| 1 | Excavation in trenches not exc 1.5M wide and not exc 1.5M in depth and getting out in soft loose soil for cable work or from above cable duct all as specified and directed. |
| 2 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25cm thick all as specified and directed. |
| 3 | Removing of excavated material n.exc 50m and depositing where directed at a level not exc 1.5M above the starting point all as specified and directed. |
| 4 | Supply and fixing HDPE double wall pipe corugated pipe of size 50mm dia for cable protection laid in trenches in lieu of sand/brick protection all as specified and directed. |
| 5 | Supply and fixing HDPE double wall pipe corugated pipe of size 80mm dia for cable protection laid in trenches in lieu of sand/brick protection all as specified and directed. |
| 6 | Supply and fixing HDPE double wall pipe corugated pipe of size 100mm dia for cable protection laid in trenches in lieu of sand/brick protection all as specified and directed. |
| 7 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth and getting out in hard disintegrated rock (considered for road cutting & near hill side root) complete all as specified and directed. |
| 8 | Supply, laying in cable trey/wall & connection PVC XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade cross section area 10 Sqmm 4 core incl dismantling taking down unsv one from wall, cable tray, trench complete all as specified and directed. |
| 9 | All as per item No. 8.00 above,but of size 16 sqmm, 4 core. |
| 10 | All as per item No. 8.00 above, but of size 25 sqmm, 4 core. |
| 11 | All as per item No. 8.00 above, but of size 35 sqmm, 4 core. |
| 12 | All as per item No. 8.00 above, but of size 50 sqmm, 3.5 core. |
| 13 | All as per item No. 8.00 above,but of size 70 sqmm, 3.5 core. |
| 14 | All as per item No. 8.00 above,but of size 120 sqmm, 3.5 core. |
| 15 | All as per item No. 8.00 above,but of size 240 sqmm, 3.5 core. |
| 16 | All as per item No. 8.00 above,but of size 300 sqmm, 3.5 core. |
| 17 | All as per item No. 8.00 above,but of size 400 sqmm, 3.5 core. |
| 18 | M & L for Earthing complete with galvanised steel earth plate electrode 60 x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised iron strip 32 x 6 mm as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel as shown in electrical Plate No. 2, connected to the earthing test point, concrete pit in PCC 1:3:6 type C-2 with RCC precast pit cover slab 80mm thick with handle for lifting made out of 8mm dia MS rod, Funnel with watering pipe, wiremesh, charcoal and salt in alternate 150mm thick layers aroundearth plate including necessary returning filling in & removal all as specified or indicated in SSR Part-I, including testing to achieve earth resistance value as per IS specification on completion after dismentling taking out unserviceable one complete all as specified and directed. |
| 19 | S&F Earth continuity conductor galvanised iron strip of size 25x4 mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe/duct or fixed to poles or any other indicated situation for loop earthing etc. using required nut, bolt & washers as per site requirementincluding taking down unserviceable one from conduit/pipe/duct complete all as specified and directed. |
| 20 | M&L for PCC 1:3:6 , type-C 2, using 40mm graded agregrate for repair to path/drain/road against damege due to excuvation/laying of cable complete all as specified and directed. |