| 1 | Earth work in excavation over areas (exceeding 30 cm in depth 1.5 m in width as well as 10 Sqm in plan) including disposal of excavated earth,lead up to 50 m, disposed earth to be levelled and neatly dressed: All kinds of soil |
| 2 | Earth workin foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. Orinary rock |
| 3 | Filling available excavated earth ( excluding rocks) in plinth side of foundation, under floors in layers not exceeding 20 cm in depthincluding, watering, ramming consolidating and dressing completelead up to 50 m and lift up to 1.5 m, |
| 4 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level : 1:5:10 (1 Cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) |
| 6 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) over 75 mm bed by dry brick ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth |
| 7 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 8 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 9 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-Ill) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings and bases for columns. |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, cantilevers plinth Beam,Girders bressumers and cantilevers |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form for Shelves (Cast in situ) |
| 13 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars |
| 14 | reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 15 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 Cement : 6 coarse sand) |
| 16 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 17 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 18 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 19 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood |
| 20 | Providing wood work in frames of false ceiling, partition and other frames fixed in position:First class local wood(Tita champa / Pine/tiger) |
| 21 | Providing and fixing plain multipurpose cement board(Hight pressure steam cured) with suitable screws for cement particle board in ceiling etc. complete (frame work to be paid seperatately)6IS: 6 mm thick Cement fiber board, Type-B, Category-lll as per :14862 : 2000 |
| 22 | Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete :2nd class teak wood/local wood50x12 mm |
| 23 | Providing and fixing in wall lining flat pressed three layer (medium density) particle board or graded wood Pre-laminated one side decorative lamination and other side balancing lamination Grade I, Type II, IS : 12823 marked, including priming coat on unexposed arrangement and screws etc. complete : 18 mm thick |
| 24 | Providing and fixing panelled or panelled and glazed shutters doors, windows and clerestory windows including ISI marked black enameled M.S. butt hinges with necessary screws (screws should be of stainlesss steel and brand Magnum/ Nettlefold/Amul) excluding, panelling which will be paid for seperately (Thickness of shutters should be 35mm):first class local wood (Tita champa / Pine)confermingIS- 399:1963 (Weight of should be 545 Kg/ M3): 35 mm thick shutterrs |
| 25 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick :First class local wood(Tita champa / Pine/tiger) |
| 26 | Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws; 30 mm thick shutters: With ISI marked M.S. pressed butt hinges of required size: First class local wood (Tita champa/Pine/tiger) |
| 27 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. complete: fixed to windows openings/wooden frame with screws |
| 28 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than gradeAC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :250x16 mm |
| 29 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than gradeAC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 150x10mm |
| 30 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than gradeAC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 100x10mm |
| 31 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than gradeAC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : Size 125mm |
| 32 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than gradeAC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : Size 100 mm |
| 33 | Providing and fixing aluminium casement stays, ISI marked, anodised (anodic coating not less than gradeAC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. |
| 34 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete.40mm thick with 20mm nominal size stone aggregate. |
| 35 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm |
| 36 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sgm including pointing the joints with white cement and matching pigment etc., complete. |
| 37 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : in 15622 (thickness to be specified by the manufacturer) of approved make all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 38 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in length upto 1.20 metreor as desired by Engineerin-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 39 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm +/- 5% total coated thickness (TCT), Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers complete :Ridges plain (500 - 600mm) |
| 40 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 41 | 12 mm cement plaster of mix: 1:6 (1 cement : 6 fine sand) |
| 42 | 20 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand) |
| 43 | With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plyboard. |
| 44 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour :New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than50 gram/litre |
| 45 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) contentWith water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
| 46 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm |
| 47 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work |
| 48 | 25 mm wooden planking,tougued and grooved in flooring, including fixing with iron srews complete with: Local wood Tita/Champa/Pine/Tiger |
| 49 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.: MC round bar 12mm dia to be embedded in wooden chawkhats horizontal. 10 cm c/c |
| 50 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :150x10 mm |
| 51 | Providing 40x5 mm flat iron hold fast 400 mm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 300x100x150 mm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 52 | oviding and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125mm |
| 53 | Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets : 20 mm |
| 54 | Providing and fixing PVC trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 100 mm inlet and 100 mm outlet |
| 55 | Providing and fixing white vitreous china water closet squatting pan (Indian type) :17.13.2 Orissa pattern W.C. pan of size 580x440 mm |
| 56 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap |
| 57 | Providing and fixing soil, waste and vent pipes : 110 mm dia uPVCpipe . |
| 58 | Providing and fixing soil, waste and vent pipes :75 mm diameter :uPVCpipe as per IS: 3989. |
| 59 | Providing and fixing plain bend of required degree 100mm dia PVC socketed pipe |
| 60 | Providing and fixing plain bend of required degree 75mm dia PVC socketed pipe |
| 61 | Providing and fixing 100 mm dia P trap. |
| 62 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. 15 mm dia nominal bore(Medium Class) |
| 63 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall.20 mm dia nominal bore(Medium Class) |
| 64 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15 mm nominal bore |
| 65 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. |
| 66 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 20 mm nominal bore |
| 67 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 68 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:17.7.2 White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap |
| 69 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 70 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour |
| 71 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group A |
| 72 | Supplying and fixing PVC batten/ angle holder including connection etc. as required. |
| 73 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.2.12.1 40 amps |
| 74 | Supplying and fixing 18 watt Led Tubelightincluding connection etc. as required. |
| 75 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 76 | Providing and laying 60 mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. |
| 77 | Providing and fixing of White LED Based Solar Street Lighting System Power output of PV Moudle 40 Wp (forModel III), Type of Battery Lithium Ferrophosphate battery (forModel III &IV) Battery capacity 12 V, 40 Ah for Model I Height of pole 5 meters above theground level for Model III& IV Material of battery box for housingthe battery Acid proof and corrosion resistant Metallic box with locking arrangement as per direction of Engr in charge. |
| 78 | Providing and fixing of Power Control Center Panel (PCC Panel) As Per IS 11717, panel of the apacity of 37KW ,The panels shall be excatly simmilar tothe existing L&T makeType-SYNF633panel of PCC-406 in all respect ,As per SLD 2 modules in each vertical panel of the capacity of37KW,The panels shall be excatly simmilar to theexisting L&T make Type-SYNF633 panel of PCC-406 in all respect, as per direction of Engr in Charge. |
| 79 | Providing and laying 35 SQMM 2 CORE Alumn armed XLPE Cable For Working Voltages Up To And Including 1.1 KV As Per IS 7098 (Part 1) Properties of XLPE insulation as per Table 1 of IS:7098 (Part 1):1988 latest as perTable 1 of IS:7098 (Part 1):1988 latest Number of armouring wire / strip for each size ofcable (in Nos) - 07, & as per direction of engr in charge |
| 80 | Providing and laying 4 mm Core Circular Sheathed Cable With Flexible Conductor (V2) As Per IS 694, Conductor material (Complying with IS:8130:1984 latest) Annealed Tinned Copper Cable Construction Type Single Core Cable No of core 1 Nominal Cross Sectional Area of Conductor (in Sqmm) 4 Sheath type Type ST3 Colour of sheath Black Conductor material (Complying with IS:8130:1984latest) Annealed Tinned Copper Thickness of Insulation As per (Clause 17.1.2) of IS 694 etc as per direction of engr in charge. |
| 81 | Providing and fixing of 45 watt street lights LED Luminaire For Road And Street Lights (V2) Conforming To IS 10322 complete fitting with pole LED luminaire luminous Efficacy(Lumen/watt) (Hint: Total LumenCalculation: Example: 18 W LEDRating x 100 Lumen/Watt = 1800Lumens, 18 W LED Rating x 120Lumen / Watt = 2160 Lumens, 18W LED Rating x 140 Lumen/Watt =2520 Lumens) - 100, Conformity of the specification Conforming to IS 10322 (Part 5/Section 3) andParticular Requirements for LED Street LightingLuminaire conforming to IS 16107 (Part 2/Section2) Type of luminaire [Ref. Cl. 1.1 of IS 16107(Part2/Section 2)] Type A, as per direction of engr in charge. |
| 82 | Random rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) at window sills, ceiling level and the like. Cement mortar 1:6 (1 cement : 6 coarse sand) |