Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | SCH \"A\" PART - I (BUILDING WORK B/R-I PORTION) |
| 2 | Taking down cement plaster on brick orstone masonry Including raking out joints, hacking for key scrubbing down with water etc, complete all as specified and directed by Engineer in Charge. |
| 3 | M&L for 15mm thick plaster on fair faces of brick work or concrete surfaces,mixed WPC @3% of weight of cement in CM 1:4and finish the surface even and smooth without using extra cement, complete all as specified and directed by Engineer in Charge.Note :- Water Proofing compound shall be measured and paid separately under appropriate Item. |
| 4 | Supply only Integral waterproofing compound, complete all as specified and directed by Engineer in Charge. |
| 5 | M&L for 15mm thick cement plaster in CM (1:6) on fair faces of brick or concrete surfaces and finishing the surface even and smooth (without using extra cement) etc, complete all as specified and directed by Engineer in Charge. |
| 6 | M&L for 5mm thick cement plaster 1:3 on fair faces of brick work or concrete surfaces in ceiling and finishing the surface even and smooth (without using extra cement) etc, complete all as specified and directed by Engineer in Charge. |
| 7 | Demolition of brick or stone boulder masnory, built in cement mortar including all quoins, arches, pillars,Man Holes, Septic Tanks, Soakage wells etc, but excluding ashlar facing, dressed stonework and percast concrete articles, complete all as specified and directed by Engineer in Charge. |
| 8 | M&L for brick work with subclass ‘B’ bricks, (locally available best quality) straight or curved on plan to any radius in half brick thick wall, built in cement mortar (1:4), complete all as specified and directed by Engineer in Charge. |
| 9 | M&L for Brick work with subclass B bricks, staright or curved on plan exc 6.00 mtr mean redius, biult in 1:6 cement mortar, complete all as specified and directed by Engineer in Charge. |
| 10 | M&L for 15mm thick plaster on fair faces of brick work or concrete surfaces, in CM 1:4 and finishing the surface even and smooth without using extra cement, complete all as specified and directed by Engineer in Charge. |
| 11 | M&L for complete removal of existing treatment from plastered surface of wall by using electric sand paper grinder, washing, rubbing down and stopping of existing treatment including cleaning of mortar drops, smoke soot, moulds, moss, effloresence salts, trading oil, greasy spots etc and preparation of plastered surface finally rubbed and smooth with sand paper, complete all as specified and directed by Engineer in Charge. |
| 12 | M&L for preparing new plastered or old decorated surface of wall, concrete surface and applying two or more coat of 100% premium acrylic exterior emulsion paintshaving VOC less than 50 gm/ltr and UV resistance as per IS 15489-2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon additives applying @ 1.43 litre/10 Sqm over and including priming coat of exterior primer of same make applied @ 0.90 litre/10 Sqm as per sample approved by GE, complete all as specified and directed by Engineer in Charge. |
| 13 | M&L for applying two coats of oil bound distemper over a coat of primerover already prepared surface of brick or concrete wall, complete all as specified and directed by Engineer in Charge. |
| 14 | M&L for 3mm thick wall care putty on wall and finishing the surface even and smooth by rubbing sand paper, complete all as specified and directed by Engineer in Charge. |
| 15 | M&L for applying three coats of white wash over already prepared surface of brick or concrete wall, complete all as specified and directed by Engineer in Charge. |
| 16 | Dismantling Floor, Hearth or Wall Tiling including Cement Mortar Bedding (but not backing) and removing debris, etc. to Outside MD/AF Land, complete all as specified and directed by Engineer in Charge. |
| 17 | M&L for Non Skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm in Flooring, set and jointed in Neat Cement Slurry and pointed in White/Coloured Cement, laid over and including 15mm thick Screed or Screed Bed in Cement Mortar 1:4, complete all as specified and directed by Engineer in Charge.Note: Cost of Screed Bed will deem to be included in the Quoted Unit Rate. |
| 18 | M&L for Coloured Glazed Ceramic Tiles 350x250x7 mm/ 450x300x7mm thick in Vertical Surface i.e. Dado, Skirting,etc., set and jointed in Neat Cement Slurry and pointed in White or Colour Cement to match the Tiles, laid over and including 10mm thick Screed or Screed Bed in Cement Mortar 1:4, complete all as specified and directed by Engineer in Charge.Note: Cost ofrendering will deem to be included in the Quoted Unit Rate. |
| 19 | M&L for vitrified coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.36 Sqm, in Flooring, set and jointed in Neat Cement Slurry and pointed in White/Coloured Cement, laid over and including 15mm thick Screed or Screed Bed in Cement Mortar 1:4, complete all as specified and directed by Engineer in Charge.Note: Cost of Screed Bed will deem to be included in the Quoted Unit Rate. |
| 20 | Demolition Stone Slabs and/or Tiles of any description or thickness in Floors, Aprons, etc. laid, bedded and pointed in Cement Mortar and removing debris, etc. to Outside MD/AF Land, complete all as specified and directed by Engineer in Charge. |
| 21 | M&L for 18-20 mm thick Granite (of any type) work (table rubbed and polished) as in steps, jambs, pillars, window- cills, cooking platforms, working table and like over 20 mm thick screed bed or bedding layer in cement mortar (1:4), including pointing in white cement (1:2) using marble dust with admixture of pigment to match withshade of granite, complete all as specified and directed by Engineer in Charge. |
| 22 | Taking up or down Steel Tubing 15mm bore (dia) with Fittings/ Connections, complete all as specified and directed by Engineer in Charge. |
| 23 | M&L for Re-Fixing Steel Tubing 15mm bore (dia) and Fittings in new or old position, (Serviceable Pipes and Fittings obtained from Item here-in-before) after cleaning inner and outer surfaces of Pipes by using of Wire Brush including provision of new GI Fittings (as required), complete all as specified and directed by Engineer in Charge. |
| 24 | M&L for Galvanised Tubes 15mm bore (dia), \"medium grade\", with all Fitting and fixed complete to Walls and Ceilings or laid in Floors, complete all as specified and directed by Engineer in Charge. |
| 25 | Taking up or down Steel Tubing 20mm bore (dia) with Fittings/ Connections, complete all as specified and directed by Engineer in Charge. |
| 26 | M&L for Re-Fixing Steel Tubing 20mm bore (dia) and Fittings in new or old position, (Serviceable Pipes and Fittings obtained from Itemhere-in-before) after cleaning inner and outer surfaces of Pipes by using of Wire Brush including provision of new GI Fittings (as required), complete all as specified and directed by Engineer in Charge. |
| 27 | M&L for Galvanised Tubes 20mm bore (dia), \"medium grade\", with all Fitting and fixed complete to Walls and Ceilings or laid in Floors, complete all as specified and directed by Engineer in Charge. |
| 28 | M&L for Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring, etc, and making good, cutting not exc 10 cm girth in brick wall, complete all as specified and directed by Engineer in Charge. |
| 29 | S&F of Rotational moulded polyethylene water storage tanks 500 ltr capacity (cylindrical vertical with closed top) Three layers, hoisted and fixed in position including dismantling/lowering down of unserviceable water tank, complete all as specified and directed by Engineer in Charge. |
| 30 | S&Fof Ball Valve 20mm dia (minimum Weight 210 Gram), high pressure of PTMT with Epoxy coated Aluminium Rod and High density Plastic Ball, screwed for Iron Pipe, complete all as specified and directed by Engineer in Charge. |
| 31 | S&F in repairss Gun Metal Gate Valve 20mm bore (dia) with Iron Wheel Headincluding Flange, screwed both Ends for Iron Pipe, complete all as specified and directed by Engineer in Charge. |
| 32 | S&F in repair 15 mm dia Brass CP wall mixer for mixing hot & cold water screwed down for iron pipe and fixed, complete all as specified and directed by Engineer in Charge. |
| 33 | S&F in repairs Vitreous China White Wash Down Water Closet Pan (Pedestal Pattern) with Trapincluding seat cover and Fixing Bolts and Making Good to Floor/ disturbed surfaces, complete all as specified and directed by Engineer in Charge. |
| 34 | S&F in repairs health faucet fixing in 15mm bore (dia) pipe etc, complete all as specified and directed by Engineer in Charge. |
| 35 | S&F in repairs toilet paper holder of brass, chromium plated fixed to walls with chromium plated (CP) brass screws, complete all as specified and directed by Engineer in Charge. |
| 36 | S&F in repairs for mirror cabinet ofmin size 430x330 mm with openable door shutteras approved by GE, complete all as specified and directed by Engineer in Charge. |
| 37 | S&F in repairs 75mm dia PVC (SWR) floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) and Making Good to Floor/ disturbed surfaces, complete all as specified and directed by Engineer in Charge. |
| 38 | S&F in repairs Flush pipe of polyethylene of low or high density of PVC, 32 mm dia and make a proper connection with water closet and low level cistern with leak proof, complete all as specified and directed by Engineer in Charge. |
| 39 | S&F in repairs PVC Flushing Cistern 10 Litre capacity White, Low Level, Valveless, Syphonic Action type with Inlet, Ball Valve, Float and Handle, a pair of Cast Iron Brackets Erecting Stand duly painted including cutting and pinning in Ends, Making Good Disturbed Surfaces in Cement Mortar 1:3, complete all as specified and directed by Engineer in Charge. |
| 40 | S&F in repairs Mirror 600x450mm in size, Beveled Edge of Selected quality Glass, mounted on 6.0mm thick Commercial Plywood, fixing with Brass Chromium Plated Knobs/Spacers 25mm to 30mm size (One Each in Corner), complete all as specified and directed by Engineer in Charge. |
| 41 | S&F in repairs Vitreous China Wash Hand Basin 550x400mm in size, White (Flat Back) with Brass Chromium Plated Waste Fitting 32mm bore (dia) and PVC Waste Pipe 32mm bore (dia) including a Pair of Cast Iron Brackets Brackets Erecting Stand duly painted including cutting and pinning in Ends, Making Good Disturbed Surfaces in Cement Mortar 1:3, complete all as specified and directed by Engineer in Charge. |
| 42 | S&F in repairs Pillar Tap 15mm bore (dia), Cast Copper alloy with Capstan Heads, Chromium Plated, screwed down high pressure, with or without lettered \"Hot\" or \"Cold\" with long screwed Shanks and Fly-nuts, screwed for Iron Pipe, complete all as specified and directed by Engineer in Charge. |
| 43 | S&F in repairs 15 mm bore Stop Valve chromium plated with long shank and cup (concealed type) ,cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union, complete all as specified and directed by Engineer in Charge. |
| 44 | S&F in repairs Angle Valve 15mm bore (dia), Cast Copper Alloy, Chromium Plated, screwed down, high pressure, screwed both Ends for Iron Pipe with Wall Flange, complete all as specified and directed by Engineer in Charge. |
| 45 | S&F in repairs PVC Connection Pipe 15mm size and 45 Cm in length with Adopter Nuts of PVC, complete all as specified and directed by Engineer in Charge. |
| 46 | S&F in repairs Tubular Towel Rail 20mm dia, Brass Chromium Plated, D-type, 60 Cm long between Flanges with Bracket (one Pair), complete all as specified and directed by Engineer in Charge. |
| 47 | S&F in repairs bib tap 15mm bore (dia), Cast Copper alloy, Fancy type with Flange Chromium Plated, screwed for Iron Pipe or for Brass Ferrule and Chromium Plated Wall Flange, complete all as specified and directed by Engineer in Charge. |
| 48 | S&F in repairs Shower Rose 125mm in size, Brass Chromium Plated, Fancy type with Swivel Joints including Flange and suitable for fixing Steel Pipe 15mm bore (dia) or Union, complete all as specified and directed by Engineer in Charge. |
| 49 | Demolition Cement Concrete (un-reinforced) of any description and any position including removing debris, etc. to Outside MD/AF Land, complete all as specified and directed by Engineer in Charge. |
| 50 | M&L for 75mm thick Cement Concrete 1:3:6 type- (using 40mm graded stone aggregate)as in Plinth Protection, finishing Cement Concrete surface Even and Smooth without using Extra Cement, complete all as specified and directed by Engineer in Charge. |
| 51 | S&F in repairs PVC (SWR) 110mm bore (dia) Soil, Waste and Ventilating Pipe, Single Socketed, in any length with Rubber Ring Joints fixed to Walls/ floor, complete all as specified and directed by Engineer in Charge. |
| 52 | S&F in repairs PVC (SWR) 75mm bore (dia) Soil, Waste and Ventilating Pipe, Single Socketed, in any length with Rubber Ring Joints fixed to Walls/ floor, complete all as specified and directed by Engineer in Charge. |
| 53 | S&F in repairs PVC (SWR) 110mm bore (dia), Bend any type, provided with Access Door, etc. and jointing with Solvent Cement, complete all as specified and directed by Engineer in Charge. |
| 54 | S&F in repairs PVC (SWR) 75mm bore (dia), Bend any type, provided with Access Door, etc. and jointing with Solvent Cement, complete all as specified and directed by Engineer in Charge. |
| 55 | Taking down Chowkhats or frames with shutternot exc 1.5 Sqm each of any description(without taking off shutters from the frames), complete all as specified and directed by Engineer in Charge. |
| 56 | Taking down Chowkhats or frames of any description exc 1.5 sq. m but n exc 4 sq. m each, complete all as specified and directed by Engineer in Charge. |
| 57 | Taking down of shutters of any description exc 1 sq. m and n exc 2 sq. m each, complete all as specified and directed by Engineer in Charge. |
| 58 | S&F of factory made extruded WPC (Wood polymer composite) solid door / window/Ceosetory window & other frame /chowkhat of size 65 x 100 mm comprising of virgin PVC polymer of K Value 58-60 (suspension grade) calcium carbonate and natural fiber (wood powder/rice husk/ wheat husk) and non toxic additives (max toxicity index of 12 for 100 gms) fabricated with mited joints after applying PVC joints after applying PVC solvent cement and secrewed with full body threaded star headed SS screw having min frame density of 750 Kg/Cum screw withdrawal strength of 2200 N (face) and 1100 N (edge) min compressive strength of 58 N/mm2 modules of elasticity 900N/mm2 and resistance to spread of frame of class A cat with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with MS hold fast /lugs/SS dash fastener of required dia and length, complete all as specified and directed by Engineer in Charge. (MS holdfast/lugs or SS dash fastener shall be paid separately)Note: For WPC solid door / window frames min 5mm tolerance in dimension i.e depth and width of profile shall be acceptable , variation in profile dimension on plus side shall be acceptable but no axtra cost on this account shall be made |
| 59 | S&F of factory made single extruded WPC (Wood polymer composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin PVC polymer of K Value 58-60 (suspension grade) calcium carbonate and natural fiber (wood powder/rice husk/ wheat husk) and non toxic additives (max toxicity index of 12 for 100 gms) fabricated with mited joints after applying PVC joints after applying PVC solvent cement and secrewed with full body threaded star headed SS screw having min frame density of 750 Kg/Cum screw withdrawal strength of 2200 N (face) and 1100 N (edge) min compressive strength of 58 N/mm2 modules of elasticity 850N/mm2 and resistance to spread of frame of class A cat with property of being termite/borer proof, water/moisture proof and fire retardant WPC to be laminated with PVC foil of min 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with ss butt hinges of required size with necessary full body threaded star headed counter sunk SS screw, complete all as specified and directed by Engineer in Charge.(Note : Stainless steel butt hinges and necessary SS screw shall be paid separately) |
| 60 | S&F of 100 mm size butt hinges extruded aluminium alloy with galvanised mild steel hinge pinanodised and fixed type B-21, complete all as specified and directed by Engineer in Charge. |
| 61 | S&F of 125 mm size extruded aluminium alloy handles fabricated type anodised, complete all as specified and directed by Engineer in Charge. |
| 62 | S&F of 100 mm aluminium anodised barrel tower bolts of extruded and fixed, complete all as specified and directed by Engineer in Charge. |
| 63 | S&F of factory made extruded WPC (Wood polymer composite) solid door / window/Ceosetory window & other frame /chowkhat of size 65 x 125 mm comprising of virgin PVC polymer of K Value 58-60 (suspension grade) calcium carbonate and natural fiber (wood powder/rice husk/ wheat husk) and non toxic additives (max toxicity index of 12 for 100 gms) fabricated with mited joints after applying PVC joints after applying PVC solvent cement and secrewed with full body threaded star headed SS screw having min frame density of 750 Kg/Cum screw withdrawal strength of 2200 N (face) and 1100 N (edge) min compressive strength of 58 N/mm2 modules of elasticity 900N/mm2 and resistance to spread of frame of class A cat with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with MS hold fast /lugs/SS dash fastener of required dia and length, complete all as specified and directed by Engineer in Charge. (MS holdfast/lugs or SS dash fastener shall be paid separately)Note : For WPC solid door / window frames min 5mm tolerance in dimension i.e depth and width of profile shall be acceptable , variation in profile dimension on plus side shall be acceptable but no axtra cost on this account shall be made |
| 64 | S&F of Flush door shutter 30mm thick solid core construction with block board core and plywood face panels, commercial type both sides, complete all as specified and directed by Engineer in Charge. |
| 65 | S&F of glazed and skelton shutter IInd class hard wood 35mm thick,open rebated and prepare to receive glass, gauge etc. (without sash bars) edge of framing plain chamfered or rounded fitted with cut and mitred beads for securing glassor wire cloth, complete all as specified and directed by Engineer in Charge. |
| 66 | S&F of 250mm stainless steel sliding door bolt with hasp and staple (bolt type) and fxing clipsof sheet , cast or extruded section and fixing bolts and sliding bolts of extruded section, complete all as specified and directed by Engineer in Charge. |
| 67 | S&F of floor door stopper of size 140mm of aluminium alloy body and tongue, anodised with hard drawn steel spring ficed in floor, complete all as specified and directed by Engineer in Charge. |
| 68 | S&F of mild steel 300mm ordinary rat tail rod pattern springs, including roller and roller plate, complete all as specified and directed by Engineer in Charge. |
| 69 | S&F of galvanised mild steel wire cloth 0.56mm nominal dia of wire and avg width of aperture 1.18mm and fixed with tinned tack or galvanised wire staple, complete all as specified and directed by Engineer in Charge. |
| 70 | S&F of powder coated anodised aluminium frame for door, window, ventilator partition with one or more rebates including joining cleat for fixing etc, complete all as specified and directed by Engineer in Charge. |
| 71 | S&F of powder coated anodised aluminium window and ventilator shutters side hung/sliding type without sash bars, aluminium section weighing 0.55 kg/m including necessary joining cleat glazing clips rubber neoprene packing, anodised aluminium snap beading screw, anodised aluminium fitting such as peg stays 150mm long (1 No) hinges type B-21 100mm long (2 No) suitable handle (1 No) etc, complete all as specified and directed by Engineer in Charge. |
| 72 | Taking down aluminium Chowkhats or frames with shutterexc 1.0 Sqm but n.exc 2.0 Sqm each of any description(without taking off shutters from the frames), complete all as specified and directed by Engineer in Charge. |
| 73 | S&F of Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 withinimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineerin-charge, complete all as specified and directed by Engineer in Charge. |
| 74 | S&F of sheet glass 5.5mm thick ordinary quality and glazing with oil putty/any type of beading in square /rectangular in each pane, complete all as specified and directed by Engineer in Charge. |
| 75 | S&F of figured glass 4mm thick pin head type and glazing with oil putty square n exc 0.5 sqm in each pane, complete all as specified and directed by Engineer in Charge. |
| 76 | S&F in repairs Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long, complete all as specified and directed by Engineer in Charge. |
| 77 | S&F of coat hooks of six pegs made out of stainless steel 45 cm long (as per sample), complete all as specified and directed by Engineer in Charge. |
| 78 | Dismantling wrought iron or mild steel work of any description not otherwise provided, complete all as specified and directed by Engineer in Charge. |
| 79 | S&F of framed work such as grills, gratings, stc with ends of bars shouldered and/or riveted or forged into spikes; framed guard bars barred iron doors, ladders framed balusters; walk ways; railing; framework or water tanks and similar work cconforming to Fe-290, Gde-E-165, complete all as specified and directed by Engineer in Charge. |
| 80 | M&L for preparation of new steel surfaces of any description not otherwise described over 10 cm width or grith and applying two coat of synthetic channel paint over a coat of red oxide primer exposed to view surfaces, complete all as specified and directed by Engineer in Charge. |
| 81 | Dismantling brick tiles or terracing tiles single layers on roof, complete all as specified and directed by Engineer in Charge. |
| 82 | Demolition of mud in roofs, any thickness including plastering/pcc padding and leaping (where full thickness removed or only a part thereof), complete all as specified and directed by Engineer in Charge. |
| 83 | Roughening surfaces of old concrete floor by picking,sweeping clean and washing down with water to remove dust etc including dismantling existing membrane, complete all as specified and directed by Engineer in Charge. |
| 84 | Brushing neat cement slurry with 3.0 kg of cement per sqm, complete all as specified and directed by Engineer in Charge. |
| 85 | M&L for providing cement concrete type B0, 1:2:4(using12.5 mm graded stone aggregate) for providing slope, roof kerbs or mud stops rounded or chamfered edges, complete all as specified and directed by Engineer in Charge. |
| 86 | M&L for 10mm thick plastering in cement mortar 1:4, laid on roof, mixed with water proofing compound when concrete is green, as per manufacturere instructions and finishing the surface even and smooth without using extra cement, complete all as specified and directed by Engineer in Charge.Note -Water proofing compound shall be measured and paid separately. |
| 87 | M&L for APP based polymeric membrane of minimum 3 mm thick and minimum weight not less than 3.0 Kg/sqm, reinforced with polyster non woven fabric matt (weight not less than 150 gm/sqm), laid with forced application over roof surface with a coat of hot blown bitumen conforming to IS-3384-1965 of grade 85/25 @ 1.2 kg/Sqm at bottom of the membrane as bonding material, including one coat of aluminium paintcomplete all as per manufacturer\"s instructions, complete all as specified and directed by Engineer in Charge. |
| 88 | M&L for post constructional anti termite treatment along the external and internal wall below concrete or masonry apron or below tiles using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron, complete all as specified and directed by Engineer in Charge. |
| 89 | M&L for post constructional anti termite Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cementmortar 1:2 (1 cement: 2 coarse sand) to match the existing floors, complete all as specified and directed by Engineer in Charge. |
| 90 | M&L for Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, complete all as specified and directed by Engineer in Charge. |
| 91 | M&L forColoured Chequred cement concrete tiles 20cm x 20 cm x 25 mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and pigment, complete all as specified and directed by Engineer in Charge. |
| 92 | M&L for sand cushning 25mm thick for interlocking tiles, complete all as specified and directed by Engineer in Charge. |
| 93 | M&L for factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required, complete all as specified and directed by Engineer in Charge. |
| 94 | SCH \"A\" PART - I (BUILDING WORK E/M PORTION) |
| 95 | Taking down carefully copper/ aluminium point wiring (light fan socket or power) complete along with fittings such as switches, ceiling roses, Pendants regulators Tube fittings and other Kits & fittings/conduitfromsurface /wall . Removing the material from work site and making good the disturbed portion/ surface of wall/ floor/ ceiling etc by using cement mortar and colour/ white wash to match with the existing surface / location, complete all as specified and directed by Engineer in Charge.Note:- Serviceable fitting / fixtures will be reused in the work. |
| 96 | Taking down un-serviceable main switch, DB’s insulators, DB for MCB etc of any type and any capacity and further disposal including making good the disturbed surface and matching the colour of wall with the existing colour wash / paint/ distemper wherever required (as per the existing ), complete all as specified and directed by Engineer in Charge. |
| 97 | Taking down ceiling fan of any descriptions, servicing and repairs of fans as required, fixing back, connecting and testing the fanfor its satisfactory functionincluding making good the disturbed surface and matching the colour of wall with the existing colour wash/ paint/ distemper wherever required (as per the existing), complete all as specified and directed by Engineer in Charge. |
| 98 | S&F of exhaust fans steel body AC single phase 230/ 240 V of size 300 mm sweep with louver, complete all as specified and directed by Engineer in Charge. |
| 99 | Taking down elect water heater of any descriptions, servcing and repairs of geyseras required, fixing back, connecting and testing the geyser for its satisfactory functionincluding making good the disturbed surface and matching the colour of wall with the existing colour wash / paint / distemper wherever required (as per the existing), complete all as specified and directed by Engineer in Charge. |
| 100 | M&L for point wiringwith FRLSPVC insulated unsheathed multi-stranded copper conductor 1.5 Sq.mm (nominal area) single core cable 1100 Volt grade drawninand including rigid non metallic concealed PVC Conduit of suitable size (not less than 20 mm)on wall , surface of ceiling with all fittings, such as tee, bend, elbow, socket etc including pressed steel sunken boxes(Terminal boxes) with earth dolly,duly galvanised, with white shade frame & cover plate of suitable module for modular switch / or sockets including FRLSPVC insulated unsheathed stranded copper conductor 1.5 Sq.mm (nominal area ) single core cable as earth continuity conducter to common earth and connected to earth dolly, complete all as specified and directed by Engineer in Charge.Notes:-(i) Cost of Pressed steel Terminal Boxes and modular Top cover plate shall be included in point wiring. (ii) Wiring shall be done as per colour code in IS for phase, neutral and earth.(iii) Cost of Eye/bottle thimbles used for connection in switches/sockets & MCBs in DBs shall deemed to be included in the unit rate quoted for this item. |
| 101 | All as per described in item no-2.06 but, One light/fan point controlled by one 1-way switch. |
| 102 | All as per described in item no-2.06 but, One3/5 pin socket outlet, 5 Amp on independent board. |
| 103 | All as per described in item no-2.06 but, One3/5 pin socket outlet, 5 Amp on same board. |
| 104 | All as per described in item no-2.06 but, One bell /buzzerpoint controlledby one push button on independent board. |
| 105 | M&L for point wiring with FRLSPVC insulated unsheathed multi-stranded copper conductor 2.5 Sq.mm (nominal area) single core cable 1100 Volt grade drawninand including rigid non metallic concealed PVC Conduit on wall , surface of ceiling with all fittings, such as tee, bend, elbow, socket etc including pressed steel sunken boxes(Terminal boxes) with earth dolly,duly galvanised, with white shade frame & cover plate of suitable module for modular switch / or sockets including FRLSPVC insulated unsheathed stranded copper conductor 2.5 Sq.mm (nominal area ) single core cable as earth continuity conducter to common earth and connected to earth dolly, complete all as specified and directed by Engineer in Charge.(i) Cost of Pressed steel Terminal Boxes and modular Top cover plate shall be included in point wiring.(ii) Wiring shall be done as per colour code in IS for phase, neutral and earth.(iii) Cost of Eye/bottle thimbles used for connection in switches/sockets & MCBs in DBs shall deemed to be included in the unit rate quoted for this item. |
| 106 | Dismantling / Taking down existing unserviceable sub main wiring from batten / conduit of any size all as directed. Removing the material from work site and making good the disturbed portion/ surface of wall/ floor/ ceiling etc by using cement mortar and colour/ white wash to match with the existing surface / location, complete all as specified and directed by Engineer in Charge.. |
| 107 | M&L for sub main surface wiring with PVC insulated unsheathed copper conductor cable of size 6 Sqmm single core through concealed rigid nonmetallicPVC conduit of suitable size (Not less than25mm dia)inwall and surface of ceiling including 6 Sqmm PVC insulated unsheathed copper conductor cable for continuous earthing form main earth dolly includingmakinggoodthedisturbedpotionofwall, complete all as specified and directed by Engineer in Charge.Note:- Two run of 6 Sqmm copper cable one run of 6 Sqmm copper cable and PVC conduit will be measured as a single length. |
| 108 | S&F Switch Modular type, 6 Amp, 240 Volts , one way, complete all as specified and directed by Engineer in Charge. |
| 109 | S&F Switch Modular type, 16 Amp,240 Volts , one way, complete all as specified and directed by Engineer in Charge. |
| 110 | S&F Socket outlet, Modular type, 6 Amp, complete all as specified and directed by Engineer in Charge. |
| 111 | S&F Socket outlet, Modular type, 6&16 Amp, complete all as specified and directed by Engineer in Charge. |
| 112 | S&F Bell Push, Modular type, 6 Amp, complete all as specified and directed by Engineer in Charge. |
| 113 | S&F Fan regulator, modular type electronic step type, complete all as specified and directed by Engineer in Charge. |
| 114 | S&F ceiling rose surface bakelite two to three terminal 65x50 mm, complete all as specified and directed by Engineer in Charge. |
| 115 | S&F in replacement Tube light fittings LED type 1x20 Watt4 ft long incl LED tube rod and incl 3 core flexible wire 0.75 Sqmm copper cable, complete all as specified and directed by Engineer in Charge. |
| 116 | S&F of LED bulk head 10 W, complete all as specified and directed by Engineer in Charge. |
| 117 | S&F of bellding dong operating on AC 230 volt single phase, complete all as specified and directed by Engineer in Charge. |
| 118 | S&F of MCBDB SPN8 Waywith acrylic double door, complete all as specified and directed by Engineer in Charge.ted. |
| 119 | S&F of flushing in wallMCB distribution board verticalTPN 4 way 415 Volts AC double door type sheet steel phosphotised powder painted with bus bar neutral earth barincluding provision of MCB TPN, FP 100 Ampconforing to IP 43as incomer, complete all as specified and directed by Engineer in Charge. |
| 120 | S&F of MCCB 4 pole100Amp 415 voltwith breaking capacity of 16 KA, complete all as specified and directed by Engineer in Charge. |
| 121 | S&F of MCB SPN 240V 40 Amps C series 10 KA, complete all as specified and directed by Engineer in Charge. |
| 122 | S&F of MCB SP 240V 6 to 32 Amps C series 10 KA, complete all as specified and directed by Engineer in Charge. |
| 123 | Taking Down the KWH meteralong with wooden board/DB after removingall electricalconnection, complete all as specified and directed by Engineer in Charge. |
| 124 | Refixing&connecting the same or newserviceableKWH energy meterafter wiring, complete all as specified and directed by Engineer in Charge. |
| 125 | Taking down old U/S LT UG cable of any size from trenches/pipe/floor/walls, complete all as specified and directed by Engineer in Charge. |
| 126 | Supply,laying jointing cable XLPEinsulatedPVC shetahtedstrip wire armoured1100 volt4 core 25 sqmm multi stranded aluminiumconductor laid in trenches/wall/ducts etcincluding necessary fixing arrangement such as cable lugs glands etc completeafter removing/taking out extg unsvcable to the entire satisfaction, complete all as specified and directed by Engineer in Charge. |
| 127 | Excavation in trenches n.exc 1.5 mtr deep and n.exc 1.5 mtr wide getting out soil, complete all as specified and directed by Engineer in Charge. |
| 128 | Returning filling in including spreading leveling, watering and well ramming in layers, complete all as specified and directed by Engineer in Charge. |
| 129 | Removing excavated soil to a distance not exc. 50 mtr and depositing where, complete all as specified and directed by Engineer in Charge. |
| 130 | Supply and spreading dry sand in trenches for cushioning of cable, complete all as specified and directed by Engineer in Charge. |
| 131 | Supply and laying reinforced precast concrete cable cover Class LV, Type I, flat, size 250 mm x 150mm x 40mm, complete all as specified and directed by Engineer in Charge. |
| 132 | S&F of HDPE pipe of size50mmdia, complete all as specified and directed by Engineer in Charge. |
| 133 | M&L for earthing complete withgalvanisedsteel earth plateelectrode 600x600x6mm thick burieddirectlyin ground(earth pitnot less than2 mtr deep belowground levelwith top edgwof the platenot less than 1.4 mtr belownormal ground level, connected earth wire 4 sqmm by means ofbolts nutscheck nutsand washersof galvanisediron or steelall as shownin electrical plateNo 5 connectedto earthingtest pointall as specifiedor indicated includingPCC pitin PCC(1:3:6) type C-1 cast ironframe50mm thickpre castRCC(1: 1 1/2:3)nominal mixcover slabreinforcedwith 8 mmdia mild steeldeformed bar15cc and suitable handleof 10 mm Diaround barincluding necesaryexcavationearth workin soft/loose soiland disposalof spoilto a distancen.exc 50m and funnelwithwatering pipewire meshcopper lugsetc GI protectionpipe of size 15 mm boreincluding testing, complete all as specified and directed by Engineer in Charge. |
| 134 | M&L for sub main surface wiring with PVC insulated unsheathed copper conductor cable of size 4 Sqmm single core through concealed rigid nonmetallicPVC conduit of suitable size (Not less than25mm dia)inwall and surface of ceiling including 10 Sqmm PVC insulated unsheathed copper conductor cable for continuous earthing form main earth dolly includingmakinggoodthedisturbedpotionofwall, complete all as specified and directed by Engineer in Charge.Note :- Two run of 4 Sqmm copper cable one run of 4 Sqmm copper cable and PVC conduit will be measured as a single length. |
| 135 | S&F of Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20Amp,240V, complete all as specified and directed by Engineer in Charge. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail