Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 28-02-2026 | CORRIGEDDUM | BOQ | 09-03-2026 |
| Sl. No. | Item Description |
| 1 | Surface excavation30cm deep and getting out in soft/loose soil complete all as specified and directed. |
| 2 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth for foundation getting out soft loose soil complete all as specified and directed by Engr-in-Charge. |
| 3 | Returning filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm of soft loose soil. |
| 4 | Removing excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point, complete all as specified and directed. |
| 5 | Material & Labour for plain cement concrete (1:4:8), type D-2, (using 40mm gradedcrushed stoneaggregates)in foundations, filling, mass concrete etccomplete all as specified and directed. |
| 6 | M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directd by engr-in-Charge |
| 7 | M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:4 complete all as specified and directd by engr-in-Charge |
| 8 | M&L Brickwork with subclass ‘B’ bricks, straight for curved on plan to any radius in half brick thick walls built in CM 1:4. |
| 9 | M & L for Hardcore of gauge not exceeding 63 mm, og broken stone or boulders deposited,spread and levelled in layers not exceeding 15 cm thick, watered and rolled/rammed to a true surfacescomplete all as specified and directed |
| 10 | M&L for providing reinforced cement concrete M-25 (Design Mix) using 20mm nominal size graded crushed stone aggregate as in beams, cantilevers, bressumers,lintels over 1.5m span etc, complete all as specified and directed. |
| 11 | M&L for providing reinforced cement concrete M-25 (Design Mix) using 20mm nominal size graded crushed stone aggregate as in chajjas etccomlpete all as specified and directed. |
| 12 | M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels. Cantilevers, shelves including supports, overhangs, etc also splays between floor and beam etc for rough finished flat surfaces of cocrete complete all as specified and as directed. |
| 13 | M&L for formwork to chullah hoods, chajjas, troughs and similar items including edges for rough finished flat surfaces of concrete, complete complete all as specified and as directed. |
| 14 | M&L Antitermite treatmanet treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface, complete all as specified and as directed. |
| 15 | M&L Antitermite treatmanet Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall, complete all as specified and as directed. |
| 16 | Dismantling of plain or corrugated steel sheeting any guage, thickness including Nanital or similar pattern roof coverings etc,complete all as specified and as directed. |
| 17 | Taking down roof trusses, coupled rafters or trussed beams of clear span upto 4 mtrs, complete all as specified and as directed. |
| 18 | Demolition of reed, lathing, single or double, including battens and plaster or chicken wire lathing,complete all as specified and as directed. |
| 19 | Dismantling timber scantlings 40 sq. cm and over in section, in any position , complete all as specified and as directed. |
| 20 | Taking down chowkat or frame with shutters (without taking off shutters from the frame) not exceeding 1.5sqm each and making good to disturbed surfaces and removing from site of work complete all as specified and as directed. |
| 21 | Taking down chowkat or frame with shutters (without taking off shutters from the frame) exceeding 1.5sqm but not exceeding 4.0sqm each and making good to disturbed surfaces and removing unserviceable materials from site of work,complete all as specified and directed. |
| 22 | Demolition of unreinforced cement concrete in ground floors and pavings n. exc 15 cm thickness (below or above ground level),complete all as specified and directed. |
| 23 | M&L TMTbars 10mm dia and over, cut to length, bent to shaperequired, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia orsecuring with clips ,complete all as specified and directed. |
| 24 | All as per Item No.023above, but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, complete all as specified and directed. |
| 25 | M&L for rendering 15mm thick in CM 1:4 and finished fair and even,complete all as specified and directed. |
| 26 | M&L for rendering 10.mm thick plaster in cm 1:6 on fair faces of brick work or concrete surfacesincluding finishing top even and smooth without using extra cement,complete all as specified & directed. |
| 27 | M&L Prepration of newly plastered surface of wall and applying one coat of white wash,etc complete all as specified & directed. |
| 28 | M&Lfor Prepration of newly plastered surface of wall and applying two coat of cement base paint etc complete all as specified & directed. |
| 29 | M&L for preparation of new plastered surfaces of wall and applying three coat of white wash, etc complete all as specified & directed. |
| 30 | M &L for Pressed steel frames (105 x 60) for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed complete all as directed. |
| 31 | M&L for plain cement concrete (1:3:6), type C-1, (using 20mm graded crushed stone aggregates) as in bed block, blocks for holdfasts,filling in pressed steel door frames , benching slightly rounded or chamfered angles & throating etc including necessary use & waste of form work , complete all as specified and directed. |
| 32 | S&F Steel windows with side hung shutters including box type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded etc complete all as specified and directed. |
| 33 | S&F 30 mm thick, Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides & fixed to chowkats complete all as specified & directed. |
| 34 | S&F4mm thick sheet glass, ordinary quality and glazing with oil putty in squares n exc 0.5sq. m in each panecomplete all as specified and as directed. |
| 35 | S&F framed work such as griils, grating, angle iron door frames etc., with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, barred iron doors, laders, framed balusters, walk ways, railings frame work of water tanks and similar work conforming to Fe-290. Gde E-165 etc complete all as specified & as directed. |
| 36 | S & F mild Steel work in hollow square/rectangular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S. 4923 -1997 (Reaffirmed 2009)grade Yst.-310 complete all as specified and directed. |
| 37 | S & F Mild steelbolts with hexagonal or square heads at one end and screwed the other or screwed both ends each screwedend to be fitted with washers and one hexagonal or square nut exc 30cm long and diameter exc 12 n.exc 20 complete all as specified and directed |
| 38 | M&L for PCC 40 mm thick (1:2:4) type B0 (using 12.5mm graded crushed stone aggregate) as infloors, finished even and smooth ,using extra cement etccomplete all as specified and directed |
| 39 | M&L for glass dividing strips 3 mm thk 38 mm wide and instead in position conferem to designcomplete all as specified and directed. |
| 40 | M&L for PCC 100 mm thick (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as inHardstanding/ footpath/ shaft paving etc, complete all as specified and directed. |
| 41 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars etc. but excluding ashlar facings, dressed stone work & precast concrete articles complete all as specified & directed. |
| 42 | S & F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ S & F Ceosetory windows and other Frames/Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives(maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof,water/ moisture proof and fire retardant and fixed in position with and including MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. |
| 43 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plainflushdoor shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisturproof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with and including stainless steel concealed hinges of required size with necessary S.S screws, all as per direction of Engineer- In- Charge. |
| 44 | S & F for aluminum powder coated (powder coated of required colour) three track (2 Nos Glazed shutter & 1 Nos Gauzed shutter) sliding windows frame top & sides of size 92 x 31.75 x 1.50mm (section No 20831) bottom of size 92 x 31.75 x 1.50mm (Section of 20832) and shutter top & bottom of size 40 x 18 x 1.55 (section 20738) and lock side shutter frame of size 40 x 15 x 1.45mm (Section 20737) with rubber gasket, beading and locking arrangement including making good to the disturbed portion complete including stainless steel wire mesh 0.36mm nominal dia with 1.40mm average aperture and fixed with stainless steel wire staples and fixing 5mm thick glass with necessary rubber beading gasket etc complete all as specified and directed. |
| 45 | M & L for waterproof cement based putty @ 1 Kg (undiluted) per sq mtr of average thickness 1mm over the plastered / old painted wall after scrapping to prepare the surface even and smooth complete and sanding of the putty surface with mechanical wall sander (having mechanical vacuum mechanicsm) having RPM not less than 1500, sanding pad of 240 grit or above to make the surface free from dust etc by skilled labour as per following steps : -Step 1 : Mix the putty powder by adding water as per manufacturer instructions and mix it with putty mixer with the mixing capacity of min 2.5Kg putty per minute.Step 2 : Apply the first coat the prepared mixer with the help of fully automatic airless spray machine of putty application having flow speed of max 6 ltrs per minutes with a max pressure 3300 PSIStep 3 : Allow 6-8 hrs time to dry the putty surfaceNote : (a) The work pertaining to periodical services and water proofing primer shall be executed from authorized applicator through manufacturer of which the materials i.e. Paint, Distemper, Putty etc is proposed to be used by the contractor and approved by GE.(b) Cost of Scafolding upto 10 mtr height of building is included in this item.(c) The contractor shall upload along with the documents under cover I , Memorandum of understanding (MoU) with only one manufacturer mentioned in the contract, failing which the bid shall be liable to be rejected.(d) Masking of waindow/doors during spray painting using polythine film will be included (e) Cleaning and clearing site of paint, mats etc included.(f) 05 years guarantee of painting work will be admissible after date of completion and 15% amount will be reserve against painting work after date of completion for the 05 years and same will be realised to contractor after satisfactory completion of 05 years. |
| 46 | M & L for one coat of acrylic water based exterior grade primer @ 0.9 ltr (undiluted/10 sqmtrs diluted with water 1:1 ratio to be applied with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI Allow 6-8 hrs to dry the surface for painting of subsequent coats complete all as specified and directed.Note :(a) The work pertaining to periodical services and water proofing shall be executed from authorized applicator through manufacturer of which the materials i.e. Paint, Distemper, Putty etc is proposed to be used by the contractor and approved by GE.(b) Cost of Scafolding upto 10 mtr height of building is included in this item. |
| 47 | M & L for two coat water based premium acrylic smooth exterior emulsion of approved colour with silicon additive and color stay Techonology, Excellent Dirt Pick up resistance with low VOC less than 50 gram/litre as per the LEEDS specifieecations, Anti Algal properties in two coats @ 1.79 ltr (Undiluted)/10 Sqm with water as per manufacturer instructions applied over priming coat with fully automatic airless spray machine of paint application with a flow spreed of min 1 ltr per minute having a pressure of 3300 PSI Allow 6-8 hrs to dry the surface in both coatsof paint complete all as specified and directed.Note :(a) The work pertaining to periodical services and water proofing shall be executed from authorized applicator through manufacturer of which the materials i.e. Paint, Distemper, Putty etc is proposed to be used by the contractor and approved by GE.(b) Cost of Scafolding upto 10 mtr height of building is included in this item. |
| 48 | S&F 150 mm size, aluminium anodised , barrel tower bolts of extruded section & fixed completeall as specified and as directed. |
| 49 | S&F 250mm length of bolt, aluminium alloy, anodized,sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified & as directed. |
| 50 | S&F 150mm size aluminium handles, cast type, anodized and fixed complete all as specified & as directed. |
| 51 | M&L for applying two coats of oil bound distemper using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surface scomplete all as specified and directed.Note : (a) Sanding of surface to be done by mechanical sander with 1500-2700 rpm, with internal dust extraction system for clean environment certified by paint manufacturer. Proper mashking to carried before primer and paint application.(b) The work pertaining to periodical services and water proofing shall be executed from authorized applicator through manufacturer of which the materials i.e. Paint, Distemper, Putty etc is proposed to be used by the contractor and approved by GE. |
| 52 | M&LforPCC 1:3:6 type C-2 (using 40mm graded crushedaggregate ) as in foundation, filling, sub base etccomplete all as specified and as directed. |
| 53 | M&Lfor 100mmPCC 1:3:6 type C-2 using(using 40mm graded crushedaggregate ) as in Hardstaing/ footpath/ shaft pavingsetccomplete all as specified and as directed. |
| 54 | S&FMild Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S. 4923 -1997 (Reaffirmed 2009)grade Yst.-310 complete all as specified and directed. |
| 55 | M&L for80 mm thick Machine pressed colouredprecast cement concrete interlocking paver block any shape and sizsas directed, confirming to IS 15658-2006, M-35Grade as in floor etc. set and jointed with graycement andpigmentcomplete all as specified and directed. |
| 56 | M & L for Chequred cement corcrete tile 20cm x 20xm x 25 mm thick with grey cement and pigments, set, jointed and pointed in grey cement slurry and pigments in floor laid over and including 15mm thick screed bed or bedding layer in CM(1:6) |
| 57 | M&L for Providing, cement concrete 1:2:4 type B-1 (using 20mm graded crushedaggregate) as in roof kerbs or mud stops, rounded or chamfered on edges, etc complete all as specified and directed. |
| 58 | S&F rolled mild steel Plates (plain or chequred) channels, square cut or notched (ordinary and counter sunk) forming holes, with out any attachmentconforming to Fe:410-W(Gde-E-250) quality-\"A\"complete all as specified and directed. |
| 59 | S&F, Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheets, 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof overing/ cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 60 | S&F, Pre-painted galvalume aluminum zinc coating GI based Plain steel sheets, 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, ridge, etc. fixed with self tapping screws complete all as specified & directed. |
| 61 | Providing and fixing inter locking metal grid (snap grid for false ceiling) of size 605mm x 605mm in true horizonatal level, hot dipped galvanised steel sections consisting of main “T” runner with suitably spaced joints to get required length and size 24mm x 38mm made from 0.30mm thick (Min) sheet spaced at 1200mm centre to centre and cross “T” of size 24mm x 28mm made of 0.30mm thick (Min) sheet, 1200mm long spaced between main “T” at 600mm centre to centre to form a grid of 1200mm x 600mm and secondary cross “T” of length 600mm and size 24mm x 28mm made of 0.30mm thick (Min) sheet to be interlocked at middle of the 1200mm x 600mm panel to form grids of 600mm x 600mm and wall angle of size 24mm x 24mm x 0.4mm. Main “T” runner to be suspended from ceiling using 4mm GI rods, 1200mm x 600mm centre to centre all complete for all heights as per specifications and as directed by Engineer – in - Charge. |
| 62 | M&L for 4 mm thick high pressure, oceanic pre-primed, self embossed, non asbestos fibre cement decorative board, water, termite and fire resistant for insulation ad acoustic purpose to be placed in grid system duly suspended with 2 to 3mm dia GI wire hangers fixed with steel dash through fasteners from purlins with butterfly clips, hold down clips with provision of high fixtures, air conditioning, diffuser and ducts, sprinkler, smoke detector etc, complete all as per manufacturer instructions |
| 63 | S&F Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, etc complete all as directed by Eng-in-charge. |
| 64 | S &F 5.5 mm thick Sheet glass, selected quality and fixed in aluminium frame workin squaresexc 0.5 sq. m in each pane |
| 65 | M&L for machine cut Kota stone slab flooring 18-20 mm thickover cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and granite finish polishingcomplete ovr 20 mm thk cement screed bed in CM 1:4, etc complete all as directed by Eng-in-charge. |
| 66 | M&L for machine cut kota stone slab flooring 15-18mm thick over 10 mm thk cement screed of cement mortar 1:4 base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and granite finish polishing as in rise rs of step skirtings dedo etc complete all as directed by Eng-in-charge.. Note :(kota ston to be fixed in stairecase thread shall be of single piece) |
| 67 | M&L for coloured non skid joint free ceramic tiles of 7mm to 8mm thick as in skirting and dado, etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick renderingin cement mortar 1:4 for vertical surfaces such as skirting etc complete all as specified & directed. |
| 68 | M&L for coloured non skid joint free ceramic tiles of 7mm to 8mm thick (squire / rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 sqm in floors, etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in cement mortar 1:6 for laying floor finishes etccomplete all as specified and directed. |
| 69 | M&L for 75 mm thick Cement concrete type C-2, 1:3:6 (using 40 mm graded crushedstone aggregates) as in plinth protection etc, finishing cement concrete surface even and smooth with out using extra cement including making joints with hot bitumastic mix in proportion of bitumen and sand 1:2, etc complete as specified & directed. |
| 70 | M&L Preparation of newsteeland iron surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paintover a coat of red oxide primer complete all as specified & as directed. |
| 71 | M&L preparing new wood & wood based surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified & directed. |
| 72 | Taking down aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as directed. |
| 73 | Material and labour for concealed point wiring using approved colour coding as per IS, with multi stranded copper conductor 1.5 sqmm (Nominal area), single core, FRLH, PVC insulated and unsheathed stranded cable drawn through and including non metallic, heavy duty PVC concealed conduit not less than 20mm dia and its fittings including all tees, bell mouth pieces and fixing accessories such as couplers, saddlers, pipe hooks etc, PVC junction boxes ISI marked with GI flush boxes / sunken boxes made out of 1.2mm thick of any module from 2 to 18module confirming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly including modular cover plates with frame i.e. inner and outer plate extended upto 25 mm over sunken box for housing the modular switches, socket outlets, fan regulators etc with brass screws and brass washers and making good the disturbedsurfaces as per existing for one light / fan / bell point contorlled by one switch including 1.5 sqmm single core PVC insulated and unsheathed FRLSH copper cable, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor upto common earth and connecting to common earth dollywith suitable size of lugs for one light point/ fan point/bell point controlled by one switch complete all as specified and as directed.NOTES : - (i) The quoted rates shall be deemed to be inclusive for cutting chases by chase cutter in wall/ pillars/ columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. The portion of point wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using necessary accessories/fittings. (ii) Point wiring & earth wire shall be connected to each & every flush/sunken box. (iii) All screws, fasteners, bolts, nuts & washer shall be cadmium plated & the cost of which is deemed to be included in the quoted unit rates. |
| 74 | One Light point/ Fan point/ Exhaust fan point controlled by one, one way switch |
| 75 | One Socket outlet 3 Pin, 5 Amp on same board complete all as specified and directed |
| 76 | All as per item No 76 above but one Socket Outlet Point, 5 Amp on independent board with 2.5 Sqmm cable all as specified and as directed |
| 77 | All as per item No 76 above but one Socket Outlet Point, 15 Amp on independent board with 2.5 Sqmm cable all as specified and as directed |
| 78 | S&F modular switch one way 6 amps 1 module complete all as specified and as directed. |
| 79 | S&F in repair modular switch one way 6 amps 1 module complete all as specified and as directed. |
| 80 | S&F modular switch one way 16 amps 1 module complete all as specified and as directed. |
| 81 | S&F in repairmodular switch one way 16 amps 1 module complete all as specified and as directed. |
| 82 | S&F modular socket 6 amps 5 Pin 2 module complete all as specified and as directed. |
| 83 | S&F in repairmodular socket outlet 6Amp 2 module intel multi socket for all pins 230 V AC complete all as specified and directed. |
| 84 | S&F modular socket 6/16 amps 6 Pin 2 module complete all as specified and as directed. |
| 85 | S&F modular socket outlet 16 Amp 2 module and 6/16 Amp heavy duty 230 V AC complete all as specified and directed. |
| 86 | S&F modular fan regulator step type 2 module complete all as specified and as directed. |
| 87 | S&F in repairmodular ceiling fan regulator, electronic step type, 5 speed AC 230 volts, 2 module complete all as specified and directed. |
| 88 | M&L for ceiling rose, surface Bakelite of three terminals PVC/Polycarbonate,isolated body (ISI Marked) |
| 89 | S&F ceiling rose, three terminal, PVC/polycarbonate, isolated body, ISI markedcomplete all as specified and as directed. |
| 90 | S&F of LED light fitting 1x20W, 220V, AC, batten type with driver , holder including 20W LED tube light for connecting up with three core flexiable copper conductor cable of suitablae size from celing rose to connectorof any description and in any position complete all as specified and directed. |
| 91 | S&F LED Bulk head fitting 10 watt in engineering plastic housing with clear prismatic diffuser complete with all accessories internally pre-wired and fixed to walls/ceiling on PVC Box with screw including connecting up with twin coreflexible copper conductor cable with suitable size complete all as specified and directed. |
| 92 | S&F of LED security light luminaire 30/35 watt , pressure die cast aluminum housing, toughened heat resistant glass, IP66 protection, better optics for uniform distribution with multiplte LEDshaving optical grade polycarbonate lens with all accessories internally pre wired and including connecting up with two core 1.5 sq mmcopper conductor cable from connector to ceiling rose to connection of light complete all as specified and directed. |
| 93 | S&F LED Tube lights fitting 1 x 18/20 Watt, 4 feet ,220V AC decorative box type with driver, holder including fitting fixed on wall/ceiling and connecting up complete withflexible cable white of suitable size and making necessary connection complete all as specified and directed. |
| 94 | Fixing only serviceable LED Tube lights fitting 1 x 18/20 Watt, 4 feet ,220V AC obtained from item no 1.00 above. |
| 95 | S&F LED building security light fitting 1 x 35 Watt new generation energy saving and environmental friendly long life LED street light made up of pressure diecast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP65 protectionincludingmounting bracket of suitable size and connection complete all as specified and directed. |
| 96 | S&F Ceiling fans 1200 mm sweep, AC 230 V complete with blades, down rods andconnected accessories, Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with (BLDC) brushless direct current motor and connection complete all as specified and directed. |
| 97 | Taking down carefully old unserviceable ceiling fans / Exhaust fans complete, removing its blade and deposit to the MES Store yard by the contactor. |
| 98 | Hanging only ceiling fan any make/ sweep and connecting up with existing electric circuit complete received from MES Store Yard all as specified and directed. |
| 99 | Supply, installation, testingofSPN distibution board 8 way,double door , IP 43, as per IS 8623including 100 Amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing, reversible doors, PAN assembly for easy installation and also incoming and outgoing connections with suitable size of lugs/thimbles/glandscomplete all as specified and directed. |
| 100 | S&F MCB 25 to 32 Amp SP&N, 240 volts 10 KA \"C\" series with all incoming/outgoing connections with proper size lugs complete all as specified and directed. |
| 101 | S&F MCB 6 to 32 Amp SP, 240 voltss 10 KA \"C\" series with all incoming/outgoing connection with proper size lugs complete all as specified and directed. |
| 102 | S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with one number single pole MCB 20 Amps , 240 Voltscomplete all as specified and as directed. |
| 103 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core, complete all as specified and as directed. |
| 104 | M&L for brick protection over cables inside the trench by using common burnt clay building bricks,sub-class\"B\" laid dry and flat and width wise along the axis of the trench complete all as specified and as directed by Engineer-in-Charge. |
| 105 | S&F single pole and neutral DB wall mounting type, 240 Volts,4 Way with 200 Amps rated bus bar, double door suitable for fixing MCB\"s including connecting etc and taking down U/S DB ,main switch complete. |
| 106 | S&F MCB single pole and neutral (SP&N) 32 Amp 240 volts 10 KA \"C\" series with all incoming/outgoing connections with proper size lugs including taking down old unserviceable, complete all as specified and directed. |
| 107 | S&F MCB single pole (SP) 6 to 32 Amp 240 Volts 10 KA \"C\" series with all incoming/outgoing connection with proper size lugs complete all as specified and directed. |
| 108 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core, complete including taking down old u/S service wire. |
| 109 | M&L for sand cushioning in cable trenches over & under the cables, with river washed coarse sand, as per standard practice with proper compaction/ under floors or in foundations including watering and consolidationcompleteall as specified anddirected by Engr-in-Charge. (Punned thickness shall be considered for payment). |
| 110 | M&L for light grade galvanized pipe ISI marked with all fitting ISI marked, laid in trenches, under road or fixing on wall/pole/ crossing nallahetc of bore40 mm complete all as specified and as directed . |
| 111 | M&L for providing sub main wiring with two single core 4.00 Sqmm (nominal area) PVC Insulated FRLSH unsheathed multi stranded copper conductor cable 1100 volts grade drawing through including concealed PVC Conduit of suitable sizeincluding 4.00 Sqmm PVC insulated unsheathed multi stranded FRLSH single core copper conductor cable for earth wirecomplete all as specified and directed. Note : (i) Three runs of single core 4.00 Sqmm multi stranded copper cableand one run of conduit shall be measured as one run length (ii)cutting chasing and making good to the disturbed srface shall be included in quoted rates. |
| 112 | Material and labour for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to galvanized iron earth lead wire 4mm dia, (main earthing lead ) by means of galvanized bolts, nuts and washers all as shown in electrical plate No. 5 of MES Schedule Part-I (1991) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm dia GI pipe light grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia light grade for watering pipe with funnel & wire meshincluding necessary earth work and PCC (1:3 6) type C-1 for earth pit and 40 mm thick pre-cast RCC cover in 1 : 2 : 4 type B1 with 3 Nos 8 mm dia TMT bars both ways completeall as specified & directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail