| 1 | Dismantlingof wall & ceiling boards ( fibre,pulp,insulation etc. ) or insulation board/ slabs/blankets, any thickness, including cover fillets complete all as specified and directed. |
| 2 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground, post embeded in concrete or brick masonary complete all as specified and directed. |
| 3 | Dismantling, floor, hearth or wall tiling including CM bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 4 | Dismantling of framed work of timber scantlings 40 sq.cm and over in section, in any position complete all as specified and directed |
| 5 | Dismantling of framed work of fillets, rails, posts, rafters, purlins, etc under 40 sq.cm in section complete all as specified and directed |
| 6 | Dismantling of asbestos cement (corrugated, semi corrugated etc.) sheets in roof coverings complete all as specfied and directed. |
| 7 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed |
| 8 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 9 | Demolition of reinforced cement concreteof any description of any position not otherwise specifically provided for man hole cover slabcomplete all as specified and directed. |
| 10 | Demolition of brick work/ stone masonry/ PCC block masonry built in cement mortar or cement lime mortar including all quoins, pillars, arches etc, but excluding ashlar facings dressed stone work and precast concrete articles complete all as specified and directed. |
| 11 | Taking down chowkhat n.exc 1.5 sqm each without taking off shutter from frame complete all as specified and directed. |
| 12 | Taking down chowkhatexc 1.5 sqm and n.exc 4.00 sqm each without taking off shutter from framecomplete all as specified and directed. |
| 13 | Taking down cement plaster of any description including scrubbing down with water and prepare to receive new plastering in wall complete all as specified and directed. |
| 14 | M&L for RCC (Nominal mix) type B1 ( 20mm graded stone aggregate)for beam, cantilevers, bressummers lintel over 1.5 mtr span etc complete all as specified and directed. |
| 15 | Use and waste forformwork to sides and soffits of floor or roof beams,beam haunchings, girders, bressummers, lintels, cantilevers, shelves including suports over hangs etc.complete all as specified and directed. |
| 16 | M&Lfor TMT steel barsin reinforcement 10mm dia and over cut to length bent to shape required including crankingbindingspirally, hooping for columns hooking ends and binding with and including mild steel wire (annealed)not less than 0.9mm dia complete all as specified and directed. |
| 17 | M&L for TMT steel barsin reinforcement8mm dia and over up to 10mm dia in stirupscut to length bent to shape required including crankingbindingspirally, hooping for columns hooking ends and binding with and including mild steel wire (annealed)not less than 0.9mm dia complete all as specified and directed. |
| 18 | M&L 50 mm thick PCC 1:3:6 type C-2 using 20mm graded aggregate as in plinth protectionfinishing even & Smooth without using extra cement laid in bays with construction, 6mm thick joints should be filled with bitumen mastic filling comprising of one part of heated bitumen 80/100 gde and three part of sand ( all by weight) complete all as specified and directed. |
| 19 | M&L for PCC (1:2:4) type B1 using 20 mm graded aggregate for coping including necessary formwork complete all as specified and directed. |
| 20 | M&L for PCC 1:2:4 type B-0 (12.5 mm graded aggregate ) bed or bedding layer of 25mm thick in laying floor finishes complete all as specified and directed. |
| 21 | M&L for Non Skid ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, over 15mm thick screed bed in CM 1:6 as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 22 | All as per Item No.21 here-in-before but on vertical surfaces such as skirting, dados and riser to steps over and including 10mm thick backing coat in CM 1:4complete etc set ,jointed in neat cement slurry and pointed to match in white or coloured cement to match complete all as specified and directed. |
| 23 | M&L for machine cut kota stone slab flooring 20-25mm thick laid over 20mm thick cement screed in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed. |
| 24 | M&L for kota stone slab 20-25mm thick as in riser steps, skirting or dado and pillar laid over 10mm thick backing coat in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed. |
| 25 | S&F for125X60 mm size of pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and directed. |
| 26 | M&L for plain cement concrete type C1, 1:3:6 (using 20 mm graded stone aggregate) for filling of hollowpressed steel frame complete all as specified and directed. |
| 27 | S&F for 25 x 3mmFI hold fast conforming to Fe 290, Gde -E-165 complete all as specified and directed. |
| 28 | M&L for plain cement concrete type B-0 1:2:4 (using 12.5 mm graded stone aggregates) for fixing hold fast including repairing of disturbed plaster (while taking down Door/ window, ventilator frame) and matching the repaired surface with existing one complete all as specified and directed. |
| 29 | S&F for 35mm thick second class hardwood factory made flush door shutters, solid, core construction with block board core and plywood face panels commercial type on both sides complete all as specified and directed. |
| 30 | S&F for 35 mm thick second class hardwood factory made glazed and skeleton shutters open rebated and prepared to receive glass gauge etc. withoutsash bars sizes of the members of the shutters as specified in SSR Part-I section 8 , clause 8.24 (a) complete all as specified and directed. |
| 31 | S&F formild steel butt hinges 100mm size of medium weight complete all as specified and directed. |
| 32 | S&F for 200mm long Aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed. |
| 33 | S&F for 150 mm long Aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed. |
| 34 | S&F for 150 mm long Extruded aluminium alloy handles, fabricated type., anodised complete all as specified and directed. |
| 35 | M&L for 300mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed |
| 36 | M&L for Brick work with sub class ‘B’ brick, straight or curved as plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed |
| 37 | M&L for rendering 15mm thick on other than fair faces of brick work or concrete surfaces with CM 1:6 finished even and smooth without using extra cementcomplete all as specified and directed. |
| 38 | M&L forrendering 15mm thick on fair faces of brick work or concrete surfaces with CM (1:4) finished even and smooth without using extra cement with WPC @3% by weight of cementcomplete all as specifed and directed.Note : WPC Shall be measured and paid seperately |
| 39 | Supply only water proofing compound |
| 40 | M&L for Preparing new plaster surface apply two coat of distemper oil emulsion over a coat of 3 mm thick wall care putty of JK /Birla white complete all as specifed and directed. |
| 41 | M&L for prepraring newly plastered surfaces of wall and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade over and including primer coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. |
| 42 | M&L for preparing new steel surfaces and applying two coats of syntheitc enameled paint over a red oxide primer exc 10 cm width or girth complete all as specified and directed. |
| 43 | M&L forpreparation of new or previously un treated wooden surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 44 | S&F for Steel ventilators with centre hung shutter including two pair of brass cup pivots catch spring and pully wheel complete all as specified and as directed. |
| 45 | S & F for powder coated Aluminium sliding windows three track with two glass shutters using 4 mm thick glass tinted and one shutter with stainless steel wire gauge wire cloth 0.31mm nominal dia of wire and width of aperture 1.61mm, using Aluminium powder coated sect, Aluminium cleat, PVC track, bearing, handle lock rubber beading, etc complete all as specified and directed. Note: Size of aluminum sections are as under :-(i) Shutter vertical section - Jindal main – 2010 Section No 20606.(ii) Shutter top & bottom - Jindal main – 2010 Section No 20604(iii) Shutter vertical middle (interlock) - Jindal main – 2010 Section No 20605.Note : 4 mm thick tinted glass and wire cloth shall be measured and paid separately. |
| 46 | S&F for 4 mm thick tinted sheet glass, with necessary clip or clamp, screws etc in square n exc 0.5 sqm in each pane complete all as specified and directed. |
| 47 | S&F forStainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 48 | S&F forAluminium anodised grill (anodised trasparent or dyed to required shade according to IS:1868 with minimum anodised coating of grade AC15) of approved design/ pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per reqirement and direction of Engineer-in-Charge |
| 49 | S&F for 375mm, mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed |
| 50 | S&F for Harrison rails, mild steel, chromium plated with fixing brackets, stops,rollers etc, complete all as specified and directed. |
| 51 | S&F for Steel work in tubular section as in post including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed. |
| 52 | S&F for mild steel rolled sections as in roof trusses (framed), trussed purlins crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle,channel or flat sections) including distance pieces, cleats ( Fe 410-W (Gde E-250) quality A) complete all as specified and directed. |
| 53 | S&F for rolled sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates ( Fe 410-W (Gde E-250) quality A)complete all as specified and directed. |
| 54 | S&F for plates (plain or chequered) channels. Square cut or notched (ordinary and counter sunk) forming holes, without any attachment using Fe 410 -W (Gde- E- 250) quality- A with reveted bolted or welded attachment complete all as specifed and directed. |
| 55 | M&L for mild steel screw bolts (machine made) 5 to 10mm dia of neck with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed and to be fitted with washers and one hexagonal or square nut n exc 5 cm longcomplete all as specifed and directed. |
| 56 | M&L for mild steel screw bolts (machine made) 11 to 15 mm dia of neck with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed and to be fitted with washers and one hexagonal or square nut exc 22.50 cm and n,exc 30cm longcomplete all as specifed and directed. |
| 57 | S&Ffor Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specifed and directed. |
| 58 | S&F for Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specifed and directed. |
| 59 | S&F for powder coated aluminium snap grid frame work for false ceiling with aluminium angle 25 mm x 25 mm x 1.5 mmfixed to perimeter of wall, main \"T\" runner 38 mm x 25 mm x 1.5 mm and secondary/cross \"T\" runner 25 mm x 25 mm x 1.5 mm to be interlocked in such a way that the size of grid shall be 605 mm x 605 mm including 6 mm dia GI hangers (upto 1200 mm length) adjusting level fixed to roof by means of ceiling cleats made out of GI flat 40 x 3 mm, 60 mm long and expansion hold fasteners 12.5 mm dia , 40 mm long and 4 mm thick Non asbestos fibre board (E-board or V board) designer tiles (Electra) suitably fixed in false ceiling grid/frame with staples or screws complete all as specified and directed. |
| 60 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out in hard/dense soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm thick complete all as specified and directed. |
| 61 | Removing excavated material exc. 250 m but n exc. 500 m and depositing where directed complete all as specified and directed. |
| 62 | M&L for cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate as in mass concrete and foundation filling complete all as specified and directed. |
| 63 | M&L 75mm thick PCC 1:4:8 type D2, by using 40mm graded stone aggregate as in sub base complete all as specified and directed. |
| 64 | Demolition of cement concrete (un-reinforced)in roof/floors other than ground level beam, stair case, landing, chajjas and similar items includingwater proofing treatment in any layersand removal of debris to distance exceeding 250m and not exceeding 500m from the site complete all as specified and directed. |
| 65 | M&L forPCC 1:2:4 (Type B1 using 20 mm graded aggregate) levelling course average thick 40 mm,to match the undulations of roof complete all as specified and directed. |
| 66 | M&L for rendering 10 mm thickon fair faces of concrete surfacein cement mortar 1:3 for receive the roof finishes with water proofing liquid. (WPL Shall be measured and paid separately) complete all as specified and directed. |
| 67 | M&L for fillet of 75mm size using PCC 1:2:4 type B-1 (using 20 mm graded aggregate) at the junction of all horizontal and vertical surfaces complete all as specified and directed. |
| 68 | M&L for APP based polymeric membrane minimum weighing 3.50 kg/Sqm and minimum 3mmthick reinforced with polyster non wovenfabric (wt not less than 160 gm/sqm) laidoverprimed surface including bituminous primer conforming to IS-3384-1965 applied @ 0.3 ltr/ Sqm by torched application complete all as speficied.Three course roof treatment consists of as under :-(i) Applying one coat of bituminous primer conforming to IS-3384-1965@ 0.30 ltr/Sqm.(ii) laying APP based membrane as specififed.(iii) Applying a layer of blown gradebitumen85/25 @ 1.2 Kg/Sqm conforming to IS : 702 |
| 69 | M&L for framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 70 | M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. |
| 71 | M&L for 60 mm thick glossy finish machine pressed precast concrete interlocking paver blockwith grey cement and pigment any shape and size confirming to IS 15658-2006 of M-35 gradecomplete all as specified and directed. |
| 72 | S&F for glossy finished Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors over 15 mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 73 | Taking down copper / aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials for taking credit and making good disturbed surfaces of walls, floors and roofs etc all as specified and as directed. |
| 74 | Taking down sub main wiring complete including fitting and fixtures, removing materials for taking credit and making good disturbed surfaces of walls, floors, roof etc, all as specified and directed. |
| 75 | Taking down carefully unserviceable DBs any type/size With MCCBs/MCBs//Isolator etc and disconnecting from supply and making good disturbed surfaces complete all as directed. |
| 76 | M & L for complete point wiringwith 1.5 Sqmm single core multi stranded copper conductor FRLSHinsulated and unsheathed heavy duty cable in colour code including continuous earth wire with cable of size 1.5 sqmm copper conductor flexible FRLSH insulated drawn in and including concealed PVC rigid conduit medium gradeISI marked after cutting chases in wall , plastering after concealing conduit , including modular galvanisedflush boxes of suitable size and white cover plate with frame as per relevant ISfor mounting modular switches, sockets, fan regulators etc complete all as specified and as directed for the following :- |
| 77 | One light point controlled by one switch. |
| 78 | One Ceiling fan/Exhaust fan point controlled by one switch and one regulator. |
| 79 | One 3 pin switch socket outlet point 5 Amps on independent board. |
| 80 | One 3 pin switch socket outlet point 5 Amps on same board with other switch. |
| 81 | All as per item No 76 here in-before but with copper conductor cable for one 3 pin socket outlet, 15 amp independent, with cable 2.5 sqmm size complete all as specified and as directed.. |
| 82 | Supply and fix modular type switch, one way 6 Amps , 1 module complete all as specified and directed. |
| 83 | Supply and fix modular type switch, one way 16 Amps, 1 module complete all as specified and directed. |
| 84 | Supply and fixmodular type socket 5 pin, 6 Amps 2 module complete all as specified and directed. |
| 85 | Supply and fixmodular type socket 5 pin, 6 A/16 Amps2 module complete all as specified and directed. |
| 86 | Supply and fix ceiling rose surface backlite 65x50 mm 3 terminals ccomplete all as specified and directed. |
| 87 | Supply and fixModular fan regulator step down 120 Watt, 2 module complete all as specified and directed. |
| 88 | Supply and fixlamp holder PVC type with back platefor lamp holder fitting complete all as specified and directed. |
| 89 | Supply and fix LED lamp suitable for B22 holder of capacity 9 Watt complete all as specified and directed. |
| 90 | Supply and fixixing LED lights fitting 1 x 20 W, 220 V, AC decorative box type with driver, holder, including LED Tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 91 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. |
| 92 | Supply and fix Vertical Distribution Board MCCBs VTPN 4 way double door suitable for MCCB four pole as incomer and out going MCBs and should be IP 43 protected with Copper BusBars, Neutral Links, Earthing bar all complete all as specified and directed.Note:- (i) MCCBs four pole shall be measured paid separately (ii) MCCB, MCB & DB shall have the same make. |
| 93 | Supply and fixMCCBs, 4 pole,415 volts, 100 Amps, 16 KA complete all as specified and directed. |
| 94 | Supply and fixMCB, single pole, 240 volts, 6 to 32 Amps, 10KA, C series complete all as specified and directed. |
| 95 | Supply and fixing ofMCB, single pole & neutral, 240 volts, 32 to 63 Amps, 10 KA,C series complete all as specified and directed. |
| 96 | Supply and fix sheet metal enclosure distribution board SPN 8 way 240 voltswith IP 43 protection and double door, Bus bar rating 100 Amps, suitable for mounting MCBs all as specified. |
| 97 | Taking down ceiling fan cable end, dismantling blades and removing fan and blades complete all as directed by Enge In charge. |
| 98 | Hanging only fan (M D Sully) and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and directed. |
| 99 | M & L Painting of ceiling fans complete, with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust complete all as specified and directed. |
| 100 | Supply and fix of exhaust fan, steel body AC single phase. 230 V of size 300 mm sweep with, blades,frame and louvers and including making of holes in wall, floor etc complete all as specified and directed. |
| 101 | M & L for complete earthingwith galvanised mild steel earth plate electrode of size600x600x6mm thick burried directly in ground earth (in vertical) earth pit not less than 2.25mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr below ground level connected to galvanised iron orearth lead wire 4mm dia (8 SWG) by means of nut, bolt, check nuts and washer of galvanised ironl including PCC pit in PCC 1:2:4 type B-1 pre-cast RCC cover slab using reinfocement with XPM weighing not less than 1.87 kg/Sqm with suitable handle made of 12mm round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube for watering with one end fixed with cast iron funnel and wire mesh, 15mm dia bore light grade galvanised steel tubing upto 7.5 m length fo drawing earth lead wire protection, common salt, charcoal, etc complete all as shown in electrical plate No 3 of SSR Part-I and testing on completion complete all as specified and directed. |
| 102 | Supply and fixing Bldg Security light fitting 35W LED IP66 New generation energy saving & environmental friendly long life Versatile pressure die-cast aluminium with lens and toughened glass type roadway luminaire with high powerLEDs as light source including electronic driver 35W LED 6000K complete all as specified and directed. |
| 103 | Material and labour for street light bracket made out of GI pipe 1.2 mtr long 40mm dia medium grade bent to shape as directed including MS clamps made out of 25mmX3mm flat iron for fixing bracket suitable for Wall including nuts and bolts of required size including painting with one coat of aluminium paint over a coat of red oxide / primer complete all as specified and directed. |
| 104 | M & L for submain wiring alongwith earth wire with the following sizes of FRLSHPVC insulatedcopper conductor single core cable , multi-strandedand including suitable size of PVC conduit to be concealed and all accessories concealed in walls / roofs / ceiling etc. earth dolly, terminated interminal box all as specified and directed by Engr-in-charge for 2x6 sq mm and 1x6 sq mm as earth wire Note : (i) Two runs of copper conductor and one runs of earth copper conductor and one run of conduit shall be measured as one unit. |
| 105 | M & L for submain wiring alongwith earth wire with the following sizes of FRLSHPVC insulatedcopper conductor single core cable , multistrandedand including suitable size of PVC conduit to be concealed and all accessories concealed in walls / roofs / ceiling etc. earth dolly, terminated interminal box all as specified and directed by Engr-in-charge for 2x4 sq mm and 1x4 sq mm as earth wire Note : (i) Two runs of copper conductor and one runs of earth copper conductor and one run of conduit shall be measured as one unit. |
| 106 | Supply and fix ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed. |
| 107 | Supply and fixing ofdouble pole sheet metal enclosure with a two pin and earth plug and socket complete MCB of 20 Amp complete all as specified and directed. |
| 108 | Supply, laying and Testing of underground LT cable 1100 Volts grade heavy duty electric cable XLPE insulated & PVC outer sheathing with aluminium stranded conductor, Armoured cable 16 sq mm 4 core cable including taking down unserviceable cable complete all as specified and as directed. |
| 109 | Excavation in trenches not exceeding 1.5m in width and not exceeding 1.5m in depth and getting out in any type of soil complete all as specified and as directed. |
| 110 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm complete all as specified and as directed. |
| 111 | Removal of excavated surplus material to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specifieds and directed. |
| 112 | Supply & laying dry river sand as cable cushioning 15cm thick layer before laying and 8cm thick over cable after laying the cable in trench complete all as specifieds and directed. |
| 113 | M & L for unreinforced precasted concrete cable cover class LV, type 1,flat , size 250mm x 150mm x 40mm complete all as specified and as directed. |
| 114 | Material and labourfor GI pipe \"\"light grade\"\"for road crossing / on wall / on pole with fixed clamps, nuts, boltsfor cableprotectionof size 50 mm dia complete all as specifieds and directed. |
| 115 | Material and labour for cutting of bituminous road / floor / culvert / PCC hard standingfor laying of pipe / cables not exceeding 1.5 meter wide and not exceeding 1.5meterdeep including refilling / with material and, watering well ramming / compacting and making good with PCC 1;2;4,type B-1, 100 mm thick complete all as specified anddirected. |
| 116 | Schedule of credit amount of Rs 145385.00 to be deducted during AOC. |