| 1 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. a) Group A |
| 2 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.a) Group A |
| 3 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 4 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 5 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 6 | Wiring for light/ power plug with 2X4 sq. mm FRLS/HFFRPVCinsulatedcopperconductorsingle corecableinsurface/recessedmediumclassPVC conduit along with 1 No. 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable for loop earthing as required. |
| 7 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. a) 25 mm |
| 8 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. |
| 9 | 3 Module (100mmX75mm |
| 10 | 6 Module (200mmX75mm) |
| 11 | 12 Module (200mmX150mm) |
| 12 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 13 | 5/6 amps switch |
| 14 | 15/16 A switch |
| 15 | 3 pin 5/6 A socket outlet |
| 16 | 6 pin 15/16 A socket outlet |
| 17 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in theexistingsurface/recessedsteel/PVCconduitas required. |
| 18 | a) 3 x 1.5 sq. mm |
| 19 | c) 3 x 4 sq. mm |
| 20 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 21 | Supplyingandfixingfollowingway,singlepoleand neutral,sheetsteel,MCBdistributionboard,240V, onsurface/recess,completewithtinnedcopperbus bar, neutral bus bar, earth bar, din bar, interconnections,powderpaintedincludingearthing etc. as required. (But without MCB/RCCB/Isolator) 6 way , Double door |
| 22 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 23 | Single pole |
| 24 | Double pole |
| 25 | Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker shouldbe below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard.Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 26 | 18-22 Watt |
| 27 | 40 Watt |
| 28 | Supply, installation testing & commissioning of ceilingfanwithBrushLessDirectCurrent(BLDC) Motor,classofinsulation:B,3nos.metal(Aluminium alloy)blades,30cmlongdownrod,2nos.canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as perIS:374-2019),THD(TotalHarmonicDistortion) lessthan10%,remote(preferablymobileappbased) for speed control and all remaining accessories includingsafetypin,nutbolts,washers,temperature rise=750C(max.),insulationresistancemorethan2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supplyCeilingFancomplianttoIS374:2019fani/c external connections with 1.5 sq.mm FRLS/HFFR, PVCinsulatedcopperconductorsinglecorecable andearthingetc.asrequired.1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 29 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 30 | Supply of following sizes XLPE insulated & PVC sheathedarmoured aluminum conductorpower cable of 1.1 KVgrade confrming to IS :7098 (Part 1) i/c testingetc complete as reqd. |
| 31 | 3Cx10 Sq.mm. |
| 32 | 3Cx4 Sq.mm. |
| 33 | Laying of one number PVC insulated and PVC sheeted/XLPE power cable of 1.1 KV grade of following size in the existing RCC/HUME/Metal/DWC/HDPE pipe as required.Up to 35 Sq.mm |
| 34 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 35 | Supplying and fixing PVC batten/ angle holder including connections etc. as required. |
| 36 | SITC of energy efficient (Minimum 3 star BEE rating) 9/10 watt LED bulb B22 base suitable to operate on 230 V 50 Hz AC Supply with lumens output not less than 850 Lm, Lamp Life Hours 15000, CRI> 80, Rated Efficacy> 90, In Built Surge Protection 4 KV etc complete as required. |
| 37 | SITC of Static Energy Meters tamper proof,Projection Mounted, Poly Carbonate Body with LCD type display, 50Hz, 240V, AC Single Phase, Accuracy Class 1.0, rating 5-30A, kWh Compact Meter with Sealing Screw provision complete as required. |
| 38 | SITC of 3 mm thick phenolic laminated sheet i/c cutting, shaping, painting, fixing & providing screw, washer, nuts etc complete as per site requirement. |
| 39 | Supplyingandfixing of MCB Enclosure Plastic Powder Painted MCB DBs with Din Rail confirming to IS:13032/ IS:8623 i/c connection testing etc complete as required. |