| 1 | Taking down cement or cement lime plaster of any description and any thickness on brick ,concrete or stone walls, etc including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed by Engineer in Charge. |
| 2 | M&L for rendering 15 mm thick cement plaster in CM (1:4) on fair faces of brick or concrete surfaces and finishing the surface even and fair etc, complete all as specified and directed by Engineer in Charge. |
| 3 | M&L for rendering 5 mm thick cement plaster in CM(1:3) on fair faces ofconcrete surfaces in ceiling, complete all as specified and directed by Engineer in Charge. |
| 4 | M&L for rendering 15 mm thick cement plaster in CM (1:6) on fair faces of brick or concrete surfaces and finishing the surface even and fair etc, complete all as specified and directed by Engineer in Charge. |
| 5 | M&L for rough cast plaster on brick wall consisting under coat of cement and sand mortar (1:4) not less than 10mm thick and while it is still in plastic state the rough cast mixture consisting of crushed stone or fine gravel mixed with coarse sand and cement in the ratio 1:1:1 shall be applied and finish even, complete all as specified and directed by Engineer in Charge. |
| 6 | M&L for complete removal of existing treatment from walls, pillars, cornices upto plaster surface by electric sand paper grinder, washing, rubbing down and stopping of existing treatment including cleaning of mortar drops, smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots etc and preparation of plasteredsurfaces finally rubbed and smooth with sand paper and applying two coat of premium quality exterior emulsion paint over priming coat of exterior primer, complete all as specified and directed by Engineer in Charge. |
| 7 | M&L for preparation new wall surfacefor applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces, complete all as specified and directed by Engineer in Charge. |
| 8 | M&L for prepration of new plastered surfaces of Ceiling and applying three coats of white wash on Ceiling, complete all as specified and directed by Engineer in Charge. |
| 9 | M&L for Preparation of new plastered surfaces of walls and applying two coats of oil bound distemper acrylic, white or tinted over a coat ofprimer, complete all as specified and directed by Engineer in Charge. |
| 10 | M&L for Complete removal of existing treatmentand preparation of old plastered /unplastered surfaces of Ceiling and applying three coats of white wash on Ceiling, complete all as specified and directed by Engineer in Charge. |
| 11 | M&L for Complete removal of existing treatmentand preparation of old plastered /unplastered surfaces of walls and applying three coats of white wash, complete all as specified and directed by Engineer in Charge. |
| 12 | M&L for Complete removal of existing treatment andpreparation of old plastered surfaces of walls and applying two coats of Oil bound distemper acrylic, white or tinted over a priming coat of same make on wall surfaces, complete all as specified and directed by Engineer in Charge. |
| 13 | M&L applying 1.5 avg mm thick wall care putty on walls, including making surface even and smooth using sand paper before applying Priming coat, complete all as specified and directed by Engineer in Charge. |
| 14 | Demolition of stone slabs and tiles of any description or thickness in floors aprons etc laid bedded and pointed in any mortar, complete all as specified and directed by Engineer in Charge. |
| 15 | M&L for 25 mm thick cement concrete 1:2:4, Type B1 (using 20 mm graded stone aggregate), as in sub base of floor, complete all as specified and directed by Engineer in Charge. |
| 16 | M&L for 100 mm thick cement concrete 1:2:4, Type B2 (using 40 mm graded stone aggregate), as in sub base of floor, complete all as specified and directed by Engineer in Charge. |
| 17 | M&L for vetrified tiles 9 to 10 mm thick light shade (square/ rectangular) polished, area of each tile not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM (1:6) for laying floor finishes, complete all as specified and directed by Engineer in Charge. |
| 18 | M&L for vetrified tiles 9 to 10 mm thick light shade (square/ rectangular) on vertical surfaces as in skirting set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick cement plaster in CM 1:4 to receive vertical tiles, complete all as specified and directed by Engineer in Charge. |
| 19 | Demolition of cement concrete in ground floors and paving n exc 15 cm thickness (below or above ground level) and removal of debries from MD land, complete all as specified and directed by Engineer in Charge. |
| 20 | M&L for machine cut kota stone slab flooring 18-20mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab over 15mm thick screed bed of CM1:4 including rubbing and polishing, complete all as specified and directed by Engineer in Charge. |
| 21 | M&L for machine cut kota stone slab14-16 mm thick in riser of steps ,skirting, dado and pillar laid over cement screed and cement slurry including 10mm thick cement plaster 1:3 CM to receive kota stone and jointedrubbing and polishing, complete all as specified and directed by Engineer in Charge. |
| 22 | Demolition of Brickwork or stone/ boulder masonary, built in cement mortar or cement lime mortar, complete all as specified and directed by Engineer in Charge. |
| 23 | M&L for brick work with subclass B bricks, straight or curved on plan exc 6 m mean radius , buit in cement mortar (1:6), complete all as specified and directed by Engineer in Charge. |
| 24 | M&L for 75 mm thick Plain Cement Concrete 1:3:6, type C-1 (using 20mm graded stone aggregate) as in plinth protectionfinishing cement concrete surface even and fair without using extra cement, including making construction joint at a interval not exceeding 2.00 m and at each corner and filled with sealing compound with grade A(normal) in 25/30, complete all as specified and directed by Engineer in Charge. |
| 25 | Taking down Aluminium chowkats & shutters without taking offshutters from the frame, size of openingexc. 1.5 sqm but not exc 4 Sqm each, complete all as specified and directed by Engineer in Charge. |
| 26 | S&F of Powder coatedaluminium frame for doors, windows, ventilators, partations with one or more rebates including joining cleat for fixing etc, complete all as specified and directed by Engineer in Charge. |
| 27 | S&F of Powder coated aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, mortice locks anodised aluminum snap beading screws etc, complete all as specified and directed by Engineer in Charge. |
| 28 | S&F of Powder coated aluminium decorative grill of size of mesh 50mmX50mm fixed with doors, window for safety of glass etc, complete all as specified and directed by Engineer in Charge. |
| 29 | Supply only sheet glass 6.3 mm thick ordinary qualityin square/rectangular exceeding .5 Sqm in each pane, complete all as specified and directed by Engineer in Charge. |
| 30 | Supply only 12 mm Pre laminated exterior grade both side laminated board and fixed, complete all as specified and directed by Engineer in Charge. |
| 31 | M&L for Roughening surfaces of old concrete floor by picking,sweeping clean and washing down with water to remove dust etc including dismantling existing membrane, complete all as specified and directed by Engineer in Charge. |
| 32 | M&L for cement concrete type BO, 1:2:4 (using 12.5 mm graded stone aggregate) providing slope, roof kerbs or mud stops rounded or chamfered edges, complete all as specified and directed by Engineer in Charge. |
| 33 | M&L for 10mm thick Screed bed or bedding layer in cement mortar 1:4, laid on roof, mixed with water proofing compound when concrete is green, as per manufacturere instructions, complete all as specified and directed by Engineer in Charge.Note -Water proofing compound shall be measured and paid separately. |
| 34 | Supply only liquid water proofing compound, ISI marked, complete all as specified and directed by Engineer in Charge. |
| 35 | M&L for UV stable single component fibre reinforced elastomeric liquid applied waterproofing membrane having solid content of 55% formulated wih PU hybrid polymers and reinforcing acrylic fibres and having sun reflectivity Index (SRI) of 106. The application of the material should be done in three coat (6 hr gap after each coat) on the substrate, applying first self priming coat at ratio of damp proof ultra and water 3:1 then 2 undiluted coat of damp proof ultra obtaining coverage @1 ltr/10 sqft in three coats. The vital physical and chemical parameters shall be as under. Min elongationat break of 350%, crack bridging ability of 2.5 mm @650 microns thickness, resists positive hydrostatic pressure of up to 10 bars. The material shall be appliied with brush or roller, complete in all respect as per the direction of Engr-in charge/consultant. Also, proper surface preparation along with covingat corners is must, complete all as specified and directed by Engineer in Charge.Note: The work shall be executed by the authorized applicator of the manufacturer only. |
| 36 | Disconnecting existing water tank of exc 500 ltr and not exc 1000 ltr Capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position, complete all as specified and directed by Engineer in Charge. |
| 37 | S&F of rotational moulded polyethylene 1000 Ltrs Capacity water storage tanks(cylindrical vertical with closed top) hoisted and fixed in position in SSR Part-I including ball brass valve, with polythelene float three layer external and internal white and fly nut complete screwed down for iron pipe of 20 mm dia, complete all as specified and directed by Engineer in Charge. |
| 38 | M&L of 20 mm dia tubes medium grade galvanised with all fitting and fixed complete to walls and ceilings or laid in floors, complete all as specified and directed by Engineer in Charge. |
| 39 | S&F of Aluminium (extruded section)Door closer hydraulicallyregulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed, complete all as specified and directed by Engineer in Charge. |
| 40 | Providing & fixing tiled false ceiling ofDesigner tile Ivory painted (High Pressure Steam cured) of 4mm thickness (as per IS : 14862) of size 595x595mm and any one of the design (Cascade or electra) in true horizental level, suspended on inter locking metal grid of hot dipped galvanised steel section (Galvanised @120 grms, both side inclusive and black painted groove on all T webs) consisting of main T runner with suitably spaced joints to get required length and 15x32mm made from 0.30mm thick sheet spaced at 1200mm c/c and croos \"T\" of size 15x32mm made of 0.30mm sheet 1200mm long spaced between main \"T\" at 600 mm c/c toform a grid of 1200x600mm and secondary cross \"T\" of length 600mm and size 15x32 mm made of 0.30mm thick sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x22x0.40mmand laying false ceiling tiles in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \"T\" runners to be suspended from ceiling using GI soffit cleats fixed to existing RCC lintel with dash fasteners, GI adjustable rods of 3mm dia with galvanised Butterfly level clips, spaced at 1200mm c/c along main \"T\", bottom exposed width of 15mm of all \"T\"\" sections of 3mm dia GI wire shall be pre-painted with polyester paint and black painted groove at center of size 4mm depth and 4.5mm width, all complete at all heights as per direction of Engineer-in-Charge. |
| 41 | Dismantling of post or struts (wood or steel or RCC) any section incl taking embeded portion and making good disturbed ground embeded in concrete, complete all as specified and directed by Engineer in Charge. |
| 42 | Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface, complete all as specified and directed by Engineer in Charge. |
| 43 | M&L for Plain Cement Concrete 1:3:6(using 40 mm graded stone aggregate) as in foundation filling and mass concrete for fixing RCC/ any fencing posts, complete all as specified and directed by Engineer in Charge. |
| 44 | S&F of MS angle as in iron posts and struts, gates, flat & round bars in fencing including cutting tops to shape as directed, drilling holes, notching for wire, bolting etc and similar works like MS flat iron fillets confirming to Fe-290 Gde E-165, complete all as specified and directed by Engineer in Charge. |
| 45 | S&F of roundbars 10 mm dia and over, cut to length, bent to shape as required incl cracking bending hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia, complete all as specified and directed by Engineer in Charge. |
| 46 | S&F of mild steel screw bolt 5 to 10 mm dia (machine made) with hexagonal head at one end and screwed the other, screwed end to be fitted with two washer and hexagonal nut, length notexc 5 cm, complete all as specified and directed by Engineer in Charge. |
| 47 | S&F of 3mm dia PVC coated galvanised mild steel chain link fencing of mesh size 50x50 mm fixed with straining bolts including line wire any mesh size andany type of stabdards, rails, straining bolts etc.including provision of binding wire,weight exc 2 kg, complete all as specified and directed by Engineer in Charge. |
| 48 | M&L for preparation of new or previously untreated steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed by Engineer in Charge. |
| 49 | Surface excavtion not exc. 30 cm deep and averaging 15cm deep and getting out in any type of soil, complete all as specified and directed by Engineer in Charge. |
| 50 | M&L for 15 mm thick Cement plaster in CM (1:4) on fair faces of brick work or concrete surfaces and finishing the surface even and fair etc including applying two coat of cement base paint over and a coat of primer after preparation of new plastered surfaces, complete all as specified and directed by Engineer in Charge. |
| 51 | M&L for Hardcore of gauge not exc. 63 mm, deposited, spread and leveled in layers not exc. 15 cm thick, watered and rammed to a true surface using broken stone or boulders, complete all as specified and directed by Engineer in Charge. |
| 52 | M&L for 75 mm thick Plain Cement Concrete type D2, 1:4:8(using 40 mm graded stone aggregate) as in sub bases, finished even & rough to receive finishing layer, etc, complete all as specified and directed by Engineer in Charge. |
| 53 | M&L for 100 mm thick Plain Cement concrete type D-2, 1:4:8 (using 40mm graded stone aggregate) as in sub base to flooring, complete all as specified and directed by Engineer in Charge. |
| 54 | M&L for 40mm thick Cement Concrete 1:2:4 type B1 (using 20mm graded stoneaggregate) as in floor topping of hard standing/floor finished even and smoothwithout using extra cement PCC shall be laid in alternate bays in panels of size, complete all as specified and directed by Engineer in Charge. |
| 55 | M&L for cement concrete type C-2, 1:2:4 (using 40mm graded stone aggregete) as in foundation and mass concrete, complete all as specified and directed by Engineer in Charge. |
| 56 | S&F of Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated in Fe-290 (Gde E165)etc, complete all as specified and directed by Engineer in Charge. |
| 57 | M&L for steel work in tubular post, trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St-240, complete all as specified and directed by Engineer in Charge. |
| 58 | S&F of 0.50 mm thick pre-painted galvatume alumininum zinc coating GI based corrugated steel sheet of olive green colour having tensile strenght of 550 Mpa as in roof covering /Cladding to wall fixed with self tapping screws, complete all as specified and directed by Engineer in Charge. |
| 59 | S&F of Pre-painted galvalume aluminum zinc coating GI basedPlainsteelsheet 0.50mm thick of olive green colourhaving tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tappingscrews, complete all as specified and directed by Engineer in Charge. |
| 60 | S&F of Rolled sections as in post, main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors;fixed with angle cleats or other connecting plates confirming to Fe-410W (GdeE-250) quality A, complete all as specified and directed by Engineer in Charge. |
| 61 | S&F of Rooftrusses(framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) confirming to Fe-410 Gde 250 quality A including distance pieces, cleats etc, complete all as specified and directed by Engineer in Charge. |
| 62 | S&F of Plates (plain or chequered) channels,squarecutor notched (ordinaryand countersunk) forming holes, with riveted, bolted or welded attachmentconfirming to Fe-410 Gde 250 quality A including distance pieces, cleats etc, complete all as specified and directed by Engineer in Charge. |
| 63 | S&F of Mild steel bolts. purpose made. with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end tobefittedwith washers and one hexagonalor square nutexc 30cm long of dia neck exc 12mm n exc 20mm, complete all as specified and directed by Engineer in Charge. |
| 64 | M&L for preparation of new steelsurface of any description over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer, complete all as specified and directed by Engineer in Charge. |
| 65 | S&F of Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of olive green colour having tensile strength of 550 Mpa as in roof covering/cladding towall, fixed with self tapping screws, complete all as specified and directed by Engineer in Charge. |
| 66 | S&F of Hand rails, half round or other steel section or core for woodenhand-rail straight portion,drilled and countersunk for balusters running bars, for doors, balusters,nosingtosteps includingembedinginconcrete and screwing etc. wind ties for roofincluding securing bolts, complete all as specified and directed by Engineer in Charge. |
| 67 | Demolition of cement concrete (un-reinforced) in ground floor and paving thickness not exc. 15cm (below or above ground level), complete all as specified and directed by Engineer in Charge. |
| 68 | M&L for machine pressed precast concrete coloured interlocking paver blockwith grey cement and pigment, any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 grade laid over and including 25mm thick sand cushion, complete all as specified and directed by Engineer in Charge. |
| 69 | M&L for Providing and laying at or near ground levelfactory made kerb stone of M-25 grade cementconcrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), includingmaking joints with or without grooves(thickness of joints except at sharp curveshall not to more than 5 mm), includingmaking drainage opening whereverrequiredincluding required excavation and removing to out side defence land, complete all as specified and directed by Engineer in Charge. |
| 70 | S&F of 110 mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors, complete all as specified and directed by Engineer in Charge. |
| 71 | M&L for point wiring complete with ISI marked1.5 SqmmPVC insulated multistranded single core cable with copper conductor (FRLS) 1100 volts grade drawn through and including PVC rigid conduit 20 mm or higher dia ISI marked as required at site including conduit accessories such as Junction Boxes, Inspection Covers etc,concealed/surface type on stone/brick masonry walls, roofs, floors etc by means of saddles and clamps etcincluding PVC gang boxes as required at site for concealed/surface conduit wiring and modular plates & covers as required at site for housing switches sockets, regulators etc. including providing of 1.5 Sqmm PVC insulated multistranded unsheathed FRLS copper conductor as earth continuity conductor and connecting to common earth dolly all as specified for and connecting up complete for the following:-One light point controlled by one, one way switch. |
| 72 | M&L for point wiring complete with ISI marked1.5 SqmmPVC insulated multistranded single core cable with copper conductor (FRLS) 1100 volts grade drawn through and including PVC rigid conduit 20 mm or higher dia ISI marked as required at site including conduit accessories such as Junction Boxes, Inspection Covers etc,concealed/surface type on stone/brick masonry walls, roofs, floors etc by means of saddles and clamps etcincluding PVC gang boxes as required at site for concealed/surface conduit wiring and modular plates & covers as required at site for housing switches sockets, regulators etc. including providing of 1.5 Sqmm PVC insulated multistranded unsheathed FRLS copper conductor as earth continuity conductor and connecting to common earth dolly all as specified for and connecting up complete for the following:-One ceiling fan/exhaust fan point controlled by one way switch 6 Amps. |
| 73 | M&L for point wiring complete with ISI marked1.5 SqmmPVC insulated multistranded single core cable with copper conductor (FRLS) 1100 volts grade drawn through and including PVC rigid conduit 20 mm or higher dia ISI marked as required at site including conduit accessories such as Junction Boxes, Inspection Covers etc,concealed/surface type on stone/brick masonry walls, roofs, floors etc by means of saddles and clamps etcincluding PVC gang boxes as required at site for concealed/surface conduit wiring and modular plates & covers as required at site for housing switches sockets, regulators etc. including providing of 1.5 Sqmm PVC insulated multistranded unsheathed FRLS copper conductor as earth continuity conductor and connecting to common earth dolly all as specified for and connecting up complete for the following:-Switch Socket outlet 2/3 pins 6 Ampson independent board. |
| 74 | M&L for point wiring complete with ISI marked1.5 SqmmPVC insulated multistranded single core cable with copper conductor (FRLS) 1100 volts grade drawn through and including PVC rigid conduit 20 mm or higher dia ISI marked as required at site including conduit accessories such as Junction Boxes, Inspection Covers etc,concealed/surface type on stone/brick masonry walls, roofs, floors etc by means of saddles and clamps etcincluding PVC gang boxes as required at site for concealed/surface conduit wiring and modular plates & covers as required at site for housing switches sockets, regulators etc. including providing of 1.5 Sqmm PVC insulated multistranded unsheathed FRLS copper conductor as earth continuity conductor and connecting to common earth dolly all as specified for and connecting up complete for the following:-Switch Socket outlet 2/3 pins 6 Amps on same board. |
| 75 | M&L for point wiring complete with ISI marked 4 SqmmPVC insulated unsheathed multistranded single core cable with copper conductor (FRLS) 1100 volts grade drawn through and including PVC rigid conduit 20 mm or higher dia ISI marked as required at site including conduit accessories such as Junction Boxes, Inspection Covers etc,concealed/surface type on stone/brick masonry walls, roofs, floors etc by means of saddles and clamps etcincluding PVC gang boxes as required at site for concealed/surface conduit wiring and modular plates & covers as required at site for housing switches sockets, regulators etc. including providing of 4 Sqmm PVC insulated multistranded unsheathed FRLS copper conductor as earth continuity conductor and connecting to common earth dolly for 15 Amps switch socket combination, complete all as specified and directed by Engineer in Charge. |
| 76 | S&F of modular fan regulator 120watt 240 V AC two module type, complete all as specified and directed by Engineer in Charge. |
| 77 | S&F of ceiling rose, 3 terminals /PVC/Polycarbonate, isolated body, complete all as specified and directed by Engineer in Charge. |
| 78 | S&F of modular Socket 6A-2/3 pin combined two module type, complete all as specified and directed by Engineer in Charge. |
| 79 | S&F of modular Socket 6A/16A-2/3 pin combined two module type, complete all as specified and directed by Engineer in Charge. |
| 80 | S&F of modular 1 way 6Amp switch 1 module, complete all as specified and directed by Engineer in Charge. |
| 81 | S&F of 1 way 15 Amp switch 1 module, complete all as specified and directed by Engineer in Charge. |
| 82 | S&F of LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder includingLED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and directed by Engineer in Charge. |
| 83 | S&F of led luminaire 600 mm x 600 mm 35/36 watt, 220V AC recessed/Surface mounted type with high efficiency PMMA diffuser soft glare light with LED efficacy of 120 lm/watt electronic driver,suitable for roof ceiling including connecting up with driver three core copper conductor 1.5 sqmm size, complete all as specified and directed by Engineer in Charge. |
| 84 | M&L for sub main wiring with 2 runs of 4 Sqmm single core PVC insulated unsheathed FRLS cable 1100 Volts grade multistranded with copper conductor drawn through and including non metallic rigid PVC conduit ISI marked 25 mm dia including conduit accessories concealed/surface type on walls, roof,floors etc including one run of 4.0 Sqmm PVC copper conductor as earth continuity wire includingtaking downunserviceable sub main wiring including conduit, complete all as specified and directed by Engineer in Charge. Note : 2 Runs of 2.5 sqmm cable 1 run of 2.5 sqmm cable and 1 run of PVC conduit shall be measured as one unit for the purpose of payment. |
| 85 | All as described in item No.83 here-in-before but with 3 runs 6 sqmmincluding 1 run of 6 sqmm PVC copper conductor FRLS cable as earth continuity wire in not less than 25mm dia PVC conduit.Note : 4 Runs of 6 sqmm cable 1 run of 6 sqmm cable and 1 run of PVC conduit shall measured as one unit for the purpose of payment. |
| 86 | S&F of MCB DB 8 way SPN (double door)sheet metal enclosure factory made suitable for MCB DB\"s 240 voltswith 200 amp rated busbar, neutral & earthing link bar, flush/surface mounting complete including taking down the existing DB of any type & size by removing from existing circuits and refixing the new DBs and circuits, complete all as specified and directed by Engineer in Charge. |
| 87 | S&F of MCB single pole 6-32 Amps working on 240 volts, 50 HZ AC, 10 KA \"C\" curve, complete all as specified and directed by Engineer in Charge. |
| 88 | S&F of MCB SPN 40-63 Amps working on 240 volts, 50 HZ AC, 10 KA \"C\" curve, complete all as specified and directed by Engineer in Charge. |
| 89 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminiumconductor of size 10.0 sq mm 2 core, complete all as specified and directed by Engineer in Charge. |
| 90 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in soft loose soil for laying of underground cable etc, complete all as specified and directed by Engineer in Charge. |
| 91 | Returning, filling in, including spreading, leveling, watering and well ramming in layers each not exceeding 25cm thick using soil, complete all as specified and directed by Engineer in Charge. |
| 92 | Removing excavated surplussoil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point, complete all as specified and directed by Engineer in Charge. |
| 93 | Supply and spreading of natural, clean, dry, river sand in trenches for cable protection / transformer yard/ two pole structure yard, complete all as specified and directed by Engineer in Charge. Note:- Punned thickness only shall be measured for payment purpose. |
| 94 | Supply and laying un-reinforced precast concrete cable cover, class LV, type 1 with peak, size300mm x 180mm x 40mm, complete all as specified and directed by Engineer in Charge. |
| 95 | S&F of Air Circulator fans 230 voltssingle phase oscillating 600 mm sweep suitable for MS pole/Wall mounting, complete all as specified and directed by Engineer in Charge. |
| 96 | M&L for earthing complete with galvanised steel earth plate electrode 600x600x6.3mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia of minimum 15m length by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 in SSR PART-I connected to earthing test point all as specified or indicated including provision of earthing lead protection pipe, PCC earth pit with cover, excavation & earth work, testing, complete all as specified and directed by Engineer in Charge. |
| 97 | S&F of LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant, complete all as specified and directed by Engineer in Charge. |
| 98 | S&F of LED High bay light 140 watt 230 V AC with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant, complete all as specified and directed by Engineer in Charge. |
| 99 | S&F of GI tubing 15mm dia light grade for protection of GI earth wire/Cable, complete all as specified and directed by Engineer in Charge. |