| 1 | SCHEDULE \"A\" PART-I : BOQ OF WORKS FOR B/R WORKS. |
| 2 | Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in any type of soil, complete all as specified and as directed. |
| 3 | Excavation in trenches, not exceeding 1.50mtr wide and not exceeding 1.50mtr in depth; for foundation, etc. or for laying cable, pipe lines, not exceeding 10 Sqm on plan and not exceeding 1.50 mtr in depth and getting out, in any type of soil, complete all as specified and as directed. |
| 4 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm, any type of soil, complete all as specified and as directed. |
| 5 | Removing excavated materials not exceeding 50mtrs and depositing where directed at a level not exceeding 1.50 metres above the starting point, complete all as specified and as directed. |
| 6 | Plain cement concrete M-7.50(1:4:8), type D-2 (using 40mm graded crushed stone aggregate), as mass concrete in foundation filling, complete all as specified and as directed. |
| 7 | Plain cement concrete, M-10 (1:3:6), type C-2 (using 40mm crushed stone aggregates) as in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases), complete all as specified and as directed. |
| 8 | Reinforced cement concrete, design mix M-30 (using 20mm crushed stone aggregates) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc and mass concrete, complete all as specified and as directed. |
| 9 | Reinforced cement concrete, design mix M-30 (using 20mm crushed stone aggregates) as in walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilastersandbuttresses, complete all as specified and as directed. |
| 10 | Formwork, use and waste type, as in faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter, to get fair finish surfaces of concrete, complete all as specified and as directed. |
| 11 | Formwork, use and waste type, as in fsides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, to get fair finish surfaces of concrete, complete all as specified and as directed. |
| 12 | Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed. |
| 13 | Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, including binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips, complete all as specified and directed. |
| 14 | Plain cement concrete M-15 (1:2:4), type B-0 (using 12.50 crushed stone aggregates), 40mm thick in damp proof course to horizontal or vertical surfaces including necessary formwork, complete all as specified and directed. |
| 15 | Safety lever locks mild steel with 4-levers for rolling shutters, complete all as specified and as directed. |
| 16 | Pre-cast cement concrete block masonry M-10(1:3:6), type C-1 (using 20mm graded crushed stone aggregate) with solid blocks, exceeding 10cm in width and incluing setting in cement mortar 1:6, complete all as specified and as directed. |
| 17 | Pre-cast cement concrete block masonry M-10(1:3:6), type C-1 (using 20mm graded crushed stone aggregate) with solid blocks, not exceeding 10cm in width and incluing setting in cement mortar 1:4, complete all as specified and as directed. |
| 18 | Rendering 15mm thick on fair faces of on brick work or concrete surfaces, in cement mortar 1:6, rendering is to be finished even and smooth (without using extra cement), complete all as specified and as directed. |
| 19 | Rendering 15mm thick on fair faces of on brick work or concrete surfaces, in cement mortar 1:4, rendering is to be finished even and smooth (without using extra cement), complete all as specified and as directed. |
| 20 | Rolled mild steel in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.confirming to Fe 410-W (Gde- E- 250) quality- A, complete all as specified and as directed. |
| 21 | Rolled mild steel as in plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment as in base plates/ gusset plate, cleats for securing purlins/ rafters and similar articles, conforming to Fe-290 (Gde E- 165), complete all as specified and as directed. |
| 22 | Rolled mild steel as in bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; handmade sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165, complete all as specified and as directed. |
| 23 | Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, diameter of neck in 16mm, length of bolt exceeding 22.50cm and not exceeding 30cm long, complete all as specified and as directed. |
| 24 | Pre-painted galvalume aluminium zinc coating galvanised iron based corrugated steel sheet 0.50mm of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specifed and directed. |
| 25 | Pre-painted galvalume aluminium zinc coating galvanised iron based plain steel sheet 0.50mm of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specifed and directed. |
| 26 | Preparation of new or previously untreated steel surfaces of any description, not otherwise described, over 10cm width or girth including and applying two coats of synthetic enamel paint over one coat of zinc chrome/ red oxide primer, complete all as specified and as directed. |
| 27 | Ball bearing for rolling shutters, complete all as specified and as directed. |
| 28 | Steel rolling shutters, thickness of laths in 1.0mm, without ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: gear operated type with bevel gear box and crank handle, complete all as specified and as directed. |
| 29 | Hardcore of broken stone or boulders, gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface, complete all as specified and as directed. |
| 30 | Plain cement concrete, M-7.50 (1:4:8), type D-2 (using 40mm crushed stone aggregates) 100mm thick, as in sub base of flooring, to receive floor finishes, complete all as specified and as directed. |
| 31 | Cement concrete work in pavement/ hard-standing of flexural strength 40 Kg/ per square centimetre in field using 400 Kg of cement per cubic metre, thickness of concrete 25Cm or less, complete all as specified and as directed. |
| 32 | Plain cement concrete M-10(1:3:6), type C-1 (using 20mm graded crushed stone aggregate), 75mm thick, as in plinth protection, finish even and smooth without using extra cement, complete all as specified and as directed. |
| 33 | Preparation of new plastered or unplastered surfaces of walls and applying two coats of distemper oil emulsion and including over one coat of chalk whiting to prepare the surface even and smooth, after preparing putty of 2.0mm thickness over newly plastered surface to prepare the surfaces before applying any paint or oil emulsion, complete all as specified and as directed. |
| 34 | Preparation of new plastered surfaces of walls and applying two coats of cement paint over one coat of priming plastered and other surfaces with alkali resistant priming paintlime wash, complete all as specified and as directed. |
| 35 | Forming Contraction (Dummy) joints 65mm deepx10mm wide, for thickness of concrete slab of 200mm, filled with sealing compound grade ‘A’, complete all as specified and as directed. |
| 36 | Forming 12 mm thick expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’, for thickness of concrete slab of 200mm, complete all as specified and as directed. |
| 37 | SCHEDULE \"A\" PART-II : BOQ OF WORKS FOR E/M WORKS. |
| 38 | Point wiring (in new concealed/ exposed conduits to surfaces as required at site) for one light/ fan/ bell point controlled by one switch with 1.50 Sqmm, PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, FRLS, 1100 Volts, using colour coding, drawn in and including any type of new conduit, of any size/ dia including all accessories concealed by chasing/ cutting or fixed with PVC plug and mild steel screws in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, with and including sunken type pressed steel/ welded mild steel terminal box 1.20mm thick coated and including FRLS PVC green insulated unsheathed 1.50 Sqmm copper earth continuity wire connected to earth dolly, complete all as specified and as directed.Note: Cost of modular boxes, modular cover plates and different types of modules including anti-corrosive screws shall be deemed included in quoted rate. |
| 39 | Description all as serial item No- 2.01 here-in-before but for one 3- pin, 5/ 6-Amps, socket outlet on same board. |
| 40 | Point wiring (in new concealed conduits to surfaces as required at site) for 3-pin, 15/ 16 Amps, switch socket combination on independent board with 4.0 Sqmm, PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, FRLS, 1100 Volts, using colour coding, drawn in and including any type of conduit, any size/ dia including all accessories concealed by chasing/ cutting or fixed with PVC plug and mild steel screws on the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, with and including sunken type pressed steel/ welded mild steel terminal box 1.20mm thick coated with anti corrosive paint with bakelite laminated sheet top cover 3.0mm thick and including FRLS PVC green insulated unsheathed 4.0 Sqmm copper earth continuity wire connected to earth dolly, complete all as specified and as directed.Note: Cost of modular boxes, modular cover plates and different types of modules including anti-corrosive screws shall be deemed included in quoted rate. |
| 41 | Modular switch piano, single pole, one way, 5/ 6 Amps, 1-module, complete all as specified and as directed. |
| 42 | Modular switch piano, single pole, one way, 15/ 16 Amps, 1-module, complete all as specified and as directed. |
| 43 | Modular socket outlet, 2-in-1, 3-pin, 5/ 6-Amps, 2-module, complete all as specified and as directed. |
| 44 | Modular Socket 6Amps/ 16Amps, 2/3-pin combined, 2-module, complete all as specified and as directed. |
| 45 | Modular white cover plate with frame, 3-module including metal flush box, complete all as specified and as directed |
| 46 | Modular white cover plate with frame, 8-module including metal flush box, complete all as specified and as directed |
| 47 | Ceiling rose, 3 phase/ PVC/ polycarbonate, isolated body, size 65mmx25mm dia, complete all as specified and as directed. |
| 48 | LED lights fitting wall surface mounted, 20 Watt, 220 Volt, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and as directed.Make: Havells cat part No-LUMILINEPLUSPROBS20WLED865SPCSSIND or equivalent in Philips/ Bajaj/ Crompton. |
| 49 | Sheet metal enclosures for Single Pole and Neutral distribution boxes with double door glazed for incorporating MCBs, IP-65, 8-way with 200 amps rated busbar, 240 volts, as per IS-8623, fixing in repairs, complete all as specified and as directed. |
| 50 | LED street light fitting 35 Watt 230 Volt, AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed.Make: Havells cat part No- Superb Street Light 30 W 6500 K IP65 or equivalent in Phillips/ Bajaj/ Crompton. |
| 51 | House service bracket, made with 2.50mtr long galvanised iron pipe 25mm dia medium grade, 120° bends including mild steel clamps of mild steel flat 50x6mm, hook, stay, nut, bolt and washer including painting with two coats of synthetic enamel paint over one coat of red oxide primer, complete all as specified and directed. |
| 52 | MCB, double pole and neutral, 32 Amps, 240 volts, 50 Hz, \"C\" curve including necessary incoming and out going electric connection with suitable size of copper lugs, fixing in repairs, complete all as specified and as directed. |
| 53 | MCB, single pole, 6 to 32 Amps, 240 Volts, 50 Hz, \"C\" curve including necessary incoming and out going electric connection with suitable size of copper lugs, fixing in repairs, complete all as specified and as directed. |
| 54 | Supplying and fixing in replacement of 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor of 10.0 Sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1.0metre apart including 4.0mm suspension wire, one twin core cable flat or circular, complete all as specified and directed. |
| 55 | Sub main wiring(in new concealed/ exposed conduits to surfaces as required at site) for circuits/ submain wiring along with earth wire with two run of 1.50 Sqmm of fire resistance, PVC insulated copper conductor, single core cable, multi-stranded, FRLS, ISI marked, 1100 Volts grade and one run of 1.50 Sqmm, FRLS, PVC insulated copper conductor, single core cable, multi stranded, ISI marked, 1100 Volts grade as earth wire connected to earth terminal, using colour coding, drawn in and including any type of new conduit of any size/ dia including all accessories concealed by chasing/ cutting or fixed with PVC plug and mild steel screws on the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, complete all as specified and as directed.Note: Cost of all three run of wire and one run of conduit of required size will be included in quoted rate. |
| 56 | Earthing complete with galvanised iron earth plate electrode 600x600x6mm buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of earth plate not less than 1.5mtr below normal ground level, connected with galvanised iron wire, size 4.0mm dia as earth lead, by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 20mm dia GI light grade protection pipe, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15, type B-1 in pit with precast RCC M-15(1:2:4), type B-1 (using 20mm graded crushed stone aggregates) in cover reinforced with XPM not less than 4.0 Kg per Sqm, test pointetc. all as shown in electric plate No-3 of SSR Part-I (2009), complete with necessary earth work in any type of soil, removal to a distance not exceeding 50mtr, including testing on completion, complete all as specified and as directed by Engineer-In-Charge.Note: Earth pit chamber and RCC pit cover shall be painted with two coats of red synthetic enamel paint over one coat of primer including preparing of surfaces. |
| 57 | LED Flood light fitting 70 Watt 230 Volt, AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed.Make: Havells cat part No- JETAADORNFLS70WLED757SSYMTOTGV2 or equivalent in Phillips/ Bajaj/ Crompton. |
| 58 | Amount of Schedule of credit as mentioned here-in-after shall be deducted from quoted amount. |