| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil as per DSR No. 2.8.1 |
| 2 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering1:4:8 (1 cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) Complete al as per DSR 4.1.8 |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth ,in proportion 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) DSR No 5.1.2 (Reinforced Cement Concrete) |
| 4 | R/F cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement . as per DSR NO. 5.2.2 |
| 5 | Centring and shuttering including strutting, propping etc. and removal of form work for Lintel beam,plinth beam;column, footing, bases for columns etc. as per complete DSR. NO. 5.9.5 |
| 6 | Brick work with common burrnt clay. F.P.S. (Non Modular) bricks 1:4 Cement & C/Sand mix mortar in foundation and plinth in all respect Complete all as per DSR 6.1.1 |
| 7 | Brick work with common burrnt clay. F.P.S. (Non Modular) bricks 1:4 Cement & C/Sand mix mortar in super structure all respect Complete all as per DSR 6.4.1 |
| 8 | 12 mm thick cement plaster of mix 1:4 ( 1 cement & 4 coarse sand Complete all as per DSR .No 13.4.1 |
| 9 | Providing and applying white cement based putty of average thickness brand and manufacture over the plastered wall surface to prepare the surface even and smooth complete all as per DSR 13.80 |
| 10 | Distmpring two coat with oi; bound distemper of approved brands & manufacturer Complete all as per DSR 13.41.1 |
| 11 | Finising walls with Acrylic Smooth exterior paint of required shade New work (two or more coat applied @ 1.67 ltr/10 Sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) Complete all as per DSR 13.46.1 |
| 12 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer.Complete al Complete all as per DSR10.2 |
| 13 | Steel reinforcement for R.C.C work including straihtening, cutting, bending, placing in position and binding all complete as per DSR NO. 5.22.6 |
| 14 | Painting or varnishing work in small areas or new wood work with one coat (upto one square metre of ready mixed priming paint and one coat of approved Complete all as per DSR13.53 |
| 15 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).DSR 11.47.2 Size of Tile 600x600 mm |
| 16 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.DSR 8.31 |
| 17 | 1:2:4 (1 cement : 2 Coarse sand (zone-iii) derived from netural sources stone aggregate 20 mm nominal size derived form natural sources ) complete All as per DSR 4.2.3 |
| 18 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid Complete all as DSR 17.3.1 |
| 19 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps DSR 17.7.1 |
| 20 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge 15 mm nominal dia Pipes metre DSR 18.8.1 |
| 21 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge 20 mm nominal dia Pipes metre DSR 18.8.2 |
| 22 | Providing and fixing on wall face unplasticised Rigid PVC water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes. 110 mm diameter DSR 12.41.2 |
| 23 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour DSR No. 17.73.1 |
| 24 | Providing and fixing ball valve brass of approved quality, high or low pressure, with plastic floats complete 20 mm nominal bore DSR 2023 SI. No- 18.18..2 |
| 25 | Providing and fixing brass bib cock of approved quality, 20 mm nominal bore DSR 2023 SI. No- 18.15.2 |
| 26 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. DSR 2023. SI.No. 17.31 |
| 27 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS: 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.. DSR 2023. SI.No- 18.48 |
| 28 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface I recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. As per DSR E&M Ser No1.1.2 Group B |
| 29 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq.mm + 1 X 2.5 sqmm earth wire As per DSR E&M Ser No 1.14.2 |
| 30 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4. sq.mm + 1 X 4 sqmm earth wire As per DSR E&M Ser No1.14.3 |
| 31 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. As per DSR E&M Ser No 1.25 |
| 32 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. As per DSR E&M Ser No 1.31 |
| 33 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch. connections etc. as required. As per DSR E&M Ser No 1.32 |
| 34 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providingand fixing 25 A modular socket outlet and 25 A modular SP MCB, \"C\" curve including connections, paintingetc. as required.As per DSR E&M Ser No 1.57 |
| 35 | Supply and fixing of 12-15 Watt LED Down lighter (SMD Type) (System lumen efficacy >135 lm/Watt) Supplying, installation, testing &Commissioning of LED Recessed/surface Down lighter (Round /squre/Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement. Powder coated dia cast /Extruded aluminium Body including trim. complete all as per DSR E&M 8.3.3 |
| 36 | Supply and fixing of Bruh Less Direct Current (BLDC) mortar supply, Installation, Testing and Commissioning of celling fan with Brush Less Direct Current (BLDC) mortar, class of insulation: B, 3 nos.metal (Aluminum alloy) blades, 30 cm long down rod 2 nos. cogylator nopies, shackle kit, safety rope, copper winding, steel/al bodypowr Factor not less than 0.9, Service Value (CM/M/W) minimum as below. 350 RPM (tolerance as per IS : 374-2019), THD (total Harmonic Distortion) less than 10%, suitable for operation with regylator for speed control and all remaining accessories with including safety pin, nut bolts, washers, temperature rise=75 degree C (max) insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Celling Fan compliant to IS 374:2019 fan Supply, earthing etv. complete all as per DSR E&M 9.2.2 |
| 37 | S/F Information /sign board i/c all comp. at site. |
| 38 | ADD GST 18 % Please Enable Macros to View BoQ information |