| 1 | SH:- Repair and Maintenance |
| 2 | Wood Work and Aluminium Work |
| 3 | Dismantling doors, windows and clerestory windows (steel or wood) shutters including chowkhats, architrave, hold fasts etc complete and stcking within 50m lead.a) Of area 3 Sq.m. and below |
| 4 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and panelling to be paid for separately) : For fixed portion.1.3 Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) @ 1.79 KG per meter(75x40x3)MM |
| 5 | For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required (Fittings shall be paid for separately).Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron). |
| 6 | Providing and fixing 12mm thick Pre-laminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminium doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge.Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side. |
| 7 | Providing and fixing panelled, glazed or panelled and glazed shutters for doors, windows and clerestory windows including aluminium butt hinges with necessary screws.4.2 With float glass panes of 5.5 mm thickness. sqm 1499.20 |
| 8 | Roof Work |
| 9 | Dismantling GI sheet roofing including ridges, hips, valleys and gutters etc and stacking the material within 50 m lead. |
| 10 | Providing and fixing Durashine zinc-Aluminium alloy coated (TATA Bluescope building product) sheet roofing fixed with necessary fasteners and lapping method as described by the manufacturer inclusive of cutting hoisting and fixing complete, excluding the cost of purlins, rafters and trusses.Details of cost for 179.655 Sq.m.Laying and fixing 20 sheets in 3 row require Overall Sheet area of 20 x 3 x 3.05 x 1.072 plus 3% wastages = 202.061 Sqm After H & L laping as per manufacturer\"s specification, effective Area Measurable will be 20 x 3x 2.95 x1.015 = 179.655 Sqm |
| 11 | Providing and fixing 2.50 cm thick approved local wood eaves boards 23 cm wide with necessary mouldings etc. |
| 12 | Dismantling wooden boarding in lining of walls and partitions excluding supporting members but including stacking within 50 m lead.a) Up to 10 mm thick Sqm 34.60 |
| 13 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of anglecleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mmcentre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm withtapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixingperimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mmcentre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes ,finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :(d) Fully Perforated Gypsum Plaster Board of size 1200 x 2400x12.5 mm having approx. 15 % perforated area with perforation size and pattern as approved by the Engineer-incharge and as per manufacturer\"s specification, with all 4 side tapered and backed by acoustical tissue with NRC value not less than 0.60 |
| 14 | Flooring |
| 15 | Demolishing cement concrete 1 : 4 : 8 or leaner mix including disposal of material within 50 m lead. |
| 16 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., completeb) Size of Tile 600x600 mm |
| 17 | Chequered terrazzo tiles 22 mm thick with marble chips of sizes upto 6mm in floors on 25mm thick bed mortar 1 : 3 (1 cement : 3 coarse sand) jointed with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing complete:a) Light shades using white cement |
| 18 | Painting |
| 19 | Removing old paint or polish with paint remover of approved brand and manufacture and preparing surface. |
| 20 | Wall painting (one or more coats) with plastic emulsion paint of approved brand and manufacture on old work to give an even shade. |
| 21 | Painting two or more coats (excluding priming coat) with superior ready mixed paint for wood work of approved brand and manufacture in all shades on new work to give an even shade. (Eaves Boards) |
| 22 | Cement Work |
| 23 | Repairs to plaster in patches of 2.50 Sq.m. and under including cutting the patch to proper shape and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 m lead.a) With cement mortar 1 : 4 (1 cement : 4 fine sand) |
| 24 | Drainage Internal |
| 25 | Construction of cement concrete drain 30 cm wide and 23 cm deep in cement concrete 1 : 3 : 6 (1 cement : 3 sand : 6 hard graded stone chips/shingle 40 mm and down gauge) 8 cm thick on sides and bottom and plastering on all exposed surfaces with 12 mm thick cement mortar1 : 3 (1 cement : 3 fine sand) including shuttering complete.a) With cement mortar 1 : 4 (1 cement : 4 fine sand) |
| 26 | Fire Safty |
| 27 | Automatic Fire Alarm System |
| 28 | Carriage Charge |
| 29 | SH:-C/o RCCDrain(10 Mtr. Details) |
| 30 | Excavationfor Structures (Earth work inexcavationoffoundationof structures as per drawing and technicalspecification,includingsetting out, construction of shoringand bracing, removal of stumps and other deleteriousmatter, dressingof sidesandbottom andbackfillingwith approved material.)I. Ordinary soilManual Meansi. upto 3 m depth (without de-watering) |
| 31 | PCC 1:3:6 in Foundation (Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.) |
| 32 | Plain/Reinforced cement concrete in open foundation complete as per drawing and technical specificationsC) RCC Grade M20 case i) using concrete mixture |
| 33 | Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 34 | Supplying, fittingandplacingun-coatedMildsteel reinforcement complete in foundation as per drawing and technical specification |
| 35 | Centring and shuttering including strutting proping etc. and removal of form work for:a) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. |
| 36 | b) Suspended floors, roofs, etc |
| 37 | 12 mm cement plastering 1:4 ( 1 cement : 4 fine sand) |
| 38 | Neat cement Punning |
| 39 | Add cost for Carriage of Materials |
| 40 | SH:- C/o Public Toilet |
| 41 | EARTH WORK |
| 42 | Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock), lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required, into plinth sides offoundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus soil as directed within a lead of 50m. |
| 43 | Extra for every additional lift of 1.50 m or part thereof for earth work in all soils including shingles, small size boulders upto 30 cm size but excluding saturated soil and rock. |
| 44 | Re-filling excavated earth in foundations and plinth etc. in 15 cm layer including ramming and watering etc. complete. |
| 45 | CEMENT CONCRETE WORK |
| 46 | Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering in :a) Foundations and plinth |
| 47 | Construction of cement concrete drain 30 cm wide and 23 cm deep in cement concrete 1 : 3 : 6 (1 cement : 3 sand : 6 hard graded stone chips/shingle 40 mm and down gauge) 8 cm thick on sides and bottom and plastering on all exposed surfaces with 12 mm thick cement mortar1 : 3 (1 cement : 3 fine sand) including shuttering complete. |
| 48 | Making plinth protection 50 mm thick of cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 stone aggregate using 20 mm nominal size) over 75 mm bed of stone ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finsihing the top smooth. |
| 49 | RCC WORK |
| 50 | Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcementin :a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 51 | Reinforced cement concrete in walls (any thickness) including attached pillasters, buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in :a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 52 | Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 53 | Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 54 | Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 55 | Centring and shuttering including strutting, propping etc and removal of form work for :a)Foundation, footings, bases of columns etc. and mass concrete. |
| 56 | b) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. |
| 57 | c)Columns, pillars, posts and struts etc. |
| 58 | d)Lintels, beams, girders, bressumers and cantilevers etc. |
| 59 | e)Suspended floors, roofs, landings shelves and their supports balconies and chajjas (3.5m height). |
| 60 | Reinforcement of RCC work including bending, binding and placing in position complete. a) Tar/TMT steel |
| 61 | BRICK WORK. |
| 62 | Brick work with best available local bricks in foundation and plinth in cement mortar 1:3 (1 cement : 3 fine sand). |
| 63 | Extra for brick work with best available local bricks in superstructure above plinth level up to floor two level. |
| 64 | Half brick masonry (with best available local bricks) in cement mortar 1:3 (1 cement : 3 coarse sand) in foundation and plinth. |
| 65 | Extra for half brick masonry in superstructure above plinth level and up to floor two level. |
| 66 | WOOD WORK. |
| 67 | Providing approved best available local wood (Class - B II) work in frames of doors, windows clerestory windows and other frames, wrought framed and fixed in position. |
| 68 | Supplying and fixing factory made panelled shutters made out of best available hard wood for doors including panelling with panels 12 mm thick commercial veneered teak wood particle boards (Phenyle Bonded) 3 layers flat pressed including applying one coat of approved wood primer.a) 40 mm thick including anodized aluminum butt hinges with necessary screws. |
| 69 | Providing and fixing best available local wood glazed shutters for doors, windows and clerestory window using 7.5 kg/Sq.m. (3 mm thick glass panes) including black enamelled MS butt hinges with necessary screws.a) 35 mm thick |
| 70 | Providing and fixing 40 x 3 mm flat iron hold fasts 40 cm long including fixing to frame with 10 mm dia bolts, nuts and wooden plugs and embedding in cement concrete block 30 x 10 x 15 cm in 1 : 3 : 6 (1 cement : 3 sand : 6 hard stone chips 40 mm nominal size). |
| 71 | Providing and fixing aluminum butt hinges anodised, transparent or dyed to required color or shade with necessary screws etc complete.(a) 100 x 75 x 4 mm |
| 72 | Providing and fixing aluminum Tower bolts anodized or transparent or dyed to required color or shade with necessaryscrews etc complete.a) 300 x 10 mm |
| 73 | Providing and fixing aluminum Handles anodised transparent or dyed to required color or shade with necessary screws etc complete.(a)100 mm |
| 74 | Providing and fixing aluminum sliding door bolts anodised transparent or dyed to required color or shade with nuts and screws etc complete.a)300 x 16 mm |
| 75 | FLOORING |
| 76 | 40 mm thick red oxide flooring, under layer of 30 mm thick cement concrete 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 12.5 mm nominal size) & top layer of 10 mm thick plaster of cement red oxide mix (using 3.5 kg of red oxide of iron per 50 kg of cement) 1 : 3 (1 cement red oxide mix : 3 coarse sand) finished with a floating coat of neat cement red oxide mix of same proportion. |
| 77 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.d) Size of Tile 2400x1200 mm |
| 78 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., completeb) Size of Tile 600x600 mm |
| 79 | FINISHING |
| 80 | 12 mm cement plaster 1 : 4 (1 cement : 4 fine sand). |
| 81 | 6 mm cement plaster to ceiling 1 : 4 (1 cement : 4 fine sand). |
| 82 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :(a) 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) : 2011 (Board with BIS Certification marks) |
| 83 | Providing two coats of acrylic water based wall putty/ wall filler of Asian Paits/ Berger/ Dulux over concrete/ cement plaster/ brick walls and ceilings both internal and external after removing all the loosely adhering material from the wall/ ceiling surface with the halp of emery stone, putty blade or wire brush, moistening the wall with the help of sufficient quantity of clear water as specified and directed by the department. |
| 84 | Applying one coat of cement primer of approved brand and manufacture on wall surface. |
| 85 | Finishing walls with water proofing cement paint of approved brand and manufacture and required shade on new work (three or more coats) to give an even shade. |
| 86 | WATER SUPPLY |
| 87 | Providing and fixing GI pipes complete with GI fittings and clamps including cutting and making good the walls (internal work).a) 15 mm nominal bore |
| 88 | c) 25 mm nominal bore |
| 89 | Providing and fixing GI pipes complete with GI fittings including trenching and refilling etc (external work).e) 40 mm nominal bore |
| 90 | Providing and fixing brass bib cock of approved quality.a) 15 mm nominal bore |
| 91 | Providing and fixing brass stop cock of approved quality.a) 15 mm nominal bore |
| 92 | Providing and fixing CP brass shower rose with 15 mm or 20 mm dia inlet.a) 150 mm dia |
| 93 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 94 | SANITARY INSTALLATION |
| 95 | Providing and fixing white vitreous china type water closet pedestal (European type WC pan) with seat and lid CP brass hinges and rubber buffers, 12.5 Litres high level CI flushing cistern with fittings RS or CI brackets, galvanized steel telescopic flush pipe with fittings and clamps, 20 GI overflow pipe with specials and mosquito proof coupling of approved municipal design and GI chain and pull complete including painting of cistern and fittings, cutting making good the walls and floors where required.a) WC pan with white plastic seat and lid. |
| 96 | Providing and fixing white vitreous china water closet squating pan (Indian type WC pan) size 580 mm with 100 mm and sand cast iron P or S trap, 12.5 Litre high level CI flushing cistern (of approved make) with fittings RS or CI brackets, 32 mm dia galvanized steel telescopic flush pipe with fittings and clamps 20 mm GI over flow pipe with specials and mosquito proof coupling of approved municipal design and GI chain and pull complete including painting of cistern and fittings, cutting and making good the walls and floors where required.galvanized steel telescopic flush pipe with fittings and clamps, 20 GI overflow pipe with specials and mosquito proof coupling of approved municipal design and GI chain and pull complete including painting of cistern and fittings, cutting making good the walls and floors where required.a) Long Pan patten WC Pan |
| 97 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x 430x 265 mm sizes respectively with CI automatic flushing cistern with fittings, RS or CI brackets standard size galvanized steel flush pipe and spreaders with brass unions and GI clamps complete including painting of cistern and fittings, cutting and making good the walls and floors where required.d) Range of four urinals with 15 Litre CI automatic flushing cistern |
| 98 | Deduct for not providing 32 mm dia MI or CP brass trap. |
| 99 | Deduct for not providing 32 mm dia MI union. |
| 100 | Providing and fixing 600x450 mm bevelled edge mirror or superior glass (of approved quality) complete with 6 mm thick asbestos sheet ground fixed to wooden cleats withCP brass screws and washers. |
| 101 | Providing and fixing CP brass towel rail complete with CP brass brackets fixed to wooden cleadt with CP brass screws (heavy quality).a) 750 x 20 mm size |
| 102 | Providing and fixing toilet paper holder.a) CP Brass |
| 103 | Providing and fixing sand cast iron/ cast iron (spun) soil, waste and vent pipes.a) 100 mm dia |
| 104 | Providing and fixing sand cast iron heel rest sanitary bend.a) 100 mm dia |
| 105 | Providing and fixing sand cast iron single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.a) 100 x 100 x 100 mm |
| 106 | Providing and fixing sand cast iron trap of self cleadnsing design with sand cast iron screwed down or hinged grating with or without vent arm complete including cost of cutting and making good the walls and floors.a) 100 mm inlet and 100 mm outlet |
| 107 | Providing and fixing white vitreous china wash basin with RS or CI brackets painted white 15 mm CP brass pillar taps and CP brass chain with rubber plug 32 mm CP brass waste of standard pattern, 32 mm dia CP brass trap and MI unions complete, including cutting and making good the walls where required.a) Flat back wash basin size 550x400 mm with a pair of 15 mm CP brass pillar taps of heavy quality. |
| 108 | Providing and fixing CP Brass Chain and rubber plug complete for sink or wash basins |
| 109 | Providing and fixing CP brass waste for wash basins and sinks.b) 40 mm dia |
| 110 | Providing and fixing MI fisher union for wash basin and sinks.b) 40 mm dia |
| 111 | Providing and fixing CP Brass or MI trap for wash basin and sinks.b) 40 mm dia |
| 112 | Providing and fixing 100 mm sand cast iron grating for gulley, floors or nahni trap. |
| 113 | Providing and fixing in position 32 mm dia galvanized steel telescopic flush pipe complete including cutting and making good the walls and floors. |
| 114 | Providing and fixing in position 25 mm dia mosquito proof coupling of approved municipal design. |
| 115 | Making soak pit 2.50 m dia 3 m deep with 45 x 45 cm dry brick honeycomb shaft and SW drain pipe 100 mmdia 1.80 m long complete as per standard design. |
| 116 | Providing laying and jointing glazed stone ware pipe grade \"A\" with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. a) 100 mm dia SW pipes |
| 117 | Providing and laying cement concrete 1 : 5 : 10 (1 cement : 5 lime sand : 10 graded stone aggregate 40 mm nominal size) all around SW Pipe including bed concrete 15cm thick as per standard design. a) 100 mm dia SW pipes |
| 118 | Providing and fixing sand cast iron single equal plain junction of required degreea) 100 x 100 x 100 mm |
| 119 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 120 | Add Internal Electrical Connection |
| 121 | Add Cost for Carriage of Materials |
| 122 | SH:- C/o Block Pavement |
| 123 | Clearing and Grubbing Road Land (Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness.)(i) By Manual Means:-A) In area of light jungle |
| 124 | Demolishing cement concrete 1 : 4 : 8 or leaner mix including disposal of material within 50 m lead. |
| 125 | Excavation in Soil by Manual Means. (Excavation for roadway in soil using manual means including loading in truck for carrying of cut earth to embankment site with all lifts and lead upto1000 metres.) |
| 126 | Dry rubbleFlooring |
| 127 | Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1cement : 4 coarse sand : 8 graded stone shingle 40 mm nominal size) excluding the cost of centring and shuttering. |
| 128 | Providing and laying cement concrete 1 : 2 : 4 (1 cement : 2 coarse sand : 4graded stone shingle 40 mm nominal size) excluding the cost of centring and shuttering in a) Foundations and plinth |
| 129 | Providing and laying 60 mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. |
| 130 | Carriage of Materials |