| 1 | Demolition of cement concrete including floor tiles or stone in any description and any position etc removal from site up to 500 m complete all as specified and directed |
| 2 | M&L for 75 mm thick PCC1:4:8 type D-2 using 40mm graded as in sub base of floor (40 mm graded stone aggregate), finishing even and smooth without using extra cement to received tiles including necessary form work etc completeall as specified and directed. |
| 3 | S & F for precast cement concrete type B-1 (1:2:4) (20mm graded stone aggregate ) as in kerb and edging to road and footh path, etc including chamfered, weathering, throating etc and setting in CM (1:4) complete all as specified and as directed. |
| 4 | M&L high strength outdoor endura or equivalent full body vitrified tiles 10-12mm thick (Square or rectangular) area of each tile exc 0.08 Sqm but n exc 0.18 Sqm in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match the tiles laid over and includig 15 mm thick screed bed or bedding layer of cement mortar (1:4). including roughning of surface and cement mortar bedding all as specified and directed. |
| 5 | Excavation in trenches n exc 1.5m wide and n exc 1.5m in depth for foundation, cesspits, etc and getting out in hard/dense soilcomplete all as specified and directed. |
| 6 | M&L for plain cement concrete 1:4:8 type D2 using 40mm graded crushed stone aggregate asin foundations, filing and mass concrete complete all as specified and directed. |
| 7 | M&L for brick work with sub class \"B\" bricks straight or curved on plan exc. 6m mean radius built in cement mortor 1:6., etc complete all as specified and directed. |
| 8 | Returing, filling in trenches, incl spreading, levelling, watering and well ramming in layers not exc 25 Cm in hard/dense soil complete all as specified and directed. |
| 9 | Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5, above the starting point complete all as specified and directed. |
| 10 | M&L for plain cement concretetype B1 1:2:4 (20mm graded stone aggregate) as on levelling course and other works as in roof kerb,coping,padding etc complete all as specified and directed. |
| 11 | Taking down cement plaster on brick or concrete surfaces, parapets including raking out joint, hacking for key, scrubbing down with water, at any description with necessary scaffolding etc complete all as specified andas directed. |
| 12 | M&L for rendering 10mm thick in CM 1:6 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed. |
| 13 | M&L for rendering 15mm thick in CM 1:4 on other than fair faces of brick or concrete surface with liquid water proofing compound @ 200 ml per bag finished even and smooth without using extra cement complete all as specified anddirected.(Note:- Liquid water proofing compound to be measured paid separately) |
| 14 | S&F powder coated aluminium window and ventilator shutters, sliding/openable/fixed (as per required at site)type without sash bar, alu section weighing 0.55 kg/m, including 3mm frosted glass , stainless steel wire mesh as per required at site, necessary locking arrangement, guide wheels, joining cleats, glazing clips rubber packing anodised alu snap beading screws etc complete allspecifiedand directed. |
| 15 | S&F 3mm thick figured glass pin head type in square n.exc 0.5 Sqm in each pane new ventilator / window shutter complete all as specified and directed. |
| 16 | S & F for stainless steel wire cloth of0.36mm dia wire and average width of aperture 1.40mm & fixed with tacks or screws, wire staples, etc complete all as specified and directed. |
| 17 | S&F steel rolling shutters,withoutball bearing as specifiedincluding top covers anchoring rod, hasp & staple and one shop coat of red oxide primer gear operated type with bevel gear box and crank handle and errected in position complete thickness of laths 1.25mm complete all as specified and directed. |
| 18 | S & F steel work in tubular trussles,purlins,rafters,tubler column, where connected common rafter and running rails fixed with angle cleat or other connection plates including special shaped washers etc.complete using ERW or inductionbutt welded tubes confirming to Fe 410W grade E 250 quality B, etc complete all as specified anddirected. |
| 19 | Providing & fixing false ceiling at all heights with semi perforated 12mm thick micro tegular edged GRG (glass fibre with reinforced gypsum) false ceiling tiles of size 595mm x 595mm of approved texture, having moisture content less than 2%, humidity resistance edged GRG thick square edged of 99%, NRC0.50 to 0.75 as per IS false ceiling GRG false ceiling 8225:1987, noncombustible as per BS tiles 4 76 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter locking metal T-grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main T runners of size 15mm x 32mm of length 3000mm,cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15mm x 32mm of length 600mm to form grid module of size 600mm x 600mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and shape level adjuster of size 85mm x 25mm x 2mm. galvanised iron perimeter wall angle of size 24mm x 24mm x 0.40mm of length 3000mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in Charge. |
| 20 | S & F 0.50mm thick (including coated thickness) Pre-colour, pre-profiled ( Galvalume ) sheets of required colour and design having tensile strength of 550 Mpa as in roof, wall cladding, north light curves, fixed with zinc coated self drilling fastener including EPDM washer complete laid with one corrugation side laps and min 150mm end lap laid to slope all as per manufacturer/ profile maker instruction complete all as specified anddirected. |
| 21 | S&F Framed work as in grill, grating, doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing in Fe 410-W (Gde-E-250) quality A complete |
| 22 | M & L for applying two coats of synthetic enamel paint on new or previously untreated steel surfaces exc 10cm width or girth over a coat of red oxide zinc chrome primer including preparation of surfaces complete all as specified anddirected. |
| 23 | S&F for 6mm thick fibre glass reinforced translucent plain/corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall, etc complete all as specified and as directed. |
| 24 | M & L for preparing new plastered surfaces of wall and applying two coats of distemper oil emulsion over a coat of alkali resistant cement primer and over a coat of 2 to 3mm thickwall care putty complete all as specified and directed. |
| 25 | Material and Labour forapply two coats of Anti fungal weather coat acrylic emulsion paint over a coat of primer on new surfaces including 2 -3 mm thick wall putty, complete all as specified and directed. |
| 26 | S&F 110mm bore PVC (SWR) pipes single socketed in any length with carefully prepare rubber ring joints (or solvent joint) fixed to walls / ceiling or laid in floor complete all as specified and directed |
| 27 | Demolition of cement concrete PQC of any description and in any position complete all as specified and directed. |
| 28 | Excavating over areas, n exc 1.5m deep and getting out in hard/dense soilcomplete all as specified and directed. |
| 29 | Removing excavated material exc 250m but n exc 500m and depositing where directed at a level n exc. 1.5m above the starting point as in soilcomplete all as specified and directed. |
| 30 | M&L for bonding chemical PMM Chemical for concrete joints/old concrete surface to new concretes in machine anchor bolt PCC etc complete all as specified and directed. |
| 31 | M&L for Ready Mix Concrete (RMC), M-30 Design Mix using 20mm graded aggregate for foundation including raft footings, complete all as specifiedand directed. |
| 32 | M&L sand filling/cushioning around the PCC foundation including watering and consolidationcomplete all as specified and as directed. |
| 33 | M&L for 100mm thick PCC 1:2:4 type B-2 using 40mm graded curshed stone aggregate as in floors/hard standing finished even and fair without using extra cementcomplete all as specified and directed. |
| 34 | Formwork to sides of concrete rough finish flat foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams: and similar works vertical or batter complete all as directed. |
| 35 | M&L TMT bars 10mm dia and over as in reinforcement cut to length, bent to shape required including crancking hooking ends and binding with mild steel wire annealed not less than 0.9mm dia or securing clips etccomplete all as specified and as directed. |
| 36 | M&L for Mild steel bars (TMT bars)5mm dia and over upto and including 10mm dia in strriups,spacers and binders complete all as specified and directed. |
| 37 | M&L for hole cutting in RCC foundation surface area not exc 0.30 sqm and depth not exceeding 0.60 mtrsfor machine anchoring bolt PCC etc complete a complete all as specified and directed. |
| 38 | M&L for core cutting in RCC foundation surface area not exc 30cm in depth and width and length required as per site for laying machinary pipe line, cable and drainage system etc complete a complete all as specified and directed. |
| 39 | Excavating in post holes (or similar holes) in soft/loose soil each not exceeding 0.5 Cum, getting out, reterning filling and ramming earth or broken rubber mixed with earth around in layers not exceeing 25 cm, watering and removing surplus soil to a distance not exc. 50m and making good surface complete all as specified anddirected. |
| 40 | M & L for applying two coats of synthetic enamel paint on new or previously untreated steel surfaces exc 10cm width or girth over a coat of red oxide zinc chrome primer including preparation of surfaces complete all as specified anddirected. |
| 41 | M&L for 60mm thick M-35 grade factory made rubber moulded coloured machine pressed precast conctete interlocking paver block in approved design and colour, confirming to IS 15658-2006 with gery cement and pigment as approved laid over and including 40mm thick sand cushion/Sand filling under floors complete all as specified and as directed. |
| 42 | M&L Reinforced cement concrete M-25 using 20 mm graded stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified anddirected |
| 43 | M&Lsand filling under floor or foundations including waterring and consolidaion complete all as specified and directed. |
| 44 | M & L for formwork to sides of pillars, posts, struts, piers, columns and stanchions finished fair complete all as specified anddirected |
| 45 | M&L Reinforced Cement Concrete M-25using 20 mm graded stone aggregate as in Columns, pillars, piers, posts and struts complete all as specified anddirected. |
| 46 | M & Lfor brick work with sub class \"B\"modular bricks, straight or curved on plan to any radius built in CM 1:4 in half brick thick walls complete all as specified anddirected. |
| 47 | M & L for formwork fair and finished surfaces to sides and soffits of floor or roof beam, beam hauchings, bands, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc complete all as specified anddirected |
| 48 | M&L Reinforced Cement Concrete M-25 using 20 mm graded stone aggr as in beams, bands, cantilvers, bressummers, linters, chajjas, etc over 1.5m span etc complete all as specified anddirected |
| 49 | M & L for formwork to fair finished surface for staircase with sloping or stepped soffits includings risers and stringers, soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 200mm thick (horizontal or sloping), etccomplete all as specified and directed. |
| 50 | M&L Reinforced Cement Concrete M-25using 20 mm graded stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, etc complete all as specified anddirected |
| 51 | M&Lfor moorum / red bajri filling in floors or pavings, laid in layers nexc 15cm thick, spread, levelled and rammed including waterring and consolidation complete all as specified anddirected. |
| 52 | M&L for hardcore of gauge n exc. 63 mm,of broken stone deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 53 | M & L 25mm thick cement concrete type B-0, 1:2:4 (using 12.5 mm graded aggregate) for levelling course in floors complete all as specified anddirected. |
| 54 | M&L plain cement concrete 1:3:6, type B1( using 20mm graded stone aggregate) 75mm thick as in plinth protection complete all as specified anddirected . |
| 55 | M&L for rendering 5mm thick in ceiling CM 1:3 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed. |
| 56 | Supply only integral water proofing compound complete all as specified and directed. |
| 57 | S & F MS framed work as in rails, braces and stair case etc complete, drilled for fixing of steel sheeting or other covering etc, to prepared for hanging or sliding with including either hooks and hinges also fastening grills, grating, hold fast of doors and windows chowkat etc, with ends of bars shouldered and or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walkways; railings; framework of water tanksand fixing and similar work confirming to fe 290 Gde E-165 complete all as specified and as directed. |
| 58 | S&F Factory made solid PVC door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube with wooden grain printed PVC sheet used inserted of plain colour PVC sheet & edges will be painted to match with printed sheet complete all as specified and directed. |
| 59 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails.MS frame shall be covered with heat moulded plain colourPVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail.Panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, complete all as specified and directed. |
| 60 | M & L for non skid joint free coloured ceramic floor tiles 7 to 8 mm thick (square/ rectangular) area of each tile exc 0.11 sqm but n exc 0.18 sqm,in floor etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the surface with 15mm thick screed bed or bedding layer in CM (1:6) complete all as specified anddirected. |
| 61 | M&L for glazed ceramic coloured wall tiles (textured and design as required) in vertical surface 450X300X7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick rendering in 1:4 CM complete all as specified anddirected. |
| 62 | M&L Glazed ceramic / Digital elevation coloured tiles in vertical surface 300x600x7mm/450x350x7mm thick set and jointed in neat cement slurry and pointed white or colour cement to match as specified as diracted. |
| 63 | M&L for 10mm thick rendering in CM (1:4) as in vertical surfaces of skirting dados repairs to steps complete all as specified and directed. |
| 64 | S&F vitreous china squatting pan `Orissa \" pattern of size 580x440mm white with integral foot rest (excluding flushing cistern and flush pipes) including connection to trap and to flush pipe etc and lime concrete bedding including \"P\" or \"S\" trap complete all as specified and directed. |
| 65 | S&F vitreous china wash and basin, white, flat back, size 550 mm x 400 mm incl fixed on new MS bracket, fixing of tap, waste coupling,fitting,waste pipe and union incl 15 mm bore pillar tap, fancy type, castcopper alloy with capstan heads, chromium plated, screwed down high pressure with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly nuts screwed for iron pipe complete all as specified anddirected. |
| 66 | S&F PVC flushing cistern 10 ltr capacity valve less syphonic action type low level with and including ball valve float & handle, waste pipe & brackets complete set all as specified and directed. |
| 67 | S&F PVC connections 15 mm size with PTMT of 450mm long complete all as specified anddirected. |
| 68 | S&F 75 mm dia of PVC floor trapplain with grating including jointing with solvent cement of outlet complete all as specified and directed. |
| 69 | S&F 15 mm bore CP bib tap of fancy type with long shunk with cast copper alloy of crutch or butterfly handle screwed down screwed for iron pipe or brass ferrule fixed complete all as specified and directed. |
| 70 | S&F 15 mm boreCP angle stop cock with wall flange complete all as specified and directed. |
| 71 | S&F 15mm bore brass, chromium plated, mixer for mixsing hot and cold water, screwed down for iron pipe and fixed. Complete all as specified and directed. |
| 72 | S&Fbrass Choromium plated shower rose with or without swivel joints 125mm size including fixing to steel pipe or union complete all as specified and directed. |
| 73 | S&F CP towel rail 600 mm long fixed with CP screws and wood cleats / rowel plug with wallcomplete all as specified and directed. |
| 74 | S&F 600x450mm belved edge mirror of selected quality glass mounted on 6 mm thick AC bldgs boards or commercial ply wood and fixed to wooden plugs with chromium plated brass screwed and cup wahses complete all as specified and directed. |
| 75 | Supply and fixing of soap-dish chromium plated all as specified and directed. |
| 76 | S&F rotational moulded polyethylene water storage tank of capacity 1000 ltr (Cylindrical/vertical with closed top) double layer construction, ISI marked complete all as specified and directed. |
| 77 | Supply, laying and fixing of 20mm outer dia of CPVC pipe SDR 11 and plain CPVC SDR 11 fittings on wall/ceiling or laying in floors complete including brass CPVC fittings (i.e elbow, Tee, MTA/MBTA,FTA/FBTA, Tank adaptor, Union, etc suitable for 15mm bore bath fittings). (Note- length of pipe with fittings to be measured for payment, no extra payment should be made for fittings). |
| 78 | Supply and laying of 32mm outer dia of CPVC pipe SDR 11 and plain CPVC SDR 11 fittings on wall/ceiling or laying in floors complete including brass CPVC fittings (i.e elbow, Tee, MTA/MBTA,FTA/FBTA, Tank adaptor, Union, etc). (Note- length of pipe with fittings to be measured for payment, no extra payment should be made for fittings). |
| 79 | S&F 20mm bore dia stop valve cast copper alloy screwed down , high pressure with crutch or butter fly handle ,screwed both ends for pipe or for unions and fixed complete all as specified and directed. |
| 80 | S&F ball/ float valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed 20mm bore minimum weight 210 gms complete all as specified and directed. |
| 81 | S&F 110mm bore PVC (SWR) pipes single socketed in any length with carefully prepare rubber ring joints (or solvent joint) fixed to walls / ceiling or laid in floor complete all as specified and directed |
| 82 | S&F 75mm bore PVC (SWR) pipes single socketed in any length with carefully prepare rubber ring joints (or solvent joint) fixed to walls / ceiling or laid in floor complete all as specified and directed |
| 83 | S&F 110mm size PVC (SWR) bends any radiuscomplete all as specified and directed |
| 84 | S&F 75mm size PVC (SWR) bends any radiuscomplete all as specified and directed |
| 85 | M & L for preparing new plastered surfaces of wall and applying two coats of distemper oil emulsion over a coat of alkali resistant cement primer and over a coat of 2 to 3mm thickwall care putty complete all as specified and directed. |
| 86 | Material and Labour forapply two coats of Anti fungal weather coat acrylic emulsion paint over a coat of primer on new surfaces including 2 -3 mm thick wall putty, complete all as specified and directed. |
| 87 | M & L for preparing new plastered surface on ceilingand applying three coat of white wash complete all as specified anddirected. |
| 88 | M&L for plain cement concretetype B1 1:2:4 (20mm graded stone aggregate) as on levelling course and other works as in roof kerb,coping,padding etc complete all as specified and directed. |
| 89 | M&L for laying of APP modified roof treatment over existing non-accessible RCC roof slab / chajjah / canopy / parapet of the membrane manufacturer with following specification etc complete all as specified and directed :-(a) removing and Cleaning existing damaged APP membrane from roof surface and clean all cement mortar and vegitation, plants with roots properly.(b) Applying oil bound bitumen primer @ 0.30 liter/Sqm manufacture by the same agency as that of APP with a density 0.87-0.89 Kg per litere at 25 degree centigrade on prepared surface.(c) Laying not less than 3mm thick APP modified water proofing membrane weighing not less than 3.00 Kg/Sqm reinforced with non woven polyster fiber weight not less than 160gsm/Sqm using butane torch application with 10cm side laps and 15cm end lap over hot bitumen 85/25 grade @ 1.2 Kg/Sqm overbituminousprimer before Laying of membrane. (d) APP membrane shall be laid using butane torch by Torch application with minimum 10cm side overlap and 15cm end lap.(e)Top of membrane shall be provide with solar reflective bituminous aluminum paint as prescribed by manufacture of membrane. |
| 90 | Removalof Mud from top roof slab, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof) complete all as specified and directed. |
| 91 | M&L for rendering 10mm thick in CM 1:4 on roof suraces with liquid water proofing compound @ 200 ml per bag finished even and smooth without using extra cement complete all as specified and directed. |
| 92 | M&L for dismentaling/demolition of RCC fins/parapets of any size incl. cutting down rusted reinforcement and makig good with CM 1:3 and provided drip course 25 mmx10 mm deep with CM 1:3 at edges of RCC slab/chajjas etc complete all as specified and directed. |
| 93 | S&F15mm bore pipe medium grade galvanised ironwater tube with all fittings laid in floors fixed to wall etc complete allas specified and as directed. |
| 94 | S&F 20mm bore pipe medium grade galvanised ironwater tube with all fittings laid in floors fixed to wall etc complete allas specified and as directed. |
| 95 | S&F of factory made 35mm flush shutter, solid core construction, with block board core and plywood face panels, commercial type on both side etc complete all as specified. |
| 96 | Taking down cement plaster on wall & ceiling of any description including racking out joints, hacking for key and scrubbing down with water etc complete all as specified and directed. |
| 97 | Taking down cement plaster on wall & ceiling of any description including racking out joints, hacking for key and scrubbing down with water etc complete all as specified and directed. |
| 98 | M&L 15mm thick ready mix plaster (Make Ultratech readiplast/ Birla Aerocon RMP/ ACC Suraksha RMP) on brick work on concrete surface of wall (external surfaces) finished even and smooth all as specified and directed by GE including taking down existing grit plaster of any thickness working heigh up to 32 mtrs with double scaffolding all as specified and directed by Engr-in-Charge. |
| 99 | M&L 15mm thick ready mix plaster (Make Ultratech readiplast/ Birla Aerocon RMP/ ACC Suraksha RMP) on brick work on concrete surface of wall (internal surfaces) finished even all as specified and directed by GE. |
| 100 | M&L 5mm thick ready mix plaster (Make Ultratech readiplast/ Birla Aerocon RMP/ ACC Suraksha RMP) on ceilling surfaces finished even and smooth all as specified and directed by GE. |
| 101 | M&L preparing newly plastered or unplastered surface of wall and applying three coats of white washing complete all as specified and directed. |
| 102 | M&L for preparation of old plastered surfaces of wall and applying two coats of white wash,competeall as specified and directed. |
| 103 | M&L preparing newly plastered or unplastered surface of ceiling and applying three coats of white washing complete all as specified and directed. |
| 104 | M&L for preparartion of old surfaces applying two coat of white washing on ceiling surfacecomplete all as specified and directed. |
| 105 | S&F Structural steel work for rolled sections as in main and cross beams,hips,jacks, rafters, purlins,runnings , rails and guides for sliding doors fixed with angles, cleats or other conneccting plates grade FE-410-W at working height 15m complete all as specified and directed. |
| 106 | M&L for PCC 1:5:10 ,type E-2 using 40mm graded crushed stone aggregate as in sub base and mass conc |
| 107 | Demolition of cement concrete (un-reinforced) in ground floors and pavings n. exc. 15cm thickness (below or above ground level) all as specified and directed. |
| 108 | S & F Framed work such as grills,gratings, oranamentals etc.. with ends of barsshouldered and/or riveted,or forged into spikes; framedguard bars; framedbalusters; walkways; railings; and similar work conforming to Fe.290.Gde-E-165 , complete all as specified and as directed. |
| 109 | M & L 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) includingpointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite with providing 15mm thick screed bed in cement mortar 1:4. |
| 110 | Supply, Fixing, Testing, commissioning OF Three phase Submersible fountainpumps (3 WHP)- 02 Nos (1W+1S), electric driven 415 V, flow rate 2500 LPM at 20 meter head along with starter & starter panel,Body :- CI (Cast Iron)Impeller CI including suitable size of sluice valve and NRVcomplete all as specified and directed by Engr-in-charge with consist following accessories :-(a)S&F of Stainless steel fountain nozzles(laminar/aeration type)-12 Nos(b) S&F of Central Jet Nozzle(High throw) -01 Nos(c)S&F of UPVC/CPVC circulation piping with all reqd fitting arrangement - 80 RM(d) S&F of Valves (Butterfly/ Ball /NRV)- 08 Nos(e) S&F of Pressure sand filter with media - 01 Set(f) Supply, Installation, Testing & Commissioning of Under water LED lights to highlight the jets suitable for 12V supply with LED’s wit SMPS Power Supply Controller for Lights (Panasonic / OPTO), 1M flexible cable with cable gland, all complete all as specified and directed. Model - OWC - 210 3W X 9 Led\"s 27 W Each Colour : RGB )- 16 Nos(g) Supply and fixing of SS lights stand/ Niche for LED light complete all as specified and directed-16 Nos(h) S&F of Electrical control panel with timer & protections -01 Set |