| 1 | Providing and laying two courses water proofing treatment with bitumen felt over roofs consisting of first courses of blown bitumen 85/25 or 90/15 conforming to IS : 702 applied hot @ 1.45 Kg per square metre of area for each course, second course of roofing felt type 3 grade-I (hessian based self finished bitumen felt)including preparation of surface but excluding grading complete with : Bitumen felt (hessian base) type 3 grade I conforming to IS : 1322 |
| 2 | \"Providing and Laying flash strip wherever required over roof including providing necessary safety measures for the labourers to work at higher elevation, ropes etc., insurance coverage for labourers and hiring of requiring T&P etc complete. |
| 3 | Supply and application of Dr.Fixit elastometric waterproof coating for G.I./Profile sheet roofs exposable to atmosphere. Thework consisting of (a) Application of single coat of Anti-corrosion Primer Dr.Fixit primer AC applied @3.70 ltr/10sqm over G.I.sheet. In case of profile sheet priming thethe surfacewith Dr.Fixit Cipoxy 16 D two component epoxy primer.(b) Application of two top coats of Dr.Fixit Cool Roof coating applied @ 1.25 ltr/10 sqm in forced consumption to achieve combine DFT of 400 micron.(The material purchasedby the contractor shall be as per the defined product specification and properties with proper test results as approved and directed by Engineer in charge). |
| 4 | Cleaning of drains by removing silt,sand,earth sludgeand dry leaves including cleaning other foreign if any such as organic/in organic materials etc.,for smooth running flow of rain water and disposal of cleaned material as directed by the Engineer-in-charge For drains width upto 0.3m |
| 5 | Cleaning of drains by removing silt,sand,earth sludgeand dry leaves including cleaning other foreign if any such as organic/in organic materials etc.,for smooth running flow of rain water and disposal of cleaned material as directed by the Engineer-in-charge For drains width above 0.3m |
| 6 | Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared. |
| 7 | Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil |
| 8 | Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all completeWith second class teak wood beading 62X19 mm |
| 9 | Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all completeWith second class teak wood beading 62X19 mm |
| 10 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 11 | \"Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows(Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick :Second class teak wood\" |
| 12 | \"Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. With cement mortar 1:4 (1 cement : 4 fine sand) \" |
| 13 | \"Dismantling of flexible pavement (bituminous courses) by mechanical means and disposal of dismantled material up to a lead of 1 kilometre, as per direction of Engineer-in-charge.\" |
| 14 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 15 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 16 | \"Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from naturalsources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) \" |
| 17 | \"Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete work in string courses, bands, copings,bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but , excluding cost of reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). \" |
| 18 | \"Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. \" |
| 19 | \"Supplying and filling in plinth with river sand under floors, including watering, ramming, consolidating and dressing complete. \" |
| 20 | Centering and shuttering including strutting, propping etc. and removal of form for :Foundations, footings, bases of columns, etc. for mass concrete. |
| 21 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 22 | Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 23 | \"Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Cold twisted bars \" |
| 24 | \"Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 5 in foundation and plinth in: cement mortar 1:6( 1cement:6 coarse sand) |
| 25 | \"Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 5 in superstructure above plinth level to floor V in all shapes and sizes incement mortar 1:6( 1cement:6 coarse sand) |
| 26 | \"Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand) \" |
| 27 | \"15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 fine sand) \" |
| 28 | \"12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand) \" |
| 29 | \"Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content.With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
| 30 | \"Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @0.9 kg/10 sqm). \" |
| 31 | \"Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre. of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.Two coats. |
| 32 | \"Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS :15622 of approved make in all colours, shades, except White, Ivory, Rey, Fume Red Brown laid on 20mm thick bed of Cement Mortar 1:4(1 Cement : 4 Coarse sand) jointing with grey cement slurry @ 3.3kg per sqmincluding pointing the joints with white cement and matching pigments etc., complete. \" |
| 33 | \"Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. \" |
| 34 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades,laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqmincluding grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm |
| 35 | \"Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 100x100 mm size P type With common burnt clay F.P.S. (non modular) bricks of class designation 3.5 \" |
| 36 | \"Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm\" |
| 37 | \"Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per directionof Engineer - in - charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) \" |
| 38 | \"Providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarseand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) \" |
| 39 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :Of area 3 sq. metres and below |
| 40 | Dismantling steel work manually/ by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per direction of Engineer-in-charge. |
| 41 | \"Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Frame size 50 x 100 mm |
| 42 | \"Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) 30 mm thick\" |
| 43 | \"Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) 30 mm thick \" |
| 44 | \"Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 125x64x1.90 mm |
| 45 | \"Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : 250x10 mm\" |
| 46 | \"Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 100 mm \" |
| 47 | Providing and fixing bright finished brass door latch with necessary screws etc. complete :300x16x5 mm |
| 48 | \"\"\"Providing and fixing aluminium hanging floor door stopper, ISI marked,anodised (anodic coating not less than grade AC 10 as per IS : 1868)transparent or dyed to required colour and shade, with necessary screws etc. complete. Single rubber stopper |
| 49 | Providing and fixing unplasticized Polyvinyl Chloride (uPVC) pipes,including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.110 mm nominal dia Pipes.\" |
| 50 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes |
| 51 | \" Providing and fixing PTMT stop cock of approved quality and colour. 20 mm nominal bore, 89 mm long, weighing not less than 88 gms |
| 52 | Providing and fixing brass stop cock of approved quality : 15 mm nominal bore. |
| 53 | Providing and fixing brass bib cock of approved quality :15 mm nominal bore. |
| 54 | \"Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15 mm nominal bore. |
| 55 | Providing and fixing white vitreous china pedestal type water closet(European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid |
| 56 | \"Providing and fixing water closet squatting pan (Indian type W.C.pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls andfloors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 57 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :range of four urinal basins with 10 litre white P.V.C. automatic flushing cistern |
| 58 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Surgeon type wash basin of size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 59 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. |
| 60 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. |
| 61 | Providing and fixing factory made Upvc glazed/wire mesh windows/doors comprising of lead free Upvc multi-chambered frame,sash and mullion/coupler(wherever required) extruded profiles having minimum wall thickness of 1.70mm for seriesR1 and R2 profiles and 2.10mm for series R3 and R4 profiles conforming to EN:12608 in any shape,colour and design duly reinforced with galvanized mild steel section made of required shape and size as per CPWD Specification ,uPVC extruded glazing beads,interlocks and inline sash adaptor(where ever required)of appropriate dimension,EPDM gasket,hardware,SS 304 grade fasteners of minimum 8mm dia with countersunk head,comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367:Part 1 to 14,plastic packers,plastic caps and necessary stainless steel screws etc.profile of frame,sash & mullion(if required) shall be mitred cut and fusion welded /mechanically jointed duly sealed at all corners including drilling of holes for fixing hardware and drainage of water etc after fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality,all complete as per approved drawing conforming to CPWD Specification and direction of engineer in charge.section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by engineer in charge.wire mesh/glazing of plain/tughened/laminated/double glass unit with/without high performance coatings as per design reqirements and conforming to IS 3548 & IS 16231 shall be paid separately.Two track two panels sliding window with Aluminium channel for roller track,wool pile ,nylon rollers with SS 304 body.Using R2 series wit frame (40 mm & above)x (40 mm & above) & sash (25mm & above)x(50mm & above) with zinc alloy(zamak) powder coated touch locks with hooks (height upto 1.2m) |
| 62 | Ventilator casement window single panel with or without fixed panel with S.S.304 friction hinges as per size and weight of sash,single point locking zinc alloy(zamak) powder coated handles.Using R1 series with frames (33mm & above)x(35mm & above) & sash /mllion(33mm & above)x(50mm & above)(height upto 0.9m) |
| 63 | \"Providing and fixing aluminium work for doors, windows, ventilatorsand partitions with extruded built up standard tubular sections/appropriate Z sections andothersections of approved make conforming to IS: 733 and IS: 1285, fixing withdashfasteners ofrequired dia and size, including necessary filling up the gaps at junctions, i.e.at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required includingcleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :Powder coated aluminium (minimum thickness of powder coating 50 micron) \" |
| 64 | \"For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)\" |
| 65 | \"Providing and fixing 12 mm thick prelaminated particle board flatpressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixedaluminum doors, windowsshutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer in-charge. Pre-laminated particle board with decorative lamination on both sides. \" |
| 66 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4 mm thickness (weight not less than 12.50 kg/sqm)\"\"\" |
| 67 | Providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with :4.0 mm thick glass panes |
| 68 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) |
| 69 | \"Renewing glass panes, with wooden fillets wherever necessary: Float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm)\" |
| 70 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes |
| 71 | \"Providing and fixing precoated galvanised iron plain profile sheets 0.50 mm (+ 0.05 %), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required\" |
| 72 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of:G.S. Sheet |
| 73 | Providing and fixing radial exhaust turbo ventilator (extraction capacity of minimum 100 cft per minute air circulated fan of 22\" throat dia wind ventilator with FRP base plate) including cost of fixing turbo/ wind ventilators on new 0.510mm thick pre-coated GI profile sheet roofing on godown roof including cost of transportation of all materials, tools and plants, fixtures/fastenings, labour insurance safet measures etc., and as directed by the Engineer-in-charge inlcuding guarantee for turbo ventilator of minimum 3 years and performance warranty etc., complete. |
| 74 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 75 | Cleaning of A.C/G.I valley gutter of any size by removing the branches / leaves of fallen trees / dust / silt and any other foreign matters over the gutter surfaces & removing blockage at inlet of the down water pipes for free flow of water to avoid floading / splashing of rain water. |
| 76 | Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated \"J\" or \"L\" hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified.2 mm thick corrugated (2.5\" or 4.2\" or 6\") or step-down (2\" or 3\" or 6\" ) as specified |
| 77 | \"Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement :2 coarse sand : 4 stone aggregate 10 mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design In 75x75 mm deep chase \" |
| 78 | Providing and laying 60mm thick factory made cement concrete interlocking paver block of M- 30 grade made by block making machine with strong vibrator compaction, of approvedsize, design & shape , laid in requiredcolour andpattern over and including50mm thick compacted bed of coarse sand, filling the joints with line sand etc., all complete as per the direction of Engineer-in-charge. |
| 79 | \"Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stoneaggregate 20 mm nominalsize derived from natural sources) over 75mmthick bed of dry brick ballast 40 mm nominal size, well rammed andconsolidated and grouted with fine sand, including necessary excavation,levelling & dressing & finishing the top smooth. \" |
| 80 | Fencing with angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per 100 m (minimum), between the two posts fitted and fixed with G.I.staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for separately). Payment to be made per metre cost of total length of barbed wire used. With G.I. barbed wire |
| 81 | \"Repurchase price of dismantled materials (to be paid by (or recovered from the contractor work bill) inclusive of cost born for loading and unloading etc by the contractor Dismantled steel/iron flats,bolts,nuts, sheets etc. |