| 1 | 1.Construction of Community Hall at Mankottainatham Habitation in Vallur Panchayat |
| 2 | Earthwork excavation for foundation in all soils and sub-soils to full depth as may be directed except in hard rock requiring blasting but inclusive of shoring, strutting and baling out water wherever necessary and refilling the sides of foundation with excavated earth in layers of not more than 15 cm. thick well rammed and consolidated and depositing the surplus earth in all places shown by the departmental officers with initial leads and lifts, etc., including levelling the sites complete complying with standard specifcations and as directed. |
| 3 | Filling the basement with river sand including cost and conveyance of all materials and all labour charges etc complete. |
| 4 | Cement concrete 1:4:8 mix using 40mm guage hard broken granite stone jelly for foundation including watering wherever necessary and laid in layers not more than 15cm thick compacting etc.,complete complying with standard specifications and as directed. |
| 5 | Collection and supply of gritty gravel from appd quarry including cost and conveyance of all materials to site including all labour charges for filling etc.complete, |
| 6 | Brick work in cement mortar 1:5 mix using IInd class country bricks of size 23 x 11 x 7 CM including the cost and conveyance of all materials and all labour charges and including curring etc., complete complying with standard specifications. |
| 7 | Brick work in cement mortar 1:5 mix using IInd class country bricks of size 23 x 11 x 7 CM including the cost and conveyance of all materials and all labour charges and including curring etc., complete complying with standard specifications. Superstructure- Ground floor |
| 8 | Supplying and Fabricating and placing in position MS steel or ribbed for steel for all reinforced cement concrete works as per the design given including cost of steel and binding wire in all floors etc, Complete complying with stanard specification. |
| 9 | Providing and laying in position, Standardised Concrete mix M-25 Grade in accordance with IS 456-2000, using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement concrete 350kg/m3 and maximum water cement ratio of 0.5, including admixture (plasticiser / super plasticiser) in recommened proportion as per IS :9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0cu.m) 7730kg of 20mm machine crushed stone jelly and with about (3.3cu.m) 5156 kg of 10-12mm machine crushed stone jelly and wiht about (4.79cu.m) 7670 kg of M.Sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fanc clams in the RCC floor/ roof slabs wherever necessary without claiming extra, etc, complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards . (No separate payment will be made by the Department for hte excess usage of materials). |
| 10 | Providing and laying in position, Standardised Concrete mix M-25 Grade in accordance with IS 456-2000, using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement concrete 350kg/m3 and maximum water cement ratio of 0.5, including admixture (plasticiser / super plasticiser) in recommened proportion as per IS :9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0cu.m) 7730kg of 20mm machine crushed stone jelly and with about (3.3cu.m) 5156 kg of 10-12mm machine crushed stone jelly and wiht about (4.79cu.m) 7670 kg of M.Sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fanc clams in the RCC floor/ roof slabs wherever necessary without claiming extra, etc, complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards . (No separate payment will be made by the Department for hte excess usage of materials). |
| 11 | Supplying and erecting for sides and soffits including supports and strutting upto 3.29M height for plane surfaces in all floor is with all cross bracings using mild steel sheets of size 90cm x 60cm and 10 gauges a stiffened welded with mixed steel angles of size 25mm x 25mm x 3mm for boarding laid over silver oak (country wood) joists of size 10cm x 60.50cm dia spaced at about 9cm center to center and supported by casuarina props of 10cm to13cm dia spaced at75cm center to center etc., complete complying with standard specification and as directed for the RCC works. |
| 12 | Supplying and erecting for sides and soffits including supports and strutting upto 3.29M height for plane surfaces in all floor is with all cross bracings using mild steel sheets of size 90cm x 60cm and 10 gauges a stiffened welded with mixed steel angles of size 25mm x 25mm x 3mm for boarding laid over silver oak (country wood) joists of size 10cm x 60.50cm dia spaced at about 9cm center to center and supported by casuarina props of 10cm to13cm dia spaced at75cm center to center etc., complete complying with standard specification and as directed for the RCC works. |
| 13 | Supplying and applying of two coats of putty of 3mm thick over the exposed RCC surface of ceiling including finishing the joints smoothy with grinding machine and the surface shall be thoroughly cleaned out of dust and scrubbing. The Surface shall then be allowed to dry for atleast 48 hours. It shall then be sand papered (waterproof abrasive sheet) to give a smooth and even surface. Any unevenness shall be made good by applying 1st coat of putty mixed with water on the entire surface including filling up the undulations and applying 2nd coat of putty after 6 hours of 1st coat of putty and th.en sand papering (waterproof abrasive sheet) the same after it is dry and finishing the surface smoothly, etc.,complete complying with standard specifications and as directed by the Departmental Officers. [The rates are inclusive of hire charges for grinding machine with wheel, cost of sand paper (waterproof abrasive sheet), cost of putty blade, labour charges for grinding the joints and sand papering, two coat of putty, scrapping the putty area to level the surface smooth, etc., complete]. The Putty should be got approved by the Executive Engineer before use on work. (Based on SoR 2024-25) |
| 14 | Plastering with CM 1:5,12mm thick.over the cement concrete for floor finish including curing etc., complete complying with standard specifications and as directed by the departmental officers. |
| 15 | Weathering course concrete using best quality broken brick jelly of size 20mm uniform guage in pure slaked lime (no sand to be used)over the RCC roof slab in the proportion of brick jelly to lime being 32:12:5 by volume and laid over in a single layer and consolidated to the required designed and finished thickness beating the concrete with wooden beaters of approved pattern ,keeping the surface constantly wetted by sprinkling lime jaggery water as per standard specifications etc., complete as directed by the departmental officers. |
| 16 | Finishing the top of roof with one course of machine pressed tiles of size 20cm x 20cm x 20mm of approved quality laid in cement mortar 1:3,12mm thick mixed with water proofing compound confirming to ISS by 2% weight of cement used and the joint pointed neatly to full depth of tiles with the same water proofing compound mixed with cement mortar ,red oxide etc., complete complying with standard specifications. |
| 17 | Ceramic tiles flooring laying with new ceramic tiles of size 305x305x6 mm laid in C M 1:3 inculding cost of white cement and labour charges etc |
| 18 | Dadoing the walls with new Glazed tiles of size 150 x150 x6 mm laid in CM 1:2 ,10 mm thick and pointig with white cement using 0.40 Kg/m2 including finishing the joint and pointing flush with ties surface |
| 19 | Supply Steel Door of Size :- |
| 20 | Door -1 |
| 21 | Door -2 |
| 22 | Door -3 |
| 23 | Supply Steel Window of Size :- |
| 24 | Steel Window |
| 25 | Steel Window 1 |
| 26 | Supply Steel Ventilatore of Size :- |
| 27 | Steel Window V |
| 28 | Steel Window V1 |
| 29 | labour chrges for fixing of steel door of size |
| 30 | labour chrges for fixing of steel window of size |
| 31 | labour chrges for fixing of steel window,ventilatore of size |
| 32 | supply and fixing of w/c with foot rest |
| 33 | White washing and of approved colour over a priming coat ,inculding through scrapping, clean removal of dirt etc. complete and inculding necessary plasterof paris , putty whereever required . |
| 34 | Distembering two coats with cement paint of first class quality paint and of approved colour over a priming coat ,inculding through scrapping, clean removal of dirt etc. complete and inculding necessary plasterof paris , putty whereever required . |
| 35 | Exterior Emulsion two coats with cement paint of first class quality paint and of approved colour over a priming coat ,inculding through scrapping, clean removal of dirt etc. complete and inculding necessary plasterof paris , putty whereever required . |
| 36 | Painting two coats over new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with best approved best quality of synthetic enamel paint of approved colour over the existing priming coat etc., complete |
| 37 | Wiring with 2 X 1.5 Sq.mm (22 / 0.3) PVC insulated SC unsheathed Copper conducutor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories inflush with wall with 3 mm thick Hylum sheet cover with TW box And 5 A FT switch with continuous earth connection of 14 SWG TC wire for making good of the concealed portion with suitable colour for PVC concealed Light point / fan point (For electronic Regulator) SD 24 |
| 38 | Light Point |
| 39 | Fan Point |
| 40 | Wiring with 2 X 1.5 Sq.mm (22 / 0.3) PVC insulated SC unsheathed Copper conducutor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories inflush with wall with 150 mm X 100 mm X 113 mm TW switch box with 3 mm thick Hylum sheet cover for 5 A 3 pin non interlocking CS plug with continuous earth wire connection of 14 SWG TC wire for making good of the concealed portion with suitable colour for concealed PVC plug point SD 36 |
| 41 | Supply and run of 2 of 1.50 sq.mm (22/0.30) PVC insulated SC unsheathed copper Conductor of 1100 V grade on 7/20GI bearer wire for service connection mains SD 64 |
| 42 | Service Wire |
| 43 | Supply and run of 2 X 1.5 sq.mm (22 / 0.30) PVC insulated SC unsheathed copper Conductor of 1100 V grade in 25 mm dia GI pipe ( Class \" B \" ) suitably bent at both ends with necessary angle iron upright and end supports for mains. SD 69 |
| 44 | Service Pipe |
| 45 | Supply and fixing of Metre Board on suitable T.W.box with earth connection only.[SD no.125] |
| 46 | Supply and fixing of single box type 4\"-40W flourescent tube fitting with copper choke and condenser with TW round block on wall or ceiling with flourescent tube with PVC unsheathed copper leads from terminals to the fitting of Tube Light [SD 88 ] |
| 47 | Supply and fixing ofCFL Blub with guard ( Philips / Bajaj / Crompton / K Lite ) suitable for incandescent lamp with 60 W bulb.SD 79 |
| 48 | Supply and fixing of 1200 mm ( 48\") AC ceiling fan complete with stepped electronic 300 W regulator with 300 mm down rod on the existing clamp. SD 112 |
| 49 | Supplying ang fixing Rain water pipe 110mm dia |
| 50 | Provision for Sanitary and Watersupply arrangements Charges |
| 51 | Provision for 1000 Lit PVC Tank |
| 52 | Provision for Rainwater Harwesting arrangements Charges |
| 53 | Provision for Electarification Deposit Charges |
| 54 | Provision for Name board charges |
| 55 | GST Amount for providing Service to Government Contract Works for the above works. { GST Amount is the Total GST Amount for overall quoted amount above this row in column \"BB\" for all works in this package} (Refer Clause 13.2 & 13.3 of Section 2 of Instruction to Bidders (ITB) of SBD) Please Enable Macros to View BoQ information |