| 1 | ENGAGEMENT OF jcb for removal of Bushes Clearance of Ground & Removal of Unhygenic materials as directed by EIC. |
| 2 | Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunk and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material. Beyond 30 cm girth upto and including 60 cm girth. |
| 3 | Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. 2.7.1 All kinds of soil : |
| 4 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil : |
| 5 | Supplying and laying of stone soling hand packed tightly incl ramming watering and filling of interstices incl all carriage complete job |
| 6 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering- All work upto plinth level.1:4:8 (1 cement: 4 coarse sand: 8 graded stone aggregate 40mm nominal size) |
| 7 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 8 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°,landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size |
| 9 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 10 | Centering and shuttering of kitply including strutting, propping etc. and removal of form work for: Foundations, footings, bases for columns |
| 11 | Beams |
| 12 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:4 ( 1 cement : 4 coarse sand) i/c Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level |
| 13 | Providing wood work in frames of doors, windows, clerestory windows & other frames, wrought framed & fixed in position first class imported ( KD WOOD) |
| 14 | Providing & fixing panelled or panelled & glazed shutters for doors & windows and clerestory windows including ISImarked black enamelled M.S Butt hingeswith necessary screws excluding panelling using imported wood 35mm thick |
| 15 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. : in Imported wood |
| 16 | Providing and fixing wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge : imported wood 35mm thick |
| 17 | Providing & fixing of 40x5mm flat iron hold fast 40cm long including fixing to frameswith 10mm dia bolts nuts &wooden plugs and embedding in cement conc block 30x10x5cm 1:3:6mix (1cement:3coarse sand:6 graded st agg)20mm nominal size |
| 18 | 15mm Cement Plaster on the rough side of single or half brick wall of mix 1:6(1 cement:6 fine sand) |
| 19 | 12mm Cement Plaster of mix 1:4(1 cement:4 coarse sand) |
| 20 | Providing and laying Ceramic glazed floor tiles (DOUBLE CHARGED) (thickness to be specified by the manufacturers) of 1st quality conforming to IS: 15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete. In colour such as White, Ivory, Grey, Fume Red Brown (KAJARIA, SOMANY , NITCO OR EQ)300x300 mm |
| 21 | P/L Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge:Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 22 | Extra for providing glass panes ) of ordinary glass panes windows and clerestory window shutters wt 10 Kg/sqm (Area of opening for glass panes excld portion inside shall be measured) |
| 23 | Providing and fixing of KHATAM BANDI ceiling of first class budloo/firwood i/c the cost of frame work (10mm plywood) i/c P/A PU wood polish over prepared surface after sandpapering , aplying sealer etc complete job: chaar gul |
| 24 | Providing and fixing 12mm thick wall paneling over 10mm thick framework of plywood i/c all fittings fastenings i/c P/A PU wood polish over prepared surface after sandpapering , aplying sealer etc complete job : ist class Imported wood |
| 25 | Priming coat with ready mixed Pink or grey primer of approved brand and manufacture on WOOD work (hard or soft wood) |
| 26 | Painting with synthetic enamel paint of app. Brand & manufacture to give an even shade 2 or more coats on new work |
| 27 | Finishing walls with textured exterior paint of required shade on New work (two or more coats applied @ 3.28 liter/10sqm) over and including base coat of exterior primer applied @ 2.20kg/10sqm |
| 28 | Reinforcement for RCC work incld straightning, cutting, bending, placing in position & binding all complete (Thermo-mechanically treated bars) |
| 29 | Structural steel welded in built up sections trusses and framed work incld cutting hoisting fixing in position and applying a priming coat of approved steel primer all complete |
| 30 | P/F track deck crill make or equivalent H.I rib color coated profiled sheets 1000 to 1020mm cover width 28-35mm high crests at 250 to 255mm TCT (total coated thickness) high tensile SMP Galvalume steel with silicon modified ployester coating of approved colour of total thickness of 35 micron comprising 20 micron exterior coat of SMP over 5 micron polyester back coat over 5 micron primer coats on both surfaces incld. side and end lap and using 8mm galvalume hex self drilling fastener on each crest of sheet for connection with purlins and seam bolts at 300mm centers on all side and end laps etc. (measured for unit of laid area)0.50mm THICK (TATA DURASHINE, JSW COLORON PLUS OR EQ) I/C ALL CARRIAGES |
| 31 | Providing ridges of hips of width 60cm overall width color coated plain sheets fixed with self drilling screws with EPDM Seal complete: 50mm thick |
| 32 | Providing and fixing plained eaves boarding. 2nd class kail wood 250x32 mm (nominal size ) |
| 33 | Providing and fixing soffit under roofs i/c framework using 12 mm thick imported wood panelling incl polishing complete |
| 34 | P/F ISI marked ornamental aluminium(coated) hardware fittings i/c all fastenings completeL-drop with lock |
| 35 | Handles 200mm |
| 36 | Handles 100mm |
| 37 | T Bolts 100mm |
| 38 | T Bolts 150mm |
| 39 | Hooks |
| 40 | P/F of MS railings&Grill using angles , hollow tubes ,pipe sections etc including welding,fixing in position , p/a priming coat and 2 coats of epoxy paint and all necessary fittings complete as per directions of engineer in charge |
| 41 | Providing and laying Ceramic glazed wall tiles (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make(KAJARIA, SOMANY, JOHNSON make) , in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), 600 x 600 mm size including pointing the joints with white cement and matching pigments etc., complete |
| 42 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 liter low level white P.V.C. flushing cistern, including flush pipe with manually controlled device (handle lever), conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors w herever required:W.C. pan with ISI marked white solid plastic seat and lid |
| 43 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer |
| 44 | Providing and fixing of mirror with built in shelf of superior quality (HINDWARE /RESPITE/JOHNSON make) with all fittings and fixtures complete. |
| 45 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-inchargeInternal work Concealed fixing the pipe with clamps at1.00 meter spacing including cutting chases and making good thewall etcPN-16 pipe, 16mm OD(SDR-7.4) |
| 46 | PN-16 pipe , 20mm OD(SDR-7.4) |
| 47 | Providing and fixing C.P. cock of approved quality (JAQUAR /JOHNSON /CERA /KEROVIT make) conforming to IS standards:15 mm dia. nominal bore |
| 48 | Providing and fixing Health Faucet of approved quality (JAQUAR /JOHNSON /CERA /KEROVIT make) conforming to IS standards: |
| 49 | Providing and fixing C.P. angle cock of approved quality (JAQUAR /JOHNSON /CERA /KEROVIT make) conforming to IS standards:15 mm dia. nominal bore |
| 50 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked(SINTEX HEAVY DUTY) with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 51 | Providing and fixing ball valve approved quality conforming to IS standards:20 mm dia. nominal bore |
| 52 | Providing and fixing of Towel rail of superior quality with all fittings and fixtures complete |
| 53 | Providing and fixing MS grating of approved quality and colour. 100 mm nominal dia. |
| 54 | Providing and fixing Polyvinyl Chloride (PVC) pipes(PRINCE TYPE-B HEAVY DUTY), incl all PVC plain fittings This includes jointing of pipes ,trenching ,refilling & testing of joints complete as per direction of Engineer in Charge.100mm |
| 55 | Constructing masonry main holes 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) with inside plastering with cement mortar 1:3 (1 cement :3 coarse sand) 12mm thick finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5. complete job |
| 56 | Providing and fixing of soap dish holder (JAQUAR make) with concealed fittings etc. |
| 57 | P/F Hot water geyser (50 ltr capacity) of approved design and make i/c all fittings complete |
| 58 | P/F Basin Mixer of standard make(JAQUAR/CERA or equivalent) as per specifications complete |
| 59 | P/F sink Mixer of standard make(JAQUAR/CERA or equivalent) as per specifications complete |
| 60 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :Kitchen sink without drain board 610x510mm bowl depth 200mm |
| 61 | Construction of Kitchen Cabinet using BWR 19mm thick ply board (ply to ply) for frames,shutters. The job shall include fixing ofdulmica of approved shade/texture on allexposed surfaces, inner linings prefrebly white (Mica), hardware fittings like hinges,handles, tower bolts. locks, hanger rail etc as per requirements of architectural drawingsor as directed by the Engineer-In-charge, complete job ) (600mm deep) |
| 62 | Carriage of material bajri /Bajriby mechanical means for an average lead of 50Km |
| 63 | Bricks |
| 64 | Steel |
| 65 | P/F PVC conduits 25mm dia (Finolex or equivalent brand) |
| 66 | P/F Light junction blocks complete as directed at site |
| 67 | P/F fan junction block complete as directed at site |
| 68 | Electric PartWiring for lighting points/fan points/exhaust fan points/call bell points with 2x1.5 sq mm FRLS/HFFR PVC insulated flexible stranded copper conductor wires in recessed or surface medium class PVC conduit, with 240V 6A modular switch ,modular plate, suitable GI box and earthing the point with 1.5 sq mm FRLS/HFFR PVC insulated copper conductor single core cable, etc. as required. (Havells/ Polycab/ Anchor/ SSK) including the cost of conduit. |
| 69 | Supply, Installation, Testing and Commissioning of 18W/+ LED recessed/mounted (round or square) Down lighters having aluminum body, minimum 100lm/w, average life 50000 hours, Operating temperature -10°C to +45°C.Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India.The job includes replacement warranty of fixture if damaged/ burnt out what so ever reason for a period of two years reckoned from the date of successful commissioning/ handing over of site to the intending department. (Havells/ Philips/ Crompton/ Jaguar/Wipro). |
| 70 | Supply, installation, testing and commissioning of 1200 mm (48”) BEE Star rated energy-efficient ceiling fan, complete with 3 Nos. aluminum blades, downrod, canopy, capacitor, safety pin, nuts, bolts and washers, suitable for 230 V, 50 Hz AC supply. The fan shall have air delivery not less than 220 m³/min, rated speed (RPM) between 340–380 (as per manufacturer’s specification), power consumption not exceeding 50 watts, service value ≥ 6.0, noise level ≤ 60 dB, insulation class ‘B’ and insulation resistance > 2 MΩ. Fan shall be of approved make such as Usha / Havells / Crompton / Orient or equivalent, including installation, online RPM verification, testing, commissioning and handing over to the Engineer-in-Charge, with minimum 2-year manufacturer warranty. |
| 71 | Supplying and fixing ISI-marked 6 A, 250 V modular step-type electronic fan regulator (2 Module), conforming to IS:3854 or latest IS standards, mounted on suitable modular plate with GI flush box, including wiring connections, testing and commissioning, of approved make such as Anchor Roma / Legrand / Schneider / Havells, complete as per direction of the Engineer-in-Charge. |
| 72 | Supply, Installation, Testing and Comm. Of 200/250mm sweep exhaust fan Shutter type of havell /Bajaj/ Crompton/equivalent make as directed by engineer incharge,Air Flow capacity >850cmph, 35-50Watts,Noise level 44db, 1200 rpm,water resistant, including making of space in wall/ window as per site requirement and necessary connections.The job includes replacement warranty of fixture if damaged/burn out what so ever reason for a period of two years reckoned from the date of sucessful commissioning / handing over of site to the intending department.(To be got approved before installation from EIC) |
| 73 | Supply, Installation, Testing and Commissioning of 50W (Havells/ PhillIps/Wipro skyline ) new generation energy saving and environmental friendly long life L.E.D Flood Light made up of pressure die cast Aluminum housing with high efficiency LEDs as lighting source with efficacy >110lm/w ,CRI>80 ,CCT>5000 ,Avg Life L70 50000 hours ,No haremful UV and IR radiators, Operating Temp -10°C to +45°C ,Surge Voltage Protection, IP66 Protection and impact resistance of IK07.The job includes replacement warranty of fixture if damaged/ burnt out what so ever reason for a period of two years reckoned from the date of successful commissioning/ handing over of site to the intending department. |
| 74 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch connections etc. as required.( Anchor roma plus/Legrand Mylinc /SSK/Schneider Zencelo /Crabtree athena make). |
| 75 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 No. 3 pin 5/6 A modular socket outlet and 5/6 A modular switch connections etc. as required.( Anchor roma plus/Legrand Mylinc /SSK/Schneider Zencelo /Crabtree athena make). |
| 76 | Wiring for AC/Power plug points (15/16A heating points) with 2x4 sq mm FRLS PVC insulated flexible stranded copper conductor wires in recessed or surface medium class PVC conduit along with 1x4 sq. mm FRLS PVC insulated copper conductor single core cable for earthing, etc. as required.(Havells/ Polycab/ Anchor/ SSK) including the cost of conduit. |
| 77 | Wiring for 5-10A socket out lets for computer with 2X2.5 sq. mm FRLS PVC insulated copper conductor (Havells/ Polycab/ Anchor/ SSK) as directed by engineer incharge.) single core cable in surface/recessed medium class PVC conduit, alongwith 1 No. 2.5 sq. mm FRLS PVC insulated copper conductor single core cable for earthing etc. as required including the cost of conduit. |
| 78 | Supplying and fixing of indicators on existing modular plate and switch box , incl. connections, etc. as required. (Havells/ SSK/ Anchor/ ABB/Schneider or equivalent). |
| 79 | Supplying and fixing modular blanking plate on the existing modular plate switch box excluding modular plate as recquired. |
| 80 | Supply and fixing of 8 way (4+24), Double door surface/ recess mounting, Horizontal type,three pole and neutral, sheet steel, MCB distribution board ,415V, dust protected, duly powder painted, inclusive of tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs, excluding cost of MCBs and Incomer. (Havells/Legrand/SSK/Schnider/ABB) |
| 81 | Supply, installation, testing and commissloning of 5-32A single pole rating 240/415V,10 KA \"C\" curve MCB of Legrand/ Havells/ L&T/ABB suitable for inductive load in the MCBdistribution board complete with necessary connections. |
| 82 | Supply, installation, testing and commissioning of 40A-32A DP rating 240/415V,10 KA \"C\" curve MCB of Legrand/ Havells/L&T/ABB suitable for inductive load in the MCB distribution board complete with necessary connections. |
| 83 | Supply, installation, testing and commissioning of 63A DP rating 240/415V,10 KA \"C\" curve MCB of Legrand/ Havells/ L&T/ABB suitable for inductive load in the MCB distribution board complete with necessary connections. |
| 84 | Main PanelDesign, fabrication, supply, installation, testing, and commissioning of Main Distribution Board (MDB), duly manufactured from CPRI-approved manufacturer, made out of 12 SWG CRCA (IS 375) mild steel sheet, 2 mm thick, powder-coated with RAL 7035, floor/wall-mounted, vermin and dust-proof, indoor type. The panel shall be provided with suitable size angle iron legs for grouting in the ground, lockable hinged doors, and painted finish. The enclosure shall have provisions for fixing switchgears,Aluminium bus bars of various ratings (considering derating factor), and other allied accessories as required. The panel shall be fabricated as per approved design; size may vary according to site requirements. The panel shall fully comply with IS 8623 / IEC 61439 standards for low voltage switchgear assemblies.The work includes all internal wiring, thimbles, ferrules, nuts, bolts, washers, gland plates, earthing lugs, insulation sleeves and all other accessories necessary to complete the panel in all respects as per site requirements.” |
| 85 | Providing and fixing of following protection equipments and other allied accessories including connections, inter connections, with suitable size of PVC insulated copper conductor cable including earthing etc. as required.1. Normal INCOMING:a)125A DP MCB 10 KA Havells/Legrand/ Schinider/ABB/L&T sample to be approved before installation.. |
| 86 | b) 4 No. of Aluminium Bus Bar of 300 Amp. |
| 87 | c)Digital meters and phase indicators -1 set. |
| 88 | 2.INVERTER a) 32A DP MCB 10KA |
| 89 | b) 2 No. of Aluminium Bus Bar of 63 Amp. |
| 90 | c) Digital meter and phase indicators 01 set. |
| 91 | Wiring for Circuit/Sub mains along with earth wire in FRLS PVC insulated 660/1100 volt grade flexible stranded copper conductor wires in recessed or surface conduiting system, including the cost of conduit. (Havells/ Polycab/ Finolex/ Anchor/KEI/RR or equivalent). 2x10 sq mm +1x6 sq mm Heating/AC submain |
| 92 | 2x 6 sq mm + 1x 6 sq mm Lighting submain |
| 93 | 2x 4 sq mm + 1x 4 sq mm Inverter submain |
| 94 | 2x 2.5 sq mm + 1x 2.5 sq mm inverter & normal Circuit |
| 95 | Supply, installation, testing and commissioning of 1625-2000 VA (2 kVA), 12 V, single-phase pure sine wave inverter with inbuilt charger and automatic changeover, conforming to IS 16242/IEC standards, including supply of 2 Nos. 12 V, 180 Ah tall tubular lead-acid batteries (IS 13369/IS 1651) mounted on PVC/FRP battery trolley, complete with interconnecting cables, terminals, DC fuse/isolator, AC wiring, initial charging, commissioning, and all accessories, duly approved by Engineer-in-Charge. |
| 96 | Supply, installation, testing and commissioning of 1.5 Ton, 3-Star Inverter type Split Air Conditioner (Hot & Cold), suitable for single phase 230V, 50Hz power supply, equipped with hermetically sealed rotary/inverter compressor using eco-friendly refrigerant R410A/R32, complete with indoor wall-mounted unit and outdoor condensing unit, wireless remote control, factory-charged refrigerant, and necessary mounting hardware. The work includes standard 5 metres of insulated copper refrigerant piping (suction and liquid line), interconnecting 3-core copper power/control cable, PVC condensate drain pipe, MS/GI wall mounting brackets with nuts, bolts, vibration pads for outdoor unit, drilling/core cutting through wall for passage of pipe and cable with proper sealing and finishing, fixing, alignment, pressure testing, vacuuming, leak testing, refrigerant top-up if required, electrical connections to existing point, test run, commissioning and demonstration at site. The job also includes making good any damages to wall or surface and providing one-year comprehensive on-site warranty/AMC after commissioning. Complete all as required at site and as directed by the Engineer-in-Charge. (Approved Make: Panasonic / Daikin / LG / Lloyd / Voltas / Godrej). |
| 97 | Supply, installation, testing and commissioning of 4 kVA automatic relay-type Voltage Stabilizer suitable for 1.5 Ton Split Air Conditioner, designed to operate on wide input voltage range of 90–260V and deliver stabilized output of 230V ±3%, complete with low/high voltage cut-off protection, time delay feature, wall/floor mounting arrangement, indicator lamps for input/output status, necessary wiring connections and fixing hardware, including testing and demonstration at site. The stabilizer shall be ISI-marked and of approved make. (Approved Make: V-Guard / Servokon / Microtek / Bluebird / Everest / equivalent), and sample shall be approved by the Engineer-in-Charge before installation. |
| 98 | Supply, Installation,Testing and Commissioning of Surface mount 25A MCB Box Protected Socket PVC plastic base incl. 25A plug top,with shutter for child safety and 25 A SPMCB inside a closed box. |
| 99 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.Complete Job. |
| 100 | Providing and laying earth connection from earth electrode with 8 mm dia copper wire in 15 mm dia G.l. pipe from earth electrode including connection with copper thimble excavation and re-filling as required. |
| 101 | Supplying,Laying and fixing of Suitable Fan Junction Box in Slab.sample to be approved by EIC |
| 102 | Providing and fixing of Deep boxes for lights in Slab,sample to be approved by EIC |
| 103 | Supply, laying, connecting and commissioning of 16 sq mm 2 core XLPE/ PVCInsulated and steel armored 1.1 KV grade Aluminum LT cable for Service line, incl. cost of required al. thimbles duly crimped. (Over head/ under ground). Please Enable Macros to View BoQ information |