| Sl. No. | Item Description |
| 1 | B & R Division Items |
| 2 | Demolition of un-reinforced cement concrete in ground floor and paving not exceeding 15 cm thick (below or above ground level) complete all as specified and directed. |
| 3 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 4 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc. complete all as specified and as directed. |
| 5 | Dismantling floor, hearth or wall tilling including cement mortar bedding (but not backing) removing serviceable tiles to stores and rubbish off the premises. |
| 6 | Dismantling mild steel work or wrought iron of any description and in any position complete all as specified and as directed. |
| 7 | Dismantling plain or corrugated steel sheeting, any gauge or any thickness as in roof covering, wall cladding, etc.including all necessary staging / scaffolding, etc. as required complete all as specified and as directed. |
| 8 | Dismantling wall and ceilingboards (fibre, pulb, insulation etc) or insulation boards slabs/blankets any thickness including cover fillets all as specified and as directed. |
| 9 | Taking down cement plaster on brick or stone walls etc, including raking out joints, hacking for key scrubing down with water etc complete all as specified and as directed. |
| 10 | Taking down chowkhats or frame with shutters (without taking off shutters from frame) each not exceeding 1.50 Sqm each complete all as specified. |
| 11 | Taking down Chowkats or frames with shutters exceeding 1.5 Sqm but not exceeding 4 Sqm each (without taking off shutters from the frame) complete all as specified. |
| 12 | Taking up or down 15mm diaGI steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed. |
| 13 | Taking up or down 20mm diaGI steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed. |
| 14 | Excavating in post holes each n exc 0.5 cum, getting out, in soft /loose soil, ramming earth filling or borken rubble mixed with earth around in layers nexc 25 cm watering and removing ssurfaces soil to distance nexc 50 m and making good surfaces all as specified and directed. |
| 15 | M&L for PCC (1:4:8), Type D2 using 40 mm graded stoneaggregate as in foundations, sub-base,filling and mass concrete complete all as specified. |
| 16 | M&Lfor providing 75 mm thick cement concrete (1:4:8) type D-2 using (40mm gradedstone aggregate) as in Sub base of floor rough surface for receiving tile complete all as specified. |
| 17 | M&L for plain cement concrete 1:3:6type C2 (40mm gradedaggregates) in foundation filling and mass concrete complete all as specified & as directed . |
| 18 | M&Lfor providing 75 mm thick plain cement concrete (1:3:6) type C-2 using (40mm gradedstone aggregate) as in Sub base of floor, flooring, pavings ad similar work complete all as specified. |
| 19 | Material & labour for providing precast cement concrete 1:3:6, Type C1, using 20mm graded stone aggregate as in window or door Cills, lintels, bressummers, steps, quoin blocks [for use with masonry], string courses, copings. kneelers, apex stones, pier caps, columns, posts,bond stone boundary pillars, bed plates, pintle blocks, anchorage blocks, bonders [for stone walling], corbels, brackets, etc. [of any section indicated], with plain fair faces, including chamfers, weatherings, throating etc. and setting in mortar 1:4 complete with joints to matchcomplete all as specified and as directed. |
| 20 | M & L for plain cement concrete (1:2:4) type B1 using 20mm graded aggreagate as in bed blocks, coping , cills, steps, kneelers, bed plates, apex stones kerbs and similar works including necessary formwork complete all as specified and directed. |
| 21 | M&L for PCC type B-2 1:2:4 (Using 40mm graded aggregate) as in surface channel and drain complete all as specified & directed. |
| 22 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends foretccomplete all as specified and directed. |
| 23 | M&L for 25mm thick plain cement concrete 1:2:4 type B-0,(Using 12.50 mm graded agg.) as in floors all as specified and directed. |
| 24 | Material and labour for precast autoclaved acrated concrete bricks (AAC) block masonary with 150mm thick with grade -I, AAC block of density 551 to 650kg/cum conformimg to IS-2185 (Part -III) i super structure above plinth level upto floor V level with RCC bend at sill level and lintel level with approved block laying polymer modified adhesive mortar complete all as spd and directed. Note : RCC bend and reinforcement shall be measured and paid separately |
| 25 | Use and waste formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter rough finished flat surfaces of concrete complete all as specified and as directed. |
| 26 | Use and waste formwork to sides and soffits of floor or roof beam, beam hunching, girder, lintels, cantilever, shelves including supports etc for rough finished flat surfaces of concrete complete all as specified and directed |
| 27 | Use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished flat surfaces of concreteall as specified and directed. |
| 28 | Material and labour for providing Reinforced Cement Concrete (Nominal mix) (1:1.5:3) type A1 using 20 mm graded aggregate as in foundation including rafts, footings,foundationbeams, plinth beams, bases of columns etc all as specified and directed. |
| 29 | Material and labour for providing Reinforced Cement Concrete (Nominal Mix) 1:1.5:3 type A1using 20 mm graded aggregate as in columns, pillars, piers, posts and struts complete all as specified and directed. |
| 30 | Material and labour for providing Reinforced Cement Concrete (Nominal Mix) 1:1.5:3 type A1 using 20 mm graded aggregate as in beams, cantilever, lintels over 1.5 m complete all as specified and directed. |
| 31 | M & Lfor 10mm dia and over TMT bars, cut to length bend to shape as required including cranking, hooking etc and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed. |
| 32 | M & Lfor 6mm to 8mm dia and over TMT bars, cut to length bend to shape as required including cranking, hooking etc and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed. |
| 33 | M & Lfor Mild Steel TMT Bar 6mm dia and over up to 10 mm dia as in stirrups, spacers and binders as required including cranking, hooking etc and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed |
| 34 | Material & labour for walling of random rubble masonry, uncoursed, well bonded, bedded and solidly hearted for retaining wall, abutments and similar work, built in Cement Mortar 1:6 with use of precast PCC bond complete all as specified and directed. |
| 35 | Material & labourfor Raised Pointing in Cement Mortar 1:3 to random rubble uncoursed or brought up to coursed masonry complete all as specified and directed. |
| 36 | M & L for brickwork with subclass \"B\" or locally available best qualityold size bricks, straight or curved on plan exc 6 m mean raduis,built in CM (1:6) complete all as specified and directed. |
| 37 | M & L for half brick work in cement mortar (1:4) straight or curved on plan to any radius with locally available Subclass ‘B’ old size best quality bricks all as specified . |
| 38 | Material and labour for 12 mm thick renderingin cement mortar 1:6 on fair faces of brick wall or concrete surfaces, finished the surfaces even and fair complete all as specified. |
| 39 | Material and labour for 15 mm thick rendering in cement mortar 1:4 on fair faces of brick wall or concrete surfaces, finished the surfaces even and fair without using of extra cement complete all as specified.Note:- WPC shall be measured and paid separately. |
| 40 | Material and labour for 15 mm thick rendering in cement mortar 1:4 on fair faces of brick wall or concrete surfaces, finished the surfaces even and fair with using of WPC complete all as specified. Note:- WPC shall be measured and paid separately. |
| 41 | Supplied only integral waterproofing compound etc complete all as spd and directed. |
| 42 | M & L for Vitrified Ceramic tiles light shade10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or colored cement to match includingscreed bed or bedding layers 15 mm thick in cement mortar (1:4) for laying floor finishes complete all as specified and directed. |
| 43 | M & L Non Skid ceramic tiles colour 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.06 but not exceeding 0.11 sqm, as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including 15 mm thick screed bed or bedding layers in cement mortar 1:6 over brushing with neat cement slurry as specified |
| 44 | M & LGlazed ceramic coloured tilesin vertical surface size 450mm x 350mm x & ( 6mm to 7mm )mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over & including10mm thick screed bed or backing coat in cement mortar 1:4layingof skirting/dado on walls all as specified and directed. |
| 45 | Supply and fix pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. |
| 46 | Supply and fix pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. |
| 47 | Supply and fix Framed work such as grills, gratings, etc.. with ends of bars or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 48 | Supply and fix Steel work in trusses, purlins, posts and the like using tubular/ square hollow sections including special shaped washer etc. complete using ERW or induction butt welded tubes/SHS conforming to IS.1161 - 2014 / IS.4923 - 1997 grade St.-240 complete all as specified and directed. |
| 49 | Supply and fix 5 mm thick mild steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment conforming to Fe 290 grade E-165 complete all as specified. |
| 50 | Supply and fix mild steel screw bolts (machine made) of 11 mm to 15 mm dia with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut,length of bolt exceeding 10 cm but not exceeding 15 cm complete all as specified. |
| 51 | S & F bands, straps,clamps,cleats & small articles, supports or stays for rainwater,ventilating pipes, including bolts etc conforming to Fe-290 Gde-E-165 all as specified and directed. |
| 52 | S & F Pressed steel frames made of 1.25mm thick MS sheet of profile 125x60mm for door and window frames with one or more rebates includinghinges, lock strike plate, shock absorber, treating of internal surfaces of chowkhats with coal tar or black paint including hinges, hold fasts/lugs etc complete all as specified. |
| 53 | S&F 2nd class hard woodglazed andskeleton door shutters 35 mm thick open rebated and prepared to receive glass, guage etc (withoput sash bars), edge of framing plain chemfered ro rounded fitted with cut and mitred beds for securing glass etc size of members of shutter as specified in SSR Part I section 8 clause 8.20(a) complete all as specified and directed. |
| 54 | S & F 30 mm thick Second class Hardwood Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats, complete all as specified. |
| 55 | S & F Solid PVC door frame of size 50 mm x 47 mm made of 5 mm plain colour PVC sheet reinforced with mild steel square tube complete all as specified in clause 8B.3.1 and shown on page 150 of MES Schedule Part-II (2010). |
| 56 | S & F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and wood grain printed PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of wood grain printed sheet, 15mm wide x mm thick PVC sheet beading used inside stiles and rail and decorative PVC beading of 10mm x 10mm (90 degree), used solvent cement, supply and fixing in the frame at site as per clause 8 B.2.1 of MES schedule Part-II (2004) complete all as specified. Make: Rajshri or equivalent as approved. |
| 57 | Supply and fix 3 ways sliding anodized aluminium glazed window shutter with frame with the following specification complete all as specified & directed. (a) Window frame 50mm X 65mm X 1.5mm thick(b)35mmX 35mm X1.5mm Z section stiles, rails (c) 35mm X 35mm X 1.5mm T section million (d) PVC gasket with 4mm thick tinted glass, alumninium alloy wire cloth 0.45mm nominal dia incl. aluminium handles with necessary locking arrangement |
| 58 | Supply and fix anodized aluminium glazed ventilators shutter top hung/fixed type with frame consists of following specification complete all as specified and directed. (a) Window frame 50mm x 65mm x 1.5mm thick(b)35mm x 35mm x 1.5mm Z section stiles, rails (c) 35mm x 35mm x 1.5mm T section million (d) PVC gasket with 4mm thick tinted glass, incl. aluminium handles with necessary locking arrangement |
| 59 | Supply and fixStainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified. |
| 60 | S&F 100mm MS Butt hinges, medium weight, cold rolledcomplete all as specified. |
| 61 | Supply and fix 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixedcomplete all as specified. |
| 62 | Supply and fix 150 mm long aluminium handles cast type anodised complete all as specified & directed . |
| 63 | Supply and fix 200 mm long aluminum anodised barrel tower bolts of extruded section complete all as specified and directed. |
| 64 | Supply and fix 150 mm length floor door stopper of brass body and tongue, anodised with hard drawn steel spring fixed in floor overall length of cover plate 150mm etccomplete all as specified and directed. |
| 65 | S&F as in repairs 25 mm dia and 1mm thick MS chromium platedcurtain rods with fixing side fancy type brackets end knobs fixed with steel screws etc all as specified and directed . |
| 66 | Supply and fix as in repair vitreous china Squatting pan, \"Orissa\" pattern, Size 580 X 440mm ,with integral foot rests (excluding flushing ciestern and flush pipe) incl necessary lime concrete and 100 mm bore cast iron \"P\" trap with 550 to 600mm long neck for connecting WC to branch piece with cement joints complete all as specified & as directed . |
| 67 | Supply & Fixed as inrepairsVitreous china wash down water closet pan ( pedestal pattern ) , whitewith P or S trap incl. seat cover but excluding fixing bolts, flushing cistern and flush pipe complete all as specified and as directed. |
| 68 | Supply and fix vitreous china wash basin, white, wall hung basin full pedestal with fixing accessories , size 560 X 430 X 195 mmincluding waste coupling and excluding taps, waste ,chain and plug and porcelain stoppercomplete all as specified. Make:Jaquar Catalouge No- CNS-WHT-811 and Equivalent as per approved list of make) |
| 69 | S & F as in repair PVC valveless,syphonic action type,low level flushing cistren 10 ltr capacity ISI Marked incl all acessories and 32mm dia PVC flush / discharge pipe incl float valve, inlet complete all as specified. |
| 70 | S&F sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed. |
| 71 | S & Fvitreous china soap dish chromium plated approx. size 160mm x 160mm x 90mm fixed to plug complete all as specified. |
| 72 | S & F in repair PVC connections 15 mm size with PTMT nuts of length 450 m complete all as specified. |
| 73 | M&L as in repair for water connection pipe for hot and cold water application, steel armoured of length not less than 600mm suitable with brass union on both sides to fixed 15mm bore GI pipe for geyser functioning complete all as specified and directed. |
| 74 | M&L water connection pipe for hot and cold water application, steel armoured of length not less than 600mm suitable with brass union on both sides to fixed 15mm bore GI pipe for geyser functioning complete all as specified and directed. |
| 75 | S & F 15mm bore pillar tap cast copper alloy with capstan head, fancy type, chromium plated, concealed screwed down high pressure with or without hot or cold with long shunk screwed shanks and fly nuts screwed for iron pipes and connecting to water pipe line complete all specified and directed. |
| 76 | Supply and fix as 15 mm bore bib taps fancy type, chromium plated, castcopper alloy with crutch or butter fly handle, screwed down, screwed for iron pipe or for brass ferrule all as specified. |
| 77 | Supply and fix 15mm bore stop valve/angle valve, cast copper alloy cromium plated fancy type screwed down high pressure, with crutch or butterfly handle for 15 mm bore pipe or for unions all as specified. |
| 78 | Supply and fix Towel rail, 20mm dia brass chromium plated, 600mm long with fancy type brass chromium plated brackets on both sides and fixed with steel screws and wooden/rawl plugs as in repair complete all as specified. |
| 79 | Supply and fix CP health faucet with or without swivel joints for 15mm pipe with 1 mtr long easy flex tube in chrome finish with wall hook/hanger PTMT etc complete all as specified and directed.Make : Hindware cat part No F 160027 or equivalent as per approved list of make |
| 80 | Supply and fix CP towel rail 600mm long fixed with and including CP brass screw and wooden/ plastic cleats (min wt 170 gram) complete all as specified and directed. |
| 81 | Supply and fix CP toilet paper roll holder with flap (chrome) vitreous china white box type complete all as specified and directed.Make : Jaquar cat part No CAN-CHR-1153S or equivalent as per approved list of make |
| 82 | S & F 600mm X 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 83 | Supply and fix 32mm bore low density polyethylene pipes (LDPE) of pressure rating 6kgf/qcm to wall ceiling or in floors etc complete all as specified and as directed. |
| 84 | Supply and fixeaves gutters 110 mm borePVC (SWR) Pipe single socketed in any length with rubber ring joints, fixed in wall complete all as specified. |
| 85 | Supply and fix 110mm diaPVC (SWR) pipes single socketed, in any length, laid in trenches or in floors / fixed to walls complete all as specified. |
| 86 | Supply and fix 75mm diaPVC (SWR) pipes single socketed, in any length, laid in trenches or in floors / fixed to walls complete all as specified. |
| 87 | Supply and fix 50mm diaPVC (SWR) pipes single socketed, in any length, laid in trenches or in floors / fixed to walls complete all as specified. |
| 88 | Supply and fix 110mm dia PVC (SWR) bend suitable for pipe complete all as specified. |
| 89 | Supply & Fixed 110mm dia PVC (SWR) reducer suitable for pipe complete all as specified. |
| 90 | Supply & Fixed 75mm dia PVC (SWR) vent cowl suitable for pipe complete all as specified. |
| 91 | Supply & Fixed 110mm dia PVC (SWR) WC connector with lip ring suitable for pipe complete all as specified. |
| 92 | Supply & Fixed 110mm dia PVC (SWR) \"S\" trap suitable for pipe complete all as specified. |
| 93 | M & L75mm dia PVC(SWR) floor trap, outlet, plain with grating including jointing with solvent cement complete all as specified. |
| 94 | Supply and fix 110mm bore PVC (SWR) junction, single T equal or unequal with or without door access complete all as specified. |
| 95 | S&F 15mm bore steel water tubing, medium grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches required for water connections complete all as specified and as directed. |
| 96 | S&F 20mm bore steel water tubing, medium grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches required for water connections complete all as specified and as directed. |
| 97 | S&F gun metal gate valve 20mm dia, cast copper alloy, screwed down high pressure with crutch or butterfly handle screwed both ends for suitable iron pipe complete all as specified and directed. |
| 98 | Supplying, hoisting, fixing and connecting up 1000 litre rotational moulded polythylene water storage tanks double layer (cylindrical vertical with closed top), hoisted and fixed in position all as specified in SSR Part-I including connecting the overflow drain out, inlet and outlet pipes, tank nipple, elbow, bend, unions, sockets, etc. including taking down old damaged water tank and disposing off complete all as specified and as directed |
| 99 | Supplying, hoisting, fixing and connecting up 2000 litre rotational moulded polythylene water storage tanks double layer (cylindrical vertical with closed top), hoisted and fixed in position all as specified in SSR Part-I including connecting the overflow drain out, inlet and outlet pipes, tank nipple, elbow, bend, unions, sockets, etc. including taking down old damaged water tank and disposing off complete all as specified and as directed |
| 100 | S&F Ball valves high pressure of PTMT with epoxy coated aluminium rod & high- density plastic bal screwed for iron pipe and fixed (min wt 15mm-142gms/20mm-210gms/25mm- 455gms/40mm-690gms) for 25mm bore pipe complete all as specified and directed. |
| 101 | Material and labour for pre-painted designer false ceiling using E-grid 2430, 180 GSM (exposed ceiling suspension system ) of grid size 600 mm x 600 mm with main runner 38 mm x 24 mm and wall angle 24 mm x 24 mm using 4 mm thick High Pressure Non Asbestos Fibre Cement prepainted decorative board (E-Board Classic)in a grid of GI system duly suspended with 4 mmdia GI bar hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip providing positions for light fixtures, air conditioning diffuser and ducts ,sprinkler ,smoke detectors etc. The main runners to be secured to structural soffits by hanger @ 1220 mm maximum c/c. the last hanger at the end of each main runner should not be placed at more than 450 mm from the adjacent wall, Flush fitting 1220 mm cross tee to be interlocked between main runners @ 610 mm c/c,so as to form 600 mm x 600 mm grid and painted with two coats of acrylic emulsion paint of approved shed /make over a coat of cement primer before installing it on the grid complete all as specified . Make: Everest Industries Ltd or equivalent as per IS 14862. |
| 102 | M & Lfor preparation of old wall surfaces incl cornices and applying two coats of white wash complete all as specified and directed. |
| 103 | Material and labour for applying two coats of cement base paint over one coat of primer on plastered surfaces of walls including preparation of new or previously untreated surfaces all as specified and directed |
| 104 | Material and labour for applying two coats of cement base paint on old plastered surfaces of walls including preparation of old plastered surfaces all as specified and directed |
| 105 | Material and labour for preparation of new wall surfacesand applying two coats of oil bound distemper (white or tinted) over a coat of 1 mm thick wall putty over a coat of alkali resistance primer complete all as specified. |
| 106 | Material & Labour for preparation of new plastered surface applying two or more coats of 100% Premium acrylic emulsion paint@ 1.67 ltr/10 Sqm having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 litre/ 10 sqm complete all as specified. |
| 107 | Prepartation of old painted steel surfaces over 10 cm width or girth not otherwise described and applying two coat of synthetic enamel paint, complete all as specified and directed. |
| 108 | M & Lfor preparation of new wooden surfaces of any description not other wise described over 10 cm width or girth and applying two coat of Synthetic enamel paint over a coat of pink primer complete all as specified and as directed. |
| 109 | M & Lfor preparation of old wooden surfaces of any description not other wise described over 10 cm width or girth and applying two coat of Synthetic enamel paintcomplete all as specified and as directed. |
| 110 | M & Lfor preparation of old wooden surfaces of any description not other wise described over 10 cm width or girth and applying two coat of varnish paintcomplete all as specified and as directed. |
| 111 | E & M Division items |
| 112 | Taking down carefully copper/aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc includingremoving from site for taking credit and making good to disturbed surface of walls, floors etc as per existing specification complete all as specified and as directed. |
| 113 | M & L for point wiring with FRLSH stranded copper conductor 1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 markedin and including heavy duty, PVC casing caping including all accessories etc ISI marked, with PVC surface boxes suitable for fixing switches, sockets and regulators including PVC insulated FRLSH stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for One light point controlled by one switch. |
| 114 | M & L for point wiring with FRLSH stranded copper conductor 1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 markedin and including heavy duty, PVC casing caping including all accessories etc ISI marked, with PVC surface boxes suitable for fixing switches, sockets and regulators including PVC insulated FRLSH stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for One fan point/exhaust fan point controlled by one, one way switch 5 Amp. |
| 115 | M & Lfor point wiring with FRLSH stranded copper conductor4.0 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 markedin and including heavy duty, PVC Casing caping including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated FRLSH stranded copper conductor 4.0 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for one power point on independent board of AC/equipments etc controlled by one SP/SPN MCB. Note: The point wiring will be done from DBs to the switch sockets of any size with three wires running independently for each point and with no tappings. |
| 116 | M&L for point wiring with FRLSH stranded copper conductor1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 markedin and including heavy duty, PVC Conduit concealed of suitable size including all accessories etc ISI marked, with GI sheet pressed terminal box (recessed) with 3mm thick laminated hylem sheet top cover suitable for fixing switches, sockets and regulators including PVC insulated FRLSH stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for One light point controlled by one switch. |
| 117 | M&L for point wiring with FRLSH stranded copper conductor1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 markedin and including heavy duty, PVC Conduit concealed of suitable size including all accessories etc ISI marked, with GI sheet pressed terminal box (recessed) with 3mm thick laminated hylem sheet top cover for fixing switches, sockets and regulators including PVC insulated FRLSH stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for One ceiling fan point controlled by one, one way switch 5 Amp. |
| 118 | M&L for point wiring with FRLSH stranded copper conductor1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 markedin and including heavy duty, PVC Conduit concealed of suitable size including all accessories etc ISI marked, with GI sheet pressed terminal box (recessed) with 3mm thick laminated hylem sheet top cover for fixing switches, sockets and regulators including PVC insulated FRLSH stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for One exhaust fan point controlled by one, one way switch 5 Amp. |
| 119 | M&L for point wiring with FRLSH stranded copper conductor1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 markedin and including heavy duty, PVC Conduit concealed of suitable size including all accessories etc ISI marked, with GI sheet pressed terminal box (recessed) with 3mm thick laminated hylem sheet top cover for fixing switches, sockets and regulators including PVC insulated FRLSH stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed forOne 3 pin 5 Amp socket outlet point controlled by one switch on independent board. |
| 120 | M&L for point wiring with FRLSH stranded copper conductor1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 markedin and including heavy duty, PVC Conduit concealed type of suitable size including all accessories etc ISI marked, with GI sheet pressed terminal box (recessed) with 3mm thick laminated hylem sheet top cover for fixing switches, sockets and regulators including PVC insulated FRLSH stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for One 3 pin 5 Amp socket outlet point controlled by one switch on the same board. |
| 121 | M&L for point wiring with FRLSH stranded copper conductor4.0 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 markedin and including heavy duty, PVC Conduit concealed type of suitable size including all accessories etc ISI marked, with GI sheet pressed terminal box (recessed) with 3mm thick laminated hylem sheet top cover for fixing switches, sockets and regulators including PVC insulated FRLSH stranded copper conductor 4.0 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for one power point on independent board of AC/equipments etc controlled by one SP/SPN MCB. Note: The point wiring will be done from DBs to the switch sockets of any size with three wires running independently for each point and with no tappings. |
| 122 | S&Fmodular switch 1 way 6A/10A, 1 Module complete all as specified and directed. |
| 123 | S&Fmodular switch 1 way 16A/20A, 1 Module complete all as specified and directed. |
| 124 | S&Fmodular socket 6A/10A, 2/3 pin combined 2 module complete all as specified and directed. |
| 125 | S&Fmodular socket 16A/20A, 2/3 pin combined 2 module complete all as specified and directed. |
| 126 | S&F ceiling rose surface bakelite with three terminals all as specified and directed |
| 127 | S&F modular metal flush box 3 module with white cover plate with frame ISI marked complete all as specified and directed |
| 128 | S&F modular metal flush box 6 module with white cover plate with frame ISI marked complete all as specified and directed |
| 129 | M&L for submain wiring with two single core 10.0 sqmm PVC insulated unsheathed cable multi-strand copper conductor FRLSH drawn through and including PVC non metallic rigid Conduit concealed with all fittings and fixing accessories on roof, walls, ceiling etc including 1 x 6.0 sqmm PVC insulated FRLSH unsheathed multi strand copper conductor earth wire connecting earth including cutting groove for concealed wiring, making good to disturb surface of wall/floor with cement mortar and finishes to match existing incl taking out old existing submain wiring complete all as specified and directed. Note: Two run of single core cable, one run earth wire and one run PVC Conduit will be measured as one length. |
| 130 | Supply & Fix LED betten plastic type fitting of capacity 20W, operating on 230V, 50Hz, AC Supply having luminous efficacy of not less than 125 lumens/watts, CCT 6500K, P.F>0.9, 2.5 KV surge protection, 4-feet long, housing made out of extruded alluminium with decorative end caps elegently designed complete all as specified. |
| 131 | Supply & Fix enviromental friendly bldg security street light, LED luminaire 25 watt made up of pressure die cast alluminium body with mid power LED as lighting sources and PC cover having Top opening separate driver compartment with IP66 protection and impact resistance of IK07 including fixing arrangements and taking down old rusted bracket fittings completeall as per directed by Engr-in–charge. |
| 132 | Supply & Fix 25 watt new generation, post top, energy saving, envoiromental friendly long life aesthetically designed with symmetrical light distribution spun aluminium landscape lumiaire with high power (SMD) LED as lighting source with IP 65 protection including dismantling old one fittings completeall as per directed by Engr-in–charge. |
| 133 | Supply & Fix crown space post top lantern in soothing opal finish made up of polycarbonate material suitable upt o 15/2 watt LED lamp with roboust design and efficiant light distribution complete all as per directed by Engr-in–charge. |
| 134 | Supply & Fix new generation energy saving environment freindly long life LED flood light 70 watt made up of pressure die cast aluminium housing with high power LED and secondary lenses with IP 66 protection system efficiancy >11 LPW with 10 kv built in surge protection device including dismantling old one fittings completeall as per directed by Engr-in–charge. |
| 135 | Supply & Fix new generation 10 watt sturdy LED bollard of 1mtr height with excellent light output through its PMMA window, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, landscape luminaire with high power LES as lighting source IP 65 protection, fixed to groun by means of 4 nos M10 bolts including dismantling old one fittings completeall as per directed by Engr-in–charge. |
| 136 | Supply & Fix new generation decorative post top for 360 degree indirect light LED 40 watt with IP65 protection resistant to impact and corrosion glare free and better uniformity including dismantling old one completeall as per directed by Engr-in–charge. |
| 137 | Supply & Fix 10 watt IP 65 rated pyramid tripod type LED bollard with soft 360 degree light distribution including fixing arrangement including dismantling old one completeall as per directed by Engr-in–charge. |
| 138 | Supply & Fix surge protection device 10 KV as per existing one including dismantling old one completeall as per directed by Engr-in–charge. |
| 139 | Supply & Fix LED street light driver 30 watt to 100 watt as per existing one including dismantling old one completeall as per directed by Engr-in–charge. |
| 140 | S&F bldg security street light, LEDluminaire 60 watt made up of pressure die cast alluminium body with mid power LED as lighting sources, efficiancy > 120 LPW with 10KV SPD and PC cover having Top opening separate driver compartment with IP66 protection and impact resistance of IK07 including fixing arrangements complete incl dismantling old oneall as per directed by Engr-in–charge. |
| 141 | S&F bldg security street light, LEDluminaire 45 watt made up of pressure die cast alluminium body with mid power LED as lighting sources, efficiancy > 120 LPW with 10KV SPD and PC cover having Top opening separate driver compartment with IP66 protection and impact resistance of IK07 including fixing arrangements complete incl dismantling old oneall as per directed by Engr-in–charge. |
| 142 | S&F bldg security street light, LEDluminaire 25 watt made up of pressure die cast alluminium body with mid power LED as lighting sources, efficiancy > 120 LPW with 10KV SPD and PC cover having Top opening separate driver compartment with IP66 protection and impact resistance of IK07 including fixing arrangements complete incl dismantling old oneall as per directed by Engr-in–charge. |
| 143 | S&F Angle bracket of GI Pipe light grade 40mm dia for fixing building security light, 1 mtr long bent to shape 45 degree for fixing of security light including MS clamps of suitable size including nuts, bolts complete incl taking out old one all as specified and directed |
| 144 | S&F plastic body exhaust fan 250 mm sweep complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, copper winding and connecting to ceiling rose with 1.50 sqmm flexible pvc copper cable including making holes on the wall and making good to the disturbed surfaces complete all as specified and as directed. |
| 145 | S&F BLDC ceiling fan 1200mm sweep complete with blades, down rods and accessories, 230 V, min air delivery 210 CFM with service value 6.00 BEE 5 star rated & provn of ‘S’ type fan hook complete all as specified and directed. |
| 146 | Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection pipe etc complete all as specified and as directed. |
| 147 | S&F outdoor type, weather proof, PVC / thermoplastic polycorbonate cable junction box of size not less than 205mm X 255mm X 112mm to be fixed on circular steel pole including fixing arrangement with 2-4mm MS clamps and nut bolt of suitable size and comprising of PVC connector including dismantling old one complete all as specified and directed. |
| 148 | S&F sheet metal enclosure powder coated three phase and neutral DB for fixing of MCBs, 4 way double door with bus bar includinggrouting on the wall by means of screws and rawal plugs and making good disturbed surfaces complete all as specified and directed. |
| 149 | S&F sheet metal enclosure powder coated single phase DB for fixing of MCBs, 8 way double door with bus bar includinggrouting on the wall by means of screws and rawal plugs and making good disturbed surfaces complete all as specified and directed. |
| 150 | S&F MCB TPN of capacity 63 Amps ,240 V, 10 KA \"B\" curve complete all as specified and directed. |
| 151 | S&F MCB SPN of capacity 32 Amps,240 V, 10 KA \"C\" curve complete incl taking down old one all as specified and directed. |
| 152 | S&F MCB SP of capacity 5-32 Amps,240 V, 10 KA \"C\" curve complete all as specified and directed. |
| 153 | Supplying laying jointing and teting GI tubes 50mm bore light grade with all fittings and fixed to walls or laid under road for passing cables or used as pole for installation of LED post top lantern, single point air termination rod for lightening conductor support complete including dismantling old one complete all as specified and directed. |
| 154 | Supplying laying jointing and teting GI tubes 40mm bore light grade with all fittings and fixed to walls or laid under road for passing cables or used as pole for installation of LED post top lantern, single point air termination rod for lightening conductor support complete including dismantling old one complete all as specified and directed. |
| 155 | Supplying laying jointing and teting GI tubes 25mm bore light grade with all fittings and fixed to walls or laid under road for passing cables or used as pole for installation of LED post top lantern completeincluding dismantling old one complete all as specified and directed. |
| 156 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors conforming to IS-7098 (ParI)-1988, 1100 volts, grade cross sectional area 10 sqmm 2.0 core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed.Note :-(Excavation and earth work, bricks, sad cushioning and GI Pipe will be measured and paid separately under respective items) |
| 157 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors conforming to IS-7098 (ParI)-1988, 1100 volts, grade cross sectional area 10 sqmm 2.0 core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed.Note :-(Excavation and earth work, bricks, sad cushioning and GI Pipe will be measured and paid separately under respective items) |
| 158 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors conforming to IS-7098 (ParI)-1988, 1100 volts, grade cross sectional area 10 sqmm 4.0 core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed.Note :-(Excavation and earth work, bricks, sad cushioning and GI Pipe will be measured and paid separately under respective items) |
| 159 | Supply, fixing, commissioning & testing of PVC flexible copper cable 1.5 sqmm 3 core from cable junction box to street light fittigs, security light fittings, flood light fittings, lamp posts etc complete all as specified and directed. |
| 160 | M&L for earth continuity conductor by using20 mm x 3 mm copper earth stripor main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. with usig saddles/ fasteners/ insulators and fixing screws complete and including taking down old stripcomplete all as specified and directed |
| 161 | M&L for earth continuity conductor by using25 mm x 4 mm galvanized iron earth stripor main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. with usig saddles/ fasteners/ insulators and fixing screws complete and including taking down old stripcomplete all as specified and directed |
| 162 | M&L for earth continuity conductor by using32 mm x 6 mm galvanized iron earth stripor main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. with usig saddles/ fasteners/ insulators and fixing screws complete and including taking down old strip complete all as specified and directed |
| 163 | Taking down and refixing of serviceable earth continuity conductor of any type and any size with saddle / fasteners/ insulators and fixing screws etc complete all as specified and directed |
| 164 | Taking down and refixing of air termination single pointed rod of any type and any size with nut bolts or by welding as required etc complete all as specified and directed |
| 165 | S & Ftest point terminal block made of gun metal or phorphous bronze of size 75mm x 75mm x 25mm drilled and screwed incl 3 Nos x 8mm dia 25 mm long hexagonal head screws complete all as shown on drgcomplete all as specified and directed |
| 166 | Supply and fixing as in replacement Air termination, single pointed copper rod 12mm dia and 300 mm long complete all as specified and directed. |
| 167 | Supply and fixing as in replacement Air termination, single pointed aluminium rod 12mm dia and 300 mm long complete all as specified and directed. |
| 168 | Taking out old existing earthing and Material and labour for new earthing complete with copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with copper strip of size 20mm x 3mmby means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 40mm (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 150mm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) type B-1 cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed. |
| 169 | Taking out old existing earthing and Material and labour for new earthing complete with galvanised earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with GI strip of size 32mm x 6mmby means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 40mm (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 150mm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) type B-1 cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed. |
| 170 | Taking out old existing earthing and Material and labour for new earthing complete with galvanised earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with GI strip of size 25mm x 4mmby means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 40mm (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 150mm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) type B-1 cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed. |
| 171 | Taking out old existing earthing and M & Lfor new earthing with galvanised steel earth plate electrode 600mmX600mmX6mm thick burried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below ground level connected to 4mm dia GI wire protected by 20 mm bore light grade galvanised iron pipe and other end connected to test point as directed including funnel with wire mesh and watering pipe 20 mm bore medium grade galvanised iron pipe with charcoal and common salt in alternaterlayers of 15 cm thickness all around the GI plate electrode with concrete pit in PCC 1:3:6 type C-1 with cast iron frame including cast iron cover 10mm thick hinged to CI frame and 6mm MS rod for handle, necessary excavation and earth wok in hard/dense soil and disposal of spoil to a distance n exc 50 m and necessary testing complete all as shown in electrical plate No 3 of SSR part-I complete all as specified and directed. |
| 172 | Material & labour GI tube light grade 40 mm bore with all fittings for protection of cable, laid under road for passing cable, on wall complete all as specified and directed. |
| 173 | M & L plain cement concrete (1:2:4) type B-1 using 20 mm graded crushed stone aggregate as used for foundation of errection of pole, filling in repair of road cuttings etc complete all as specified and directed. |
| 174 | Excavation in trenches not exceeding 1.50 m wide and n.exc 1.5 m in depth for foundation of poles, cable etc, not exc 10 sqm on plan and getting out in soft/loose soil including taking out brick protection etc complete all as specified and directed. |
| 175 | Returning, filling in, including spreading, leveling, wateringand well ramming in layers not exc 25cm thick complete all as specified and directed. |
| 176 | Removing excavated materials (soils) not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed. |
| 177 | M & L for sand cushioning by spreading in trenches crushed sand by gently by punning down manually as in cable protection all as specified and as directed by Engineer -in-charge.Note : Thickness of sand cushioning after punning down will be measured. |
| 178 | M&L for bricks sub-class \"B\" laid in trenches in flat style (width portion in horizontal shape) for cable protection complete all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail