| Sl. No. | Item Description |
| 1 | (SCHEDULE-A PART-I B/RWorks) Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exc 1.50 sqm each and removing from site, complete all as specified and directed. |
| 2 | Taking down chowkats or frames with shutters (without taking off shutters from the frames)exc 1.50 sqm eachand n exc 4 sqm and removing from site,complete all as specified and directed. |
| 3 | Demolition of brick work built in cement mortar including all quions, arches, pillars etc but excluding ashlarfacings dressed stone work and precast concrete articles,complete all as specified and directed. |
| 4 | Demolition of cement concrete (unreinforced) of any description and any position not other wise specifically provided complete all as specified and ditrected. |
| 5 | Demolition of cement concrete (Reinforced) of any description and any position not other wise specifically provided reinforcement cut as required to facilitate demoltion complete all as specified and directed. |
| 6 | Taking down cement plaster on brick or concrete surfaces, parapets including raking out joint, hacking for key, scrubbing down with water, at any description with necessary scaffolding of max height for G+1 Bldgsetc complete all as specified andas directed. |
| 7 | S&F Pressed steel frames of size 125 mm X 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and directed.. |
| 8 | S & F for 35 mm thick factory made, 2nd class hard wood glazed and skeleton shutters open rebeated and prepared to received glass, gauzed, with outsash bar edges of framing plain, chamfered or rounded, fitted with cut and mitered beads for securing glass etc, size of member of shutter as perspecified in SSR Part-I Section 8, clause 8.24 (a) and for door and fixed with chowkats, chemically pressure treated complete all as specified and as directed. |
| 9 | S&F for 35mm thick 2nd class hard wood plain, framed pannelled shutters (two panel) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board wiyh commercial veneering on both faces. The size of rail and stile as per (IS : 1003 part-I , kiln seasoned and chemically pressure treated complete all as specified and as directed. |
| 10 | S&F powder coated aluminium frame work (min thickness of powder coating 50 micron)for doors, windows, ventiltors and partition, (sliding/openable/fix doors, windows, ventilator), etc with one, two or more rebates (reqd as per site), section weighing not less than 0.55 kg/m, includingjoining cleat for fixing with dash fasteners of required dia and size, incl filling up gaps at junctions, ie top, bottoms and sides etc complete all as specified and directed.. |
| 11 | S&Fpowder coated aluminium window and ventilator shutters, sliding/openable/fixed (as per required at site)type without sash bar, alu section weighing 0.55 kg/m, including necessary locking arrangement, guide wheels, joining cleats, glazing clips rubber packing anodised alu snap beading screws etc complete allspecified and directed. |
| 12 | S&F for sheet glass palin/coloured (as per directed by Engr-in-charge) 3mm / 5 mmthickbest qualityandglazing with rubber packing, screws or glass putty in squares exc 0.5Sqmeach panecomplete all specified and directed. |
| 13 | S & F for stainless steel wire cloth of0.36mm dia wire and average width of aperture 1.40mm & fixed with tacks or screws, wire staples, etc complete all as specified and directed. |
| 14 | S&F aluminium anodised grill 6mthick fixed to aluminium window with and including \"H\" type aluminium frames of size 34mm x 11mm complete all as specified and as directed. |
| 15 | S&F Factory made solid PVC door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube with wooden grain printed PVC sheet used inserted of plain colour PVC sheet & edges will be painted to match with printed sheet complete all as specified and directed. |
| 16 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails.MS frame shall be covered with heat moulded plain colourPVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail.Panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, complete all as specified and directed. |
| 17 | S&F 100 mm long mild steel butt hinges, cold rolled, medium weight complete all as specified and directed. |
| 18 | S&F for 125mm long anodised aluminiumbarrel tower bolt of extruded section complete all as specified and directed. |
| 19 | S&F 150mm long anodised aluminium handles, cast type complete all as specified and directed. |
| 20 | S&F 300mm long aluminium alloy, anodized sliding door bolt with hasp stapple ( bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed. |
| 21 | S&F for20 to 25 mm dia stainless steeldraperycurtain rod withbrass /nickel chrom polish / designer lattos and brackets complete all as specified and approved by Engr-in-Charge including taking out old pelmet with curtain rodscomplete all as specified and directed. |
| 22 | S&F 300 mm long mild steel ordinary rat tail rod pattern spring including roller and roller plate complete all as specified and directed. |
| 23 | S& F Floor door stopper of aluminium alloy bodyand tongue ,anodised ,with hard drawnsteel spring ,fixed in floor overall length of cover plate140mm complete all as specified and directed. |
| 24 | M&L for brick work with sub class \"B\" bricks straight or curved on plan exc. 6m mean radius built in cement mortor 1:6., etc complete all as specified and directed. |
| 25 | M & Lfor brick work with sub class \"B\"modular bricks, straight or curved on plan to any radius built in CM 1:4 in half brick thick walls complete all as specified anddirected. |
| 26 | M&L for rendering 10mm thick in CM 1:6 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed. |
| 27 | M&L for rendering 15mm thick in CM 1:4 on other than fair faces of brick or concrete surface with liquid water proofing compound @ 200 ml per bag finished even and smooth without using extra cement with necessary scaffolding of max height for G+1 Bldgs complete all as specified anddirected.(Note:- Liquid water proofing compound to be measured paid separately) |
| 28 | M&L for rendering 5mm thick in ceiling CM 1:3 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed. |
| 29 | Supply only integral water proofing compound complete all as specified and directed. |
| 30 | M&L plain cement concrete 1:4:8, type D2( using 40mm graded stone aggregate) 75mm thick as in sub base of floor complete all as specified anddirected . |
| 31 | M&L for dismantling floor,hearth or wall tiling including cement mortar(but not backing (,removeing servicable tiles to store and rubbish off the premises complete all as specified and directed. |
| 32 | M & L 25mm thick cement concrete type B-0, 1:2:4 (using 12.5 mm graded aggregate) for levelling course in floors complete all as specified anddirected. |
| 33 | M&L for vitrified light shade floor tiles10mm thick (square or rectangular) area of each tile not exceeding 0.36 sqm ,in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to matchthe surface with and including 15mm thick screed bed or bedding layerin CM 1:6 complete all as specified anddirected. |
| 34 | All as per item no33above but as in skirting/ dado etc with and including 10mm thik backing coat in cement mortar 1:4 an wall complete all as specified and directed. |
| 35 | M & L for non skid joint free coloured ceramic floor tiles 7 to 8 mm thick (square/ rectangular) area of each tile exc 0.11 sqm but n exc 0.18 sqm,in floor etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the surface with 15mm thick screed bed or bedding layer in CM (1:6) complete all as specified anddirected. |
| 36 | M&L for glazed ceramic coloured wall tiles (textured and design as required) in vertical surface 450X300X7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick rendering in 1:4 CM complete all as specified anddirected. |
| 37 | M & L for applying two coat of synthetic enamel paint on new wooden surfaces of any description over 10 cm width or girth complete all as specified and as directed. |
| 38 | M & L for preparing new plastered surfaces of wall and applying two coats of distemper oil emulsion over a coat of alkali resistant cement primer and over a coat of 2 to 3mm thickwall care putty complete all as specified and directed. |
| 39 | Material and Labour forapply two coats of Anti fungal weather coat acrylic emulsion paint over a coat of primer on new surfaces including 2 -3 mm thick wall putty, complete all as specified and directed.Note:- (a) Each stage i.e. preparation of surfaces, application of primer, application of first coat, application of second coat will be got passed from Engr-in -Charge.The acrylic emulsion paint work shall be carried out by using smart painting tools and techniques as specified in Particular Specifications and Contractor will have to produce necessary documents for purchase of smart painting tools or rent receipt of these tools along with bill/RAR.The bidders are requested take this aspect in consideration before quoting their rate and no clain on account of misunderstanding or otherwise shall be admissible on this account. |
| 40 | M & L for preparing new plastered surface on ceilingand applying three coat of white wash complete all as specified anddirected. |
| 41 | M&L for preparation ofold decorated plastered or unplastered surface including complete removal by brooming down with steel wire brushing, scraping down smoke soot, moulded, moss, efflorscent salt, trading oil and greasyspots andapplying two coat of Oil bound distemper on walls over 2mm thick plaster of paris putty complete all as specified and directed. |
| 42 | M&L for preparation ofold decorated plastered or unplastered surface including complete removal by brooming down with steel wire brushing, scraping down smoke soot, moulded, moss, efflorscent salt, trading oil and greasyspots andFinishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) on walls over 2mm thick plaster of paris putty complete all as specified and directed. |
| 43 | M&L for three coat ofwhite wash on old surface on ceilingincluding preparation of surface complete all as specified and directed. |
| 44 | M & L for machine cut kota stone slab flooring 20 to 25mm thick (size not less than 550mm x 550mm) laid & jointed with grey cement mixed with pigment to match the shade of slab including rubbing and mirror polishing finished laid over and including 20mm thick screed bed or bedding layer in CM 1:6 complete all as specified and as directed. |
| 45 | M & L for machine cut kota stone slab flooring 18 to 20mm thick as in riser of step, dado and skirting over and including 10mm thick 1:4 CM backing coat on vertical surface of wall with rubbing and mirror polishing finished complete all as specified and as directed. |
| 46 | M & L 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) includingpointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite with providing 15mm thick screed bed in cement mortar 1:4 complete all as specified and as directed.. |
| 47 | M&L plain cement concrete 1:3:6, type B1( using 20mm graded stone aggregate) 75mm thick as in plinth protection complete all as specified anddirected . |
| 48 | Demolition of cement or lime concret in any despription along with tarfelt treatment in sunken portion / roof and cement mortar bedding from roof removal rubbish out side MD land complete all as specified and directed. |
| 49 | M&L for PCC 1:2:4 type B-0 using 12.5mm graded crushed stone aggregate as in roof, sunken portion, subbase, etc complete all as specified and as directed. |
| 50 | M&L for rendering 10mm thick in CM 1:4 on roof suraces with liquid water proofing compound @ 200 ml per bag finished even and smooth without using extra cement complete all as specified and directed. |
| 51 | M&L for water proofing treatment to sunken portition / roof etc. in following sequence:- (i) Properly cleaning and drying the surface(ii) Applying a coat of bitumen primer @ 1.2Kg/Sqm and primer shall be allowed to dry over night. (iii) Laying APP based modified water proofing membrane of weight not less than 3kg per sqm and thickness not less than 3 mm, with 100mm overlaps, sealed and bonded to the surface by \"torchon\" method (iv) Applying two coat of bituminous based aluminum painting@ 0.15 kg/Sqmeach coat on water proofing treatment with preparation of surfacescomplete all as specified and directed at site. |
| 52 | S&F in repair vitreous china wash down water closet pedestalpattern white excluding flushing cistern and flush pipes complete all as specified and as directed . |
| 53 | M&Lin repairs PVCvalve less,syphonic action type flushing cistern,low level ,white with inlet ball valve,float and handle including bracketsand connection to pipe and fixing of chainand pull or lever if any complete all as specified and directed. |
| 54 | S&F in repair vitreous china wash hand basin white flat back, size 550x400 mm including bracket but excluding taps ,waste pipes , chain and plug etc complete all as specified and directed. |
| 55 | S&F vitreous china urinal bowl urinal flat back, size of 465x355x265mm white (min)with grating and union for discharge pipe, urinal spreader with waste pipe and all fiting for urinal. |
| 56 | S & F in repairs PVC (SWR) nani trap /floor trap plain or multi with stainless steel grating incl joining to waste pipe with solvent cement joint dia of outlet 75mm bore complete all as specified and as directed. |
| 57 | S&F 110mm bore PVC (SWR) bends any radius complete all as specified and as directed. |
| 58 | S&F 75mm bore PVC (SWR) bends any radius complete all as specified and as directed. |
| 59 | S & F 110mm bore PVC (SWR) pipes singles socket in any length with rubber ring joints fixed to walls /floor or in trenches complete all as specified and as directed. |
| 60 | S & F 75mm bore PVC (SWR) pipes singles socket in any length with rubber ring joints fixed to walls / floor or in trenches complete all as specified and as directed. |
| 61 | M & L for Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10cm girth complete all as specified and directed. |
| 62 | Taking up ordown 15 mm dia old serviceable / unserviceable steel tubing any grade and connections cleaning for re-fixing or removal to store complete all as specified anddirected . |
| 63 | All as per item no62 above but 20mm bore complete all as specified and as directed. |
| 64 | S&F steel tubing medium grade ,galvanized with all fitting such as bend ,elbow, socket,tees,and fixed complete to wall or in ceiling or in floors including cutting threading and making forged bends on pipes MS hooks etc ,for 15mm bore pipes complete all as specified and as directed. |
| 65 | All as per item no64 above but 20mm bore complete all as specified and as directed. |
| 66 | S&F in repair for 15mm bore bib taps chromium platedwith crutch or butterfly handle ,screwed down , screwed for iron pipes or brass ferrulecompleteall as specified and directed. |
| 67 | S&F in repair CP angle stop cock of 15mm bore screwed down for high pressure with crutch or butter fly handle ,screwed both end for iron pipes complete all as specifiedand directed.. |
| 68 | S&F in repairs PVC connection15mm size with PTMT nuts of length 450 mm long complete all as specified and as directed. |
| 69 | S & F in repair 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washer complete all as specified and directed. |
| 70 | S& F in repair Rotational moulded Polyethylene water storage tank 1000 liters capacity (cylidrical vertical with closed top) hoisted and fixed in position all as specified in SSR part I incl brass float valve 20mm dia and dismantling water tank. complete all as specified and directed. |
| 71 | S&F in repairstop valves fancy type chromium plated with long shanks fixed with 15 mm dia bore pipes complete all as specified and as directed. |
| 72 | M & L high strength steel deformed TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping columns,hookings ends and binding with mild steel wire (annealed) not less than 0.90 mm dia or securing with clips, etc complete all as specified and directed. |
| 73 | M & L for formwork fair and finished surfaces to sides and soffits of floor or roof beam, beam hauchings, bands, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc complete all as specified anddirected |
| 74 | M&L Reinforced Cement Concrete M-25 using 20 mm graded stone aggr as in beams, bands, cantilvers, bressummers, linters, chajjas, over 1.5m span deck slabs and in drain cover slabs , shelves and similar works etc complete all as specified anddirected |
| 75 | M&L for 80mm thick machine pressed precast concrete interlocking paver block (glossy finish) of M-40 Gde of approved shape, size and colourconferming to IS 15658-2006 and laid over and including 30mm thick stone grit cushion complete all as specified anddirected. |
| 76 | M & L for precast cement concrete type B-1 (1:2:4) (20mm graded stone aggregate ) as in kerb and edging to road and foot path, etc including chamfered, weathering, throating etc and setting in CM (1:4) complete all as specified and directed. |
| 77 | S & F in repairs MS framed work as in doors or gates of angle iron, door frame or other section with gusset plate, rails, braces and stair case etc complete, drilled for fixing of steel sheeting or other covering etc, to prepared for hanging or sliding with including either hooks and hinges also fastening grills, grating, hold fast of doors and windows chowkat etc, with ends of bars shouldered and or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walkways; railings; framework of water tanksand fixing and similar work confirming to fe 290 Gde E-165 complete all as specified and as directed. |
| 78 | M&L for preparation of new steel surfaces exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified anddirected. |
| 79 | S & F steel work in tubular trussles,purlins,rafters,tubler column, where connected common rafter and running rails fixed with angle cleat or other connection plates including special shaped washers etc.complete using ERW or inductionbutt welded tubes confirming to Fe 410W grade E 250 quality B, etc complete all as specified anddirected. |
| 80 | S & F 0.50mm thick (including coated thickness) Pre-colour, pre-profiled ( Galvalume ) sheets of required colour and design having tensile strength of 550 Mpa as in roof, wall cladding, north light curves, fixed with zinc coated self drilling fastener including EPDM washer complete laid with one corrugation side laps and min 150mm end lap laid to slope all as per manufacturer/ profile maker instruction complete all as specified anddirected. |
| 81 | S&F in repair CP mixer for mixing hot & cold water screwed down for ironpipe 15mm borecomplete all as specifiedand as directed. |
| 82 | S&Fixed in repair 125 mm size chromium plated showerrosewith siwel joint suitable for 15 mm bore GI pipes comlete all as directed.. |
| 83 | Demolition and breaking up 150mm dia drain pipes (Salt glazed ware, AC or reinforced concrete ) and set in cement mortar all as spd and directed by Engr in Charge. |
| 84 | M&L for concrete bed to drain pipes including packing under, and haunching against the sides of 150 mm bore pipes in cement concrete 1:3:6 type C-2 ( using 40 mm graded stone aggregate) after they are laid and tested complete all as specified anddirected. |
| 85 | M&L for 150 mm boresalt glazed stone were (SGSW) drain pipe grade \"A\"laid to slope in tranches and jointed in cement mortar (1:1) including necessary testing for ensuring teak proofing complete all as specified and directed. |
| 86 | M & L for Cutting into existing manhole for connecting new drains and making good to pipes and rendering cutting out existing benching for and forming branching for and forming branch channel (1/2 round or ¼ section ) in PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate smooth finished and reforming benching as specified and directed for 150mm dia of pipe complete all as specified. |
| 87 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundation or etc, for shafts, wells, cesspits, manholes, pier holes, etc n.exc 10 Sqm on plan and n.exc 1.5m in depth and getting out in soft/loose soil, complete all as specified and directed. |
| 88 | M&L for PCC 1:4:8 type D2, using 40mm graded stone aggregate, as in foundation filing, and mass concrete , etccomplete all as specified and directed |
| 89 | Removing excavated material (soil) to a distance not. exc. 50 mtr and depositing where directed at a level nexc 1.5 mtr above the starting point complete all as specified and directed. |
| 90 | M & L cement concrete type B1 1:2:4 ( 20 mm graded aggregate) as in coping, bearing course, manhole/ drain channels etc in including necessary formwork complete all as specified anddirected. |
| 91 | M&L for cement concrete 1:3:6 type C-1 using 20 mm graded stone aggregatre as in surface channels and drains complete all as specified and directed. |
| 92 | Extra for forming fair finished drain or channel exc 30 cm inner girth in cement concrete, using extra cement, including forms moulds, mitred/stopped ends etc complete all as specified and directed. |
| 93 | M & L for preparing new plastered surface on walls and applying three coat of white wash complete all as specified anddirected. |
| 94 | S&F in repair kitchensink with drainage board made of stainless steel 1.0 mm thick in kitchen with plug , washer and waste including bedding layer in CM (1:6) in wallor including fixing cantilever bracket and connecting union to pipes over all size 915x460 mm bowl size 410x330x160 mm including taking out unserviceable kitchen sinkcomplete all as specified and as directed. |
| 95 | M&L for stain less steel plate rack for kitchen 1 mm thick of best quality with suitable hanging arrangement and fixed to wall complete all as specified and directed. .Note:- Size of plate rack should not be less than 900x1200 mm and weight of rack shall not be less than 8.5 Kg each. |
| 96 | S & F forPVC and cupboard shelf/ partition/ frame / shutter of 18mm thick side of panel externally impact perfact finish to the shutter and joined together with solvent cement adhesive 8mm thick (4mmx2)x12mm wide PVC sheet is used as gap insert for top & bottom rail, 18mm x 1mm PVC edge lipping is done on top & bottom side using PVC solvent cement adhesive, incl hasp and stable for locking purpose, etc complete as per direction of Engr-in-charge, manufacture\"s specification and drawing. |
| 97 | (SCHEDULE-A PART-II E/MWorks) Taking down carefully unserviceable Aluminium point wiring complete (light, fan socket, bell or power) with fitting such as switches, ceiling rose lamp holder, regulators, sockets,light fittings etc.and keeping in safe custedy for takingcredit complete all as specified and as directed. |
| 98 | M&L for point wiring with PVC insulated unsheathed 1100 volt grade FRLS cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and inPVC conduit of any size, fixing acessories inculding sunken anodised pressed terminal box not less than 1.2 mm thick covered with3 mm thick bakelite laminated sheet cover of suitable size with suitable size screws for mounting switches, sockets, regulators with and including 1.5 sqmm FRLS multi stranded copper conductordrawing as continuous earth wire connected to main earth and earth dollyforOne light/fan point /bell point controlled by one switchswitches/sockets/regulators complete all as specified & directed. (Note :- cost of modular boxes, Suitable modular switch base, frame & cover is included in quoted rate.) |
| 99 | All as per above item 98 but for One 3 pin socket out let 5Amp controlled by one switch on same board complete all as specified and as directed. |
| 100 | All as per above item 98but forOne 3 pin socket out let 5 Amp controlled by one switch on independent board complete all as specified and as directed. |
| 101 | All as per item No 98 here in before but point wiring with 2.5sqmm FRLS multi stranded copper conductor cable for main circuit and 2.5sqmm cable as earth continuity conductor for one 15 Amp socket out let controlled by one 15Amp switch on independat board complete all as specified and directed.. |
| 102 | All as per item No 98 here in before but point wiring with 4 sqmm FRLS multi stranded copper conductor cable for main circuit and 4sqmm cable as earth continuity conductor for one for one one MCB plug and socket point (For Geyser point) complete all as specified and directed. |
| 103 | M&L in replacement of sub main wiring with two single core FRLSPVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 06 Sq mm drawing through and includingconcealed rigid non metallic PVC conduit medium grade ISI marked of suitabledia including one single core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 06 sq mmas earth continuity conductorconnected to commen earth and earth dolly complete including taking down existing UNSV. NOTE: 03 Runs of FRLS cable of 06 sqmm with PVC conduit combined consititutes one RM. |
| 104 | S & F Modular switch one way 5/6 Amps suitable for 1 Module complete all as specified and directed.. |
| 105 | S & F Modular socket 5 pin 5/6 Amps suitable for 2 Module complete all as specified and directed. |
| 106 | S & F Modular switch one way 15/16 Amps suitable for 1 Module complete all as specified and directed. |
| 107 | S & F Modular socket 5/6 pin 15/16 Amps suitable for 2 Module complete all as specified and directed. |
| 108 | S & F Modular Fan step Regulator electronic, 120 watts 2 Module complete all as specified and directed. |
| 109 | S & F Modular blanking plates 1 module complete all as specified. |
| 110 | S&F of ceiling rose 3 terminal complete PVC/Polycarbonate isolated boly complete all as specified and directed. |
| 111 | Supply and fixing LED lights fitting 1x 22 W, 220V, PVC fitting type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 112 | S&F building security lightluminaries energy saving and envirnment friendly long life LED light of 25W made up of pressure die cast aluminium housing with acrylic cover as diffuser with IP66 protection and Impact resistanve of IK07, including MS Bracket light grade 25 mm dia, 1.2 m long bend in shape fixed on wall having an angle120 degree, fixed with and suitable size nuts, bolts and washers making connections with three core PVC insulated and sheathed copper conductor cable etc including taking down of existing light fitting and complete ,all as specified and directed. |
| 113 | Supply and fixing Copper wounded ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor(BLDC) including making connections with three core PVC insulated and PVC sheathed flexible copper conductor cable from ceiling rose to fan andtaking down of old unserviceable ceiling fans from site and deposited in MES store yard complete all as specified and directed.Note :- Contractor shall submit the waranty of 05 years for replacement of defective fan and its accessories from the company |
| 114 | Supply and fix Copper wounded exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame & louvers, making connections with three core PVC insulated and sheathed flexible copper conductor cable from ceiling rose, grouting with nut bolts, hole on wall as requiredincluding taking down of old unserviceable ceiling fans from site and deposited in MES store yard complete all as specified and directed. |
| 115 | Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece making connections with three core PVC insulated and sheathed flexible copper conductor cable from plug and socketincluding taking down of old unserviceable geyser from site and deposited in MES store yard complete all as specified and directed. |
| 116 | S&F sheet metal enclosuredistribution board TPN 4 way415 V, 50 Hz double doorwith neutral, Earthing bar and din rail complete incl taking out existing UNSV DB with MCBs. Complete all as specified and directed. |
| 117 | S&F sheet metal enclosuredistribution board SPN 8 way230 V, 50 Hz double doorwith neutral, Earthing bar and din rail complete incl taking out existing UNSV DB with MCBs complete all as specified and directed. |
| 118 | S&F MCBTPN63 A 10 KA 415 volts \"C\" series complete all as specified and directed |
| 119 | S&F MCBSPN40 A 10 KA 240 volts \"C\" series complete all as specified and directed. |
| 120 | S&F MCB single pole 6 to 32 Amps 10 KA 230 volts \"C\" series complete all as specified and directed. |
| 121 | S&F Single pole and neutral enclosure with a two pin and earth plug and socketcomplete with one single pole MCB 25Amps, 10 KA \"C\" Series complete all as specified and directed. |
| 122 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium stranded conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 16 sq. mm 4 core nominal cross section in service connections complete all as specified and directed. |
| 123 | Excavation in trenches in any type of soil not exc 1.5 mtr in depth and 1.5 mtr wide and getting out for laying of cables complete all as specified and directed. |
| 124 | Returning and filling in including spreading, leveling , watering and well ramming in layers not exceeding 25 cm thick excavated earth complete all as specified and directed. |
| 125 | Removal of surplus soil to a distance not exceeding 50 mtr and depositing at a level not exceeding 1.5 mtrs above the starting point complete all as specified and directed. |
| 126 | Supply and fixingof DWC pipe for cable protectionwith outer dia 40 mm and inner dia 30 mm incl coupler and other accessories as required at site complete all as specified and directed. |
| 127 | M&L for earthing complete for bldgwith galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized earth wire 4.00 mm diaby means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel,PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish ,internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh of 22 gauge,80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI pit shall be filled withcharcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) as specified includingprovision of 15mm dia medium grade GI pipe for earth wire protection and 20 mm dia for watering complete ,all excavation andearth work & connecting the earthing to an earthing test point / main switch board as specified and testing on completion complete all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail