 24 | M&L for preparation of old painted ceiling surfaces & applying twocoat of white wash on ceiling surfaces complete all as specified and directed. |
| 25 | M&L for preparation of old painted Steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying one coat of Synthetic enamel paint (ordinary tint) complete all as specified and directed. |
| 26 | M&L for applying two coats of synthetic enamel paint on steel & iron surfaces of any description, not otherwise described over 10cm width or girth including preparation of new surface and applying one coat of red oxide, zinc chrome complete all as specified and directed. |
| 27 | S&F 110 mm bore, PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls complete all as specified and directed. |
| 28 | S&F 110 mm bore PVC (SWR) bends any radius complete all as specified and directed. |
| 29 | S&F 110 mm bore PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed. |
| 30 | S&F Stack clamps out of 50 mm by 5 mm flat iron and 16 mm dia round iron stays, Including bolts and nuts and securing ends of stays to wall or roof for 100 mm bore of pipe. Complete all as specified and directed. |
| 31 | M&L for providing Cement Concrete Type B-1, 1:2:4 using 20 mm graded stone aggregate as in lintels upto 1.5 m clear span, cills, steps; seismic & other similar bands, plinth courses, string courses, lacing courses, parapets & railings upto 60 cm in height, copings, roof padding, sunken slab, benching, kneelers, apex stones, bed plates, kerbs, water troughs & the like including weathering, slightly rounded or chamfered angles and throating including necessary form work. Complete all as specified and directed. |
| 32 | Taking down Chowkhats or frames not exc. 1.50 sqm each with shutters (without taking off shutters from the frame) and removing to store. Complete all as specified and directed. |
| 33 | Taking down Chowkhats or frames exc. 1.50 sqm but not exc. 4 sqm each with shutters (without taking off shutters from the frame) and removing to store. Complete all as specified and directed. |
| 34 | S&F MS hand rails, half round or othersection forwind ties for roof including securing bolts; , drilling holes, notching complete all as specified and directed. |
| 35 | S&F of Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe-290 Gde-E-165. Complete all as specified and directed. |
| 36 | Providing and fixing of double rebate openable/fixed windows (Eco 4000) with both glass shutter and wire mesh Shutter made of galvanized steel colour coated/powder coated (base steel as per IS 513 of \"D\" quality, galvanized as per lS 277 with zinc of 120 grams/sqm) with total thickness of coating 0.58 mm, primer coated with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with alkyd backer 5-7 microns thick or powder coated with pure polyester powder up to 50- 60 microns thick, outer frame section 72 x 55 mm, centre mullion section 72 x 50 mm, shutter section 47 x 20 mm,fly mesh section 40 X 20 mm and the fixed glass beading section 12x 12 mm, outer frame and mull ions shall consists rebate for glazed shutter, fly mesh and 20 mm provision for guard bars/grills, the sections cut to length mitred joined with corner bracket, centre mullions fixed with mullion cap, stay, handles, latch, 2 Nos of heavy duty stainless steel pivot hinges per shutter and panelled with 4 mm thick plain clear glass and S.S. Mesh for fly mesh shutter (304 grade), fitted using EPDM (Ethyl Propylene Diamine Monomer) gaskets including fixing windows in the concrete/masonry wall by means of self-expanding screws, including 10mm Square bars welded to 6x12 mm flat at a distance 150m m c/c (pitch) etc.all as per HQ CE JZ DRG No : CEJZ/TD/980 of Sheet 1/2 & 2/2 complete all as specified and directed |
| 37 | Provinding and fixing of Ventilators, fixed louvers fabricated from Rolled framed sections made of galvanized Steel colour coated/powder coated (base Steel as per IS 513 \"D\" quality, galvanized as per IS 277 with zinc of 120 grams/Sqm) with thickness of 0.58mm coated sections to be primer coat of epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with alkyd backer of 5-7 microns or powder coated with pure polyester powder up to 50-60 microns thick, section for external frame 33x 58 mm, glass holding flanges made of polypropylene, sections are to be cut to length, mitred joined with corner bracket. The above frames should be fixed to the concrete/masonry walls including 10mm Square bars welded to 6x12 mm flat at a distance 150mm c/c (pitch) etc by means of self expanding Screw all as per HQ CE JZ DRG No : CEJZ/TD/980 of Sheet 1/2 & 2/2 complete all as specified and directed |
| 38 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat of size125x65 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate & natural fibers (wood powder/rice husk/wheat husk) & non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement & screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/sqmm, modules of elasticity 900 N/sqmm & resistance to spread of flame of class A category with property of being termite/borer proof, water/moisture proof & fire retardant & fixed in position with MS hold fast/lugs/SS dash fasteners of required dia & length complete as per direction of Engineer-in-Charge. (M.S. hold fast/lugs or SS dash fasteners shall be paid for separately). Note : For WPC solid door/window frames, minus 5 mm tolerance in dimension i.e., depth & width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 39 | Providing & Fixing Factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 35 mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate & natural fibers (wood powder/rice husk/wheat husk) & non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum & screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/sqmm, modulus of elasticity 850 N/sqmm & resistance to spread of flame of class A category with property of being termite/borer proof, water/moisture proof & fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter & fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-in-Charge. Note : Stainless Steel butt hinges & necessary S.S screws shall be paid separately. |
| 40 | Providing & Fixing Factory made single extruded WPC (Wood Polymer Composite) skelton door shutter of size 35 mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate & natural fibers (wood powder/rice husk/wheat husk) & non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum & screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/sqmm, modulus of elasticity 850 N/sqmm & resistance to spread of flame of class A category with property of being termite/borer proof, water/moisture proof & fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter & fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-in-Charge. Note : Stainless Steel butt hinges & necessary S.S screws shall be paid separately. |
| 41 | S&F 100 mm long extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed. |
| 42 | S&F 150 mm long aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed. |
| 43 | S&F 100 mm Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21 complete all as specified and directed. |
| 44 | S&F 100 mm stainless steel Butt hinges with stainless steel screws complete all as specified and directed. |
| 45 | S&F 250 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy & fixed complete all as specified and directed. |
| 46 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 47 | Dismantling timber scantling 40 Sqcm and over in section in any position (framed works) complete all as specified and directed. |
| 48 | S&F roof trusses (framed), trussed, purlins, crane gantries, rails and fastening and heavy bracket framing (beam, tee, angle channel or flat sections) including distance pieces, cleats etc complete all as specified and directed. |
| 49 | Dismantling of Single layer Manglore pattern Roof tiles in roofing complete all as specified and directed |
| 50 | Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets. Complete all as specified and directed. |
| 51 | S&F powder coated aluminium snap grid frame work for false ceiling with aluminium angle 25 mm x 25 mm x 1.5 mmfixed to perimeter of wall, main \"T\" runner 38 mm x 25 mm x 1.5 mm and secondary/cross \"T\" runner 25 mm x 25 mm x 1.5 mm to be interlocked in such a way that the size of grid shall be 605 mm x 605 mm including 6 mm dia GI hangers (upto 1200 mm length) adjusting level fixed to roof by means of ceiling cleats made out of GI flat 40 x 3 mm, 60 mm long and expansion hold fasteners 12.5 mm dia , 40 mm long and 4 mm thick Non asbestos fibre board (E-board or V board) designer tiles (Electra) suitably fixed in false ceiling grid/frame with staples or screws complete all as specified anddirected. |
| 52 | Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering complete all as specified anddirected. |
| 53 | M&L for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.( Height of Bldg upto 12.50mtr) |
| 54 | M&L for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 55 | M&L Water proofing treatment on roofsurface (Horizontal & Vertical surfaces) in following sequence through manufacturer / authorized applicator of the manufacturer including taking down of existing roof treatment,properly cleaning & drying the concrete surfaces complete all as specified and directed. |
| 56 | M&L10 mm thick rendering on roof surfaces/concrete surface in CM 1:4 complete all as specified and directed. |
| 57 | M&L for applying a coat of oxidised bitumen based solvent primer @ 0.3 Kg / Sqm complete all as specified and directed. |
| 58 | M&L for applying evenly a tack coat of industrial bitumen 85/25 grade @ 1.2 kg/ Sqm incl cleaning surfaces complete all as specified and directed. |
| 59 | M&L for laying 3 mm thick unrolled over the bitumen coated surface, polymeric water proofing membrane Hyperplas standard wt not less than 3kg /Sqm with 100 mm over laps shall be sealed by flame as per manufacturer\"s instruction complete all as specified and directed. |
| 60 | M&L for applying two coats of bituminous base aluminium paintincluding preparation complete all as specified and directed. |
| 61 | Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, holders, pendants, regulators, sockets etc and making good disturbed surface by using cement mortar, white cement, putty etc and match with existing surfaces of walls, floors etc complete all as specified as directed. |
| 62 | Taking down carefully any type of old unserviceable submain wiring with PVC/steel conduit surface / concealed or wooden battensetc and making good the disturbed surfaces to match with the existing surface complete all as specified & directed by Engineer-in-Charge. |
| 63 | Taking down carefully any type of DBs including MCCBs and MCBs for keeping the old materials into safe custody or for taking credit(credit for above items should be made as per condition seaparately) and making good to the disturbed surface etc complete all as specified and directed. |
| 64 | M&L for point wiring for One light point controlled by one switch 5/6 Amps complete with 1.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LS cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit not less that 20mm dia and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LS (ISI marked) as earth continuity conductor connected to common earth dolly, including cutting chases of existing wall for conduits and sinking for boxes and making good to the disturbed surface of wall/floor and matching with existing specifications.Connections of cable with MCBs or bus bar shall be sone through proper size copper/brass thimbles. Where concealing of conduit is not feasible ie on surface of roof etc, conduit shall be fixed on surface with necessary saddles at no extra cost all as specified and as directed |
| 65 | All as per item No 59 here-in-before but for one Ceiling fan/Exhaust fan Point controlled by one switch 5/6 Amps. |
| 66 | All as per item No 59 here-in-before but for one socket point 5/6 Amp controlled by one switch on same board. |
| 67 | All as per item No 59 here-in-beforebut for onesocket point 5/6 Amp controlled by one switch on Independent board. |
| 68 | All as per item No 59 here-in-before here in above but with 1100 Volts grade copper stranded conductor FRLS cable of size 2.5 Sqmm main & with 2.5 Sqmm earth multi-strand copper conductor cable as earth wire for 3 pin switch socket outlet 5/15 Amp on Independent board |
| 69 | All as per item No 59 here-in-before but with 1100 Volts grade copper stranded conductor FRLS cable of size 4 Sqmm main & with 4 Sqmm earth multi-strand copper conductor cable as earth wire for 3 pin switch socket outlet 5/15 Amp on Independent board |
| 70 | Materialand labour for concealed sub-main wiring alongwith earth wire of size of 2 x 6.0 sq. mm + 1 x 6.0 sq. mm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn in through and including PVC rigid conduit (medium grade) of size not less than 25 mm with all fittings and accessories, ISI marked, including cutting chases for conduits &making good to walls, floors etc complete, all as specified and as directed. NOTE: Two runs of 6 sqmm conductor for main and one run of 6 sqmm conductor as earth wire with proper colour coding including one run of PVC conduit shall be measured as one unit length. Connections of cables with MCBs or bus bar shall be done through appropriate size brass/ copper thimbles |
| 71 | S &F Lamp holder, PVC/ polycarbonate type with back plate for angle holder all as per specified and directed. |
| 72 | S&F Ceiling rose surface type 60 x 30 mm three terminals of polycarbonate body complete all as specified & directed. |
| 73 | S&F modular switch6 Amps one module230 volts AC complete all as specified and as directed. |
| 74 | S&F modular switch16 Amps one module230 volts AC complete all as specified and as directed |
| 75 | S&F modular socket, 6A -2/3 pin combined 2 module,230 volts AC complete all as specified and as directed. |
| 76 | S&F modular socket, 6/16A -2/3 pin combined 2 module,230 volts AC complete all as specified and as directed . |
| 77 | S&F modular fan regulator, 2 Module 4 step upto 180 W heavy duty 230 volts complete all as specified and as directed. |
| 78 | S&F modular cover plate 2 module includingscrews and washers etc complete all as specified and as directed. |
| 79 | S&F modular cover plate 3 module includingscrews and washers etc complete all as specified and as directed. |
| 80 | S&F modular cover plate 8 module includingscrews and washers etc complete all as specified and as directed. |
| 81 | S&F modular cover plate 12 module includingscrews and washers etc complete all as specified and as directed. |
| 82 | S & F Metal flush box 2 module complete all as specified and directed. |
| 83 | All as per item No 77 here-in-beforebut 3 module |
| 84 | All as per item No 77 here-in-before but 8module |
| 85 | All as per item No 59 here-in-before but 12module |
| 86 | S & Fsheet metal enclosure MCCB DB VTPN 4 Way vertical type 250 A Copper Busbar for each phase Fully insulated busbar & shrouded Neutral bars with provision for DPX³ 160 MCCBas incomer and SP/TP MCB\"s as outgoing Reversible Door for IP 43 IK-09 DB\"s system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and directed. |
| 87 | Supply and Fixing Sheet metal enclosure for DBs when MCBs to be Used, 8 way, SP & N, double door type, 240 Volt, including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and directed. (Note : MCBs will be Measured separately). |
| 88 | Supply and Fixing Sheet metal enclosure for DBs when MCBs to be Used, 4 way, SP & N, double door type, 240 Volt, including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and directed. (Note : MCBs will be Measured separately) |
| 89 | Supply and Fixing MCCB, four pole, 100 Amp, 415 Volt, of breaking capacity 16 KA complete all as directed. |
| 90 | Supply and fixing 240V 10KA \"C\" curve miniature circuit breaker (MCB), SPN, 40 Amps current carrying capacity in the DB complete with connection, testing and commissioning, all as specified and directed. |
| 91 | Supply and fixing 240V 10KA \"C\" curve miniature circuit breaker (MCB), SP, 6-32 Amps current carrying capacity in the DB complete with connection, testing and commissioning, all as specified and directed. |
| 92 | S & F forLED luminaire coolday/warm white as required 600 mm x 600 mm square LED panel 35/36 watts, 220V recessed type with high efficieny PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling, including connecting up with driver three core flexible copperr conductor cases of suitable sizecomplete all as specefied and directed. |
| 93 | Supply & Fixing Smart bright Batten Series, LED luminaire using LEDs 20 watt min 100 LM/watt, natural white(4000K)/ cool white (6500k), with diffuser which ensures uniform distribution and comfort batten series features latest LEDs and delivers consistent light outputwith wide voltage protection range, stable color start Extruded Aluminum housing, Energy efficient, Flicker free start Inbuilt driver unit Suitable for wall and ceiling mounting using brackets (supplied along with The Luminaire has been tested as per Standard Specification IEC 60598-2-1 / IS: 10322(Parts/Secl), report has established conformity of the product(s) to the requirements of the Standard/Specification. |
| 94 | Supply and fix in repairs LED bulk head luminaires,9 watts (600-900 lumens) lamp with fittings, connecting cable PVC insulated and PVC sheathed copper flexible cable of size 16/ 0.20 mm with necessary fixing arrangments complete all as directed. |
| 95 | S & F LED Mirror light fitting 2 ft tubelight, 10 watt aluminum housing and integrated electronic driver complete with fixing arrangements on wallall as specified and directed. |
| 96 | Supply & fix in replacement ofLED Security Light Luminaire 35 wattwith 2500 or more lumen warm white/cool day ligh with, surge protection device upto 4KV, IP65 or more, IK07 or more, potted driver suitable for 180 to 270 V, 50 Hz, light engine driver base.pole adapter, powder coated pressure die cast aluminium with heat resistant toughened glass with lens type,GI pipe 40 mm dia medium Grade not less than with 1.2 m.long in any shape with 2 nos ofpole/wall fitting clamps made out of MS flat , nutsand boltsand painting with aluminium paint. complete all as specified and as directed. |
| 97 | S&F in repairsLED Bulb230V AC12 watt warm/cool day light 6500K as per the direction/requirement of sitecomplere all as specified and directed by Engineer-in -charge. |
| 98 | Taking down ceiling fan/exhaust fan sealing cable end, dismantling blades and removing fan and blades to store complete all as specified by Engr-in-charge |
| 99 | Hanging only ceiling fan/exhaust fan and connecting up including provision of flexible cable from ceiling rose or connector to fan Including hook and clamps with nut ,bolts, washers etc complete all as specified and directed |
| 100 | M & L for painting of ceillingfan/exhaust fan of any make/model and size complete with one coat of 1st grade quality of synthetic whiteenamelled paint by spraying including preparation of old paianted surface to remove all dust, oil mark etc and filling cavaties with filler materials, before painting, complete writing the MES numbers on ceiling fan with black synthetic enamel paint of 1st grade quality by stenciling with uniform size of letters/of figures n.exc 20 mm in height letters/figures to be written in each fan complete all asspedified and directed. |
| 101 | M & L for 4mm dia galvanised iron or steel wire Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required complete all as specified and directed. |
| 102 | M &L for Earthing complete with GI earth plate electrode 600x600x6mm thick buried directly in ground (Earth pit not less than 2.25M deep below normal ground level) with top edge of the plate not less than 1.5m below normal GL. Connected to galvanized earth lead wire 4mm dia by means of nut, bolt, check nut and washersincluding necessary excavation and earth work in soft/loose soil, GI protection pipe light grade 15mm bore for protecting the GI wire mesh funnel alternate layer of charcoal dust, and saltPCC pit 1:3:6 type C1 using 20mm graded stone aggregate and 50mm thick RCC 1:2:4 type B1 using 20mm graded stone aggregate with angle iron CI frame 40X40X5mm , CI cover with provision of locking arrangementcomplete all as specified and shown in Electrical plate No.3 SSR part-1 and connected to the earth point and testing complete including taking out the old one complete all as specified and directed by Engr-in-Charge. including necessary excavation and earthwork in any type of strata and testing complete including fill up the earth pit with soil for best result and removal. Note :-(i) Earth protection pipe & earthing wire upto and including 7.5 m length is deemed included in unit rate quoted by the contractor (ii) If earth resistance of earthing is not found satisfactory it will be redone by the contractor without any extra cost to Govt.. |
| 103 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundation of poles/stays/cables etc and getting out in any type of soil,complete all as specified and as directed. |
| 104 | Returning, filling in, including, spreading, levelling, watering and well ramming in layers n.exc 25cm complete all as specified and as directed. |
| 105 | Removing excavated material n.exc 50m and depositing were directed at a level n.exc. 1.5m above the starting level complete all as specified and as directed.. |
| 106 | M&L for sand cushioning in cable trenches over & under the cable, with river washed coarse sand, as per standard practice with proper compaction complete all as specified and directed by Engr-in-Charge. (Punned thickness 18 cm shall be considered for payment as per para 19.75 of SSR Part-I) |
| 107 | M & L for Fly Ash bricks Sub-class \"B\" locally available laid flat in trenches over sand cushioning for cable protection complete all as speciffied and directed. |
| 108 | Supply and fixing 40 mm dia GI tubing medium grade ISI marked fixing to pole with suitable clamps / laid under floor/road for protection of cable complete all as specified and directed. |
| 109 | Disconnecting & taking out defective under ground LT cable from trenches, pole, pipe,floor ,wall etc including bricks ,GI pipes and removing from work site of unserviceable material of any size complete all as specified and directed.Note: Excavation/earth work shall be measured & paid separately under relevant item of this schedule |
| 110 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm2 core all fixing and connecting accessories such as cable lugs, cable glands, nut, bolts, complete all as specified and as directed. |
| 111 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm3.5 core all fixing and connecting accessories such as cable lugs, cable glands, nut, bolts, complete all as specified and as directed. |
| 112 | Material and labour for horizontal boring across the existing road/path way/hard standing without disturbing the surface for inserting 40 mm bore GI pipe, complete all as specified and as directed. |
| 113 | Schedule of credit amount of Rs 168086.40 to be deducted during AOC. |