Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Part A-Civil and Interior Works |
| 2 | Demolition works : Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. (Page no 187 . item no 19.7.3,BLD SR 2023-24)-Vol 2 |
| 3 | Dismantling works : Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking to the appropriate disposal area as per direction of Engineer-in-charge. (Page no 188 . item no 19.12.2, BLD SR 2023-24)-Vol 2 |
| 4 | Dismantling works : Dismantling wood work in frames, trusses, purlins and rafters upto 10 metres span and 5 metres height including stacking to the appropriate disposal area as per direction of Engineer-in-charge.( Page no 188 . item no 19.14.1,BLD SR 2023-24)-Vol 2 |
| 5 | Demolition works :Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. ( Page no 187 . item no 19.3,BLD SR 2023-24)-Vol 2 |
| 6 | Clearing site : Removing of existing old or broken wash basin / urinals/ Indian Water closet/ European Water closet and disposing it with all cost and conveyance labour for all items of work, HOM with all lead and lift, loading and unloading, transportation charges and all other incidental charges etc., complete as per specification and directions of the Engineer-in-charge of the work. ( Page no 209 . item no 20.123,BLD SR 2023-24)-Vol 2 |
| 7 | Dismantling works :Dismantling tile work in floors and roofs laid in cement mortar including stacking material to the appropriate disposal area as per direction of Engineer-in-charge. ( Page no 189 . item no 19.22.1,BLD SR 2023-24)-Vol 2 |
| 8 | Anititermite treatment : Providing, diluting and injecting chemical emulsion for Post-constructional antitermite treatment with Chlorpyriphos/ Lindane E.C. 20% with 1% concentration. ( Page no 5 . item no 4.2 ,BLD SR 2023-24)-Vol 2 |
| 9 | Laterite Masonary : Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Super structure in CM 1:6 ( Page no 9 . item no 5.7,BLD SR 2023-24)-Vol 2 |
| 10 | Solid Block Masonary : Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications ( Page no 17 . item no 6.33,BLD SR 2023-24)-Vol 2 |
| 11 | 12mm cement plaster : Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand)including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Page no 41 . item no 8.1.1,BLD SR 2023-24)-Vol 2 |
| 12 | 18mm cement plaster : Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Page no 42 . item no8.9,BLD SR 2023-24)-Vol 2 |
| 13 | 15mm cement plaster: Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Page no 41 . item no 8.2.1,BLD SR 2023-24)-Vol 2 |
| 14 | P.C.C Bed toilet area : Providing and laying in position Cement Concrete M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. ( Page no 16 . item no 2.5.1 UNI SR 2023-24) |
| 15 | Vitrified Tiles : Providing and laying Vitrified tiles of size 600 X 600mm with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser, treads of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints as per direction of Engineer in charge. ( Page no 61 . item no 9.19,BLD SR 2023-24)-Vol 2 |
| 16 | Granite Flooring : Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent.( Page no 63 . item no 9.24,BLD SR 2023-24)-Vol 2 |
| 17 | Wall tile and Dadoing : Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ( Page no 65 . item no 9.39,BLD SR 2023-24)-Vol 2 |
| 18 | Water proofing : Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. (Page no 149. item no 15.1, BLD SR 2023-24)-Vol 2 |
| 19 | Gypsum Partition: Providing and laying Gypsum panel partitions 100 mm thick with water proof Gypsum panels of size 666x500x100 mm, made of calcite phosphor Gypsum fixed with tongue and groove, jointed with bonding plaster as per manufacturer’s specifications in superstructure above plinth level up to floor I level. Gypsum blocks will have a minimum compressive strength of 9.3 kg/cm2 including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.( Page no 16 . item no 6.27,BLD SR 2023-24)-Vol 2 |
| 20 | Cement based putty : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ( Page no 50 . item no 8.51,BLD SR 2023-24)-Vol 2 |
| 21 | Cement Primer : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ( Page no 45 . item no 8.27,BLD SR 2023-24)-Vol 2 |
| 22 | Wall painting : Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. ( Page no 50 . item no 8.54.2,BLD SR 2023-24)-Vol 2 |
| 23 | Acoustical flase ceiling : Providing & Fixing of High Acoustical False Ceiling having NRC (Noise Reduction Coefficient) 0.90 (minimum) using Integral Densified edged Eco Friendly Fully Perforated Lightweight Calcium Silicate False Ceiling Tiles with Suitable to Modular Grid Size of 600x600mm with PPGI Slimline profile Balck/White reveal T 15 Grid system for Auditoriums, Community halls, Lecture Halls, Airports, Offices, Factories and All other High Acoustics required buildings. The Fully Perforated Lightweight Calcium Silicate False Ceiling tiles shall be made from Non Cementitious Hydrated Calcium Silicate Slurry/Mixture, Reinforced recycled material with fibers and natural fillers. Free from Formaldehyde and other harmful materials. Doesn\"t contain any toxic ingrediants. The thickness of tiles should be 15mm at all around the edge resting portion with integral densified edge and 10mm thick at the quadrant. The tiles should have fiber glass fleece on rear side along with backing of 50mm thick rockwool slabs of density 48kg/m3 to achieve NRC 0.90 (Minimum). The tiles should have Humidity Resistance (RH) of 100%, Water Resistance, Non Combustible as per BS:476 Part-4, Fire Performance: Fire Propagation as per BS:476 Part-6, Class-1 for Surface Spread of Flame as per BS:476 Part7, Class A or Class 1 as per ASTM E 84, Thermal Conductivity K= 0.048 to 0.052 w/m K as per ECBC code 2007, Size of the tile is 595x595mm, Density of tile should be 450 kg/m3 density all around on edge resting portion and 350kg/m3 density at the Quadrant, Light Reflectance > 85%, Weight of the tile is 5-5.5 kg/m2 and Suitable for Green Building application with InOrganic Recycled content of 50% and meets the GRIHA norms under the categories: GRIHA V.2015 criterion:11&12, GRIHA V.3 criterion: 17&29 and SVAGRIHA criterion:12. The tiles Shall be laid on 15mm wide Polyester Powder Coated Galvanized Iron (PPGI) Slimline Profile Black/White reveal T-Sections Flanges colour white having rotary stitching double webbed on all T sections. The framework shall comprise of Main T runner with a web height of 38mm and 1200mm & 600mm Cross Tees with a web height of 38mm having sheet thickness of 0.4mm. The T sections should have Galvanizing of 120 g/m2and need to be installed with Suspension system consisting of 12x50mm long dash fastners, Z cleat 25x37x25x1.6mm with pre cut hole on both 25mm flange to accomdate the 6mm dia bolt of the fasterner on one flange and 6mm fully threaded hanger rod uptom 1000mm length on the other. L-shape level adjuster of size 76x25x1.6mm to be fixed with T grid main runner. The entire grid rests on the perphery on a pre coated GI wall angle of size 15x20mm of sheet thickness 0.40mm of length 3000mm to be fixed on periphery wall/partition with the help of plastic rawl plugs at 450mm center to centerand 40mm long s.s screws. The work shall be carried out as per specifications, drawings and as per direction of Engineer in Charge. ( Page no 37 . item no 7.66,BLD SR 2023-24)-Vol 2 |
| 24 | Grid Ceiling : Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 g/m2 , both side inclusive) consisting of main \"\"T\"\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \"\"T\"\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \"\"T\"\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \"\"T\"\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \"\"T\"\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. 8 mm thick fully perforated calcium silicate board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process to give stable crystalline structure with minimum compressive strength 225 kg/cm2, bending strength 100 kg/cm2, of size 595x595 mm, having perforation of dia. 10 mm with minimum perforated area 18 % with non woven tissue on the back side, having an NRC ( Noise Reduction Coefficient) of 0.85, with 50 mm thick rockwool of 48 kg/m3 backing. ( Page no 30 . item no 7.47.1,BLD SR 2023-24)-Vol 2 |
| 25 | False Ceiling : Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 g/m2 (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) : 2011 (Board with BIS Certification marks only)( Page no 25 . item no 7.32 ,BLD SR 2023-24)-Vol 2 ,( Page no 25 . item no 7.32.1,BLD SR 2023-24)-Vol 2 |
| 26 | Door shutters : Providing and fixing Teak wood plain jaffri door and window shutters including bright or/and black enamelled M.S. butt hinges with necessary screws 35x10 mm laths placed 35 mm apart (frames to be paid separately), including fixing 50x12 mm beading complete with : ( Page no 199 . item no 20.21,BLD SR 2023-24)-Vol 2 |
| 27 | Sal wood frames : Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ( Page no 100 . item no 12.13.1,BLD SR 2023-24)-Vol 2 |
| 28 | Fixing of door frames :Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ( Page no 104 . item no 12.51,BLD SR 2023-24)-Vol 2 |
| 29 | Glass doors : Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc. to be paid separately) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.( Page no 94 . item no 11.52,BLD SR 2023-24)-Vol 2 |
| 30 | Wooden pelmet : Providing and supplying 19mm thick both side balancing lamination factory pressed BWP grade marine ply as per IS 710 of approved brand boxes,shelves,racks,almirah,cupboard and drawer etc. including necessary nails,screws etc. complete as per direction of Engineer-in-charge. ( Page no 217 . item no 22.6,BLD SR 2023-24)-Vol 2 |
| 31 | Labour & installation charges for BWP ply:BWR ply:HDHMR: MDF & Particle board work of any thickness applicable for all types of work ( Page no 218 . item no 22.8,BLD SR 2023-24)-Vol 2 |
| 32 | Acoustical Wall Paneling: Providing and supplying \"Acoustical Wall Paneling\" with square edges made of fibre glass substrate 25mm thick and wrapped on the front side with an acoustically transparent and classified for Fire reaction Class A, as per ASTM E-84, fabric with option of colors - as per the choice of the Architect/Engineer incharge of the size 600x600mm, 600x1200mm & 600x1800mm providing a minimum sound absorption level of 0.85 NRC to be affixed to wall using Wall panel lmpaler sand construction adhesives as per the instructions laid down by the certified manufacturer.( Page no 32 . item no 7.51,BLD SR 2023-24)-Vol 2 |
| 33 | ACP Panneling :Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick/Rcc/stone walls & coloumns/beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick non-halogenated FR grade mineral based polymer ( 2 hrs fire resistance as per ASTM E119-12 and clause B, S1, do as per ENT 13501-1sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories, sealing shall be done with necessary rods etc., complete. For straight portions( Page no 71 . item no 10.15.1 ,BLD SR 2023-24)-Vol 2 |
| 34 | M.S Grills : Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ( Page no 86 . item no 11.34 A ,BLD SR 2023-24)-Vol 2 |
| 35 | Steel Frame works : Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharg.( Page no84 . item no 11.25.2,BLD SR 2023-24)-Vol 2 |
| 36 | Painting of steel works : Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ( Page no 47 . item no 8.33.3,BLD SR 2023-24)-Vol 2 |
| 37 | Wood Polishing : Polishing on wood work with ready mixed wax polish of approved brand and manufacture : New work to give an even surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ( Page no 49 . item no 8.47,BLD SR 2023-24)-Vol 2 |
| 38 | Polyester Curtians : Providing & fixing 100% Polyester Curtains with specification of regular washas per direction of Engineer in charge ( Page no 219 . item no 22.24,BLD SR 2023-24)-Vol 2 |
| 39 | Wall mount mirror : Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :( Page no 136 . item no 14.32 ,BLD SR 2023-24)-Vol 2 Rectangular shape 1500x450 mm ( Page no 136 . item no 14.32.4,BLD SR 2023-24)-Vol 2 |
| 40 | Robe Hook : Providing and fixing Robe hook twin made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Premium( Page no 144 . item no 14.83,BLD SR 2023-24)-Vol 2 |
| 41 | Towel Rail : Providing and fixing Towel rail (Circular) made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Premium ( Page no 144 . item no 14.86,BLD SR 2023-24)-Vol 2 |
| 42 | Toilet paper holder : Providing and fixing Toilet paper holder made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class premium ( Page no 145 . item no 14.93,BLD SR 2023-24)-Vol 2 |
| 43 | Unanticipated work - Semi-skilled Labour ( Government of India ,Ministery of Labour & Employment office of chief labour commissioner ) |
| 44 | Unanticipated work - Unskilled Labour ( Government of India ,Ministery of Labour & Employment office of chief labour commissioner ) |
| 45 | Part A1-Civil and Interior Works (non coded item) |
| 46 | Internal Wall Painting :Providing and applying 2 coats of emulsion paints of approved make (LOW - VOC paint complying with limits <100g/ltr) washable premium emulsion, stain guard, long lasting, fungus and mildew resistance, rich and matt finish, super-acrylic emulsion over one coat of easy brushing, excellent covering, alkali resistance, quick drying and good sealing properties interior primer over 2 coats of white cement based with re dispersible polymer and functional additives smooth putty to the internal walls, as per directions including providing and removing scaffolding, providing of masking tape wherever necessary finishing etc., complete. Application system - Cleaning the surfaces + crack filling (Up to 3 mm by smartcare crack seal)+ 2 coats of true care wall putty+1 coat of interior royale wall base coat+ 2 coats of royale health shield interior emulsion with the dilution of 40%.Contractor to assess all the existing wall finishes in all areas individually & ensure the required final finish is attainable, without any major additional working/cost, and if required, to instruct the Civil working team during the costing itself, so that cost is included. Including the cost of scaffolding, labour, tools and tackles at all levels |
| 47 | Baffle Ceiling: Providing & Fixing of Aluminium Baffle Ceiling System consists of Baffle Panel of Extruded profile of size 50 x 150 x 1.3mm thickness. These Baffle panels are coated color as per Architect approval . The Baffle panels are fixed on to the \"C\" type GI Carrier in Black color which has slots of definite spacings as per the design requirement. This way the Baffle panels are fixed at definite spacings as per design using Bolt and Nut. The C Carrier is then suspended at every lmtr with 6mm threaded rod, where one end is connected to the carrier and the other end with anchor fastner fixed on true ceiling. The panel ends are then closed with end caps which are also with same color matching the panels. |
| 48 | Fixed Glass:Provind and fixing of 12mm toughened glass using profile fittings of approved make including cost of all materials, labour, transportation, complete as per specification. |
| 49 | Wooden Partition: Providing and fixing of woodwen partitionusing 710 grade ply of 12mm thick for panelling and 19mm thick for framing (All plywood make Greenply/Kenwood/Century/Equivalent) and all outside surfaces covered using 1mm laminate of Merino/ Aica/ Equivalent. including cost of all materials, labour, transportation, complete as per specification. |
| 50 | Wooden Panelling:Providing and fixing of wall panelling using 710 grade ply of 12mm thick for panelling and 19mm thick for framingof approved make and all outside surfaces covered using 1mm laminate of Merino/ Aica/ Equivalent. including cost of all materials, labour, transportation, complete as per specification. |
| 51 | Wooden sliding doors: Providing supplying & Fixing of sliding fush door made with plywood framework withnlaminate finish , as per drawing providedIS 710 BWP flush door of 30 mm thk door shutter of of approved make with , and finished with 1mm laminate including cost of lipping teak wood beading size 32mm x 12mm, melamine polished with matching colour shade, delivery to site with necessarypacking to avoid damages all edges/sides finished, provision of handle, lock and Slider channel and allnecessary hardware as per selection |
| 52 | Veneer Panelling: Providing and fixing of wall panelling using 710 grade ply of 12mm thick for panelling and 19mm thick for framing (All plywood makeof approved makeand all outside surfaces covered using 4mm veneer of Green/Kenwood make finished with machine sprayed melamine polish as per recommandation.. including cost of all materials, labour, transportation, complete as per specification. |
| 53 | Fluted Panelling: Wooden Panelling: Providing and fixing of wall panelling using 710 grade ply of 12mm thick for panelling and 19mm thick for framing of approved make and fixing of PVC fluted panel as per selection. including cost of all materials, labour, transportation, complete as per specification. |
| 54 | Aluminium sliding Windows: Providing and fixing in position 3 track 2 glass 1 mesh aluminium sliding windows as per approved drawingswindow frame of 27mm shutter width of approved make bottom section of minimum 1.1mm thick, shutter interlock section, the shutters mounted on nylon rollers with approved quality of fixtures such as aluminium handles/locks, providing and fixing 5mm thick plain glass for shutters fitted with EPDM gaskets on all aluminium sections 40microns powder coating of approved colour and selection, frames cutting to required length, joints mitred subdividing the frame tenonned and riveted, in the assembled frame, stiffened with end clips for corners, angles etc., and fixed to the walls, lintels, floor beams/sills as the case may be, with necessary steel screws, raul plugs or teak wood gatties including cutting masonry or concrete and making good the original surface using cement mortar, including cost of materials, labour complete as per specifications |
| 55 | Ventilator with mesh :- Providing, fabricating and fixing in position Aluminium powder coated louvered ventilators with mosquito meshusing aluminium extruded sections of size 62mm x 31.50mm x 2mm thick at 0.778 kg/m confirming IS 733 and IS 1285 and 4mm thick glass louvers with provision for all as per drawing including necessary chipping, making holes in RCC columns, masonry with power drill to the extent required and making good the same to the original condition after fixing etc. complete. including sealing the gap between masonry and frame with approved quality sealant etc. complete |
| 56 | Urinal Partition: Providing and fixing urinal partitionsystems with 12mm thick solid Compact Laminate panels(HPL) having high density,which should be resistant to water/fire/scratch & comes with anti-bacteria layer, water immersion through permissible increase on weight should be minimal. Finished product should be as per approved texture, shade & drawing, detailing and developed according to IS-2380 standards. |
| 57 | Toilet Cubicles: Providing and fixing toilet cubicle nsystems with 12mm thick solid Compact Laminate panels(HPL) having high density, including doors, pilasters & intermidiate panels, which should be resistant to water/fire/scratch & comes with anti-bacteria layer, water immersion through permissible increase on weight should be minimal. Finished product should be as per approved texture, shade & drawing, detailing and developed according to IS-2380 standards |
| 58 | Aluminium skirting : Providing and fixing aluminium skirting using 4\" anodised aluminium skirting and necessary rubber beedings to cover the screw.The rate shall include the cost for all overheads, HOM, lift, lead, transportation, labour, wastage, scaffolding, etc, complete as per the directions of the engineer in charge. |
| 59 | Ceiling Access Panel: Supplying and installation of Ceiling access panels of Size (600 x 600mm Clear size) with Non-fire rated standard aluminium access panel frames (Aluminium Alloy 6063, Temper 6) areelectrostatic powder coated white, with MR Grade Gypsum board facing, Providing easy access to gypsum ceilings. Each panel features a Allen key lock closing mechanism,with door retaining safety cable and hook. Pivot spring mechanism for locking and pivoting application. |
| 60 | Marble Flooring: Marble stone flooring with 18mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20mm (average) thick base of cement mortar 1:4 (1 cement: 4 coarse sand) laid and joined with grey cement slurry, including rubbing polishing complete. |
| 61 | Laminated Vinyl Plank Flooring:-providing and fixing of laminated vinyl plank of click and lock type, anti skid and anti scratch resistant, 5mm thk with 0.3mm thk wear layer, fire resistant as per selection, over existing vitrified floorinbg / PCC bed over foam backing. The rate shall include the cost for all overheads, HOM, lift, lead, transportation, labour, wastage, etc, complete as per the directions of the engineer in charge. (Base rate of the tile = 1050 Rs.Sq.m excluding GST) |
| 62 | Quartz Flooring: Quartz stone flooring with 18mm thick quartz stone, as per sample of quartz approved by Engineer-in-charge, over 20mm (average) thick base of cement mortar 1:4 (1 cement: 4 coarse sand) laid and joined with grey cement slurry, including rubbing polishing complete. |
| 63 | Anti Skid /Sports Flooring - Supplying and fixing of 6.5mm thicksports flooring for gym room including welding rod and necessary adhesive . Rate inclusive of material, Labour and transportation complete as per specification |
| 64 | Wooden Flooring : Providing and fixing 8mm thk HDF.approved color laminated wooden flooring of approved make of AC4 grade (15 years warranty)laid on a levelled surface finished with 2mm P.U.Foam.(The make,Shade,Pattern etc..,to be approved by Architect). |
| 65 | TKT Ceiling: Providing and fixing 12mm thick TKT/PVC celing using GI celing sections and intermediate channels with all other neessary supports required complete as per standards. Rate inclusive of all the materials, Labour and transportation complete as per specification. |
| 66 | Fluted Panel Ceiling: Providing and fixing PVCFluted Panels The panel should be of approved shade, size and make and to be properly fixed plywood frame work pf 19mm andf 12mm on surface . The rate includes the Cost of all the Materials, labour, and transportation complete as per specification. |
| 67 | Baffle Cloud Ceiling: Providing and fixing seamless false ceiling withWood fibre clouds of required shape and sizefixed along the wall/partition using Nylon sleeves suspended using rawl plug or soffit cleat. As per design. The rate including the Cost of all the Materials, labour, and transportation complete as per specification. |
| 68 | Furnitures : Supply as per the drawing made using approved quality IS710 BWP plywood of approved makeoutside surfaces finished with 1mm SF laminate as per approved shade and colour as per selection by Architects/Engineer incharge and inside surfaces finished 0.8mm off white decoliner laminate of approved make of approved shade and colour as per selection by Architects/Engineer incharge, edges finished with matching edge banding finishing wherever necessary, with all the necessary hardware such as powder coated drawer channels, SS auto-closing hinges, handles and wire managers etc. wherever necessary including cost of all labours, shifting, wastage, loading, unloading to the site complete. WR-01: Wardrobe @ Deluxe room walkin closet- L- 2.00M X 3.0M - 4 nos |
| 69 | Furnitures : Supply as per the drawing made using approved quality IS710 BWP plywood of approved makeoutside surfaces finished with 1mm SF laminate as per the of Merino / Sunmica / Greenlam of approved shade and colour as per selection by Architects/Engineer incharge and inside surfaces finished 0.8mm off white decoliner laminate of approved make of approved shade and colour as per selection by Architects/Engineer incharge, edges finished with matching edge banding finishing wherever necessary, with all the necessary hardware such as powder coated drawer channels, SS auto-closing hinges, handles and wire managers etc. wherever necessary including cost of all labours, shifting, wastage, loading, unloading to the site complete. WR-02: Wardrobe @ Suit room walk-in closet - L- 2.98 M X 3.0M - 2 Nos |
| 70 | Furnitures : Supply as per the drawing made using approved quality IS710 BWP plywood of approved makeoutside surfaces finished with 1mm SF laminate as per the of Merino / Sunmica / Greenlam of approved shade and colour as per selection by Architects/Engineer incharge and inside surfaces finished 0.8mm off white decoliner laminate of approved make of approved shade and colour as per selection by Architects/Engineer incharge, edges finished with matching edge banding finishing wherever necessary, with all the necessary hardware such as powder coated drawer channels, SS auto-closing hinges, handles and wire managers etc. wherever necessary including cost of all labours, shifting, wastage, loading, unloading to the site complete. TV-01 : TV Unit @ Deluxe room living area - L -2.40 M X2.10M - 2Nos |
| 71 | Furnitures : Supply as per the drawing made using approved quality IS710 BWP plywood of approved makeoutside surfaces finished with 1mm SF laminate as per the of Merino / Sunmica / Greenlam of approved shade and colour as per selection by Architects/Engineer incharge and inside surfaces finished 0.8mm off white decoliner laminate of approved make of approved shade and colour as per selection by Architects/Engineer incharge, edges finished with matching edge banding finishing wherever necessary, with all the necessary hardware such as powder coated drawer channels, SS auto-closing hinges, handles and wire managers etc. wherever necessary including cost of all labours, shifting, wastage, loading, unloading to the site complete. TV-02 : TV Unit @ Deluxe room living area - L -2.55 M X2.10M - 2Nos |
| 72 | Furnitures : Supply as per the drawing made using approved quality IS710 BWP plywood of approved makeoutside surfaces finished with 1mm SF laminate as per the of Merino / Sunmica / Greenlam of approved shade and colour as per selection by Architects/Engineer incharge and inside surfaces finished 0.8mm off white decoliner laminate of approved make of approved shade and colour as per selection by Architects/Engineer incharge, edges finished with matching edge banding finishing wherever necessary, with all the necessary hardware such as powder coated drawer channels, SS auto-closing hinges, handles and wire managers etc. wherever necessary including cost of all labours, shifting, wastage, loading, unloading to the site complete. TV-03 : TV Unit @ Deluxe room living area - L -2.80 M X2.10M - 4Nos |
| 73 | Furnitures : Supply as per the drawing made using approved quality IS710 BWP plywood of approved makeoutside surfaces finished with 1mm SF laminate as per the of Merino / Sunmica / Greenlam of approved shade and colour as per selection by Architects/Engineer incharge and inside surfaces finished 0.8mm off white decoliner laminate of approved make of approved shade and colour as per selection by Architects/Engineer incharge, edges finished with matching edge banding finishing wherever necessary, with all the necessary hardware such as powder coated drawer channels, SS auto-closing hinges, handles and wire managers etc. wherever necessary including cost of all labours, shifting, wastage, loading, unloading to the site complete. TV-04: TV Unit @ Suitroom living area - L - 4.30 M X2.10M - 2Nos |
| 74 | Furnitures : Supply as per the drawing made using approved quality IS710 BWP plywood of approved makeoutside surfaces finished with 1mm SF laminate as per the of Merino / Sunmica / Greenlam of approved shade and colour as per selection by Architects/Engineer incharge and inside surfaces finished 0.8mm off white decoliner laminate of approved make of approved shade and colour as per selection by Architects/Engineer incharge, edges finished with matching edge banding finishing wherever necessary, with all the necessary hardware such as powder coated drawer channels, SS auto-closing hinges, handles and wire managers etc. wherever necessary including cost of all labours, shifting, wastage, loading, unloading to the site complete. TV-05 : TV Unit @ Suitroom living area - L - 2.75 M X2.10M - 2Nos |
| 75 | Furnitures : Supply as per the drawing made using approved quality IS710 BWP plywood of approved makeoutside surfaces finished with 1mm SF laminate as per the of Merino / Sunmica / Greenlam of approved shade and colour as per selection by Architects/Engineer incharge and inside surfaces finished 0.8mm off white decoliner laminate of approved make of approved shade and colour as per selection by Architects/Engineer incharge, edges finished with matching edge banding finishing wherever necessary, with all the necessary hardware such as powder coated drawer channels, SS auto-closing hinges, handles and wire managers etc. wherever necessary including cost of all labours, shifting, wastage, loading, unloading to the site complete. TV-06 : TV Unit ( Digital games zone/ indoor play area ) -L- 3.2M X2.10 M - 1Nos |
| 76 | Furnitures : Supply as per the drawing made using approved quality IS710 BWP plywood of approved makeoutside surfaces finished with 1mm SF laminate as per the of Merino / Sunmica / Greenlam of approved shade and colour as per selection by Architects/Engineer incharge and inside surfaces finished 0.8mm off white decoliner laminate of approved make of approved shade and colour as per selection by Architects/Engineer incharge, edges finished with matching edge banding finishing wherever necessary, with all the necessary hardware such as powder coated drawer channels, SS auto-closing hinges, handles and wire managers etc. wherever necessary including cost of all labours, shifting, wastage, loading, unloading to the site complete. RAC -01 Racks Type -1@ shops |
| 77 | Furnitures : Supply as per the drawing made using approved quality IS710 BWP plywood of approved makeoutside surfaces finished with 1mm SF laminate as per the of Merino / Sunmica / Greenlam of approved shade and colour as per selection by Architects/Engineer incharge and inside surfaces finished 0.8mm off white decoliner laminate of approved make of approved shade and colour as per selection by Architects/Engineer incharge, edges finished with matching edge banding finishing wherever necessary, with all the necessary hardware such as powder coated drawer channels, SS auto-closing hinges, handles and wire managers etc. wherever necessary including cost of all labours, shifting, wastage, loading, unloading to the site complete. RAC -02 Racks Type - 2@ shops |
| 78 | Furnitures : Supply as per the drawing made using approved quality IS710 BWP plywood of approved makeoutside surfaces finished with 1mm SF laminate as per the of Merino / Sunmica / Greenlam of approved shade and colour as per selection by Architects/Engineer incharge and inside surfaces finished 0.8mm off white decoliner laminate of approved make of approved shade and colour as per selection by Architects/Engineer incharge, edges finished with matching edge banding finishing wherever necessary, with all the necessary hardware such as powder coated drawer channels, SS auto-closing hinges, handles and wire managers etc. wherever necessary including cost of all labours, shifting, wastage, loading, unloading to the site complete. RD-01 @ Receptionarea - reception desk |
| 79 | Furnitures : Supply as per the drawing made using approved quality IS710 BWP plywood of approved makeoutside surfaces finished with 1mm SF laminate as per the of Merino / Sunmica / Greenlam of approved shade and colour as per selection by Architects/Engineer incharge and inside surfaces finished 0.8mm off white decoliner laminate of approved make of approved shade and colour as per selection by Architects/Engineer incharge, edges finished with matching edge banding finishing wherever necessary, with all the necessary hardware such as powder coated drawer channels, SS auto-closing hinges, handles and wire managers etc. wherever necessary including cost of all labours, shifting, wastage, loading, unloading to the site complete. RD-02 @ shops- reception desk |
| 80 | Furnitures : Supply as per the drawing made using approved quality IS710 BWP plywood of approved makeoutside surfaces finished with 1mm SF laminate as per the of Merino / Sunmica / Greenlam of approved shade and colour as per selection by Architects/Engineer incharge and inside surfaces finished 0.8mm off white decoliner laminate of approved make of approved shade and colour as per selection by Architects/Engineer incharge, edges finished with matching edge banding finishing wherever necessary, with all the necessary hardware such as powder coated drawer channels, SS auto-closing hinges, handles and wire managers etc. wherever necessary including cost of all labours, shifting, wastage, loading, unloading to the site complete. CN-01 @ Bar counter |
| 81 | Part B-PROPOSED ELECTRICAL WORKS OF BDC BUILDING. |
| 82 | OPEN CONDUIT SYSTEM- Supplying heavy guage PVC Conduit pipe ….mm dia, …..mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy guage saddles at an interval of 700mm using NF screws. 19/20mm dia 2.5mm thick. (Refer KPWD SR 2023/24 Page 1 Sl. No. 1.1.1) |
| 83 | OPEN CONDUIT SYSTEM- Supplying heavy guage PVC Conduit pipe ….mm dia, …..mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy guage saddles at an interval of 700mm using NF screws. 25mm dia 2.5mm thick. (Refer KPWD SR 2023/24 Page 1 Sl. No. 1.1.2) |
| 84 | Supplying heavy guage PVC Conduit pipe ….mm dia, …..mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy guage saddles at an interval of 700mm using NF screws. 40mm dia 2.5mm thick. (Refer KPWD SR 2023/24Page 1 Sl. No. 1.1.4) |
| 85 | Supplying heavy guage PVC Conduit pipe ….mm dia, …..mm thick confirming to IS 2509 with suitable size bends, metal / PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18 SWG GI fish wire wherever necessary. 19/20mm dia 2mm thick. (Refer KPWD SR 2023/24 Page 1 Sl. No. 1.2.1) |
| 86 | Supplying heavy guage PVC Conduit pipe ….mm dia, …..mm thick confirming to IS 2509 with suitable size bends, metal / PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18 SWG GI fish wire wherever necessary. 25mm dia 2mm thick. (Refer KPWD SR 2023/24 Page 1 Sl. No. 1.2.2) |
| 87 | Supplying heavy guage PVC Conduit Pipe …..mm dia,…..mm thick with suitable size bends, metal junction boxes, adhesive paste etc., by groove cutting in the wall and fixing by using U or J hooks and cement plastering the wall surface and run with 18 SWG GI fish wire throughout the conduit wherever necessary. 19/20mm dia 2mm thick. (Refer KPWD SR 22023/24 Page 1 Sl. No. 1.3.1) |
| 88 | Supplying heavy guage PVC Conduit Pipe …..mm dia,…..mm thick with suitable size bends, metal junction boxes, adhesive paste etc., by groove cutting in the wall and fixing by using U or J hooks and cement plastering the wall surface and run with 18 SWG GI fish wire throughout the conduit wherever necessary. 25mm dia 2mm thick. (Refer KPWD SR 2023/24Page 1 Sl. No. 1.3.2) |
| 89 | Extra for groove cutting in brick wall / CC Floor to the suitable depth for concealing PVC / GI pipe and plastering finishing the wall upto wall surface complete -upto 50mm conduit CC floor. (Refer KPWD SR 2023/24Page 2 Sl. No. 1.7.2) |
| 90 | Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm .... etc. as required - 20 mm (Refer KPWD SR 2023/24Page 2 Sl. No. 1.8.1) |
| 91 | Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm .... etc. as required - 25 mm(Refer KPWD SR 2023/24 Page 2 Sl. No. 1.8.2) |
| 92 | Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm .... etc. as required - 32 mm(Refer KPWD SR 2023/24Page 2 Sl. No. 1.8.3) |
| 93 | Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm .... etc. as required - 38 mm(Refer KPWD SR 2023/24Page 2 Sl. No. 1.8.4) |
| 94 | Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm .... etc. as required - 50 mm(Refer KPWD SR 2023/24Page 2 Sl. No. 1.8.5) |
| 95 | Supplying PVC/GI flexible conduit pipe .... mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated complete-20 mm (Refer KPWD SR 2023/24Page 2 Sl. No. 1.9.1) |
| 96 | Supplying PVC/GI flexible conduit pipe .... mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated complete-25 mm(Refer KPWD SR 2023/24Page 2 Sl. No. 1.9.2) |
| 97 | Deep Junction Box-19/20mm deep junction box. (Refer KPWD SR 2023/24Page 2 Sl. No. 1.5.1) |
| 98 | Wooden Box - Supplying and flush mounting teak wooden box without front plank made of less than 12mm thick wood, after due groove cutting, finishing with necessary cement plastering complete - 1 to 2 Way. (Refer KPWD SR 2023/24Page 2 Sl. No. 1.6.6) |
| 99 | Wooden Box - Supplying and flush mounting teak wooden box without front plank made of less than 12mm thick wood, after due groove cutting, finishing with necessary cement plastering complete-3 to 4 Way. (Refer KPWD SR 2023/24Page 2 Sl. No. 1.6.7) |
| 100 | Wooden Box - Supplying and flush mounting teak wooden box without front plank made of less than 12mm thick wood, after due groove cutting, finishing with necessary cement plastering complete-5 to 6 Way. (Refer KPWD SR 2023/24Page 2 Sl. No. 1.6.8) |
| 101 | Supplying and fixing metal fan box with Round hook.(Refer KPWD SR 2023/24 Page 3 Sl. No. 1.12) |
| 102 | Point wiring using Copper wire with switch - Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm 2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.-Short point upto 3m from tapping point to out let via switch. (Refer KPWD SR 2023/24 Page 4 Sl. No. 2.1.1) |
| 103 | Point wiring using Copper wire with switch - Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm 2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.-Medium point above 3m upto 6m from tapping point to out let via switch. (Refer KPWD SR 2023/24Page4 Sl. No. 2.1.2) |
| 104 | Point wiring using Copper wire with switch - Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm 2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.-Long point above 6m upto 10m from tapping point to out let via switch. (Refer KPWD SR 2023/24 Page 4 Sl. No. 2.1.3) |
| 105 | Point wiring using Copper wire with switch - Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm 2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.- Two outlet in a row, above 3Mtr upto 6Mtr from tapping point to |
| 106 | Point wiring using Copper wire with switch - Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm 2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.-Three outlet in a row, above 6Mts upto 10Mtr from tapping point to |
| 107 | Wiring for lighting / power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990.-1.0 sqmm.(Refer KPWD SR 2023/24 Page 4 Sl. No. 2.3.1) |
| 108 | Wiring for lighting / power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990.-1.5 sqmm.(Refer KPWD SR 2023/24 Page 4 Sl. No. 2.3.2) |
| 109 | Wiring for lighting / power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990.-2.5 sq.mm(Refer KPWD SR 2023/24 Page 4 Sl. No. 2.3.3) |
| 110 | Wiring for lighting / power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990.-4 sqmm.(Refer KPWD SR 2023/24 Page 4 Sl. No. 2.3.4) |
| 111 | Wiring for lighting / power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990.-6 sqmm.(Refer KPWD SR 2023/24 Page 4 Sl. No. 2.3.5) |
| 112 | Wiring for lighting / power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990.-10 sqmm.(Refer KPWD SR 2023/24 Page 4 Sl. No. 2.3.6) |
| 113 | Wiring for lighting / power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990.-16 sqmm.(Refer KPWD SR 2023/24 Page 5 Sl. No. 2.3.7) |
| 114 | \"Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS:1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/- 10 %, Rated current As per IS:374/19,Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 6.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2year manufacturer Warranty. (BLDC fans)-48\" Sweep (1200 mm) Regular model.(Refer KPWD SR 2023/24 Page 29 Sl. No. 6.4.1) |
| 115 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.-1 - 3 way. (Refer KPWD SR 2023/24 Page7 Sl. No. 3.3.1) |
| 116 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.-3 way.(Refer KPWD SR 2022/23 Page 7 Sl. No. 3.3.2) |
| 117 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.-4-5way.(Refer KPWD SR 2022/23 Page 7 Sl. No. 3.3.3) |
| 118 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.-6 way.(Refer KPWD SR 2022/23 Page 7 Sl. No. 3.3.4) |
| 119 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.-8 way.(Refer KPWD SR 2022/23 Page 7 Sl. No. 3.3.5) |
| 120 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.-10 - 12way.(Refer KPWD SR 2022/23 Page 7 Sl. No. 3.3.6) |
| 121 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.-16 way.(Refer KPWD SR 2022/23 Page 7 Sl. No. 3.3.7) |
| 122 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.-18 way.(Refer KPWD SR 2022/23 Page 7 Sl. No. 3.3.8) |
| 123 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly mounted after due groove cutting in Brick/Stone/C.C. wall.-1 - 3 way. (Refer KPWD SR 2023/24 Page7 Sl. No. 3.4.1) |
| 124 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly mounted after due groove cutting in Brick/Stone/C.C. wall.-3 way.(Refer KPWD SR 2023/24Page 7 Sl. No. 3.4.2) |
| 125 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly mounted after due groove cutting in Brick/Stone/C.C. wall.-4-5way.(Refer KPWD SR 2023/24Page 7 Sl. No. 3.4.3) |
| 126 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly mounted after due groove cutting in Brick/Stone/C.C. wall.-6 way.(Refer KPWD SR 2023/24Page 7 Sl. No. 3.4.4) |
| 127 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly mounted after due groove cutting in Brick/Stone/C.C. wall.- 8 way.(Refer KPWD SR 2023/24Page 7 Sl. No. 3.4.5) |
| 128 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly mounted after due groove cutting in Brick/Stone/C.C. wall.- 10 - 12way.(Refer KPWD SR 2023/24 Page 7 Sl. No. 3.4.6) |
| 129 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly mounted after due groove cutting in Brick/Stone/C.C. wall. - 16 way.(Refer KPWD SR 2023/24 Page 7 Sl. No. 3.4.7) |
| 130 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly mounted after due groove cutting in Brick/Stone/C.C. wall. -18 way.(Refer KPWD SR 2023/24 Page 7 Sl. No. 3.4.8) |
| 131 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.-1 - 2 Module.(Refer KPWD SR2023/24 Page 7Sl. No. 3.5.1) |
| 132 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.- 3 Module.(Refer KPWD SR 2023/24 Page7 Sl. No. 3.5.2) |
| 133 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.- 4 Module.(Refer KPWD SR2023/24 Page7 Sl. No. 3.5.3) |
| 134 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.- 6 Module.(Refer KPWD SR 2023/24 Page 7 Sl. No. 3.5.4) |
| 135 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.-8 Module.(Refer KPWD SR2023/24 Page 7 Sl. No. 3.5.5) |
| 136 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.-10 - 12 Module.(Refer KPWD SR2023/24 Page 7 Sl. No. 3.5.6) |
| 137 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.-16 Module.(Refer KPWD SR2023/24 Page 7 Sl. No. 3.5.7) |
| 138 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.-18 Module.(Refer KPWD SR2023/24 Page 7 Sl. No. 3.5.8) |
| 139 | Supplying and fixing of Modular Switch / Socket / Stepped type electronic fan regulator / dimmer / telephone socket etc on existing modular Switch Plate. IS 3854 & IS 1293.-6A one way Switch.(Refer KPWD SR 2023/24 Page 8 Sl. No. 3.6.1) |
| 140 | Supplying and fixing of Modular Switch / Socket / Stepped type electronic fan regulator / dimmer / telephone socket etc on existing modular Switch Plate. IS 3854 & IS 1293. - 6A Two Way Switch.(Refer KPWD SR 2023/24 Page 8 Sl. No. 3.6.2) |
| 141 | Supplying and fixing of Modular Switch / Socket / Stepped type electronic fan regulator / dimmer / telephone socket etc on existing modular Switch Plate. IS 3854 & IS 1293. - 6A three way socket. (Refer KPWD SR 2023/24 Page 8 Sl. No. 3.6.3) |
| 142 | Supplying and fixing of Modular Switch / Socket / Stepped type electronic fan regulator / dimmer / telephone socket etc on existing modular Switch Plate. IS 3854 & IS 1293. - Stepped Fan Regulator. (Refer KPWD SR 2023/24 Page 8 Sl. No. 3.6.6) |
| 143 | Supplying and fixing of Modular Switch / Socket / Stepped type electronic fan regulator / dimmer / telephone socket etc on existing modular Switch Plate. IS 3854 & IS 1293. - 16A one way switch.(Refer KPWD SR 2023/24 Page 8 Sl. No. 3.6.7) |
| 144 | Supplying and fixing of Modular Switch / Socket / Stepped type electronic fan regulator / dimmer / telephone socket etc on existing modular Switch Plate. IS 3854 & IS 1293. - 6A Bell Push. (Refer KPWD SR 2023/24 Page 8 Sl. No. 3.6.8) |
| 145 | Supplying and fixing of Modular Switch / Socket / Stepped type electronic fan regulator / dimmer / telephone socket etc on existing modular Switch Plate. IS 3854 & IS 1293. - 32A DP Switch. (Refer KPWD SR 2023/24 Page 8 Sl. No. 3.6.9) |
| 146 | Supplying and fixing of Modular Switch / Socket / Stepped type electronic fan regulator / dimmer / telephone socket etc on existing modular Switch Plate. IS 3854 & IS 1293. - 6/16A Universal Socket. (Refer KPWD SR 2023/24 Page 8 Sl. No. 3.6.10) |
| 147 | Supplying and fixing of Modular Switch / Socket / Stepped type electronic fan regulator / dimmer / telephone socket etc on existing modular Switch Plate. IS 3854 & IS 1293. - TV/Telephone Socket. (Refer KPWD SR 2023/24 Page 8 Sl. No. 3.6.11) |
| 148 | Supplying and fixing of Modular Switch / Socket / Stepped type electronic fan regulator / dimmer / telephone socket etc on existing modular Switch Plate. IS 3854 & IS 1293. - RJ45/I.O Outlet Cat-6. (Refer KPWD SR 2023/24 Page 8 Sl. No. 3.6.12) |
| 149 | Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. - 6A Lamp Holder. (Refer KPWD SR 2023/24 Page 9 Sl. No. 3.14.6 ) |
| 150 | Supplying and fixing miniature circuit breaker on existing MCB distribution board using necessary fixing materials and \"C\" Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring confirming to IEC 60898.-6 - 32 Amps SP.(Refer KPWD SR 2023/24Page 16 Sl. No. 5.18.1) |
| 151 | Supplying and fixing miniature circuit breaker on existing MCB distribution board using necessary fixing materials and \"C\" Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring confirming to IEC 60898.-6 - 32 Amps DP.(Refer KPWD SR 2023/24Page 16Page 13 Sl. No. 5.18.4) |
| 152 | Supplying and fixing miniature circuit breaker on existing MCB distribution board using necessary fixing materials and \"C\" Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring confirming to IEC 60898.- 40 Amps DP.(Refer KPWD SR 2023/24Page 16Page 13 Sl. No. 5.18.5) |
| 153 | Supplying and fixing miniature circuit breaker on existing MCB distribution board using necessary fixing materials and \"C\" Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring confirming to IEC 60898. - 6- 32 Amps TPN.(Refer KPWD SR 2023/24Page 16 Page 13 Sl. No. 5.18.7) |
| 154 | Supplying and fixing miniature circuit breaker on existing MCB distribution board using necessary fixing materials and \"C\" Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring confirming to IEC 60898. - 40 Amps TPN.(Refer KPWD SR 2023/24Page 16Page 13 Sl. No. 5.18.8) |
| 155 | Supplying and fixing miniature circuit breaker on existing MCB distribution board using necessary fixing materials and \"C\" Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring confirming to IEC 60898. - 50- 63 Amps TPN.(Refer KPWD SR 2023/24Page 16Page 13 Sl. No. 5.18.9) |
| 156 | Supplying and fixing regular MCB distribution board on wall/ flush mounting using required clamps, bolts, nuts, etc., with provision for fixing suitable type capacity MCB\"s single phase / 3 phase/ single door with powder coated painting etc., complete. Made out of 14 SWG MS enclosure.-4 waySP & N.(Refer KPWD SR 2023/24Page 17 Sl. No. 5.19.1) |
| 157 | Supplying and fixing regular MCB distribution board on wall/ flush mounting using required clamps, bolts, nuts, etc., with provision for fixing suitable type capacity MCB\"s single phase / 3 phase/ single door with powder coated painting etc., complete. Made out of 14 SWG MS enclosure.- 6 waySP & N.(Refer KPWD SR 2023/24Page 17 Sl. No. 5.19.2) |
| 158 | Supplying and fixing regular MCB distribution board on wall/ flush mounting using required clamps, bolts, nuts, etc., with provision for fixing suitable type capacity MCB\"s single phase / 3 phase/ single door with powder coated painting etc., complete. Made out of 14 SWG MS enclosure.-8 way SP & N.(Refer KPWD SR 2023/24Page 17 Sl. No. 5.19.3) |
| 159 | Supplying and fixing regular MCB distribution board on wall/ flush mounting using required clamps, bolts, nuts, etc., with provision for fixing suitable type capacity MCB\"s single phase / 3 phase/ single door with powder coated painting etc., complete. Made out of 14 SWG MS enclosure.-12 waySP & N.(Refer KPWD SR 2023/24Page 17 Sl. No. 5.19.4) |
| 160 | Supplying and fixing regular MCB distribution board on wall/ flush mounting using required clamps, bolts, nuts, etc., with provision for fixing suitable type capacity MCB\"s single phase / 3 phase/ single door with powder coated painting etc., complete. Made out of 14 SWG MS enclosure.-16 waySP & N.(Refer KPWD SR 2023/24Page 17 Sl. No. 5.19.5) |
| 161 | Supplying and fixing regular MCB distribution board on wall/ flush mounting using required clamps, bolts, nuts, etc., with provision for fixing suitable type capacity MCB\"s single phase / 3 phase/ single door with powder coated painting etc., complete. Made out of 14 SWG MS enclosure.- 4 way TP & N.(Refer KPWD SR 2023/24Page 17 Sl. No. 5.19.11) |
| 162 | Supplying and fixing regular MCB distribution board on wall/ flush mounting using required clamps, bolts, nuts, etc., with provision for fixing suitable type capacity MCB\"s single phase / 3 phase/ single door with powder coated painting etc., complete. Made out of 14 SWG MS enclosure. - 6 way TP & N.(Refer KPWD SR 2023/24Page 17 Sl. No. 5.19.12) |
| 163 | Supplying and fixing regular MCB distribution board on wall/ flush mounting using required clamps, bolts, nuts, etc., with provision for fixing suitable type capacity MCB\"s single phase / 3 phase/ single door with powder coated painting etc., complete. Made out of 14 SWG MS enclosure. - 8 way TP & N.(Refer KPWD SR 2023/24Page 17 Sl. No. 5.19.13) |
| 164 | Supplying and fixing regular MCB distribution board on wall/ flush mounting using required clamps, bolts, nuts, etc., with provision for fixing suitable type capacity MCB\"s single phase / 3 phase/ single door with powder coated painting etc., complete. Made out of 14 SWG MS enclosure. - 12 way TP & N.(Refer KPWD SR 2023/24Page 17 Sl. No. 5.19.14) |
| 165 | Supplying and fixing regular MCB distribution board on wall/ flush mounting using required clamps, bolts, nuts, etc., with provision for fixing suitable type capacity MCB\"s single phase / 3 phase/ single door with powder coated painting etc., complete. Made out of 14 SWG MS enclosure. - 16 way TP & N.(Refer KPWD SR 2023/24Page 17 Sl. No. 5.19.15) |
| 166 | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board - 16A-25A 2 pole.(Refer KPWD SR 2023/24Page 17 Sl. No. 5.20.1) |
| 167 | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board- 32-40A 2 pole.(Refer KPWD SR 2023/24Page 17 Sl. No. 5.20.4) |
| 168 | Supplying, fixing and wiring 3 Phase Digital Ammeter / Voltmeter.(Refer KPWD SR 2021/22 Page 14 Sl. No. 5.29) |
| 169 | Supplying and fixing digital frequency meter with latest micro controller technology, ultra bright 4 digit LED display, from 30-500V AC and optional or relay output for high/low frequency and wiring complete.(Refer KPWD SR 2023/24 Page 18 Sl. No. 5.32) |
| 170 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, kVA, kWH, kVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy.(Refer KPWD SR 2023/24 Page 18 Sl. No. 5.33) |
| 171 | Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 A three phase 4 wire whole current class-1 Accuracy Energy Meter. (Refer KPWD SR 2023/24 Page 18 Sl. No. 5.35) |
| 172 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. (Refer KPWD SR 2023/24 Page 18Sl. No. 5.38) |
| 173 | Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete-100 A 4 x 30 x 6 mm Aluminium Strips (Refer KPWD SR 2023/24 Page 19 Sl. No. 5.40.1) |
| 174 | Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase / Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cut-out with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility.- 300 mm x 600 mm x 170 mm(Refer KPWD SR 2023/24 Page 20 Sl. No. 5.44.3) |
| 175 | Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase / Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cut-out with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility.- 600 mm x 600 mm x 170mm(Refer KPWD SR 2023/24 Page 20 Sl. No. 5.44.4) |
| 176 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism - 100A 25KA.(Refer KPWD SR 2023/24Page 16 Sl. No. 5.15.9.1) |
| 177 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism - 125A 25KA.(Refer KPWD SR 2023/24Page 16 Sl. No. 5.15.9.1) |
| 178 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism - 160A 25KA.(Refer KPWD SR 2023/24Page 16 Sl. No. 5.15.9.1) |
| 179 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism - 250A 25KA.(Refer KPWD SR 2023/24Page 16 Sl. No. 5.15.9.1) |
| 180 | Supplying and running of GI/copper strips for grounding connections using necessary fixing materials as required - GI Strip. -25 x 3mm. (Refer KPWD SR 2023/24 Page 53 Sl. No. 12.58.2) |
| 181 | Supplying and running of GI/copper strips for grounding connections using necessary fixing materials as required - Cu Strip. -25 x 3mm..(Refer KPWD SR 2023/24 Page 54 Sl. No. 12.58.7) |
| 182 | \"Supplying & Fixing Chemical earthling for grounding. Conduits, IC - cut-outs & other equipment’s backfill compound which is non corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm - Using 4ft copper bonded rod with backfill compound..(Refer KPWD SR 2023/24 Page 54 Sl. No. 12.60.1) |
| 183 | Supplying & fixing retrofit type-PL- LED Lamp ...... W LED linear source with CCT 6500 degree K, CRI> 70%. efficacy >80 lumen per W, life> 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF > 0.95, power loss should < 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to275 V. Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.- 8-9 watt..(Refer KPWD SR 2023/24Page 42 Sl. No. 11.2.1) |
| 184 | Supplying & fixing retrofit type-PL- LED Lamp ...... W LED linear source with CCT 6500 degree K, CRI> 70%. efficacy >80 lumen per W, life> 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF > 0.95, power loss should < 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to275 V. Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition 18-20 watt..(Refer KPWD SR 2023/24Page 42 Sl. No. 11.2.2) |
| 185 | Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI > 80. Power Input: 220-240V@ 50/60Hz & Power factor >0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4\" - 36/40w. (Refer KPWD SR 2023/24Page 42Sl. No. 11.3.3) |
| 186 | Supplying of recess mounting non integrated type LED down light...... W luminaire comprising of pressure decast/ extruded aluminium housing, with spring loaded false ceiling clA, LED of Power/COB with CCT 6500 degree K, CRI> 70%. efficacy >100 lumen per W, 120degree beam spread, life> 25000 burning hours and Compliance to IS10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LED\"s are driven by HF electronic driver integrated in a separate control gear assembly., with PF > 0.95, power loss should< 5% of lamp Wage, short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.- 15-18W.. (Refer KPWD SR 2023/24Page 43 Sl. No. 11.4.3) |
| 187 | Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI > 80. Power Input: 220-240V @50/60Hz & Power factor >0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition-15-18W.. (Refer KPWD SR 2023/24Page 43 Sl. No. 11.5.3) |
| 188 | Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076\" twin twisted PVC insulated wires, required Nos of round blocks and clA.- On wall/ ceiling / Rafter / Girders. (Refer KPWD SR 2023/24 Page 55 Sl. No. 13.7.1) |
| 189 | Fixing a ceiling /wall mounting fan of all capacities and all types, with necessary clA and \"S\" hook made out of 15mm dia MS rod, with 5 A. ceiling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired.(Refer KPWD SR 2023/24 Page 56 Sl. No. 13.11) |
| 190 | Supplying, erecting, testing & commissioning of OFF-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete.- 10 kVA Capacity. (Refer KPWD SR 2023/24 Page 37 Sl. No.9.3.5) |
| 191 | Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries.- 40 AH capacity (Refer KPWD SR 2023/24 Page 38 Sl. No.9.4.1) |
| 192 | Part B 1- INTERNAL ELECTRIFICATION / LT WORKS Non coded items |
| 193 | Supplying & fixing of2mm thick GI Perforated type cable Trays of Classic /Profab Engieers make. The cable tray shall be fixed to wall with suitable support angles at intervals of 1.5 meter/ or the fabricated 2 nos of clamps of 4 mm thickof size 5\"x10\".- 600mm wide x50mm height. |
| 194 | Supplying & fixing of2mm thick GI Perforated type cable Trays of Classic /Profab Engieers make. The cable tray shall be fixed to wall with suitable support angles at intervals of 1.5 meter/ or the fabricated 2 nos of clamps of 4 mm thickof size 5\"x10\".- 300mm wide x50mm height. |
| 195 | Supplying & fixing of2mm thick GI Perforated type cable Trays of Classic /Profab Engieers make. The cable tray shall be fixed to wall with suitable support angles at intervals of 1.5 meter/ or the fabricated 2 nos of clamps of 4 mm thickof size 5\"x10\". - 150mm wide x50mm height. |
| 196 | Supply, laying, testing and commissioning of the following approved make 1100V grade XLPE insulated Aluminum / Copper condutor, armoured PVC UG cable.The rate quoted shall be for laying the cable in existing trenches (indoor / out door) with all the accessories complete.- 3.5C x 185.0 sq.mm. A2XFY. |
| 197 | Supply, laying, testing and commissioning of the following approved make 1100V grade XLPE insulated Aluminum / Copper condutor, armoured PVC UG cable.The rate quoted shall be for laying the cable in existing trenches (indoor / out door) with all the accessories complete. -3.5C x 50.0 sq.mm A2XFY. |
| 198 | Supply, laying, testing and commissioning of the following approved make 1100V grade XLPE insulated Aluminum / Copper condutor, armoured PVC UG cable.The rate quoted shall be for laying the cable in existing trenches (indoor / out door) with all the accessories complete. -3.5C x 35.0 sq.mm A2XFY. |
| 199 | Supplying and providing cable end termination with crimping type Aluminum lugs, double compression brass cable gland,taping, crimping, gland and armour earthing as per the specification for the following cables. - 3.5C x 185.0 sq.mm. A2XFY. |
| 200 | Supplying and providing cable end termination with crimping type Aluminum lugs, double compression brass cable gland,taping, crimping, gland and armour earthing as per the specification for the following cables. - 3.5C x 50.0 sq.mm A2XFY. |
| 201 | Supplying and providing cable end termination with crimping type Aluminum lugs, double compression brass cable gland,taping, crimping, gland and armour earthing as per the specification for the following cables. - 3.5C x 35.0 sq.mm A2XFY. |
| 202 | Part C - PLUMBING & SANITARY SYSTEM |
| 203 | \"Providing and fixing white vitreous china pedestal type water closet(European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :(Refer KPWD SR 2023/24 Page 131 Sl. No.14.3)\"- W.C. pan with ISI marked white solid plastic seat and lid.(Refer KPWD SR 2023/24 Page 131 Sl. No.14.3.1) |
| 204 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:(Refer KPWD SR 2022/23 Page 132 Sl. No.14.7)-White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps.(Refer KPWD SR 2022/23 Page 132 Sl. No.14.7.1) |
| 205 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.(Refer KPWD SR 2023/24 Page 135Sl. No.14.22A) |
| 206 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing.(Refer KPWD SR 2023/24 Page 136 Sl. No.14.32)-Rectangular shape 1500x450 mm.(Refer KPWD SR 2023/24 Page 136 Sl. No.14.32.4) |
| 207 | Providing and fixing Flush valve soft touch made of Stainless steel with all concealed fitting arrangements & all necessary accessories complete - Class.(Refer KPWD SR 2023/24 Page 145 Sl. No.14.94-B) |
| 208 | Providing and fixing Wall spout with wall flange made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class.(Refer KPWD SR 2023/24 Page 140 Sl. No.14.57-B) |
| 209 | Providing and fixing Soap dish wired with 200mm width made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class.(Refer KPWD SR 2023/24 Page 145 Sl. No.14.91-A) |
| 210 | Providing and fixing Single lever wall mixer with L shaped Tubular bend set for overhead shower made of Stainless steel with all concealed fitting arrangements & all necessary accessories complete - Class(Refer KPWD SR 2023/24 Page 140 Sl. No.14.60) |
| 211 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :(Refer KPWD SR 2023/24 Page 133 Sl. No.14.10)- 510x1040 mm bowl depth 250 mm.(Refer KPWD SR 2023/24 Page 133 Sl. No.14.10.1.1) |
| 212 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(Refer KPWD SR 2023/24 Page 128 Sl. No.13.64).-75 mm nominal dia.(Refer KPWD SR 2023/24 Page 128 Sl. No.13.64.1) |
| 213 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(Refer KPWD SR 2023/24 Page 128 Sl. No.13.64).- 110 mm nominal dia.(Refer KPWD SR 2023/24 Page 128 Sl. No.13.64.22) |
| 214 | Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements & all necessary accessories complete.(Refer KPWD SR 2023/24 Page 128 Sl. No.13.63) |
| 215 | Providing and fixing on wall face unplasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter.(Refer KPWD SR 2023/24 Page 125 Sl. No.13.48) |
| 216 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. (Refer KPWD SR 2023/24 Page 122 Sl. No.13.32)- 15 mm nominal dia.(Refer KPWD SR 2023/24 Page 122 Sl. No.13.32.1) |
| 217 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. (Refer KPWD SR 2023/24 Page 122 Sl. No.13.32)- 20mm nominal dia.(Refer KPWD SR 2023/24 Page 122 Sl. No.13.32.2) |
| 218 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. (Refer KPWD SR 2023/24 Page 122 Sl. No.13.32)- 25 mm nominal dia.(Refer KPWD SR 2023/24 Page 122 Sl. No.13.32.3) |
| 219 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. (Refer KPWD SR 2023/24 Page 122 Sl. No.13.32)-32 mm nominal dia.(Refer KPWD SR 2023/24 Page 122 Sl. No.13.32.4) |
| 220 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall. (Refer KPWD SR 2023/24 Page 122 Sl. No.13.31).- 15 mm nominal dia.(Refer KPWD SR 2023/24 Page 122 Sl. No.13.31.1) |
| 221 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall. (Refer KPWD SR 2023/24 Page 122 Sl. No.13.31).- 20mm nominal dia.(Refer KPWD SR 2023/24 Page 122 Sl. No.13.31.2) |
| 222 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall. (Refer KPWD SR 2023/24 Page 122 Sl. No.13.31). - 25 mm nominal dia.(Refer KPWD SR 2023/24 Page 122 Sl. No.13.31.3) |
| 223 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall. (Refer KPWD SR 2023/24 Page 122 Sl. No.13.31). - 32 mm nominal dia.(Refer KPWD SR 2023/24 Page 122 Sl. No.13.31.4) |
| 224 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall. (Refer KPWD SR 2023/24 Page 122 Sl. No.13.31). - 40 mm nominal dia.(Refer KPWD SR 2023/24 Page 122 Sl. No.13.31.1) |
| 225 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall. (Refer KPWD SR 2023/24 Page 122 Sl. No.13.31). - 50mm nominal dia.(Refer KPWD SR 2023/24 Page 122 Sl. No.13.31.2) |
| 226 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. (Refer KPWD SR 2023/24 Page 125Sl. No.13.50).- 40 mm nominal dia.(Refer KPWD SR 2023/24 Page 125 Sl. No.13.50.5) |
| 227 | Providing and fixing brass bib cock of approved quality :(Refer KPWD SR 2023/24Page 117 Sl. No.13.2)- 15 mm nominal bore.(Refer KPWD SR 2023/24 Page 117 Sl. No.13.2.1) |
| 228 | Providing and fixing brass bib cock of approved quality :(Refer KPWD SR 2023/24Page 117 Sl. No.13.2) - 20 mm nominal bore.(Refer KPWD SR 2023/24 Page 117 Sl. No.13.2.2) |
| 229 | Providing and fixing brass stop cock of approved quality :(Refer KPWD SR 2023/24 Page 117 Sl. No.13.3) - 15 mm nominal bore.(Refer KPWD SR 2023/24 Page 117 Sl. No.13.3.1) |
| 230 | Providing and fixing brass stop cock of approved quality :(Refer KPWD SR 2023/24 Page 117 Sl. No.13.3) - 20 mm nominal bore.(Refer KPWD SR 2023/24 Page 117 Sl. No.13.3.2) |
| 231 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end):(Refer KPWD SR 2023/24 Page 117 Sl. No.13.4)- 25 mm nominal bore.(Refer KPWD SR 2023/24 Page 117 Sl. No.13.4.1) |
| 232 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end):(Refer KPWD SR 2023/24 Page 117 Sl. No.13.4)- 32 mm nominal bore.(Refer KPWD SR 2023/24 Page 117 Sl. No.13.4.2) |
| 233 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end):(Refer KPWD SR 2023/24 Page 117 Sl. No.13.4)- 40 mm nominal bore.(Refer KPWD SR 2023/24 Page 117 Sl. No.13.4.3) |
| 234 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end):(Refer KPWD SR 2023/24 Page 117 Sl. No.13.4)-50 mm nominal bore.(Refer KPWD SR 2023/24 Page 117 Sl. No.13.4.4) |
| 235 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 g.(Refer KPWD SR 2023/24 Page 119 Sl. No.13.14) |
| 236 | Part D- HVAC |
| 237 | Supplying and Installation of VRF Top Discharge AC, CDU 16HP, Cooling Only, Outdoor Units, Cooling capacity 45000 W, External Dimensions 180 x 121 x 78, total weight more than 281 kgs, compressor motor output 5500 W x 2 Nos, fan motor output 1000 W, air volume 12600 cu.m/hr, sound pressure level 61 dBa, Max. External static pressure 40Pa, ISEER rating upto 9.0, remote diagnostic technology, Expanded ambient operational range of -5°C to 52°C, with all cost, hardware, conveyance labour for all items of work, HOM with all lead and lift, loading and unloading, transportation charges and all other incidental charges etc., complete as per specification and directions of the Engineer-in-charge of the work. |
| 238 | Supplying and Installation of VRF Top Discharge AC, CDU 18HP, Cooling Only, Outdoor Units, Cooling capacity 50400 W, External Dimensions 180 x 121 x 78, total weight more than 281 kgs, compressor motor output 6600 W x 2 Nos, fan motor output 1000 W, air volume 12600 cu.m/hr, sound pressure level 62 dBa, Max. External static pressure 40Pa, ISEER rating upto 9.0, remote diagnostic technology, Expanded ambient operational range of -5°C to 52°C, with all cost, hardware, conveyance labour for all items of work, HOM with all lead and lift, loading and unloading, transportation charges and all other incidental charges etc., complete as per specification and directions of the Engineer-in-charge of the work. |
| 239 | Supplying and Installation of Indoor unit for the Bar & Restaurant (2422 Sqft) area of VRF FCU 10.0HP High static concealed duct - 8TR, Supply of Simple wired remote controller for 8TR, Coolig capacity 28.0 kW, running current 50 Hz 3.77 A, power consumption 50 Hz 0.790, dimensions 448 x 1400 x 900 mm , standard air flow upto 4800 cu.m / hr, finned tube heat exchanger, polyurethene foam, heat exchanger, sound pressure level ,ax 46 dBA, 7 step external static pressure, with all cost, hardware, conveyance labour for all items of work, HOM with all lead and lift, loading and unloading, transportation charges and all other incidental charges etc., complete as per specification and directions of the Engineer-in-charge of the work. |
| 240 | Supplying and Installation of Indoor unit for the Office (87 Sqft): Supply of VRF 1.25HP/1TR 4-way Cassette, Supply of Panel for VRF 4-way cassette, Supply of Wireless Remote For 4 way Cassette, Cooling capacity 3.6 kW, running current 50 Hz 0.23 A, power consumption 50 Hz 0.021 Kw, dimensions 256 x 840 x 840 mm , standard air flow upto 800 cu.m / hr, finned tube heat exchanger, finned tube heat exchanger, sound pressure level max 30 dBA, Non flammable insulation, with all cost, hardware, conveyance labour for all items of work, HOM with all lead and lift, loading and unloading, transportation charges and all other incidental charges etc., complete as per specification and directions of the Engineer-in-charge of the work. |
| 241 | Supplying and Installation of Indoor unit for the Reception & Lobby (420 Sqft): Supply of VRF 2.00HP/1.5TR 4-way Cassette,Supply of Panel for VRF 4-way cassette, Supply of Wireless Remote For 4 way Cassette, Cooling capacity 5.6 kW, running current 50 Hz 0.29 A, power consumption 50 Hz 0.026 Kw, dimensions 256 x 840 x 840 mm , standard air flow upto 1050 cu.m / hr, finned tube heat exchanger, finned tube heat exchanger, sound pressure level max 32 dBA, Non flammable insulation, with all cost, hardware, conveyance labour for all items of work, HOM with all lead and lift, loading and unloading, transportation charges and all other incidental charges etc., complete as per specification and directions of the Engineer-in-charge of the work. |
| 242 | Supplying and Installtion of Indoor unit for the Reception & Lobby (420 Sqft): Supply of VRF 2.00HP/1.5TR 4-way Cassette,Supply of Panel for VRF 4-way cassette, Supply of Wireless Remote For 4 way Cassette, Cooling capacity 5.6 kW, running current 50 Hz 0.29 A, power consumption 50 Hz 0.026 Kw, dimensions 256 x 840 x 840 mm , standard air flow upto 1050 cu.m / hr, finned tube heat exchanger, finned tube heat exchanger, sound pressure level max 32 dBA, Non flammable insutaltion, with all cost, hardware, conveyance labour for all items of work, HOM with all lead and lift, loading and unloading, transportation charges and all other incidental charges etc., complete as per specification and directions of the Engineer-in-charge of the work. |
| 243 | Supplying and Installtion of Indoor unit for the Indoor Game area (742 Sqft): Supply of VRF 6.0 HP High static concealed duct - 4.5TR, Supply of Simple wired remote controller for 4.5TR, Coolig capacity 16.0 kW, running current 50 Hz 2.48 A, power consumption 50 Hz 0.400, dimensions 298 x 1400 x 750 mm , standard air flow upto 2760 cu.m / hr, finned tube heat exchanger, polyurethene foam, heat exchanger, sound pressure level ,ax 46 dBA, 7 step external static pressure, with all cost, hardware, conveyance labour for all items of work, HOM with all lead and lift, loading and unloading, transportation charges and all other incidental charges etc., complete as per specification and directions of the Engineer-in-charge of the work. |
| 244 | Supplying and Installtion of Indoor unit for the Bedroom 1 (349 Sqft): Supply of VRF FCU 2.00HP Concealed duct - 1.5TR, Wireless Remote (Stand alone for all) for FCU, Cooling capacity 5.6 kW, running current 50 Hz 0.70 A, power consumption 50 Hz 0.110 Kw, dimensions 275 x 1000 x 750 mm , standard air flow upto 1320 cu.m / hr, finned tube heat exchanger, polyurethene foam, heat exchanger, sound pressure level 36 dBA, 30 Pa static pressure, with all cost, hardware, conveyance labour for all items of work, HOM with all lead and lift, loading and unloading, transportation charges and all other incidental charges etc., complete as per specification and directions of the Engineer-in-charge of the work. |
| 245 | Shop-01 (335 Sqft): Supply of 2TR 3* inverter Hiwall unit (Non VRF). |
| 246 | Shop-02 (159 Sqft): Supply of 1.5TR 3* inverter Hiwall unit (Non VRF) |
| 247 | Shop-03 (155 Sqft): Supply of 1.5TR 3* inverter Hiwall unit (Non VRF). |
| 248 | Supplying and Installtion of Indoor unit for the AV Room (539 Sqft): Supply ofVRF 2.50HP 4-way Cassette - 2TR, Supply of Panel for VRF 4-way cassette, Supply of Wireless Remote For 4 way Cassette, Cooling capacity 7.1 kW, running current 50 Hz 0.38 A, power consumption 50 Hz 0.036 Kw, dimensions 256 x 840 x 840 mm , standard air flow upto 1290 cu.m / hr, finned tube heat exchanger, finned tube heat exchanger, sound pressure level max 35 dBA, Non flammable insutaltion, with all cost, hardware, conveyance labour for all items of work, HOM with all lead and lift, loading and unloading, transportation charges and all other incidental charges etc., complete as per specification and directions of the Engineer-in-charge of the work. |
| 249 | Supplying and Installtion of Indoor unit for the Bedroom 1 (349 Sqft): Supply of VRF FCU 2.00HP Concealed duct - 1.5TR, Wireless Remote (Stand alone for all) for FCU, Cooling capacity 5.6 kW, running current 50 Hz 0.70 A, power consumption 50 Hz 0.110 Kw, dimensions 275 x 1000 x 750 mm , standard air flow upto 1320 cu.m / hr, finned tube heat exchanger, polyurethene foam, heat exchanger, sound pressure level 36 dBA, 30 Pa static pressure, with all cost, hardware, conveyance labour for all items of work, HOM with all lead and lift, loading and unloading, transportation charges and all other incidental charges etc., complete as per specification and directions of the Engineer-in-charge of the work. |
| 250 | Supplying and Installtion of Indoor unit for the Bedroom 2 (702 Sqft): Supply of VRF FCU 2.5HP Concealed duct - 2TR, Supply of VRF FCU 2.00HP Concealed duct - 1.5TR, Wireless Remote (Stand alone for all) for FCU, Cooling capacity 7.1 kW, running current 50 Hz 0.92 A, power consumption 50 Hz 0.140, dimensions 298 x 1400 x 750 mm , standard air flow upto 1200 cu.m / hr, finned tube heat exchanger, polyurethene foam, heat exchanger, sound pressure level ,ax 38 dBA, 7 step external static pressure, with all cost, hardware, conveyance labour for all items of work, HOM with all lead and lift, loading and unloading, transportation charges and all other incidental charges etc., complete as per specification and directions of the Engineer-in-charge of the work. |
| 251 | Supplying and Installtion of Indoor unit for the Bedroom 3 (697 Sqft): Supply of VRF FCU 2.5HP Concealed duct - 2TR, Supply of VRF FCU 2.00HP Concealed duct - 1.5TR, Wireless Remote (Stand alone for all) for FCU, Cooling capacity 7.1 kW, running current 50 Hz 0.92 A, power consumption 50 Hz 0.140, dimensions 298 x 1400 x 750 mm , standard air flow upto 1200 cu.m / hr, finned tube heat exchanger, polyurethene foam, heat exchanger, sound pressure level ,ax 38 dBA, 7 step external static pressure, with all cost, hardware, conveyance labour for all items of work, HOM with all lead and lift, loading and unloading, transportation charges and all other incidental charges etc., complete as per specification and directions of the Engineer-in-charge of the work. |
| 252 | Supplying and Installation of Indoor unit for the Bedroom 4, 5, 6 (303 Sqft each): Supply of VRF FCU 1.25HP Concealed duct - 1TR, Wireless Remote (Stand alone for all) for FCU, Cooling capacity 3.6 kW, running current 50 Hz 0.38 A, power consumption 50 Hz 0.060, dimensions 275 x 700 x 750 mm , standard air flow upto 630 cu.m / hr, finned tube heat exchanger, polyurethene foam, heat exchanger, sound pressure level max 33 dBA, 30 Pa static pressure, with all cost, hardware, conveyance labour for all items of work, HOM with all lead and lift, loading and unloading, transportation charges and all other incidental charges etc., complete as per specification and directions of the Engineer-in-charge of the work. |
| 253 | Supplying and fixing the tubular insulation of hard/soft-drawn copper pipes for the refrigerant piping and interconnecting the liquid and suction lines between the indoor and outdoor units with soldered, brazed socket fittings of approved make. Pipes shall be insulated with 19 mm/13 mm thick closed cell nitrile rubber insulation with all costs, hardware, and conveyance labor for all items of work, HOM with all lead and lift, loading and unloading, transportation charges, and all other incidental charges, etc., complete as per specification and directions of the engineer-in-charge of the work-41.3mm (1 ⅝\") dia with 19 mm thick tubular insulation |
| 254 | Supplying and fixing the tubular insulation of hard/soft-drawn copper pipes for the refrigerant piping and interconnecting the liquid and suction lines between the indoor and outdoor units with soldered, brazed socket fittings of approved make. Pipes shall be insulated with 19 mm/13 mm thick closed cell nitrile rubber insulation with all costs, hardware, and conveyance labor for all items of work, HOM with all lead and lift, loading and unloading, transportation charges, and all other incidental charges, etc., complete as per specification and directions of the engineer-in-charge of the work- 34.9mm (1 ⅜\") dia with 19 mm thick tubular insulation |
| 255 | Supplying and fixing the tubular insulation of hard/soft-drawn copper pipes for the refrigerant piping and interconnecting the liquid and suction lines between the indoor and outdoor units with soldered, brazed socket fittings of approved make. Pipes shall be insulated with 19 mm/13 mm thick closed cell nitrile rubber insulation with all costs, hardware, and conveyance labor for all items of work, HOM with all lead and lift, loading and unloading, transportation charges, and all other incidental charges, etc., complete as per specification and directions of the engineer-in-charge of the work-28.6mm (1⅛\") dia with 19 mm thick tubular insulation |
| 256 | Supplying and fixing the tubular insulation of hard/soft-drawn copper pipes for the refrigerant piping and interconnecting the liquid and suction lines between the indoor and outdoor units with soldered, brazed socket fittings of approved make. Pipes shall be insulated with 19 mm/13 mm thick closed cell nitrile rubber insulation with all costs, hardware, and conveyance labor for all items of work, HOM with all lead and lift, loading and unloading, transportation charges, and all other incidental charges, etc., complete as per specification and directions of the engineer-in-charge of the work-22.2mm (⅞\") dia with 19mm thick tubular insulation |
| 257 | Supplying and fixing the tubular insulation of hard/soft-drawn copper pipes for the refrigerant piping and interconnecting the liquid and suction lines between the indoor and outdoor units with soldered, brazed socket fittings of approved make. Pipes shall be insulated with 19 mm/13 mm thick closed cell nitrile rubber insulation with all costs, hardware, and conveyance labor for all items of work, HOM with all lead and lift, loading and unloading, transportation charges, and all other incidental charges, etc., complete as per specification and directions of the engineer-in-charge of the work-19.1mm (¾\") dia with 13 mm thick tubular insulation (soft) |
| 258 | Supplying and fixing the tubular insulation of hard/soft-drawn copper pipes for the refrigerant piping and interconnecting the liquid and suction lines between the indoor and outdoor units with soldered, brazed socket fittings of approved make. Pipes shall be insulated with 19 mm/13 mm thick closed cell nitrile rubber insulation with all costs, hardware, and conveyance labor for all items of work, HOM with all lead and lift, loading and unloading, transportation charges, and all other incidental charges, etc., complete as per specification and directions of the engineer-in-charge of the work-15.9mm (⅝\") diawith 13 mm thick tubular insulation (Soft) |
| 259 | Supplying and fixing the tubular insulation of hard/soft-drawn copper pipes for the refrigerant piping and interconnecting the liquid and suction lines between the indoor and outdoor units with soldered, brazed socket fittings of approved make. Pipes shall be insulated with 19 mm/13 mm thick closed cell nitrile rubber insulation with all costs, hardware, and conveyance labor for all items of work, HOM with all lead and lift, loading and unloading, transportation charges, and all other incidental charges, etc., complete as per specification and directions of the engineer-in-charge of the work-12.7mm (½\") dia with 9 mm thick tubular insulation (Soft) |
| 260 | Supplying and fixing the tubular insulation of hard/soft-drawn copper pipes for the refrigerant piping and interconnecting the liquid and suction lines between the indoor and outdoor units with soldered, brazed socket fittings of approved make. Pipes shall be insulated with 19 mm/13 mm thick closed cell nitrile rubber insulation with all costs, hardware, and conveyance labor for all items of work, HOM with all lead and lift, loading and unloading, transportation charges, and all other incidental charges, etc., complete as per specification and directions of the engineer-in-charge of the work-9.5mm (⅜\") dia with 9 mm thick tubular insulation (Soft) |
| 261 | Supplying and fixing the tubular insulation of hard/soft-drawn copper pipes for the refrigerant piping and interconnecting the liquid and suction lines between the indoor and outdoor units with soldered, brazed socket fittings of approved make. Pipes shall be insulated with 19 mm/13 mm thick closed cell nitrile rubber insulation with all costs, hardware, and conveyance labor for all items of work, HOM with all lead and lift, loading and unloading, transportation charges, and all other incidental charges, etc., complete as per specification and directions of the engineer-in-charge of the work- 6.35mm (¼\") dia with 9 mm thick tubular insulation (Soft) |
| 262 | Supplying and providing additional refrigerant gas charging for the air conditioning system. with all costs, hardware, conveyance labor for all items of work, HOM with all lead and lift, loading and unloading, transportation charges, and all other incidental charges, etc., complete as per specification and directions of the engineer-in-charge of the work. |
| 263 | \"Supplying and fixing the Refnet joints Y joints for air conditioning systems, ensuring proper refrigerant flow, system efficiency, and long-term performance of copper pipes with high-quality insulation like open-cell nitrile rubber of 140-180 kg/m³ for the pipes with all required fittings of approved make with all costs, hardware, and conveyance labor for all items of work, HOM with all lead and lift, loading and unloading, transportation charges, and all other incidental charges, etc., complete as per specification and directions of the engineer-in-charge of the work. |
| 264 | Supplying and fixing the Refnet joints T joints for air conditioning systems, ensuring proper refrigerant flow, system efficiency, and long-term performance of copper pipes with high-quality insulation like open-cell nitrile rubber of 140-180 kg/m³ for the pipes with all required fittings of approved make with all costs, hardware, conveyance labor for all items of work, HOM with all lead and lift, loading and unloading, transportation charges, and all other incidental charges, etc., complete as per specification and directions of the engineer-in-charge of the work. |
| 265 | Supply and fixing of flexible canvas connection piece between unit and duct with all the necessary fittings with all costs, hardware, conveyance labor for all items of work, HOM with all lead and lift, loading and unloading, transportation charges, and all other incidental charges, etc., complete as per specification and directions of the engineer-in-charge of the work. |
| 266 | Supply and fixing of the GI support/trays for erecting copper pipes with all the necessary fittings for approved make with all costs, hardware, conveyance labor for all items of work, HOM with all lead and lift, loading and unloading, transportation charges, and all other incidental charges, etc., complete as per specification and directions of the engineer-in-charge of the work. |
| 267 | Supply, installation, testing, and commissioning of CNC machine-made GSS ducting with flanges and neoprene gaskets and factory-made supports. Supplying and installation of CNC machine-made GSS ducting with flanges, neoprene gaskets, and factory-made supports with all the necessary fittings of approved make with all costs, hardware, conveyance labor for all items of work, HOM with all lead and lift, loading and unloading, transportation charges, and all other incidental charges, etc., complete as per specification and directions of the engineer-in-charge of the work.- 24G |
| 268 | Supply, installation, testing, and commissioning of CNC machine-made GSS ducting with flanges and neoprene gaskets and factory-made supports. Supplying and installation of CNC machine-made GSS ducting with flanges, neoprene gaskets, and factory-made supports with all the necessary fittings of approved make with all costs, hardware, conveyance labor for all items of work, HOM with all lead and lift, loading and unloading, transportation charges, and all other incidental charges, etc., complete as per specification and directions of the engineer-in-charge of the work. - 22G |
| 269 | \"Supplying and installation of 10 mm thick acoustic insulation of the ducting using open cell nitrile rubber of 140-180 kg/m³ with all the necessary fittings of approved make with all costs, hardware, conveyance labor for all items of work, HOM with all lead and lift, loading and unloading, transportation charges, and all other incidental charges, etc., complete as per specification and directions of the engineer-in-charge of the work. |
| 270 | \"Supplying and installation of thermal insulation for ducting internally with class 13 mm thick nitrile rubber with all the necessary fittings of approved make with all costs, hardware, conveyance labor for all items of work, HOM with all lead and lift, loading and unloading, transportation charges, and all other incidental charges, etc., complete as per specification and directions of the engineer-in-charge of the work. |
| 271 | Supplying and installation of G.I. collar dampers with opposed blades of approved make with all costs, hardware, conveyance labor for all items of work, HOM with all lead and lift, loading and unloading, transportation charges, and all other incidental charges, etc., complete as per specification and directions of the engineer-in-charge of the work. - Rate per sq.mt of face area (min measurement of 0.1 sq mt) |
| 272 | Supplying and installation of air terminals of approved make with all costs, hardware, conveyance labor for all items of work, HOM with all lead and lift, loading and unloading, transportation charges, and all other incidental charges, etc., complete as per specification and directions of the engineer-in-charge of the work. - Aluminium powder coated continuous SA/RA grilles with 0/15 deg. Deflection |
| 273 | Supplying and installation of electrical cabling works of approved make with all costs, hardware, conveyance labor for all items of work, HOM with all lead and lift, loading and unloading, transportation charges, and all other incidental charges, etc., complete as per specification and directions of the engineer-in-charge of the work. -3C X 1.5Sqmm flexible cable - power cable & signal cable |
| 274 | Supplying and fixing of the 32/25 mm heavy-duty PVC drain pipes with required elbows/tee/bend/saddles, etc., with all costs, hardware, and conveyance labor for all items of work, HOM with all lead and lift, loading and unloading, transportation charges, and all other incidental charges, etc., complete as per specification and directions of the engineer-in-charge of the work. |
| 275 | 16A plug top |
| 276 | Supplying and fixing of the copper piping with nitrile rubber insulation for the high wall units with all the necessary fittings of approved make with all costs, hardware, conveyance labor for all items of work, HOM with all lead and lift, loading and unloading, transportation charges, and all other incidental charges, etc., complete as per specification and directions of the engineer-in-charge of the work. |
| 277 | Supply of 5KVA electronic voltage stabilizer for 2TR Hiwallunits. .Working range of 170 V -270 VVAC,, 50Hz,z and capacity of 15 amps with allcostst, hardware, conveyancelaborr for all items of work, HOM with all lead and lift, loading and unloading, transportation charges and all other incidental charges, etc., complete as per specification and directions of the engineer-in-charge of the work. |
| 278 | \"Supply of 4KVA electronic voltage stabilizer for 1.5 TR Hi wall units. .Working range of 170 V -270 VVAC,, 50Hz,z and a capacity of 12 amps with all costs, hardware, conveyance labor for all items of work, HOM with all lead and lift, loading and unloading, transportation charges,and all other incidental charges etc., complete as per specification and directions of the engineer-in-charge of the work. |
| 279 | Stand for Hi wall units |
| 280 | \"Supplying and installation of cabinet/circular-type duct inline fan unit of approved make with all costs, hardware, and conveyance labor for all items of work, HOM with all lead and lift, loading and unloading, transportation charges, and all other incidental charges, etc., complete as per specification and directions of the engineer-in-charge of the work. 200CFM - 20 mm static |
| 281 | Supplying and installation of 3C X 2.5 Sqmm power cable of approved make with all costs, hardware, conveyance labor for all items of work, HOM with all lead and lift, loading and unloading, transportation charges, and all other incidental charges, etc., complete as per specification and directions of the Engineer-in-charge of the work. |
| 282 | Supplying and installation of GI duct connection between PVC pipe and unit mouth & discharge side - 24G of approved make with all costs, hardware, and conveyance labor for all items of work, HOM with all lead and lift, loading and unloading, transportation charges, and all other incidental charges, etc., complete as per specification and directions of the engineer-in-charge of the work. |
| 283 | Supplying and installation of cowl piece with bird mesh in discharge with all costs, hardware, conveyance labor for all items of work, HOM with all lead and lift, loading and unloading, transportation charges, and all other incidental charges, etc., complete as per specification and directions of the engineer-in-charge of the work. |
| 284 | Supply, installation, testing, and commissioning of uninsulated aluminum flexible duct with worm clips and supports as follows. with all costs, hardware, conveyance labor for all items of work, HOM with all lead and lift, loading and unloading, transportation charges, and all other incidental charges, etc., complete as per specification and directions of the engineer-in-charge of the work. -100 mm dia |
| 285 | Supply, installation, testing, and commissioning of round collar dampers of approved make with all costs, hardware, and conveyance labor for all items of work; HOM with all lead and lift, loading and unloading, transportation charges, and all other incidental charges, etc., complete as per specification and directions of the engineer-in-charge of the work. -100 mm dia |
| 286 | Supply, installation, testing, and commissioning of aluminum powder-coated disk valves of approved make with all costs, hardware, conveyance labor for all items of work, HOM with all lead and lift, loading and unloading, transportation charges, and all other incidental charges, etc., complete as per specification and directions of the engineer-in-charge of the work.- 100 mm dia |
| 287 | Logistics and labour transportation during course of execution |
| 288 | Lifting, Shifting, of Indoor/outdoor units (manual shifting) |
| 289 | Lifting, Shifting, Transportation towards GI ducts and its anciillaries from Factory - Ex Bangalore |
| 290 | Part E - CCTV AND LAN WORK |
| 291 | Supplying & fixing Cat 6 Untwisted Pair Cable Engieers make with all cost, hardware etccomplete as per specification and directions of the Engineer-in-charge of the work. |
| 292 | Supplying & fixing Information Out Let Cat 6Engieers make with all cost, hardware etccomplete as per specification and directions of the Engineer-in-charge of the work. |
| 293 | Supplying & fixing Single Face Plate Engieers make with all cost, hardware etccomplete as per specification and directions of the Engineer-in-charge of the work. |
| 294 | Supplying & fixing Surface Mount Box Engieers make with all cost, hardware etccomplete as per specification and directions of the Engineer-in-charge of the work. |
| 295 | Supplying & fixing 24 Port Cat 6 Rack Mount Jack Panel with Key StoneEngieers make with all cost, hardware etccomplete as per specification and directions of the Engineer-in-charge of the work. |
| 296 | Supplying & fixing1 Meter UTP Patch Cord Cat 6 Engieers make with all cost, hardware etccomplete as per specification and directions of the Engineer-in-charge of the work. |
| 297 | Supplying & fixing2 Meter UTP Patch Cord Cat 6Engieers make with all cost, hardware etccomplete as per specification and directions of the Engineer-in-charge of the work. |
| 298 | Supplying & fixing Network Rack 9U 500 Depth with Glass Door, 6 Socket PDU ,. Tray/ FAN/ Mounting Kit / Cable Manager - CCTV And LANwith all cost, hardware, conveyance labour for all items of work, HOM with all lead and lift, loading and unloading, transportation charges and all other incidental charges etc., complete as per specification and directions of the Engineer-in-charge of the work. |
| 299 | Supplying & fixing Network Rack 6U 400 Depth with Glass Door, 6 Socket PDU ,. Tray/ FAN/ Mounting Kit / Cable Manager Telephone with all cost, hardware, conveyance labour for all items of work, HOM with all lead and lift, loading and unloading, transportation charges and all other incidental charges etc., complete as per specification and directions of the Engineer-in-charge of the work. |
| 300 | Supplying & fixing Network Switch 24 Port Gigabit with OFC UplinkNetwork SwitchEngieers make with all cost, hardware etccomplete as per specification and directions of the Engineer-in-charge of the work. |
| 301 | Supplying & fixing Network POE Switch Gigabit Engieers make with all cost, hardware etccomplete as per specification and directions of the Engineer-in-charge of the work. |
| 302 | Supplying & fixing Single Mode OFC ModuleEngieers make with all cost, hardware etccomplete as per specification and directions of the Engineer-in-charge of the work. |
| 303 | Supplying & fixingCC Camera Mounting Box 5X5 PVCEngieers make with all cost, hardware etccomplete as per specification and directions of the Engineer-in-charge of the work. |
| 304 | Supplying & fixing PVC Conduit with Fittings and Labour with all cost, hardware, conveyance labour for all items of work, HOM with all lead and lift, loading and unloading, transportation charges and all other incidental charges etc., complete as per specification and directions of the Engineer-in-charge of the work. |
| 305 | Supplying & fixing IO Terminatioin Charges Engieers make with all cost, hardware etccomplete as per specification and directions of the Engineer-in-charge of the work. |
| 306 | Supplying & fixing Jack Panel Termination Chargeswith all cost, hardware etccomplete as per specification and directions of the Engineer-in-charge of the work. |
| 307 | Supplying & fixing Rack Mounting Chargeswith all cost, hardware, conveyance labour for all items of work, HOM with all lead and lift, loading and unloading, transportation charges and all other incidental charges etc., complete as per specification and directions of the Engineer-in-charge of the work. |
| 308 | Supplying & fixing 6 Core Single Mode OFC CableEngieers make with all cost, hardware etccomplete as per specification and directions of the Engineer-in-charge of the work. |
| 309 | Supplying & fixing 6 Port LIU with Face Plate and Cupler Engieers make with all cost, hardware etccomplete as per specification and directions of the Engineer-in-charge of the work. |
| 310 | Supplying & fixingSC Pig Tails SM 1.5 Meter of approved makewith all cost, hardware etccomplete as per specification and directions of the Engineer-in-charge of the work. |
| 311 | Supplying & fixing SC-LC OFC Patch Cord SM Mode 2 Meter of approved makewith all cost, hardware etccomplete as per specification and directions of the Engineer-in-charge of the work. |
| 312 | Supplying & fixing OFC Splicing and Termination Charges of approved makewith all cost, hardware etccomplete as per specification and directions of the Engineer-in-charge of the work. |
| 313 | Supplying & providing Wall Chipping and Filling Chargeswith all cost, hardware, conveyance labour for all items of work, HOM with all lead and lift, loading and unloading, transportation charges and all other incidental charges etc., complete as per specification and directions of the Engineer-in-charge of the work. |
| 314 | Service Charges for Laying of Cat 6 UTP Cablewith all cost, hardware, conveyance labour for all items of work, HOM with all lead and lift, loading and unloading, transportation charges and all other incidental charges etc., complete as per specification and directions of the Engineer-in-charge of the work. |
| 315 | Service Charges for Laying of PVC Pipewith all cost, hardware, conveyance labour for all items of work, HOM with all lead and lift, loading and unloading, transportation charges and all other incidental charges etc., complete as per specification and directions of the Engineer-in-charge of the work. |
| 316 | Service Chargesfor Laying of OFC Cablewith all cost, hardware, conveyance labour for all items of work, HOM with all lead and lift, loading and unloading, transportation charges and all other incidental charges etc., complete as per specification and directions of the Engineer-in-charge of the work. |
| 317 | Supplying, Installation and Configuration Charges of all types of systemswith all cost, hardware, conveyance labour for all items of work, HOM with all lead and lift, loading and unloading, transportation charges and all other incidental charges etc., complete as per specification and directions of the Engineer-in-charge of the work. |
| 318 | Part F - AEC & PROJECT MANAGEMENT WORKS |
| 319 | Project Management Consultancy Services for construction of new seafarers club with following scope of work.1. Carrying out site visits minimum once in a week, inspecting the work, advicing the contractors and clarifying the doubts with regards to the drawings and works to be executed.2. Preparation and submission of additional architectural drawings as and when required.3. Attending periodic review meeting.4. Presence during the visit to purchase of spot purchase items, suggesting on various items to be purchased so as to meet the planned concept. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail