| 1 | Taking down shutter of any description exc 2 Sqm mtr each complete all as specified and as directed. |
| 2 | M &L for cutting holes in stone wall built in cement mortar or in cement lime mortar exc one brick exc 2 brick complete all as specifed and as directed. |
| 3 | M &L for framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, doors stec to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exc or steel heteeing or other covering, running rails and guides) and hanging, also fastining and fixing complete comforming to FE410W (Gde: E250) qulity complete all as specified and as directed. |
| 4 | M & L for mild steel plain block sheet 1.25 mm thick in hearths covering to door shutters covering to door chowkats (frames) chullah haoods, water tank, water troughs, ducts, urinal troughs and funnels, etc., cut to size edges beaded if dirtected, holes punched including rough headed screws clout nails or revets and fixed to wood or steel members etc., with plain 40mm lap joints or welded/reveted seams including bending, turning up, mitred angles, stopped ends, outlets etcas required complete all as specified and as directed. |
| 5 | M & L for rendering 15mm thick in CM 1:6 on fair faces of brick / concrete finished evern and smooth without using extra cement complete all as specifed and as directed. |
| 6 | M& L for two coats of cement base paint to walls sufaces over a coat of cement primer incl preparation of new wall surface complete all aspecifed and as directed. |
| 7 | Excavation in trenches n.exc. 1.5 m wide and n.exc. 1.5 m in depth for foundation or manholes etc., and area n.exc. 10 Sq.m on plan and getting out in hard/dense soil complete all as specified and directed. |
| 8 | Excavation in trenches .exc. 1.5 m wide and n.exc. 3 m in depth and getting out in soft /loos soil complete all as specified and directed. |
| 9 | Demolition and breaking up drain pipes(salt glazed stone ware) set in cement mortar of internal diaof pipe150mm and disposing of broken pipes complete all as specified and directed. |
| 10 | Demolition and breaking up drain pipes(salt glazed stone ware) set in cement mortar of internal diaof pipe200mm and disposing of broken pipes complete all as specified and directed. |
| 11 | M & L for reinforcement concrete pipes, class NP3 150mm bore, laid and jointed complete with collars etc complete all as specified and as directed. |
| 12 | M & L for reinforcement concrete pipes, class NP3 200mm bore, laid and jointed complete with collars etc complete all as specified and as directed. |
| 13 | M &L for cement concrete bed in (1:3:6) type C2 (using 40 mm graded crushed stone aggregate) to drain pipeincluding packing under and haunching against the sides of the pipe after they are laid and tested for the 150 mm bore of pipe complete all as specifed and as directed. |
| 14 | M &L for cement concrete bed in (1:3:6) type C2 (using 40mm graded crushed stone aggregate) to drain pipeincluding packing under and haunching against the sides of the pipe after they are laid and tested for the 200 mm bore of pipe complete all as specifed and as directed. |
| 15 | Returning, filling in including spreading leveling watering and well ramming in laywers not exc 25 cms thick in soils complete all as pecified and as directed. |
| 16 | Removing excavated materal / soils to a distance exc 50 mtr and not exc 250 mtrs depositing where directed at a level not exc. 1.5 mtr above the starting point complete all as specifed and as directed. |
| 17 | M & L forproviding cement concrete (1:2:4) type B-1.(using 20mm graded crushed stone aggregate) as in benching inside manholes,copings, in floors as per requirement including all necessary form work complete all as specified and as directed. |
| 18 | Demolition of brick work or stone masonry any type built in cement mortar complete all as specified and as directed. |
| 19 | M & L forbrick work with subclass \"b\" bricks straight or curved on plain exc 6c mean radius built in cm 1:4 etc complete as specified and directed. |
| 20 | M&L for rendering 15mm thick in CM 1:4mixed with Water proofing compound @ 3% of the weight of cement used or as per manufacturer\"s instruction on fair faces of brick work or concrete surfaces on walls finished even and smooth without using extra cement etc complete as specified and as directed.Note:-WPC shall be measured and paid separately under relevant item. |
| 21 | Supply only liquid water proofing compoundcomplete as specified and as directed. |
| 22 | M & Lfor precast RCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) in cover slabs set in cement mortar 1:6 including all necessary form workNote:-Reinformcement shall be measured and paid separately under relevant item. |
| 23 | M & L for TMT steel bars 10 mm dia over cut to length bent to shape required including craking bending spirally, hooking ends and binding with mild steel wire (annealed ) not less than 0.90 mm dia as in reinforcmentcomplete all as specified and as dirtected. |
| 24 | M & L forsoakage wells excavation, any type of soil, foundation in PCC 1:3:6 walls of honey combed masonary with top ring of M25 concrete including intercepting chamber and screen chamber made of brick masonry in CM RCC cover slab in M25/SFRC cover interconnecting pipes of RCC/DWC filled with brick bats of size 3.00 mtr dia X4.5 mtr effective depth as per Drg No AFB/TD/125 Sht 1/2 & 2/2 etc complete all as specified and as directed. |
| 25 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm,complete as specified and as directed. |
| 26 | M&L for PCC (1:3:6) type C2 (Using 40mm graded crushed stone aggregate) as in foundation filling and mass concretecomplete as specified and as directed.. |
| 27 | S&F for steel work in tublar trasses including special shaped washers etc complete using ERW or induction but welded tubes conforming to IS 1161-1979 grade 240 |
| 28 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated/semi corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified. |
| 29 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 30 | M&L for preparation of new steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer complete all as specified and directed. |
| 31 | S&F for Mild steel bolts purpose made with hexagonal or Square head one end and screwed the other, or screwed both ends each screwed end to be fitted with washers and one hexagonal or square nut with washers exc 25 cm long and dia of neck exc 12mm n.exc 20mm.complete as specified and as directed. |
| 32 | Supply, install, testing and commissioning of energy efficient split type air conditionerindoor/outdoor units complete all as specified and directed by E-In-charge.ISEER: 5 StarTonnage rating : 1.5TRCompressor: Inverter type Condenser material : CopperBlower motor winding : CopperCondenser fan motor winding : CopperOperation sound : Not more than 60 dbRefrigerant : R32Indoor unitand out door unit connection pipe material: CopperAir flow rate : Not less than 700 CFMSwing : 2 wayMaximum cooling capacity: Not less than 5000 WattsMinimum cooling capacity: 1500 WattsPower supply: Single phase 230 V, 50 HzEvaporative fins : Hydrophilic finsFilters : Anti dust with anti MicrobialRemote: LCD DisplayTemperature setting range: 16 to 30 degreeCelsius Maximum ambient tperature:52 degrees celsiusMaximum piping capability: 15 MtrsThermostat : Anti freeze typemarking of MES number on ceiling fan by stamping with ink print oflettering frame size Length 20cm width 2.5 cm \"MES-12345 AGE E/M (SOUTH)\" at least two sides on AC Make: Voltas-185V Vertis smart Elite Gold (4503702)/Carrier-Xtreme Lumo Exi (5 star flexi cool inverter)/Blue star-IC518SNUR-S Series-Inverter split AC 1.5TR 5 star /Hitachi-RAS.E518PCBIB |
| 33 | S&F Voltage stabilizer for automatic operation single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of (+/-)2.5% and of capacity 4 KVA, marking of MES number on ceiling fan by stamping with ink print oflettering frame size Length 20cm width 2.5 cm \"MES-12345 AGE E/M (SOUTH)\" at least two sides on stabilizer complete all as specified and as directed.Make:Sinetrac-WMD4000UT140 to 280V/Volina-S.No-5-4.0KVA-140-280V/Microtech-PEARL EM 4140+PLUS |
| 34 | S & F sheet metal enclosure single pole and neutral enclosure with two pin and earth plug and socket complete with one single pole MCB 20 Amps capacity complete all as specified and directed. |
| 35 | M & L Submain wiring with 2 runs of single core 4 sqmm PVC insulated FRLSH multistranded 1100 volts grade wire, copper conductor drawn through and including non-metalic rigid PVC conduit and conduit accessories of medium grade not not less than 25mm dia including one run of single core 4 sqmm PVC insulatedsheated multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DBcomplete all as specified and as directed. |