| 1 | Sub-Head:I Operation and Annual Maintenance Contract of FF, FA, Talk Back and PA system |
| 2 | Schedule: A CSIR Complex, PUSA New Delhi |
| 3 | Operation and Annual Maintenance Contract ofFire fighting, Fire hydrant,Automatic fire detection, Talk back and PA System.The scope of work including the deployment of manpower is as per annexure: I |
| 4 | Schedule: B CSIR Hq., Rafi Marg, New Delhi |
| 5 | Operation and Annual Maintenance Contract ofFire fighting, Fire hydrant,Automatic fire detection, Talk back and PAsystem. The scope of work including the deployment of manpower is as per annexure: I |
| 6 | Schedule: C CSIR Scientist Apartments, Maharani Bagh, Ashram Chowk New Delhi |
| 7 | Operation and Annual Maintenance Contract ofFire fighting and Fire hydrant System.The scope of work including the deployment of manpower is as per annexure: I |
| 8 | SUB-HEAD: II :Supply and Installation of Fire Fighting Equipment |
| 9 | Providing, laying, testing & commissioning of \"C\" class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : |
| 10 | (a) 50 mm dia |
| 11 | (b) 65 mm dia |
| 12 | (c) 80 mm dia |
| 13 | (d) 100mm dia |
| 14 | (e) 150 mm dia |
| 15 | (f) 200 mm dia (Wall thickness 6.3 mm) |
| 16 | Supplying, installation, testing and commissioning of butterfly valve of PN 1.6 rating with bronze / gun metal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS:13095 of following sizes as required. |
| 17 | 65 mm dia |
| 18 | 80 mm dia |
| 19 | 100 mm dia |
| 20 | 150 mm dia |
| 21 | Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.(a) 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585(b) 20 mm nominal internal dia gun metal globe valve & nozzle.(c) Drum and brackets for fixing the equipmets on wall.(d) Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. |
| 22 | 30 m |
| 23 | Supplying, installation, testing and commissioning of fire alarm sounder with facility to make announcement, mounted in MS Box (16 SWG) with hinged cover plate and suitable for operation with amplifier i/c line matching transformer etc. as required. |
| 24 | Supplying, installation, testing and commissioning of manual call box of ABS type in surface / recess with stainless steel chain and hammer assembly complete with glass and push button etc. as required. |
| 25 | Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required. |
| 26 | Supplying, installation, testing & commissioning response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required. |
| 27 | Supplying, installation, testing & commissioning of heat detector operating at 54ºC/57ºC with rate of rise cum fixed temperature (dual thermistor) type with mounting base complete with all connection etc. as required |
| 28 | Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS/HFFR outer sheath complete as required. |
| 29 | Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. |
| 30 | Cleaning of underground tank with white wash including water removing and fillup the tank etc. complete as required. |
| 31 | Service charges for Liasoning up work from the Delhi Fire Service (DFS) for obtaining NOC (excluding NOC fees which would be reimbursed against the original copy of bill) for operation of Fire fighting and Fire Alarm system. In case of descripancies pointed by the DFS the same have to comply/ executed at their requirement. (All the extra work which is not cover under AMC will be payable to the firm.) |
| 32 | AandBchecks (replacement of complete kit i.e. oil filter, fuel filter, oil, coolant etc) of following Fire Diesel Engine Set as per the manufacturer\"s maintenance schedule. (A & B checks work of Fire DG Set shall be done only the Manufacturer / Authorized Sale & Services dealers of Kirloskar DG Set. |
| 33 | (a) 83 HP Fire Diesel Engine Set (CSIR HQ) |
| 34 | (b) 78.3 KW / 105 HP Fire Diesel Engine Set (CSIR MBSA) |
| 35 | (c) 50.78 KW / 69 HP Fire Diesel Engine Set (CSIR Cx) |
| 36 | Painting (one or more coats) on rain water, soil, waste, vent & fire pipes and fittings (i.e hydrant valves, NRV, landing valves and sluice valve) with synthetic enemal fire red paint of approved brand and manufacture and required (red) colour on old work. |
| 37 | (a) 100 mm Diameter Pipes |
| 38 | (b) 150 mm Diameter Pipes |
| 39 | Providing and fixing of 20 mm Stainless steel shut off nozzle in existing hose reel box including connection etc., as required. |
| 40 | Supplying & Fixing of Hose Cabinet of size750 x 600 x 250 made up 1.6 mm thick MS Sheet with 4 mm thick glazed glass doors i/c necessary locking arrangement suitable to accommodate 02 nos 15 mtr long hose pipe , 1 nos Branch pipe & duly painted with post office red externally & white internally with synthetic enamel paint complete in all respect etc as required. |
| 41 | Providing and fixing of pressure gauge (0-10 Kg/Sq.cm) in MS pipe including connection etc., as required. |
| 42 | Supply and fixingSS Female delivery Couplings 63 mm dia for hyndrant box valve etc complete in all respect. |
| 43 | Supplying and drawing 2x1.5 Sq.mm. sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 44 | Supplying, installation, Testing and commissioning of 12 V, 07 AH maintenance free batteries, including connection etc as required |
| 45 | Supplying, installation, testing & commissioning of main control and indicating panel made out of 16 SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections, interconnections etc complete as required.10 Zone panel for fire alarm system250 Watt amplifier racks suitable for operation on 230V AC/24V DC supply conforming to IEC-268-3 complete with all accessories as required - 2 Nos.(one to act as standby)Talk back master station with LED PTT (press to talk) push button for operation on 230V AC/24 V DC supply conforming to IEC-268 for simplex mode of operation/communication suitable for 20 Nos.talk back unit -1 set.Announcement control desk suitable for selection of different zones selectively and ON ALL CALL switch with visual indication etc. complete as required -1 set.Monitor panel for loudspeaker complete with output selector, ON/OFF switch, fuse, visual indications etc. complete as required- 1 No.Gooseneck microphone with stand and ON/OFF switch- 1 No.Main ON/OFF switch, fuse indication lamps, DC and AC voltmeters & ammeters, terminal blocks etc. complete as required -1 set.Battery charger trickle cum boost to take complete load of fire alarm & PA system complete with all accessories including providing & fixing of 2 nos.12 volt, 60 AH each sealed maintenance free batteries -1 set. |
| 46 | Supplying, installation, testing & commissioning talk back slave station in surface/recess suitable for operation on simplex mode complete with P.T.T. knob & speaker/microphone enclosed in a M.S.(16 SWG)/ ABS box with break glass in front etc. complete as required. |
| 47 | Supplying and fixing Single headed external/Internal yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required : |
| 48 | Single headed Stainless steel |
| 49 | Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet coupling complete with cap and chain as required for suitable dia MS Pipe connection confirm to IS:904 as required. 4 way-150 mm dia MS Pipe |
| 50 | Supplying, Installation, Testing and Commissioning of 19 mm x 30 meter swinging type first-aid Hose Reel complete reinforced braided thermoplastic red colour (Textile reinforced) type -2 as per IS: 12585 including connections etc complete as required. |
| 51 | Providing and fixing of 25 mm dia brass ball valve ISI marked along with all accessories including dismantling of existing 25 mm valve etc. complete as required. |
| 52 | Supplying, installation, testing and commissioning of Dry Chemical Powder/ ABCtype Fire Extinguisher of 5/6 Kg including dischage horn / pipe and all accessories / parts etc. complete in all respect. |
| 53 | Supplying, installation, testing and commissioning of Co2 4.5 Kg capacity Fire Extinguisher including dischage horn / pipe and all accessories / parts etc. complete in all respect. |
| 54 | Supplying, cutting to size, and fixing 4 mm acrylic sheet in existing fire hydrant cabin boxes of various sizes, including necessary gaskets, fittings, and all works, etc. complete as required |
| 55 | SUB-HEAD: III :Refilling of Fire Extinguishers |
| 56 | Refilling and repainting of Water CO2 of 9 litres capacity fire extinguishers including replacing damage discharge horn/ pipe and all damage parts etc complete in all respect. |
| 57 | Refilling & repainting of Co2, 4.5 Kg capacity fire extinguishers including replacing damage discharge horns / pipeand all damages parts etc complete in all respect. |
| 58 | Refilling and repainting of CO2, 3 Kg capacity fire extinguishers including replacing damage discharge horn/ pipe and all damages parts etc complete in all respect. |
| 59 | Refilling and Repainting of ABC type fire extinguishers of 1 kg capacity including replacing discharge horns and all damages parts, testing etc complete in all respect. |
| 60 | Refilling & repainting of ABC 5/6 Kgs capacity fire extinguishers including replacing damage discharge horns / pipeand all damages parts etc complete in all respect. |
| 61 | Refilling and repainting of foam type fire extinguishers, portable type 9 litre capacityincluding replacing damage discharge horn/ pipe and all damage parts etc complete in all respect.(CSIR CX) |
| 62 | Sub - Head V :- Buy Back Item |
| 63 | Salvage value of old / damaged fire extinguisher 5/6 Kg ABC \"As is where is basis\" |
| 64 | Salvage value of old / damaged Fire Alarm Panel all sizes \"As is where is basis\" |
| 65 | Salvage value of old / damaged Talk back system Panel all sizes \"As is where is basis\" |
| 66 | Salvage value of old / damaged fire extinguisherCO2 4.5 Kg \"As is where is basis\" |
| 67 | Salvage value of old / damaged 200 ltr diesel tank \"As is where is basis\" |
| 68 | Salvage value of old / damaged Sluice Valve 80 mm dia \"As is where is basis\" |