| 1 | EARTHWORK |
| 2 | Earth work in excavation by mechanical means ( Hydraulic excavation)/ manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead upto 50m and lift upto 1.5 m, as directed by the Engineer-in-charge. |
| 3 | All kinds of Soil |
| 4 | Fillingavailableexcavated earth(excludingrock) intrenches, pinth, sidesoffoundationsetc. in layers not exceeding 20 cm in depth, consolidation each deposited layer by rammingand watering, lead upto 50mand lift upto 1.5m. |
| 5 | Supplying and filling in plinth with sandy soil under floors including, watering, ramming consolidating and dressing complete. |
| 6 | CONCRETE WORKS |
| 7 | Providing and laying cement concrete in foundation. Plinth excluding the cost of centering and shuttering - All work upto plinth level : |
| 8 | 1 : 4 : 8 ( 1 cement :4 c/sand : 8 graded stone aggregate. 40mm. nominal size). |
| 9 | RCC WORKS |
| 10 | Providing and laying inpositionready mixed plain cement concreteor site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/ Ordinary Portland/ Portland Slag cement, admixture in recommended proportions as per IS:9103 to accelerate / retard setting of concrete,to improve ductility and workability without impairing strength;including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of Engineer-in-charge; for the follwing grades of concrete. All work upto plinth level: |
| 11 | (a) Concrete of M-25 grade with minimum cement content of330 kg/cum. |
| 12 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15 degree landings, balconies, shelves, chajas, lintels, bands, plain window sills, staircases and spiral staircases upto floor five level excluding the cost of centering, shuttering, finishing and reinforcement with |
| 13 | (a) 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size) |
| 14 | Reinforced cement concrete work in walls (any thickness) i/c attached pillasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level but excluding the cost of centering and shuttering and reinforcement: |
| 15 | (a) 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size) |
| 16 | Reinforcement for RCC work i/c straightening, cutting, bending, placing in position and binding all complete. |
| 17 | (a) Thermo-Mechanically Treated bars |
| 18 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 19 | a) foundations, footings, bases of columns etc. for mass concrete. |
| 20 | b) Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 21 | c) Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 22 | d) Weather shade, chajjas , corbels etc. including edges. |
| 23 | e) Suspended floors, roofs, landings, balconies and access platform |
| 24 | f)Stairs, (excluding landings) except spiral staircase |
| 25 | BRICK WORK : |
| 26 | Brick work in 1st class common burnt clay F.P.S ( non modular ) bricks in foundation and plinth in : Cement motar 1:4 (1cement:4 coarse sand) |
| 27 | Brick work 7cm thick with 1st class common burnt clay F.P.S ( non modular ) bricks incement motar 1:3 (1cement:3 coarse sand) in superstructure above plinth level and upto floor five level. |
| 28 | Wood work : |
| 29 | Providing wood works in frames of doors, windows, clerestory windows & other frames, wrought framed & fixed in position with hold fast lugs or with dash fastener of required dia and length ( hold fast lugs or dash fastener shall be paid for separately : |
| 30 | b) Local best quality Teak wood |
| 31 | Providing and fixing M.S Grills of required pattern in frames of windows etc. with M.S flats, square or round bars etc. including priming coat with approved steel primer all complete. |
| 32 | Fixed to openings/wooden frames with rawl plugs screws etc. |
| 33 | Providing and fixing panelled or paneled and glazed shutters for doors,windowsand clerestory Windows i/c ISI marked M.S.butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for seperately, all complete as per direction of Engineer-in-charge.(a)Local best quality Teak wood. -35 mm thick shutters |
| 34 | Providing and fixing panelled or panelled andglazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling or panelled and glazed shutters 25mm to 40 mm thick : |
| 35 | Float glass panes 4 mm thick glass panes |
| 36 | Providing 40X3mm flat iron hold fast 40cm long i/c fixing to frameswith 10mm dia. Bolts, nuts and wooden plugs and embedding in cement concrete block 30X10X15 cm 1:3:6 mix (1 cement : 3coarse sand: 6 stone aggregate 20mmnominal size). |
| 37 | Providing and fixing ISI marked oxidised M.S sliding door bolts with screws etc. complete.300X16 mm |
| 38 | Providing and fixing ISI marked oxidised M.S tower bolt black finish, (Barrel type) with necessary screws etc. complete :250 X 10 mm |
| 39 | Providing and fixing ISI marked oxidised M.S tower bolt black finish, (Barrel type) with necessary screws etc. complete :200 X 10 mm |
| 40 | Providing and fixing ISI marked oxidised M.S handles conforming to IS:4992 with necessary screws etc. complete: 125 mm |
| 41 | Providing and fixing oxidised M.S hasp and stable(safety type) conforming to IS: necessary screws etc. complete :150 mm |
| 42 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, ( for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 43 | Providing and fixing in position collapsible steel shutters with vertical channels 20xl0x2mm and braced with flat iron diagonals;20x5mm size: with top and bottom rail of T-iron 40x40x6mm with 40mm dia, steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. |
| 44 | FINISHING WORK |
| 45 | 12mm Cement Plaster of mix 1 :3 ( 1 Cem : 3 c/sand) |
| 46 | 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix : 1:3 (1 cement: 3 fine sand) |
| 47 | FLOORING |
| 48 | Providing and lying vitrified floor tiles in different sizes(thickness to be specified by the manufacturerer) with water absorption\"s less than 0.08% and conforming to IS: 15622 make in all colours and shades, laid on 20mm thick cement mortar 1:4(1cement, 4 course sand) including grouting the joints with white cement and matching pigments etc complete. |
| 49 | Size 600X600 |
| 50 | Tile work in skirting, risers of steps and dado (uptp 2cm height) over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry @ 3.3 kg/sqm including pointing in white cement mixed with oigment of matching shade complte. |
| 51 | Marble tiles (polished) Raj Nagar |
| 52 | 8mm thick |
| 53 | Prividing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-charge in skirting, riser of steps and dados over 12mm thick bed of cemewnt motar 1:3 and jointing with grey cement sluury @ 3.3kg per sqm including pointing in whiye cement mixed with pigment of matching shade complete. |
| 54 | PAINTING WORK |
| 55 | Applying priming coat with ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood ) |
| 56 | Providing and applying two coats of fire retardant paint unthinned on cleaned wood/ply surface @ 3.5 sqm per litre per coat including preparation of base surface as per recommendation of manufacturer to make the surface fire retardant. |
| 57 | Providing and applying white cement based putty of average thickness 1mm of approved brand and manufacture, over the plastered wall surfacer to prepare the surface even and smooth complete |
| 58 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface |
| 59 | Finishing wall with Acrylic Smooth exterior paint of required shade:- |
| 60 | New work (Two or more Coat applied @ 1.67 ltr/10 Sqm over and including base coat of water proofing cement paint applied @ 2.20kg,sqm). |
| 61 | Finishing wall with Acrylic Smooth exterior paint of required shade:- |
| 62 | Wall painting with plastic emulsion paint of approved brand and manufacturer to give an even shade |
| 63 | Two or more coats on new work |
| 64 | MISCELLANEOUS |
| 65 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarsesand : 6 graded stone aggregate 20 mm nominal |
| 66 | Providing & laying six course water proofing treatment with bitumen felt over roof consisting of first, third & fifth courses of blown or/& residual bitumen applied hot at 13.61 Kg 11.34 Kg per 9.29 sqm of area respectively second & fourth courses roofing felt type2 grade2 (fibre base self finished bitumen felt) & sixth & final course of stone grit 6 mm & do down size of pea size gravel spread at 0.064 cum per 9.29 sqm i/c preparation of surface etc. complete. |
| 67 | Earth work in excavation in foundation trenches ordrainsi/c. dressing of sides and ramming of bottoms lift upto 1.5m including getting out the excavated soil anddisposalof surplusexcavated soil as directed,within a lead of50m in Hard dense Soil |
| 68 | Fillingavailableexcavated earth(excludingrock) intrenches, pinth, sidesoffoundationsetc. in layers not exceeding 20 cm in depth, consolidation each deposited layer by rammingand watering, lead upto 50mand lift upto 1.5m. |
| 69 | Providing and laying cement concrete in foundation. Plinth excluding the cost of centering and shuttering in |
| 70 | 1:3:6( 1cement:3 coarse sand:6 gradedstone aggregate 20mm nominal size) |
| 71 | 1:4:8( 1cement:4 coarse sand:8 gradedstone aggregate 40mm nominal size) |
| 72 | Brick work in 1st class common burnt clay F.P.S ( non modular ) bricks in foundation and plinth in : Cement motar 1:4 (1cement:4 coarse sand) |
| 73 | Half brick masonry with 1st class common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level upto floor V level in: cement mortar 1:3 (1 cement : 3 coarse sand) |
| 74 | Honey-comb brick work 10/11.4 cm thick with 1st class common burnt clay FP.S. (non modular) bricks in superstructure above plinth level and upto floor V level in cement mortar 1 : 4 ( 1 cement : 4 coarse sand) |
| 75 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15 degree landings, balconies, shelves, chajas, lintels, bands, plain window sills, staircases and spiral staircases upto floor five level excluding the cost of centering, shuttering, finishing and reinforcement with |
| 76 | (a) 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size) |
| 77 | Reinforcement for RCC work including Straightening, cutting, bending,placing in position and binding all complete. |
| 78 | (a) Thermo-Mechanically treated bars. |
| 79 | Providing form work i/c shuttering and centering so as to give a rough finish, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m. And removal of the same for in-situ reinforced concrete and plain concrete work in |
| 80 | a)Foundations,footings bases ofcolumns etc. formass concrete. |
| 81 | e) Suspended floors, roofs, landings, balconies and access platform |
| 82 | Cement concrete flooring 1:2:4 (I cement: 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost Of nosing of steps etc. complete. |
| 83 | 40mm thick with 20mm nominal size stone aggregate.. |
| 84 | 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix : 1:3 (1 cement: 3 fine sand) |
| 85 | Providing and fixing UPVC soil, waste, rain water and vent pipes including all requisite fittings, jointing of pipes & fitting with solvent cement, tenching, refilling & testing of joints complete as per direction of Engineer in charge. |
| 86 | 75 mm dia |
| 87 | 110 mm dia |
| 88 | Supplying and fixing C.I. Cover with frame (for manhole and chambers) |
| 89 | 600x450 mm rectangular C.I. Cover (light duty) 23 kg |
| 90 | Providing and fixing 600x450 mm bevelled cdgoe mirror of superior glass (Of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass scrows and washers complete. |
| 91 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour weighing not less than 105 gms. |
| 92 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. |
| 93 | 600 mm long towel rail with total length of 645 mm,width 78 mm and effective height of 88 mm, weighing, not less than 190 gms. |
| 94 | Providing and fixing wash basin with C.I brackets, 15 mm dia CP Brass single hole basin mixer of approvedquality and make, including painting of fittings and brackets, cutting and making good the walls wherever required :- |
| 95 | a) White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps |
| 96 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with scat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever). conforming to IS : 7231. with all fittings and fixtures complete. including cutting and making good the walls and floors wherever required : |
| 97 | W.C. pan with ISI marked white solid plastic seat and lid |
| 98 | Providing flanged joints to double flanged C.I/D.I pipes and Specials, including testing of joints :100 mm diameter pipe |
| 99 | Providing and Fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fitting, standard size C.P brass flush pipe, spreaders with unions and clamps (all in C.P brass ) with waste fitting as per IS : 2556, C.I trap with outlet grating and other couplings in C.P brass, including painting of fittings and cutting and making good the walls and floors wherever required: |
| 100 | Single half stall urinal with 5 liter P.V.C automatic flushing cistern |
| 101 | Providing and Fixing one piece construction white vitreous china squatting plate with an integral longitudinal flusing pipe, white P.V.C automatic flushing cistern, with fittings, standard size G.I / P.V.C flush pipe for back andC.P brass coupling complete, including painting of fittings and cutting and making good the walls and floods wherever required: |
| 102 | Single squatting platewith 5 liter P.V.C automatic flushing cistern |
| 103 | WATER SUPPLY |
| 104 | Providing and placing on tcrrace (at all floor levels) polyethylene per litre 10.20 water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and tho baso support for tank. |
| 105 | Providing and Chlorinated polyvinyl chloride ( CPVC) pipes aving thermal stability for hot and cold watter supply including all CPVC plain and brass treaded fittings, i/c fixing pipe with clamps at 1.00 m spacing. This includesjoining of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good te same including testing of joints compare as per directiopn of engineer in charge. |
| 106 | 32 mm nominal outer dia Pipes |
| 107 | 25 mm nominal outer dia Pipes |
| 108 | 15 mm nominal outer dia Pipes |
| 109 | Providing and Chlorinated polyvinyl chloride ( CPVC) pipes aving thermal stability for hot and cold watter supply including all CPVC plain and brass treaded fittings. This includesjoining of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good te same including testing of joints compare as per directiopn of engineer in charge. |
| 110 | External works |
| 111 | 32 mm nominal outer dia pipes |
| 112 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete |
| 113 | 25 mm nominal bore |
| 114 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to 1S.8931. |
| 115 | a) 15 mm diameter |
| 116 | Providing and fixing brass bib cock of approved quality |
| 117 | 15 mm nominal bore |
| 118 | Supplying and Fixing water pump to supply water with necessary fitting. |
| 119 | a) 2 HP water pump |
| 120 | (SH-Providing of IEI) |
| 121 | Sub-Head -I (Wiring) |
| 122 | Wiring for light point / fan point/Exhaush Fan point /call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface /recessed steel conduit with modular type switch,phemolic laminated sheet suitable size M.S. box and earthing the point with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc as required. |
| 123 | Group C |
| 124 | Wiring for light point /power point plug with 2x4 sq.mm FR PVC insulated copper conductor single core cable in surface /recessed steel conduit alongwith 1 no.4.sq.mm FR PVC insulated copper conductor single core cable for loop earting etc as required. |
| 125 | Wiring for circuit / sub main wiring alongwith earth wire with following size of FR PVC insulated copper conductor, single core cable in surface /recessed steel conduit as required. |
| 126 | a) 2X1.5.mm² +1x1.5mm² earth wire |
| 127 | b) 2X2.5.mm² +1x2.5mm² earth wire |
| 128 | c) 4X4.mm² +2x4mm² earth wire |
| 129 | d) 4x6mm2+2x6mm2 earth wire |
| 130 | Sub- Head-II |
| 131 | ( Fittings & Accessories) |
| 132 | S/F Recess Mounting LED down Lighter BGSL 0101WH,220223,cast aluminium housing fixed with collimated lens,1x1W white LED mounted on MCPCB ,extruded Al heat sink spring loaded mounting clips, complete with connections etc as reqd. |
| 133 | Supplying, installation testing and commissiong of ceiling fan, capacitor type suitable for low voltage operation including wiring the down rods of standard length (upto 30 cm ) with 1.5 sq.mmFR PVC insulated, copper conductor, single core cable including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. (ISI marked approved) |
| 134 | a) 1200 mm sweep |
| 135 | Supplying, Installation of exhaust fan upto 305 mm sweep in the opening, including marking the holes to suit the size of above fan, making good the damage, connection, testing, commissioning etc. as required. |
| 136 | S/F 1.5 tone capacity split type Air conditioner(Diamond, 3 star , 5G 30, G-SC 18 FD 3 WJH) complete with indo voltage stabilizer Automatic 4 KVA( 140-280 for 1 ton). |
| 137 | Supply and fixxing of following size of PVC casing and capping along with accessories etc. |
| 138 | (a) 20mm |
| 139 | Providing and fixing of lightning conductor finial made of 25mm dia 300mm long copper tube having single prong at top with 85mm dia 3mm thick copper plate i/c holes etc. complete as reqd. |
| 140 | Sub- Head- III |
| 141 | (DB,s & MCB,s) |
| 142 | Supplying and fixing following way, single pole and neutral ( SPN) , sheet steel, MCB disbutribution board ,240 Volts on surface / recess, neutral bus bar, earth bar, din interconnection,s phosphatized and power paintted including earthing etc. as required.( But without MCB/RCCB/Isolator). |
| 143 | a) 8 way Single Door |
| 144 | S/F \"B\" series,SP MCB. Supplying and fixing following 5 amps to 32 amps rating 240 Volts, B series, miniture circuit breaker suitable for lighting and other load of following poles in the existing MCB DB complete with connection, testing and commissioning etc as required. |
| 145 | a) Single Pole and Neutral |
| 146 | S/FDP MCBisolator: Supplying and fixing following rating, double pole,240 volts, isolator in the existing MCB DB complete with connection,testing and commissioning etc. as required. |
| 147 | a)63 amps. |
| 148 | Sub-Head - IV |
| 149 | ( Earthing ) |
| 150 | Earthing with Copper earth plate 600mmx600mmx6mm thick i/c accessories, and providing masonary encloure with cover plate having locking arrangement and watering pipe etc.(but without charcoal or coke and salt ) as required. |
| 151 | Providing and fixing 8 SWG dai G wire on surface of in surface or in recess for loop earthing along with existing surface/recessed conduit/submain wiring /cable,as required. |
| 152 | Sub- Head- V |
| 153 | Switch Gear (Main Switch) Change Over |
| 154 | P/F 400 amp. TPN stand ground on load change over switch (Compact design) 415/500 V including connection etc as reqd. |
| 155 | S/F Bus Bar chamber with 4 strips copper bus bar of length 900mm suitable for 400 amp capacities complete with all accessories i/c connection earthing the body etc. as reqd |
| 156 | Fabrication of control panel board by 16 gauge steel sheet, along with components, wiring all over the panel i/c fixing charge, painting etc. as reqd. |
| 157 | 1. Ammeter 0-200 volts. |
| 158 | 2. Voltmeter 0-500 volts. |
| 159 | 3. Selector Switch for ammeter & voltmeter |
| 160 | 4. Indicator lamp (Digital) |
| 161 | 5. Hinges for panel door. |
| 162 | 6. Panel door locks. |
| 163 | 7. Panel internal power wiring by 40x6mm copper strips. |
| 164 | Supply of 95 sqmm 4CX95sqmm PVC/XLPE insulated heavy duty Al armoured cable 1.1KV grade |
| 165 | Laying of 1no PVC insulated PVC sheathed power cable of 1.1KV grade of size not less than 25 mm sq but not exceeding 120 mmsq direct in groundi/c excavation sand cushioning protective covering and refilling the trench etc as reqd. |
| 166 | Fire fighting and fire hydrants |
| 167 | SITC of Fire Fighting System |