| 1 | Demolition of cement concrete (unreinforced) in ground floors and paving n exc 15cm thick (below or above ground level) complete all as specified and directed. |
| 2 | Demolition of cement concrete (unreinforced) in ground floors and paving n exc 15cm thick (below or above ground level) complete all as specified and directed. |
| 3 | Dismantling Asbestos Cement Corrugated or Semicorrugatedin Roof covering complete all as specified and directed. |
| 4 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 5 | DismantlingWallandceilingboards(fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed. |
| 6 | Taking down cement or cement lime plaster, any description on brick or stone walls,etc including racking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed by Engr-in-Charge. |
| 7 | Demolition of brick/stone masonry built in cement/lime mortar of any mix including all quoins pillar ashlars masonryand removal complete all as specified& directed by Engr-in-Charge. |
| 8 | Dismantling of 100 mm bore PVC(SWR) drain pipe alongwith fittings and accessoriesjointed in cement mortar and taking out from walls, floors or fromtrenches, if required complete all as specified and directed. |
| 9 | Dismantling floor hearth or wall tiling including cement mortar bedding but not backing removing serviceable tiles to store and rubbish of the premises complete all as specified and directed. |
| 10 | Taking down Chowkatts or frameswith shutters (without taking off shutters from the frame exc 1.5 sq. m but n exc 4 sq m each & removing to store complete all as specified and directed. |
| 11 | Taking down Chowkatts or frameswith shutters (without taking off shutters from the frame n. exc 1.5 sq. m each & removing to store complete all as specified and directed. |
| 12 | M & L brick work with FLY ASH BRICKS {As per IS-13757 (1993) burnt clay fly ash building bricks}, (OLD SIZE BRICKS) straight or curved on plan exc 6 mtr mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 13 | M&L for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted stone masonry built in cement mortar 1:4complete all as specified & as directed. |
| 14 | M&L Rendring 10mm thick in CM 1:6 onbrick work or concrete surfaces fair faces of brick work & surfaces finished even and smooth without using extra cement complete all as specified and directed. |
| 15 | M&L for rendering 15mm thick in CM 1:4 on brick or concrete wall surfacesfair faces of brick work & surfaces finished even and smooth without using extra cement with water proof compound (water proof compound paid seperatly) complete all as specified and directed. |
| 16 | Supply only Integral waterproofing compound complete all as specified and directed. |
| 17 | M&L rendering 5mm thick in cement mortar 1:3 on concrete surfaces in ceiling, finished even & smooth without using extra cement complete all as specified and directed. |
| 18 | Material and labour preparation of newly plastered/unplasteredsurfaces of ceilings & applying three coats of white wash complete all as specified and directed. |
| 19 | M&L for preparing newly plastered surfaces and applying two coats of Oil bound distemper on walls including 2mm thick wall putty complete all as specified and directed by Engineer-in-Charge. |
| 20 | M & L for brooming down old decorated surfaces of walls, plastered or unplastered including cornices, plasters etc and applying one coat of oil bound distemper of approved shade/tint complete all as specified and as directed by Engr- in - Charge. |
| 21 | Demolition Mud in roofs, any thicknes, including plastering , existing tretement and cleaning (whether full thickness removed or only or part there of)etcin all respect and preparing it for further treatment and taking out and disposal of debris & rubbish to a distance exc 1 Km but not exc 1.5 Km complete all as specified & directed by Engr-in-Charge. |
| 22 | M&L screed laid 15mm thick in CM 1:4with water proofing compound over green concrete surface(WPC will be measured and paid seperately) surface finished even and smooth (without using extra lime or cement) complete all as specified & directed by Engr-in-Charge. |
| 23 | M&L Applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sq. mincluding cleaning surfacesover bituminious primer complete all as specified & directed by Engr-in-Charge. |
| 24 | M&LAPP based plymeric membrane minimum weighing 3 Kg/Sqm and minimum 3 mm thick reinforced with polyster non woven reinforcement/mat (center core) with thermal insulation laid by toarch application method with overlaps 100mm on length side and 100mm on the width side as per manufacture,s instructions with fabric (wt not less than 150 gms/sqm) on primed surface including two coat of refelective silver aluminium paint over APP membrane complete all as specified and directed. |
| 25 | M&L for Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, andeves board fixed with self tapping screws complete all as specified and directed. |
| 26 | M&L for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tesile strength of 550 Mpa as in roof covering to wall, fixed with self tapping screws complete all as specified and directed. |
| 27 | M & L rolled sections as in main and cross beam, hipand jack rafters purlins where connected rafters and running rails and guides for sliding doors: fixed with angle cleats other connecting plates complete all as specified and directed. |
| 28 | M & L for plate (plain or chequred channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachement complete all as specified and directed. |
| 29 | M & L for preparation of old painted steel surfaces over 10 cm in width or girth and applying one coat of synthetic enamel paint on old painted surfaces, complete all as specified and as directed by Engr- in - Charge. |
| 30 | M&L For False Ceiling Complete With Armgyp-FB ceiling Tiles of Size 595x595,9mm thick (as approved by GE) fixed with and including galvanised iron Powder coated inverted \"Tee\" or \"L\" section (Concealed GI frame Work) Suspended From Ceiling with provision of Galvanised wire 4mm dia and wall tapping screws including butterfly clips,hold down clips for fixing the board to frame complete all as per manufacturer\"s instruction,complete all as directed and specified. |
| 31 | M&L Plain cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) set in cement mortar 1:6 as in coping of brick masonry wall chajja including weathering slightly rounded or chamfered angles and throating as directed including necessary formwork complete all as specified & directed by Engr-in-Charge. |
| 32 | M&L 75 mm thick PCC(1:3:6) type C2 (using 40 mm graded stone aggregate ) as in plinth protection finished fair and even complete all as specified & directed by Engr-in-Charge. |
| 33 | M&L for PCC (1:2:4) type B-0 (using12.5mm graded stone aggregate), 25mm thick, as in floor complete all as specified & directed by Engr-in-Charge. |
| 34 | Material and labour for Machine cut kota stone slab flooring 18-20 mm thick size not less than 22\" x 22\" laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab over and including 20mm thick cement screed bed in cement mortar 1:6including rubbing and mirror polishing complete all as specified and as directed. |
| 35 | Material and labour for kota stone slab18 -20 mm thick in riser of steps, skirting, dado and pillarslaid and jointed with grey cement slurry mixed with pigment to match the shade of the slab over and including 10mm thickrendering in cement mortar 1:4including cutting, moulding outer edges,rubbing and mirror polishing complete all as specified and as directed. |
| 36 | M & L for light shade Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or colouredmatch over 15mm thick screed bed in CM 1:6 complete all as specified & directed by Engr-In-Charge. |
| 37 | M&L Vetrified Ceramic tiles 10mm thick light shade (square/rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in vertical surfaces as dado/ skirting etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over incl 10 mm thick cement rendering in CM 1:4 complete all as specified and directed. |
| 38 | M&L PCC 1:3:6 type C2 using 20 mm graded stone aggregate as in surface channel/drains etc complete all as specified and directed. |
| 39 | Extra for forming fair finished drain or channel exc 30cm inner girth in cement concrete using extra cement including forms moulds mitred/stopped ends etc complete all as specified and directed. |
| 40 | S&F for 75mm thick steel fibre reinforced (SFRC) drain/manhole cover with iron frames (medium ) complying to the standard specifications as mentioned in the IS 12592 BIS Standard minimum load bearing capacity 5 ton /Sqm in square rectangular or Circular shape complete all as specified and directed by Engr-in-Charge. |
| 41 | S&F PVC (SWR) pipes 110 mm bore single socketed in any length with rubber ring joints fixed to walls/floor complete all as specified & directed by Engr-in-Charge. |
| 42 | S&F PVC (SWR) bends any radius 110 mm bore complete all as specified & directed by Engr-in-Charge. |
| 43 | S&F PVC (SWR),110mmjunction single, (Single T) equal or unequal complete all as specified & directed by Engr-in-Charge. |
| 44 | Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing |
| 45 | 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing. |
| 46 | M&L Glazed ceramic coloured tiles in vertical surface450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of the tiles and over 10 mm thick rendring in cm 1:4 complete all as specified & directed by Engr-in-Charge. |
| 47 | S&F 35mm thick IInd class hard wood factory made panelled door shutter(two panel) with lock rail and panelof 9mmBWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. the size of rail and stiles as per IS: 1003 (part-I), kiln seasoned and chemically pressure treated and fixed to chowkats complete all as specified & directed by Engr-in-Charge. |
| 48 | M&L for framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings, cooler stands (exclusive of steelsheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete & making good the floor in PCC 1:2:4 type B-0 to match the existing floor complete all as specified and directed. |
| 49 | M & L for brooming down old decorated surfaces of walls, plastered or unplastered including cornices, plasters etc and applying one coats of white wash complete all as specified and as directed by Engr- in - Charge. |
| 50 | Material and labour for preprationover new surfaceandapplying two coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as er IS 15489-2004 alkarili and fungal resistance, dirt resistance exterior paint emulsion of required shade (Company Depot tinted) with silicon addtitives @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 ltr/10 sqm complete all as specified and directed. |
| 51 | M&L for providing and applying minimum 1mm thickwall care putty over prepared surface to achieve the surface even and smooth for painting complete all as specified and as directed |
| 52 | Material and labour for complete removal of existing treatmentfrom stone wall /plastered wall andapplying two coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as er IS 15489-2004 alkarili and fungal resistance, dirt resistance,exterioremulsion paintof required shade (Company Depot tinted) with silicon addtitives @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 ltr/10 sqm over 1mm thickwall care putty over prepared surface to achieve the surface even and smooth for painting complete all as specified and as directed |
| 53 | S&F powder coatedanodized aluminium frame and other sections for doors, windows, ventilators, partitions, powder coated of any colour as approved (Thickness or powder coating not less than 50 micron) with one or more rebates including joining cleat for fixing etc complete all as specified & as directed. |
| 54 | S&F Powder coated anodized aluminium door shutters,aluminium sections weighing 0.55 kg/m, powder coated of any colour as approved (Thickness or powder coating not less than 50 micron) including necessary joining cleats, glazing clips, rubber packing, anodized aluminium snap beading, screws, anodized aluminium fittings such as handles 2 Nos in each door, hinges type B-21 100mm long (3 Nos), complete all as specified & as directed. |
| 55 | S&FPowder coatedanodized aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m, powder coated of any colour as approved (Thickness or powder coating not less than 50 micron) including necessary joining cleats, glazing clips, rubber packing, anodized aluminium snap beading, screws, anodized aluminium fittings such as peg stays 150mm long (1 No.), hinges type B-21 100mm long (2 Nos), suitable handle (1 No.) complete all as specified & as directed. |
| 56 | S&F forpowder coated of any colour as approved anodised aluminium grill of approved pattern for windows/ ventilators/doors complete all as specified and directed. |
| 57 | S &FSheet glass 5.5mm thick selectedqualityBlack Colour and glazing with beading and rubber gasket exc 0.5 Sqm in each pane complete all as specified and directed. |
| 58 | Cutting holes in brick/stone walls n. exc. Half brick built in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required all as specified and directed. |
| 59 | S&F in repairsstainless steel rod of 20 mm inner dia (in lengths as directed)including decorative finial at both ends and pair of stainless steel brackets fixed at both ends with rawl plug & steel screws on walls/beam,complete all as specified and directed. |
| 60 | Dismantling of stone slab and tiles of any description or thickness in floors, aprons etc laid, beded and pointed in any mortar including removing the dismantled material complete all as specified and as directed. |
| 61 | M&L for Granite slab 18-20mm thick approved shade as in cooking platform, window cill and the likes, machine cut , bedded and jointed with grey cement slurry and pointed with white cement with admixure of pigment to match the shade of granite stone including cutting and polishing types andover screed bed 20 mm thick CM1:6 cement concrete complete all as specified and directed. |
| 62 | M&L 100 mm thickPCC 1:4:8 type D2 (using 40mm graded aggregate) as in foundation filling and mass concrete as floor sub base complete all as specified and directed. |
| 63 | M&L for PCC1:2:4 type B2 using 40mm graded aggregate 100mm thick as in floorcomplete all as specified and directed |
| 64 | Forming Construction joint 30mm deep x10mm wide filled with sealing compound, Grade ‘A’ complete all as specified and directed |
| 65 | Dismantling fencing wire mesh,any type including Mild steelbars, flat iron , nuts & bolts etc complete all as specifeid and directed . |
| 66 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion in natural groundand making good disturbed ground complete all as specified and directed. |
| 67 | Excavating in post holes (or similar) each n. exc 0.5 cum getting out returning filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25 cm as in soft/loose soil complete all as specified and directed |
| 68 | M & L for Cement Concrete type C 2 1:3:6 using 40 MM graded stone aggregate as in foundation filling and mass concrete in fixing offencing postincludingnecessary form work if required at site complete all as specified and directed. |
| 69 | S & F for fencing post/Hand rails, half round or other stock section including embeding in concrete and screwing etc. wind ties for roof including securing bolt posts and struts in fencing including cutting tops to shape as directed, drilling holes,notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc.,and similar work conforming to Fe-290 Gde E-165. |
| 70 | S&F mild steel screw bolts (Machine made) with hexagonal or square heads at one end and the screwed the other to be fitted with washers and one hexagonal or square but exc 5 cm but n.exc 10 cm long, dia of shank 5 to 10mm complete all as specified and directed. |
| 71 | Supply only Chain link MS galvanisd fencing, any size or type complete all as specified and approved by GE. |
| 72 | Fixing only Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc.including provission of binding wire complete all specified and directed. |
| 73 | M&L for mild steel round bars of 10 mm dia and over conforming to Grade E-165 (Fe 290) as in handles of man hole covers & similar works including necessary cutting etc and fixing in position complete all as specified & directed. |
| 74 | S& F galvanised, 2 strand, steel barbed wire 2.24 mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) |
| 75 | M & L for treatingends of posts, backs of chowkhats, etc., area tarred exc. 0.1 Sqm but n.exc 0.5 Sqm each complete all as specified and directed. |
| 76 | S&F for preparation of new steel surface of any description over 10cm width or girth & applying two coats of synthetic enamel paint over a coat over red oxide primer complete all as specified and directed. |
| 77 | All as per srl item No 76.00 but n.exc 10 cm width or girth |
| 78 | Taking down carefully copper/aluminium point wiring of any size (light, socket or power) complete (fittings such as switches, ceiling roses, pendants, regulatos, sockets etc to be measured separately),and making good disturbed surfaces of walls, floors etc to match with existing surfaces complete all as specified and directed. |
| 79 | M&L for concealed Point wiring for One Light point controlled by one, one way switch with two single core PVC insulate, unsheathed multistranded copper conductorcable of size 1.5 sq.mm (FRLS) drawn in and including electrical grade PVC conduit20 mm dia concealed on wall/ceiling/floorincluding PVC insulated unsheathed earth wire with multi stranded copper conductor of size 1.5 sq.mm(FRLS) including Modular MS shunk sheet metal box with modular cover plate of required Module with brass counter shunk screws with washer complete all as specified. Note - Quoted rate shall include cost of cutting chases in Stone/Brick Wall for inserting PVC Conduit and Cost of Modular Cover plate of required module and making good to the disturbed surfaces including plastering andpaintingto match with the existing colour. |
| 80 | All as per srl item No 79.00 but for One 3 pinswitch socket outlet, 5 Ampon the same board with other switches. |
| 81 | All as per srl item No 79.00 but for One 3 pin 5 amps switch socket outlet pointon independent board. |
| 82 | All as per srl item No 79.00 but for One Ceiling Fan/Exhaust Fan point controlled by one switch and regulator |
| 83 | All as per srl item No 79.00 but for wiring with 4.0 sq.mm multistranded cable and earth wire with copper conductor of size 4.0 sq.mm for 15 amps power/geyser point. |
| 84 | All as per srl item No 79.00 but for one 3 pin 15/16 Amps socket outlet controlled by one 15/16 Amps switch on independent board with 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade including 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour. |
| 85 | Supply and fixing in repair Modular switch, one way 6 Amp, 1 module, piano type, 230/250 volts grade on top covers (catered in point wiring above) complete all as specified and directed. |
| 86 | All as per srl item No 85.00 but for Modular switch, one way 16 Amp, 1 module |
| 87 | Supply and fix in repair Modular socket outlet 2in1, 3pin 5A, 2 module, multipurpose use, flush mounting type, 230/250 Volts grade on Top covers (catered in point wiring above) complete all as specified and directed. |
| 88 | All as per srl item No 87.00 but for Modular socket outlet 2in1, 3 pin 15 Amps flush type |
| 89 | Supply and fix in repair ceiling rose surface bakelite two to three terminals/plate, polycarbonate, isolated body complete all as specified and directed. |
| 90 | Supply and fixing in repair PVC Blanking Plates one way with internal lock complete all as specified and directed. |
| 91 | Supply and fix in repair Lamp holder, PVC/Polycarbonate type complete with lamp LED 9 Watt for Batten fitting with back plate and all fittings complete all as specified and directed by Engr-In-Charge |
| 92 | Supply and fixing in repair LED 36 Watt ultra slim edge 2x2 feet lit panel in aluminium casing recess mounted square fixtures in white finish suitable for low ceiling height, 3 in 1 , 3K, 4K, 6K with & including LED prewired and connecting up dismantling of old UNSV recessed mounted light complete all as specified and directed. |
| 93 | Supply and fix LED batten (1.2m) made of CRCA sheet housing with a PC glossy diffisure duly prewired connection having nominal system lumen output of 2000 lumens at a minimum system efficiency of 115 lumen per watt and total power consumption not more than 20 watt including driver. it should have rated system life time of 40000 burning hours at L70 and should have a temperature of 6500 K CRI >80, thd <10 and PF>0.95 complete all as specified and directed. Make - Crompton Cat Part CIS-305-40-57-SL-DP-NWH, Philips Cat part BN308C LED20S-6500 L120 PSU WH, Havells Cat Part STOUTPLUS600BS20WLED840SPCWH |
| 94 | Supply and fixing LED light fitting as building security lights of 35 Watt Cap 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, with epoxy powder coated CRCA sheet steel grey tray, clear acrylic cover,incl street light bracket made out of 25 mm dia GI medium grade pipe 0.6 mtr long complete with 2 sets of FI clamps made out of 30x5 MS flat & nuts, bolts & washer including painting to clamp with two coats of aluminium silver paint over a coat of primer, with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engr-In-Charge |
| 95 | S&F sheet metal enclosure concealed in wall incl making good of disturbed surfaces double door type suitable for fixing MCB\"s, SPN with 200 Amps rated bus bar, 8 Way, 230 Volts and including taking down old U/S DB, SPN, 8 way complete all as specified & directed. |
| 96 | Supply and fix in repair VerticalTPN DB 4 way suitable for Double Pole outgoing MCB-40 Amp-04 Nos with incoming 100 Amps, 16 KA, MCCB 4 pole-01 Nos complete with 250 Amps rated Copper busbar flush mounting, double door, proction class IP-30, IK08 complete all as specified and directed. |
| 97 | Supply and fixing in repair SP 6-32 Amp, 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed by Engr-In-Charge |
| 98 | All as per srl item No 97.00 but for SPN 40-63 Amps |
| 99 | S&F in repair modular AC Box 3 Module complete with 01 No. 32 Amps 3 Pin Socket Outlet and 1 Nos Single pole MCB 32 Amps & including taking down old U/S enclosure complete all as specified & directed . |
| 100 | Material & Labour for Sub Main Wiring in repair with two run single core 6 Sqmm PVC insulated unsheathed(FRLS) cable with stranded copper conductor drawn in PVC conduit & accessories Suitable size with and including 6 Sqmm copper green colour earth wire all as specified and directed by Engr-in-Charge.NOTE-two run of 6 sq.mm & One run of 6 sq.mm & One run of PVC conduit with accessories shall be measured as One length complete all as specified and directed. |
| 101 | Material and labour for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.30mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/panel/equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre, charcoal and salt in alternate layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15 mm bore 3.00 metre long GI pipe light grade for earth wire protection fixed with poles with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers,PCCchamber (1:3:6) type C1, 40mm thick precast RCC cover 1:2:4 type B1 shall be provided on CI frame etc complete all as specified & directed. |
| 102 | Supply and lay in repairs and testing of 35 Sqmm 3.5 Core cable LT XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with stranded aluminum conductor, 1100 Volts grade, complete all as specified and directed.Note:-Excavation, earthwork, will be measured and paid separately under respective items of this Schedule. |
| 103 | All as per srl item No 102.00 but for 10 Sqmm 2.0 Core |
| 104 | Excavation in trenches not exc 1.5 m wide and n. exc 1.5 m deep in soft/loose soil for foundation/ cable etc n exc 10 Sqm on plan and n exc 1.5 Sqm in depth all as specified and directed by Engr-in-Charge |
| 105 | Returning, filling in including spreading levelling, watering and well ramming in layer n. exc 25 cm thick complete all as specified and directed. |
| 106 | Removing surplus soil to a distance n. exc 50 m and depositing where directed at level n. exc 1.5 m above the starting point complete all as specified and directed. |
| 107 | Supply and spreading, levelling river sand in trenches for cables cushioning on top and bottom of cable complete all as specifede and directed. |
| 108 | M&L brick protection with sub class \"B\" brick laid flat across the cable complete all as specified and directed |
| 109 | M&L for boring under roads for crossing of UG Cables complete all as specified and directed by Engr-In-Charge. |
| 110 | Supply and fix GI Pipe light grade of size 40 mmlaid in trenches under road/fixed on wall/pole for cable protection complete all as specified and directed by Engr-In-Charge |