| Sl. No. | Item Description |
| 1 | Removing existing water proofing treatment of any description from roof slabs, cleaning the surface using wire brushes etc, roughening the concrete surfaces picking, sweeping clean and washing down with water to remove dust etc and brushing neat cement slurry with 3.00 kg of cement per Sqm (Where PCC padding is to be provided) complete all as specified. |
| 2 | M & Lfor preparation of old roof surfaces by brooming and watering, cleaning all dust particles and providing PCC (1:2:4) type B-0,(using 12.5 mm graded crushed stone aggregate) with water proofing compound as per manufacturer instruction asinpaddding/ levelling course of average thickness not exceeding 25mmcomplete all as specified and as directed.Note : Water proofing compound will be measured and paid separately. |
| 3 | M&L for water proofing treatment for roof by applying priming coat of epoxy primer with resin and harder in 1:3 ratio with water dilution as per manufacturer instructions, applying two coats of fiber Reinforced Elastomeric Liquid fiber applied water proofing membrane formulated with select elastomeric and resilient acrylic polymers and reinforcing synthetic fibers liquid applied membrane with consumption of 0.93sqm/ltr (each coat). Second coat should be applied once 1st coat becomes dry completely all as specified and directed. Ponding test of the roof surface will be done for 48 hours before and after the roof treatment process to identify the leakage and seepage from the roof surface completeall as specified and directed.Note (a) The work under item 03 shall be carried out by the authorised applicator of Manufacturer by using modern techniques. The contractor shall also furnish warrantly of quality, finish work and effectiveness of waterproofing treatment under this item for a period of not less than 7 years from the date of completion along with manufacturer warrantly of material for the same period. (b) From the taking down, preparation of the surface, Eng-in-Charge shall approv each and every stage before applying finishing coats. |
| 4 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) n. exc 1.5 Sqm each complete all as specified and directed. |
| 5 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exc 1.5 Sqm but not exc 4 sqm each complete all as specified and directed. |
| 6 | S &F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/Ceosetory windows & other Frames/Chowkhat of size 45 x 85 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). |
| 7 | S &F Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 35mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screwwithdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. (Note: stainless steel butt hinges and necessary S S screws shall be paid separately) |
| 8 | S & Fanodised Aluminium alloy sections sliding windows with frames Series-C (20mm) and , 3 track sliding shutters duly fitted with neoprene beading, glazing clips,shutters with tinted glass 5mm thick and stainless steel wire cloth 0.35mm dia and average width of aperture 1.4mm , aluminium alloy handles etc. complete all as specified and directed. |
| 9 | S&Faluminium anodisedventilator with fixed aluminium frame of size 65 x 40 x 1.98mm thick fixed in vertical position with aluminium vertical members andhalf portion to be provided with 4mm thick pin head glass and remaining portion to be louvered using 4mm thick pin head glass and louvered portion covered with stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm incl necessary channel frame work, including rubber gasket and aluminium beading complete all as specified. |
| 10 | S&F 35 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides compete all as directed. |
| 11 | S&F factory made 2nd class hard wood 30 mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed. |
| 12 | Refixing of shutters of in same opening any description exc 1 sq m and n exc 2 sq m each complete all as specified and directed |
| 13 | Refixing of shutters of in same opening any description exc2 sq m each complete all as specified and directed |
| 14 | S & F aluminium alloy handles size 150mm fabricated type anodised completeall as specified and directed. |
| 15 | S&F Aluminium anodised barrel tower bolts of extruded section 200mm long all as specifed and directed. |
| 16 | S&F butt hinges 125mm size, extruded aluminium alloy with galvanised mild steel hinge pin anodised, type B-21 complete all as specified and directed. |
| 17 | S&F 300 mm long aluminium alloy anodised sliding door bolt with hasp and staple (bolt type) and fixingclips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified directed. |
| 18 | M & L for applying one coats of synthetic enamel paint over a coat of red oxide primer including preparation of old steel surface over 10 cm width or girth, not otherwise described complete all as specified and directed. |
| 19 | S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples completeall as specified and directed. |
| 20 | S&F in repair stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples completeall as specified and directed. |
| 21 | M&L preparation of new wood and wood based surfaces of any description not otherwise described over 10 cms width or girth and applying 2 coats of synthetic enamel paint over a coat of pinkprimer all as specified and directed. |
| 22 | M&L preparation of old wood and wood based surfaces of any description not otherwise described over 10 cms width or girth and applying 2 coats of synthetic enamel paint over a coat of pinkprimer all as specified and directed. |
| 23 | Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 24 | M&L for PCC 1:3:6 C-2 (using 40 mm graded crushed stone aggregate) as in plinth protection( 75 mm thick ) laying in alternate ways finished even and smooth without using extra cement all as specified. |
| 25 | Taking down cement or cement lime plaster of any discription on brick or stone walls/ ceilings etc, including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 26 | Brushing neat cement slurry with 3.0 kg of cement per sqm complete all as specified and directed. |
| 27 | M&L for 10 to 12 mm thick smart care ready mix repair plaster with high quality polymer additive and well graded sand and fillers which can be used for plastering ( as per manufacturer instruction ) over exterior surface of wall complete all as specified and directed. |
| 28 | M&L for 10 to 12 mm thick smart care ready mix repair plaster with high quality polymer additive and well graded sand and fillers which can be used for plastering ( as per manufacturer instruction ) over interior surface of wall complete all as specified and directed. |
| 29 | M&L for 5 to 10 mm thick smart care ready mix repair plaster with high quality polymer additive and well graded sand and fillers which can be used for plastering ( as per manufacturer instruction ) over ceiling surfaces complete all as specified and directed. |
| 30 | M&L for newly plastered surfaces of wall and applying two coats of exterior emulsion paint with one coat of primer in normal pattern as per manufactures instructions etc complete all as specified and directed by Engr-in-Charge. |
| 31 | M&L Preparing newly plastered or un plastered surfaces of wall and applying two coats of oil bound distemper with roller application over a chalk whiting over a coat of average 1mm thick wall care putty on new plastered surfaces complete all as specified and directed. |
| 32 | M&L for applying two coats of oil bound distemper with roller on old decorated wall surfaces over 1 mm thick white putty including complete removalof existing treatment with mechanical complete all as specified and directed. |
| 33 | M&L for applying three coats of white wash on ceiling including preparation of new plastered or un-plastered surfaces, complete all as specified and directed. |
| 34 | M&L for applying three coats of white wash on ceiling old surfaces, including preparation of old and new surfaces complete all as specified and directed. |
| 35 | Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc |
| 36 | M&L non skidjoint free coloured tiles (1st quality/ premium quality) 7 to 8 mmthick (square/rectangular) area of each tile exceeding 0.06 Sqm but not exc. 0.11 Sqmas in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 15mm thick screed bed or bedding layer of cment mortar (1:6)complete all as specified and directed.(toilet,bath,kitchen, passage floor) |
| 37 | M&L non skid joint free coloured tiles(1st quality/premium quality) 7 to 8mmthick (square/rectangular) area of each tile exceeding 0.18Sqm but not exc. 0.38 Sqmas in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 15mm thick screed bed or bedding layer of cment mortar (1:6)complete all as specified and directed. (bed room and other room floor) |
| 38 | M & L for non skid ceramic coloured tiles (Ist quality) 7 to 8 mm thick (Square/ rectangular), area of each tile exc 0.18 Sqm but n.exc 0.38 sqm on vertical surfaces such as skirting, dado and rises to steps etc. including 10mm thick cement plaster in CM 1:4 set andset and jointed in neat cement slurry and pointed in white or colour cement to match the colour of tiles complete all as specified and directed. |
| 39 | M & L for non skid ceramic coloured tiles (Ist quality) 7 to 8 mm thick (Square/ rectangular), area of each tile exc 0.11 Sqm but n.exc 0.18 sqm on vertical surfaces such as skirting, dado and rises to steps etc. including 10mm thick cement plaster in CM 1:4 set andset and jointed in neat cement slurry and pointed in white or colour cement to match the colour of tiles complete all as specified and directed. |
| 40 | Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. complete all as specified and directed. |
| 41 | M&L for machine cut kota stone 18-20 mm thick as in floor, staircase, landing etc laid and jointed with grey cement slurry mixed with pigment to match the shade of the stone including grinding and mirror polishing, over and including 20mm thick screed bed in CM (1:6) as in floor complete all as specified and directed. |
| 42 | M&L for machine cut kota stone 18-20 mm thick in riser of steps, skirting, dado and pillar laid over and including 10mm thick rendering as bed or bedding layer in 15mm thick CM (1:4), set and jointed in neat cement slurry and pointed in white or coloured cement all as specified and directed. |
| 43 | Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlar ficings, dressed stone work and pre-cast concrete articles complete all as specified and directed. |
| 44 | M&L for brick work with sub class ‘B’ bricks old size, straight or curved on plan exc 6 M mean radius, built in CM 1:6 complete all as specified & directed but except brick. Note:- Bricks obtained from item No 43 shall be reused after cleaning. |
| 45 | M&L for special treatment of sunken portion of WCs and Bath room as per following stages:Stage 1 :- Demolition of WC including lime concrete and cement concrete coba etc and preparing the surfaces of existing sunken portion of WCs or bath etc with wire brush to remove all loose dirt, oil grease etc .Stage 2:- Providing10mm thick plaster in CM 1:3 with chemical of Dr. Fixit Pidicrete URP or plaster seal of STP LtdStage 3:-Applying Dr Fixit Primseal primer or STP Ltd (and allow to dry for 8 hours) under touch dry conditionStage 4:-Applyingtwo coats of water proofing decorative elastomeric coating system of Dr Fixit Raincoats with DFT 100 Micron or shalicry 215 of STP(The surface after painting one coats shall be allowed to dry of 6 hours before next coats) all as per manufacturer instructionStage 5:-Making holes in wall and fixing600mm long 40mm dia GI spout for draining the surplus water if any. |
| 46 | M&L Plain cement concrete 1:4:8 type D-2 as in mass filling in sunken portion. |
| 47 | S&F in repairs 10 ltrs capacity PVC flushing cistern low level (white) with inlet ball valve and handle including flush pipe, brackets, rubber bush, washers etc complete all as specified and directed. |
| 48 | S&F in repairs vitreous china urinal half stall type of size 580 x 380 x 350 mm, white, with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) including providing and fixing plug, bedding urinal against wall in cement mortar 1:2 securing urinal to plug with and including 60mm long brass screws, pointing around urinal back in cement complete all as specified and directed. |
| 49 | S&FBevelled edge mirror size 600 x 450mm of selected quality glass mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chrominium plated brass screws and cup washers all as specified and directed. |
| 50 | S&F in repair rotational moulded polyethene water storage tank 1000 ltr capacity, three layer, hoisted and fixed in position including PVC cover, plug and check nuts with 20mm dia ball valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe 20 mm dia (minimum weight- 210 gm)completeall as specified and directed. |
| 51 | S&F 20mm dia ball valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe 20 mm dia (minimum weight- 210 gm) complete all as specified and directed. |
| 52 | S&F in 1mm thick Steel sheet duccan suitable screws for 500/1000ltr PVC tank (For Monkey mirace), design and size approved by GE |
| 53 | S&F 32 mm dia PVC waste pipe for wash basin /urinal all as specified and directed. |
| 54 | S&F in repair CP health faucet with 1.5 m PVC connection as in repairs complete all as specified & directed. |
| 55 | S&F in repair PVC (SWR) gully trap 110 mm, setting and jointing with solvent cement complete all as specified and directed. |
| 56 | Cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete typeB-1(1:2:4) |
| 57 | S & F in repair vitreous china wash basin, white flat back , size 550mmx450mm with and including Waste fittings, brass, chromium plated forbasins with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed with and including Supplying and fixing cast copper alloy chromium plated fancy typepillar tap 15mm bore,screwed down high pressure with or without lettered hot or cold with long shanks, screwed for iron pipe complete all as specified and directed. |
| 58 | S & Fin repair tubular towel rail 60 cm length of stainless steel20 mm Dia with brackets type fixed with and including chromium plated brass screws and wooden/plastic cleats complete all as specified and directed. |
| 59 | S & F in repairs 15 mm bore chromium plated fancy bib taps, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. |
| 60 | S&F sheet glass shelf assembly consisting of 5.50mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard andrailing 60cm long complete all as specifiedand directed |
| 61 | S&F in repair PVC connection 15mm size with PTMT nuts, 600 mm long complete all as specified and directed |
| 62 | S & F repair 20mm Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed complete all as spd and dir. |
| 63 | S&Fin repair 150 mm square PTMT grating with openable flap (Min weight 100 gms) complete all as spd and dir |
| 64 | S&Fin repair 15 mm bore fancy typeCP Stop valve / angle valve screweddown, highpressure, withcrutch or butterfly handle, screwed both ends foriron pipe orfor unions and fixed complete all as specified & directed. |
| 65 | S&Fin repair 15 mm bore CP concealed Stop valves/Angle Valve, fancy type screweddown, highpressure, withcrutch or butterfly handle, screwed both ends foriron pipe orfor unions and fixed complete all as specified & directed. |
| 66 | S & F in repairs CP shower rose 150mm dia alongwith shower arm complete all as spd and dir. |
| 67 | Taking up or down 15mm bore steel tubing and connection complete all as specified and directed. |
| 68 | Taking up or down 20mm bore steel tubing and connection complete all as specified and directed. |
| 69 | Refixing old steel tubing 15mm bore and connections in new or old position (Walls, Ceiling, Floors etc) complete all as specified and directed. |
| 70 | Refixing old steel tubing 20mm bore and connections in new or old position (Walls, Ceiling, Floors etc) complete all as specified and directed. |
| 71 | S&F 15mm dia bore GI tubing, medium grade, galvanised with all fittings, fixed to walls, ceiling or laid in floors complete all as specified & as directed. |
| 72 | S&F 20mm dia bore GI tubing, medium grade, galvanised with all fittings, fixed to walls, ceiling or laid in floors complete all as specified & as directed. |
| 73 | S&F Vitreous china wash down water closet pan “Pedestal Pattern” whitewith wcseat cover coloured closed pattern with flat bottom and mild steel chromium plated or aluminized hingingdevice including pvc flush pipe and joints etc and connection to drain, flushing, pipe, anti-syphonagepipe, and fixing arrangements with fixing bolts etc ,complete all as specified and directed. |
| 74 | S&F in repairs vitreous China squatting pan, `Orissa\" pattern, size 580 x440 mm white, with integral foot rests (excluding flushing cistern and flush pipe and including concrete bedding) complete all as specified as directed. |
| 75 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings,heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre lineover fittings and accessories) complete all as specified and directed |
| 76 | S & F in repair 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to wall complete all as specified and directed. |
| 77 | S & F 110 mm bore PVC (SWR) bends of any radius complete all as specified & directed. |
| 78 | S&F110 mm bore PVC (SWR) single T with access door of any radius complete all as specified & directed. |
| 79 | S&F in110 mm bore PVC (SWR) single Y with access door of any radius complete all as specified & directed. |
| 80 | S & F in repair 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to wall complete all as specified and directed. |
| 81 | S&F75 mm bore PVC (SWR) single T with access door of any radius complete all as specified & directed. |
| 82 | S & F 75 mm bore PVC (SWR) bends with access door of any radius complete all as specified & directed. |
| 83 | Demolition of RCCRoofs, floors (other thanground floors) beams, staircases, landing, chhajjas and similar suspended work complete all as specified and directed. |
| 84 | S&Fjoist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) confirming to Fe-410W(GdeE-250) quality A complete all as specified and directed. |
| 85 | S&F 5.0 cm thick sand stone slabs in sun shades, chajjas, shelves, roof slabs etc n.exc. 2m in length punched dressed on face and along exposed edges, self faced on other side and set and pointed in CM 1:4 complete all as specified and directed. |
| 86 | Taking down carefully copper/aluminium point wiring on batten/ PVCconduit (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc, including removal and making good disturbed surfaces of walls, ceilings etc by cement/ colour /plaster to match with the existing location spot complete all as specified & directed. |
| 87 | M&L for concealed point wiring for one light point/fan point/bell point controlled by one switch (using red, black and green colour coding) complete with 1.5 sqmm unsheathed and multi stranded copper conductor single core FRLSH PVC insulated, 1100 volts PVC insulated unsheathed cable with proper colour codingdrawn in through and including PVC concealed conduit not less than 25 mm dia ( medium duty, ISI marked) with all fittings and accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc.,including pressed steel powder coated sunken terminal box suitable for modular switch socket and non modular switches and sockets, including provn of 1.5 sqmm single core FRLSH PVC insulated multi standed copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ ceiling/ floors etc by using CM (1:3) complete all as specified and as directed. NOTE:- Modular and Non-modular switches/ socket/ regulator shall be measured and paid separately under appropriate item. |
| 88 | All as per item No-87 here in before but for One socket outlet 5/6 Amps on independent switch board controlledby one switch completeit with 2.5sqmm unsheathed and multistranded copper conductor single core, complete all as specified & directed. |
| 89 | All as per item No-87 here in before but for One socket outlet 5/6 Amps controlled by one switch on same board with other switches complete it with 2.5 sqmm unsheathed and multistranded copper conductor single core, complete all as specified & directed. |
| 90 | All as per item No-87 here in before but using2.5 sqmm PVC FRLSH insulated stranded copper conductor cable andfor one socket out let 3/6 pin, 15/16 Amps controlled by one 1 way switch on independent board complete all as specified & directed.NOTE-For item no 87 to 90 -: (i)The quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillars etc for concealing the conduits to required depth & making good the disturbed surfaces in cement mortar 1:4 including finishing the surface to match with the existing surface. The portion of point wiring at RCC Columns/Beams/Ceilings etc shall be in surface conduit of suitable size fixed on surface with using PVC rawl plug and provision of covering terminal boxes/junction boxes of any shape and size with 3 mm thick bakelight laminated sheet fixed with suitable GI screws and cup washers.(ii) Fittings like switches,sockets,regulators,lamp holders,light fittings shall be measured and paid for separately under appropriate item of schedule A.(iii)The size of conduits shall be determined on permissible no of runs of wires as specified in SSR part-I clause 19.125 (B).However minimum size of conduit shall be 25 mm dia (medium grade).(iv) The rate of all type of conduit, fittings, rawl plugs etc deemed included in items. |
| 91 | All as per item No-90 above but using 4.0 sqmm PVC FRLS insulated stranded copper conductor cable and for one socket outlet 3/5/6 pin, 15/16A controlled by one way switch on an independent board complete all as specified and directed. |
| 92 | Supply and fix modular switch single pole, one way 5/6 Amps 1 module, complete all as specified and directed. |
| 93 | Supply and fix switch piano, flush type, single pole, 5/6 Amps one way, 230 volts complete all as specified and directed. |
| 94 | Supply and fixing modular switch 15/16 Amps single pole one way, one module, complete all as specified and directed. |
| 95 | Supply and fix switch piano, flush type, single pole, 15/16 Amps one way, 230 volts complete all as specified and directed. |
| 96 | Supply and fix modular socket outlet 3 pin 5/6 Amps, complete all as specified and directed. |
| 97 | Supply and fix socket outlet, 5/6 Amps, flush type, 3 pin 230 volts complete all as specified and directed. |
| 98 | Supply and fix modular socketmultipurpose 3/5 pin 15/16 Amps combined 2 module, complete all as specified and directed. |
| 99 | Supply and fix socket outlet, multi-purpose 3/5 pin 15/16 Amps complete all as specified and directed. |
| 100 | Supply and fix modular step type, 2 module electronic fan regulator heavy duty 120watts 240 volts,complete all as specified and directed. |
| 101 | Supply and fix step type electronic fan regulator heavy duty 120watts 240 volts,complete all as specified and directed. |
| 102 | S&F switch, bell push button, single pole,5/6 Amps, one way, 230 Volts complete all as specified and directed. |
| 103 | Supply and fix call bell, Ding dong type, 230 volts AC single pole complete all as directed. |
| 104 | Supply and fixing modular cover plate with metal frame (inner and outer) 2 module for mounting switch and sockets all as specified and as directed. |
| 105 | Supply and fixing modular cover plate with metal frame (inner and outer) 3 module for mounting switch and sockets all as specified and as directed. |
| 106 | Supply and fixing modular cover plate with metal frame (inner and outer) 4 module for mounting switch and sockets all as specified and as directed. |
| 107 | Supply and fixing modular cover plate with metal frame (inner and outer) 6 module for mounting switch and sockets all as specified and as directed. |
| 108 | S&F for ceiling rose surface bakelite 62.5 x 25 mm size 3 terminals complete all as specified and directed. |
| 109 | Supply & fix commissioning and testing of complete power cum starter unit compressing of ON/OFF switches socket 3 pin socket outlet with plug top modular type made out of white polycarbonate, fire retardant, UV stabilized power unit internally pre-wired with suitable size copper conductor cable with overload protective device (MCB) complete unit fixed in single polycarbonate housing with inlet & outlet cable port suitable for AC & geyser operated at single phase, 240 volts, 50 Hz AC supply of capacity 20 Amps load bearing capacity complete all as specified and directed. |
| 110 | Supply and fix lamp holder insulated body with back plate for batten fitting complete all as specified and directed. |
| 111 | Supply and fixing LED Bulb 15 watt, colour temp-6500K, lum output-945lm, Base cap- B22 single phase, 230 Volts AC supply suitable for lamp holdercomplete all as specified and directed. |
| 112 | Supply and fixing LED luminaire fully diffused, 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light, extruded aluminium housing 11.5mm depth only,edge lit LED panel with light output of 3000 lumen, 25000 hrs life class, 4000k Neutral white light, complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete as specified and directed. |
| 113 | Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LEDlight warm yellow in colour with a nominal system output of 120 lum/watt (min) with p.f. not less than 0.9 including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 114 | Supply and fixing 20W Inverter LED batten of size 4 ft with square profile and polycarbonate channel. Lithium Ion battery with charging time 8hours-10 hours and back up time upto 4 hours including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete |
| 115 | Supply and fix LED sensor batten 20W, 2000lm power saving LED lighting, smart motion and ambient light sensor, less energy consumption – Lesser Electricity bill & Higher savings Convenience - Bright & Efficient light source with 100lmn/. Complete all as specified and directed. |
| 116 | S&F Mirror light Decorative ultra slim square profile liner LED lighting fixture with extruded polycarbonate body with 9 W power consumption LED warm white in colour with a nominal system output of 120 lum/watt(min) with PF not less than 0.9 completeall as specified and directed. |
| 117 | S&F in replacement LED security with aluminum pressure die cast housing, high purity PC fresnel diffuser with silicon gaskets for IP-65 protection, power consumption of 35 W and system efficiency > 100lm /W, in built electronic driver pre-wired upto terminal block with driver efficiency > 85% power factor > 0.95, suitable for external pole upto 35mm LED Make :- Nichia/Cree/Osram, CRI > 70, ambient temperature range 0-450c, THD<10%, colour temperature 5700K, surge protection cm 3.5KV 50000burning hour as per L70 criteria, multistage constant current constant voltage operated driver with range 150 -270 V AC and safety extra low voltage safe level < 60V DC as per IEC standard including GI pipe medium grade ISI mark of size 25 mm dia length not less than 1.5 mtrs bending to shape for fixing light and nuts, bolts, clamp as required to fix to wall all as specified and directed. |
| 118 | Taking down care fullysub main wiring / service connections of any size including batten/ conduit, and making good the disturbed surfaces of wall/ floor . |
| 119 | M&L forsub main wiring with two runs of single core FRLS PVC insulated, unsheathed, multistranded copper conductor cable of size 6.0 sqmm drawn in and including rigid PVC rigid conduit medium grade of suitable size but not less than 20mm dia with its accessories, concealed type, including one run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 6.0 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed. Notes:-Finished sub main wiring with two runs of 6.0 sqmm cable & one run of 6.0 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length. |
| 120 | M&L forsub main wiring with two runs of single core FRLS PVC insulated, unsheathed, multistranded copper conductor cable of size 4.0 sqmm drawn in and including rigid PVC rigid conduit medium grade of suitable size but not less than 20mm dia with its accessories, concealed type, including one run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 4.0 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed. Notes:-Finished sub main wiring with two runs of 4.0 sqmm cable & one run of 4.0 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length. |
| 121 | Taking down distribution boards any size any type including MCB TPN/SPN/SP etc and making good the disturbed surfaces. |
| 122 | Supply and fix MCB DB vertical type 4 way VTPN sheet metal enclosure 415 volts with 100 Amp fully insulated standard copper bus bar for each face & surrounded with neutral bars and two common neutral bar, two earth bar including cable tiesfor cable management suitable for housing MCCB TPN 415 Volts as incommer, IP-43, IK-09 as per IEC 61439-3 with metal doors all enclosed on standard steel sheet flush mounting type double door factory fabricated completewithout MCB & MCCB but with enclosure blank plate complete all as specified and directed . |
| 123 | Supply and fix in replacement MCB DB sheet metal enclosure factory fabricated double door SPN 12 way with 100 amps rated copper bus bar 240 volts IP-43, IK-09 with metal doors complete all as specified and directed. |
| 124 | Supply and fix in replacement MCB DB sheet metal enclosure factory fabricated double door SPN 4 way with 100 amps rated copper bus bar 240 volts IP-43, IK-09 with metal doors complete all as specified and directed. |
| 125 | S&F MCCB of rating 125 Amp, 4 pole, 415 V, AC fixed type with breaking capacity 16 KA DPX³ 160 type, as per ICE- 60947-1 Ics 100% of Icu, Adjustable tripping: 0 - 0.3 - 1 - 3s with adjustable 70% to 100% and thermal magnetic release to be fixed in existing LT panel for taking In coming electric connection for VTPN DB complete all as specified and directed at site. |
| 126 | Supply and fixing in replacement MCB SPN240V,50 Hz, 10KA \"C\" curve miniature circuit breaker (MCB) and current carrying capacity SPN 40 to 63 Amp rating in the MCB DB complete with connection testing and commissioning complete all as specified & directed. |
| 127 | Supply and fixing in replacement MCB SPN240V,50 Hz, 10KA \"C\" curve miniature circuit breaker (MCB) and current carrying capacity SPN 32 Amp rating in the MCB DB complete with connection testing and commissioning complete all as specified & directed. |
| 128 | Supply & fix in replacement MCB SP, 40 Amps, \"C\" Curve, 240 volts, 50Hz, 10kA IP-20 as per IS/IEC 60898-1 2002 ISI marked complete all as specified & directed. |
| 129 | Supply & fixMCB SP, 6 to 32 Amps, \"C\" curve, 240 volts, 50Hz, 10kA IP-20 as per IS/IEC 60898-1 2002 ISI markedcomplete all as specified & directed. |
| 130 | Supply and fix electric water heater, of capacity 25 Ltrs vertical storage type, outer body of the heater is made with tough ABS material with special inner tank coating that prevents corrosion and rusting and results in a long tank life energy-efficient and HeatingElement upto 2 KW (copper tube)-Spiral Type Multiple safety systems for protection against dry heating, overheating and overpressure, BEE 5 Star rated complete with all accessories such as safety valve, thermostat, NRV, connection piece (hot & cold of length upto 450 mm long withto be fixed on wall withfastener mild steel 100 mm long x 10 mm dia with expansion type split pin and bolts complete for hanging of geyser all as specified and directed |
| 131 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 380mm, complete all as specified and directed. |
| 132 | Supply and fix ceiling fan, 1400mm sweep, minimum 210 CFM, 230 V, BEE 5 star rated, BLDC(brushless direct current motor ) type complete with standard accessories i.e (three blade, 02 Nos canopy, electronic type modular fan regulator 90 to 100 W, down rod of length 1.5 mtr to 2.0 mtr long, 01 No. fan hock, 02 Nos hanging clamps with rubber real insulator, nuts, lock nuts,bolts, washers, split locking pins etc), double ball bearing, copper wound with synchronous motor, including electrically connecting from ceiling rose to fan connector with 0.5 Sqmm stranded copper conductor 3 core flexible cable cord complete all as specified and directed. |
| 133 | M & L earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm size, buried directly in ground (earth pit not less than 2.25 M deep below normal ground level) with top edge of the plate not less than 1.5 M below normal ground level connected to and including galvanized steel earth lead wire of 4 mm dia, including 15 mm bore GI light grade protection pipe upto 1 Mtr above the floor level of the buildings where main switch, DB etc, situated, earth lead wire connected to the earth plate by means of GI bolts, nuts, washers and earth plate surrounded by 150 mm thick alternate layers of charcoal or cock dust mixed with common salt 20 mm bore medium grade GI watering pipe PCC pit in PCC 1:3:6 type C-1 (using 20 mm graded stone aggregate) cover of precast RCC 1:2:4 type B-1(using 20 mm graded stone aggregate) duly reinforced with 8 mmformed or twisted bars @ 100 mm c/c both ways, GI wire mesh, GI sheet funnel necessary excavation in soft/ Loose soil and deposited the surplus soil to a distance not exceeding 50 mtr away from starting point, all as per electrical plate no:3 of SSR part-1 . |
| 134 | M&L for rigid non metallic PVC conduit (medium quality ISI marked) 2 mm thick exclusive of boxes (junction/ terminal) 25 mm dia (external) fortelephone & TV cablewiringbut inclusive of all fittings such as tees, bends, reducers, bell mouth, tube ends and concealed to wall/ roof/ floor complete all as specified and directed. |
| 135 | Supply and fix dish TV cable cordof size 1.5 Sqmm solid copper conductor triple insulated steel wire mess inner sheathing earth continuity conductor, coaxial cables and over all PVC sheathed circular complete all as specified & directed. |
| 136 | Supply & Fix Cable TV outlet socket switch type flush mountedincluding modular cover plate and metal flush boxsuitable for TV cable cord connection complete all as specified & directed. |
| 137 | M&L for electrically disconnecting and taking down existing ceiling/Exhaust fans from any height or in any position from existing bldg and keeping in safe custody for reuse including replacement of three core flexible copper conductor cable from ceiling rose to fan connector block of size 0.75 Sqmmand hanging fan clamps, nuts, bolts and rubber reel bush etc & testing for proper functioning complete all as directed at site by Engr-in-Charge. |
| 138 | Supply and fix single pointed air termination aluminium rod , 12 mm dia, 300mm long of GI on Hanger roofat height upto 11 mtr with necessary arrengment for fixing on roof with insulating material of minimum 6 mm thick PVC insulation between roof structure amd air termination point including necssary screws, nuts, bolts & washer of GI with suitable size base plate to fixed in a manner to insure non conductivity with bldg structure complete all as directed and specified Note:- Rate for required T&P, Ladders/ Lifter & necessary safety equipment deemand to be included to the qoated rate. |
| 139 | Supply and fixing aluminum strip 25 x 3 mm with saddle of porcelain insulator and fixing screwsnot less than 50 mm long with PVC plug & gutties etc. on roof/wall and connecting from earth pit the lightning rods point on Hanger at height upto 11 mtr etc all as specified and directed |
| 140 | Supply and fixing GI strip 32x6 mm with saddles/insulators and fixing screws not less than 50 mm long with PVC plug & gutties etc. for roof conductors and down conductors above ground on Hanger at height upto 11 mtr all as directed and specified. |
| 141 | M & L earthing complete with using 32 x 6 mm galvanized MS strip and MS galvanized plate of size 600 x 600 x 6 mm ,as earth electrode, buried directly in ground (earth pit not less than 2.25 M deep below normal ground level) with top edge of the plate not less than 1.5 M below normal ground level connected to and including40 mm bore GI light grade protection pipe upto 1 Mtr above the floor level of the buildings where main switch, DB etc, situated, earth lead wire connected to the earth plate by means of GI bolts, nuts, washers and earth plate surrounded by 150 mm thick alternate layers of charcoal or cock dust mixed with common salt 20 mm bore medium grade GI watering pipe PCC pit in PCC 1:3:6 type C-1 (using 20 mm graded stone aggregate) cover of precast RCC 1:2:4 type B-1(using 20 mm graded stone aggregate) duly reinforced with 8 mmformed or twisted bars @ 100 mm c/c both ways, GI wire mesh, GI sheet funnel necessary excavation in soft/ Looose soil and deposited the surplus soil to a distance not exceeding 50 mtr away from starting point, all as per electrical plate no:3 of SSR part-1. |
| 142 | M&L for test point terminal block made of gun metal or phosphouus bronze size 75 X 75 X 25 mm drilled and screwed including 3 Nos 8mm dia 25mm long hexagonal screws all as directed and specified. |
| 143 | Supply and lay pipe galvanized, “Medium class”, including fittings 40 mm (1.5”) dia complete all as directed and specified |
| 144 | Supply & Laying,jointing,commissioning and testing XLPEinsulated steel armoured heavy duty elect power cable 1100 volt grade, stranded aluminium conductor 4 core 16 sqmm laid in trenches or fixed to wall with saddles or layed in duct or passing through pipe for making electric service connection between LT panel/ feeder pillar box to MCB DBs/ Main Switch/Change over compele all as specified and as directed by Engr-in-Charge. |
| 145 | Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr deep in soft/loose/ soil for taking out/laying CI/GI pipe line and getting out soft/loose soilcomplete all as specified and as directed by Engineer-in-Charge. |
| 146 | Returning, filling in including spreading, leveling, watering and well ramming in layers n.exc 25 cm thick layers complete all as specified and as directed by Engineer-in-Charge. |
| 147 | Removal of excavated material n.exc 50 mtr away and depositing where directed at a level n.exc 1.5 mtr above from starting point complete all as specified and as directed by Engineer-in-Charge. |
| 148 | Supplying and laying un-reinforced precast concrete cable cover LV type-I flat size 250 mm x 150 mm x 40 mm in trenches for protection of cable. |
| 149 | M&L for sand cushioning dry fine for cable cushioningbelow and abovethe cable complete all as directed at site by Engr- in-Charge. |
| 150 | Supply and fixing GI Pipe 40mmLight grade , for cable protection laid in trench under road or pathor fixed on pole or wall with clamps with all fittings complete all as specified and as directed at site,. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail