| 1 | B/R WORKS |
| 2 | Surface excavation n.exc (not exceeding) 30cm deep and averaging 15cm deep and getting outin SOFT/LOOSE soil complete, all as specified. |
| 3 | Excavating in post holes (or similar holes) each n exc0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50m and making good surface in SOFT/LOOSE soil complete, all as specified. |
| 4 | Excavation in trenches n. exc 1.5 m wide for foundations, laying cables/ pipes etc. not exceeding 1.5 m deep and getting out in SOFT/LOOSE soil complete, all as specified. |
| 5 | Returning filling in including spreading, levelling, watering and well ramming in layers notexceeding 25cm thick complete all as specified. |
| 6 | Removal of excavated surplus spoil to a distance n. exc. 50m and depositing where directed at level not exceeding 1.5 m above the starting point complete all as specified. |
| 7 | PCC type D-2 (1:4:8), using 40 mm graded stone aggregates as in filling foundation & mass concrete, complete all as specified. |
| 8 | Cement concrete, type B-1 (1:2:4), using 20 mm graded stone aggregates as in cills, steps, seicmic and other similar band, plinth courses, lacing courses , copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angle and throating upto 60cm heightall as specified. |
| 9 | Brick work using bricks as specified in PS clause 5.1, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar (1:6), complete all as specified. |
| 10 | Rolled mild steel work in tubular trusses including special shaped washer & gusset plate etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 gradeSt.-240, complete all as specified. |
| 11 | Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm of any colour hving tensile strength of 550 Mpa as in roof coverng/ cladding to wall, fixed with self tapping screws, comlete all as specified. |
| 12 | Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm of any colour hving tensile strength of 550 Mpa as in roof coverng/ cladding to wall, fixed with self tapping screws, comlete all as specified. |
| 13 | 100 mm thick, cement concrete type D-2, 1:4:8 using 40 mm graded stone aggregate, finished even & rough, as in sub floors, complete all as specified. |
| 14 | 60 mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of shape approved by GE, made by table vibratory method using PU mould, laid in required pattern over and including 50mm thick compacted bed of coarse sand, compacting through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete |
| 15 | Rendering 15 mm thickon fair faces of brick work or concrete surfaces, finished even and fair on walls in cement mortar (1:6),complete all as specified. |
| 16 | Two coats of cement base paint on new wall surfaces including preparation of surfaces complete all as specified. |
| 17 | Two coats of synthetic enamel paint over & including a coat of red oxide primer oversteel & iron (new) surfaces of any description, not otherwise described, over 10 cm in width or girth, including preparation of surfaces complete all as specified. |
| 18 | E/M WORKS |
| 19 | Point wiring with multi-stranded copper conductor, single core, FRLSH PVC insulated and unsheathed cable, including FRLSH PVC insulated unsheathed stranded copper conductor single core cable as earth continuity conductor to common earth and connected to earth dolly, with and including GI terminal modular boxes made out of 1.2mm thick MS sheet concealed in wall modular metal flush box & including modular cover plate with framehaving necessary cutting for fixing switches/ socketscomprising the following: - |
| 20 | One light point controlled by one switch or one fan point controlled by one switch & fan regulator etc. or for bell/buzzer with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit not less than 20mm dia all as specified. |
| 21 | One Socket outlet three pin, 6 Amp, on the same board, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, all as specified. |
| 22 | One socket outlet three pin, 6 Amp, independent, with 1.5 Sq. mm (nominal area) cable &1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit not less than 20mm dia all as specified. |
| 23 | One socket outlet three pin, 6/16 Amp, independent, with 2.5 Sq. mm (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit not less than 20mm dia all as specified. |
| 24 | Pointwiring complete 2.5 sqmm single core, FRLSH PVCinsulated, sheathed, 1100V grade copper multistranded conductor drawn through and including in stove enamelled steel conduit on walls, surface on roofs and beam/iron structure etc including FRLSH PVC insulated copper earth continuity conductor 2.5 Sqmm cable connected to common earth dolly including steel terminal modular boxes made out of minimum 1.2 mm thick MS sheet concealed in walls modular metal flush box and including modular cover plate with frame as requires at site for housing the switches, sockets regulators etc all as specified and dircted for one switch/light/bell point controlled by one switch. Note : Two Highbay light controlled by one MCB & average length of wiring is minimum 14 metre. and height of hanger is 20 meter min. |
| 25 | NOTES: (a) Switch(es) & socket(s) shall be measured & paid for separately under respective item of Schedule \"A\". (b) GI boxes shall be fixed flush to walls in position with cement mortar (1:4). |
| 26 | Flame proof point wiring with using approved colour coding as per IS, with Zero halogen flame retardent (HFFR), smoke free, non toxic, non corrosive installation cable2.5 Sqmm nominal area HFFRinsulated unsheathed multistranded copper conductor cable in and including ERW rigid 25 mm dia conduit stove enamelledconcealedfor one light point / Fan point / 6Amp multipurpose switch socket with and including necessary conduit acessories like flame proof junction box(es), bend(s), reducer(s) and unions etc, independent for one light point controlled by one (MCB) including 1.5 Sqmm nominal area PVC insulated unsheathed multistranded copper conductor cable for earth wire to common earth and connected to earth dolly complete all as specified. |
| 27 | Flame proof point wiring with using approved colour coding as per IS, with Zero halogen flame retardent (HFFR), smoke free, non toxic, non corrosive installation cable 4.0 Sqmm nominal area HFFRinsulated unsheathed multistranded copper conductor cable in and including ERW rigid 25 mm dia conduit stove enamelled concealed conduitfor one light point / Fan point / 16Amp multipurpose switch socket with and including necessary conduit acessories like flame proof junction box(es), bend(s), reducer(s) and unions etc, independent for one light point controlled by one (MCB) including 4 Sqmm nominal area PVC insulated unsheathed multistranded copper conductor cable for earth wire to common earth and connected to earth dolly complete all as specified. |
| 28 | Flame proof weather proof rotary switch, single pole on & off with cable termination box in LM6, 16 Amp rating,ON/FF type, 230 volt AC certified by CMRS for Group IIA & IIB complete including compression glands complete all as specified. |
| 29 | Flame proof weather proof rotary switch-socket and plug combination in LM6, three pin (two pole earth) with cable termination enclosure box, 16-25 Amp rating, 250 volt complete. |
| 30 | Switch modular type single pole one way, 6 Amp, 1 module complete all as specified. |
| 31 | Switch modular type single pole one way, 16 Amp, 1 module complete all as specified. |
| 32 | Socket outlet multipurpose having provision for 2&3 pin, 6 Amp, 2 Module complete all as specified. |
| 33 | Socket outletmultipurpose having provision for two-in-one 3 pin 6 Amp & 3 pin 16 Amp,2 Module complete all as specified. |
| 34 | Ceiling rose, surface bakelite, 65 x 50mm, three terminals complete, all as specified. |
| 35 | PVC insulated sheathed cable with standard aluminium conductor 1100 Volts grade flat twin core service cable of size 4 sqmmwith latest amendement ISI mark completed all as specified and directed. |
| 36 | Sub main wiring (with approved colour coding as per IS) with single core FRLSH PVC insulated flexible stranded copper conductor 1.1 KV grade (main cable: number of runs as indicated below along with single core FRLSH PVC insulated flexible stranded copper conductor 1.1 KV grade for earthing in conduits, with and including rigid non metallic PVC medium duty concealed conduit not less than 25mm dia complete all as specified for the following: - NOTES: (i)For payment purposes, total runs of main cable (each run of one running metre) as mentioned above and one run (one running metre) of earth cable shall be considered together as \"1 RUNNING METRE\" |
| 37 | 2 runs of 4 Sq. mm main cable + 1 run of 4 Sq. mm earth cable |
| 38 | 2 runs of 6 Sq. mm main cable + 1 run of 6 Sq. mm earth cable |
| 39 | 2 runs of 10 Sq. mm main cable + 1 run of 6 Sq. mm earth cable |
| 40 | Sheet metal enclosure for DB for fixing MCB’s, isolators etc., having IP-43 protection, suitable for surface and flush mounting, IN REPLACEMENTcomplete all as specified comprising the following: |
| 41 | SPN, 2 way with 200 Amp rated bus bar, 240 V, double door type. |
| 42 | SPN, 8 way with 200 Amp rated bus bar, 415 V, double door type |
| 43 | MCB suitable for 240 volt AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 kA, \"C\" curve type of rating6 to 32 Amp,complete all as specified. |
| 44 | MCB of double poles suitable for 240 volt AC \"C\" curve type supply,and rupturing capacity not less than 10 kA, \"C\" curve type of rating 40-63 Amp complete all as specified |
| 45 | Taking down ceiling fan for painting & including painting with synthetic enamel paint by spraying and refixng it in existing or other location, connecting up with 1.5 sqmm flexible cable in flexible conduit from ceiling rose to fan complete all as specified and directed. |
| 46 | Flame proof tube LED light fitting 2x 16 watt with & including LED tube 16W each, CMRI certified recommended suitable for gas/vapur of IIA & IIB and Zone 1& 2 havingIP-65 protection with die cast aluminium housing with heat resistant toughened glass with driver, holder, connector etc complete suitable for fixation on wall/roof , including connecting up with three core suitable size twisted flexible copper conductor with complete. |
| 47 | LED tube lights fitting 1x 20W, 220V AC, 4 ft, decorative box type made of aluminim die cast housing with high out put diffuser,driver,LED lamp including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete, IN REPLACEMENT all as specified and directed. |
| 48 | LED luminaire 600mm x 600mm , 35/36 watt, 220 V AC recessed type with high efficient PMMA diffuser soft glare free light complete with driver holder & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor case of suitable size complete, IN REPLACEMENT all as specified and directed |
| 49 | LED high bay light 200 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp IN REPLACEMENT,complete all as directed. |
| 50 | Flame proof exhaust fan 450 mm sweep with blades, frame and louvers, AC single phase, 230 V AI die cast body, IP 66 protectiontemperature class-T6, CIMFR certified recommended suitable for gas/vapur of IIA & IIB and Zone 1& 2 havingIP-66 protection, complete all as specified and directed |
| 51 | Electric water heater storage type steel body withinner tank (as per manufacturer instruction)and heating element upto 2 kw capacity 25 litre, BEE 5 star rated complete with all accessories such as safety valve, thermostate, NRV, steel PVC connector for hot water etc including electric connection with 3 core PVC insulated, seathed. stranded copper conductor cable/flexible chord and one no 15 amp 3 pin plug topcomplete all as specified.. |
| 52 | Commercial Air curtain unit for prevention of dust and conditioned air losses, singlephase, 220 V, 50HZ, made out of MS/CRCA sheet of minimum thickness 18 guage finished with two coats of red oxide primer and final coat of synthetic enamel paint (oven baked ) with MS-CRC 18 guage square perforated suction grills, Aluminium alloy fans consisting of 02 Nos single phase electric motor Wall mounted type, nozzles etc, suitable for Door opening size 64\"x84\" complete with fittings and accessories so as to produce 1-1.5m/sec air velocity at floor level fordoor opening, & commissioning and testing as specified. |
| 53 | Flame proof split unit indoor/outdoor air conditioner of capacity 2.0 TR operating voltage supply 230 Volts AC, single phase, 50 Hz, complete all as specified and directed including following:-Indoor Unit:- Indoor unit mounted on wall, kept in hazardous area of split type cooling unit comprising cooling motor, condesing coil with copper tubes and aluminium blue fins duly coated with specialist chemical to prevent refrigerant leakage, GI body with MS structure will be used to integrate thecomponents of cooling unit.OUtdoor Unit:- Outdoor unit kept in no hazardous area. Flame proof control panel: Main incomer MCB, connector, overload relay, temperature controller with RTD sensor, sequntial timer for protection of compressor and condensing motor, cooling motor. The classification area Zone I &II, gas groups IIA &IIB, IIC with dust protection zone 21 & 22.Note:- (i) All mounting stands & channels/bracket required for mounting the indoor and outdoor unit shall be provided by the contractor.(ii) Indoor unit noise shall be less than than 50Db and outdoor unit noise shall be less than 90Db.(iii) Rate for drainage pipe upto drain, extra copper tubes are included in quoted rates. |
| 54 | Shifting of split AC with proper commsionning and testing charging of gas and servicing complete all as specified and directed. |
| 55 | Earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GIstrip 25x4 mm as earthing lead by means ofGI or steel bolts/nuts/washers, protected by 15 mm bore GI light grade pipe. Earth plate shall be surrounded by alternate layer of charcoal or coke and common salt 15 cm thick all around bottom and top. 20 mmbore GI light grade pipe for watering and including funnel, wire mesh, RCC cover, reinforced with 8 mm dia TMT bars @ 75 mm C/C both ways with mild steel handle 12 mm dia, using round bar, PGI funnel with wire mess & frame, PCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) as in earthing pit including necessary excavation & earth work, all as specified, IN REPLACEMENT & shown in electrical plate No. 3 of MES Schedule Part – I.Note:- (i)PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) The unit rate includes earthing lead & protection pipe upto 7.5 metre from top of earth plate.(iii) Earth resstance shall be less than 3 ohm. In case the test results are not found less than 3 ohm, complete earthing shall be redone by the contractor without any extra cost to Govt. |
| 56 | Demolition and Dismantling work |
| 57 | Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete with batten, casing caping of MS or and PVC conduit on surface or concealed, including switches, ceiling roses, pendants, regulators, sockets, mild steel terminal boxes etc., removing materials and making good disturbed surfaces due to taking down etc. to the entire satisfaction of Engineer-In-Charge, complete all as specified. |
| 58 | Taking down carefully copper/aluminium sub main wiring complete, including existing batten/conduit consealed/surface etc., removing materials and making good disturbed surfaces due to taking down etc. to the entire satisfaction of Engineer-In-Charge, complete all as specified. |
| 59 | Note : Amount ofcredit for retrieved materials is mentionedin Sch of credit of tender documents in pdf form which will be deducted while acceptance of tender offline. |