| Sl. No. | Item Description |
| 1 | Name of Work : Construction of Office Building for Joint Commissioner , Assistant Commissioner and Regional Audit office of H.R & C.E Department at Master Plan Complex, (Collector Office campus) Sivagangai . |
| 2 | Earth work excavation for foundation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 10 mts and initial lift of 2 mts. and clearing and levelling the site, etc., complete complying with standard specification. |
| 3 | Earth work excavation for Open foundation in all classes of soils and sub soils and to the depth as may be directed except in hard rock, requiring blasting, including initial leads and lifts and re-filling the sides of foundation, with excavated earth in 150mm layers well watered rammed and consolidated, including depositing the surplus earth within the compound in places shown with initial leads and lifts, clearing and levelling the site, shoring strutting baling of water wherever necessary etc., complete complying with standard specification. |
| 4 | Refilling with excavated earth other than sand with an initial head load of 100 mts. And depositing the earth as shown by the departmental officers in layers of not more than 15cm thick well rammed,watered and consolidated etc.complete complying with standard specification. |
| 5 | Supplying and filling with M. sand in layers of not more than 15 cm thick including watering, consolidation etc, complete as directed by the Engineer incharge of works and as per the technical specifications |
| 6 | Supplying and filling in Basement with filling gravel in layers not exceeding 150mm well watered rammed and consolidated including watering etc., complete complying with standard specification. |
| 7 | Cement concrete 1:5:10 (one cement five sand and ten aggregate) using 40mm gauge hard granite broken stone jelly for foundation including cost and conveyance of all materials labour for mixing, laying, compacting,curing,dewatering, side shuttering, wherever necessary including curingetc.,complete complying with standard specification and as directed. |
| 8 | Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement concrete works such as column footings, column pedestals,plinth beams,grate beams,staircase steps,etc.which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75 cm centre to centre or at suitable intervals etc.complete in all floors complying with standard specifcation.(Payment for centering shall be given after the concrete is laid) |
| 9 | Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement concrete works such assquare/rectangular column etc.complete in all floors complying with standard specifcation.(Payment for centering shall be given after the concrete is laid) |
| 10 | Supplying and erecting steel centering for sides and soffits including strutting up to 3.29 metre height for plain surface such as RCC square or rectangular columns,top and bottom slabs of sunshade boxing sill slabs etc., with necessary facia etc., with all cross bracings using mild steel B.G.,10 sheets of size 90cm x 60cm stiffened with welded mild steel angles of size 25mm x 25mm x 3mm for bording laid over silvar (oak) country wood joists of size 10cm x 6.5cm spaced at about 90cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at 75cm centre to centre complying with standard specification. |
| 11 | Beam,Lintel |
| 12 | RCC Floor Slab, Roof Slab |
| 13 | Providing and laying in position, standardised concrete Mix M-20 Grade in accordance with IS 456 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m) 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials). |
| 14 | Up to basement level |
| 15 | Above basemend level Ground Floor |
| 16 | Above basemend level First Floor |
| 17 | Concrete in second floor |
| 18 | Supplying and fabricating and placing in position M.S. grills for reinforcement for all RCC works,including cost of rods, straightening,bending,cracking typing grills,with 18 gauge galvanished binding wire and placing the grill in position etc., complete and as directed. |
| 19 | Foundation And Basement |
| 20 | Ground Floor |
| 21 | First Floor |
| 22 | Second Floor |
| 23 | Brick work using using Country Bricks of size 8-3/4\" x 4-1/4\" X2-3/4\" in Cement Mortar 1:6 (One cement and six crushed stone sand) including curing neat finishing, etc., complete complying with standard specifiction. |
| 24 | Foundation and basement |
| 25 | Ground floor super structure |
| 26 | First floor super structure |
| 27 | Second floor super structure |
| 28 | Brick Partition Wall in CM 1:3 (One Cement and Three sand) using besd qulity II class chamber bricks 9\"\"x43/8\"\"x23/4\"\" for walls including cost and conventance of all labour and materials including scaffolding curing finishing etc., complete complying with standared specification and as directed by the departmental officers. |
| 29 | Ground floor |
| 30 | First Floor |
| 31 | Plastering with C M 1:5 (one cement and five sand) 12mm thick including scaffolding finishing curing etc.,complete complying with standard specification and as directed by the departmental officers. |
| 32 | Special Celing plastering and finishing the exposed surface of RCC items of work such as slabs , beams, sunshades, with CM1:3(One cement and Three Sand ) 10mm thick including hacking the curface and providing cement mortar nosing, beading wherever necessary using the sand mix etc., complying with standard specification. |
| 33 | Paving the floor with best quality Double Charged Vitrified Tiles of size 600 x 600 x 8mm of approved colour, shade and quality laid in cement mortar 1:3 (one cement and three sand) 20mm thick in all floors and the top pointed with the white cement mixed |
| 34 | Paving the floor with cement Concrete Anti-skit Tiles (Eurocon)to required shape and design of 20mm thick approved quality and colour laid in cement mortar 1:3 (one cement and three sand)20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40kg./sq.m.,curing,etc.,complete complying with standard specfication and as directed by the departmental officers.(The make and brand of the tiles should be got approved by Executive Engineer before use on works) |
| 35 | Flooring with following ceramic tiles of size 305 x 305 x 6 mm laid over 20 mm thick cement mortar 1:3 (One Cement and Three Sand) base mortar over the existing slab / floor including cutting the tiles to the required size with special cutter wherever ne |
| 36 | Paving the floor with pre-polished concrete anti-skid step tiles (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three sand) 20mm thick and pointed with white cement mixed with colouring p |
| 37 | Providing Granolithic floor finishing with plain cement concrete 1:2:4 using 10 to 12mm HBG stone chips.etc.,20mm thick and surface rendered smooth including 150mm wide skiriting, providing proper slopes,thread lining,curing etc.,complete in all floors complying with relevant standard specifications and as directed by the departmental officers. |
| 38 | Dadooing the walls with best approved first quality colour glazed tiles of 300 x 200mm set in CM 1:2 ( One cement and two sand )10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 kg./sq.m.neatly and curing in all floors etc., complete complying with standard specification and as directed by the departmental officers. |
| 39 | Supplying casting and fixing of RCC precast jolly of the following thickness in C.C.1:2:4 (one cement two sand four stone jelly) using 20mm broken granite stone jelly excluding cost of reinforcement grill in position but including cost of all materials moulding charges casting of jally finishing,curing and fixing the jally in position and pointing the joints with cement mortar1:3 to full depth in all floors etc.complete complying with standard Specification. Precast RCC jolly-80mm |
| 40 | CRCA Pressed Steel Box Section 18 Gauge or 1.25mm thick for Door Frames including providing holes and fixing wooden blocks for fixing furniture and fittings |
| 41 | Supplying and fixing Solid core partical board flush door shutters with both sides 3mm thick commercial ply of 35mm thick with T.W internal lipping (internal alround) with necessary adheshive and C.P.screws ,including fixing of aldrops tower bolts hinges and lock strike plates,putty,fevical,varnish for T.W. lipping with thinner colouring agent etc.,The rate includes cost of materials and cost for aluminium furniture fittings such as 3 nos Alu.hinges 125mm 1 no alu.aldrop 200 x 16mm, 1 no Alu, tower bolt of 150 x 12mm and 1 no Alu, 100mm D type Handle 1 no door stopper with rupper bush incase of single leaf door inclusive of labour charges for fixing in position etc.,complete all Aluminium furniture fittings are to be anodised with matt finish under electrically controlled condition in accordance with ISI Specfication 1868/1968 for anodic flim thickness of not less than 15 microns, the rate is inclusive cost of fevical and fixing charges transportation loading unloading and all other incidential charges handling charges etc.,complete complying with standard specification.As per SOR 2020-2021 P no 48 Item no 120 |
| 42 | Supplying and fixing solid PVC door shutters using 19 Gauge 19mm MS square tubes for styles and outer frames 15mm MS Square tubes for top lock and bottom rails.the steel tubes shall be covered with 5mm thick solid PVC sheets.shutter using 5mm thick solid PVC sheets for panelling shall rigidly fixed in position including necessary furniture and fittings.the over all size of styles shall be 50mm x 30mm. The over all size of top rail and bottom rail shall be 75mm x 30mm.The over all size of frames shall be 50mm x 45mm, with sutiable rabate for housing the shutter including sliding arrangements. |
| 43 | Supplying and fixing UPVC (Un-Plasticized Polyvinylchloride) Windows of casement type (open) from theprofile the size of outer frame 60mm x 58mm andshutter profile are reinforcement with GI/1mm 125GSMand 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates ashandle. The corners and joints should be colour glass 4mm thick should be provided to thecleaned. Radiations free pin headed plain or brownwelded andcleaned. Radiations free pin headed plain or browncolour glass 4mm thick should be provided to theshutter and it should not allow leakage of water evenat most ranging storms and should have key lockableaction, security protective hinges, strong lockingsystems and as per size for arresting noise and energyloss. The connecting mechanism between sash andouter frame that enables opening of the window. Thewindow should be fixed to the wall with 100% packing.SOR page no 65 |
| 44 | Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride)Louvered Ventilators of from the profile the size of outerframe 60mm x 58mm and shutter profile size of 60 x 78mmboth profiles are reinforced with GI/1mm 125GSM and100% corrosion free, the profile are multi chamberedsections with wall thick of 2mm. The EPDM rubber (blackcolour) covered with all over the edges of frame and shutter.The corners and joints should be welded and cleaned.Radiations pin headed glass 4mm thick should be provided inthe louvers. The window should be fixed to the wall with100% packing with screws and silicon packing all round theframes. The ventilator should be got approved from theExecutive Engineer before use on work.SOR page no 66 |
| 45 | Weathering course Concrete using best Quality brocken jelly of size 20mm uniform gange in pure slacked line (no sand to be used) the proportion of brick jelly to lime being 32:12 1/2 by volume and laid over the RCC roof slab in a single layer and consolidated to the required and designed finished thickness by beating the concrete by wooden beaters of approved pattren keeping the surface constantly wet by sprinkling lime jaggery water etc.complete complying with standard.. |
| 46 | Finishing the top of roof with one course of approved best quality machine pressed square tiles of size 200x200x20mm laid in cement mortar 1:3 (one cement and three sand) 12mm thick mixed with water proofing compound conforming to indian standard as approved by the depatmental officers at 2% by weight of cement used and joints pointed neatly to full depth of tiles with same mortar mixed with water proofing compound and red oxide etc complete |
| 47 | Painting two coats with apporved water based Interior emulsion paint over cement plasterd wall surface priming coat including thorough scrapping, clean removal of dirt etc., and coveyance of all matierials all labour charges brushes,clening,preparing the surface scaffolding and curing charges etc.,complete. |
| 48 | Painting Two Coat with Water based Exterior Emulsion Paint including over priming coat in cement plasterd wall surface in all floors including all cost of materials brushes, scaffolding charges etc., complete complying with standard specification. |
| 49 | Painting Two Coat with Water based Exterior Emulsion Paint including over priming coat in cement plasterd wall surface in all floors including all cost of materials brushes, scaffolding charges etc., complete complying with standard specification. |
| 50 | Painting Two Coat with White emulsion paint for Celling Plastering complete.complying with Standard specification in all floors including all cost of materials brushes, scaffolding charges etc., complete complying with standard specification. |
| 51 | Supplying and fixing mild steel grill Gate including cost conveyance of all materials and fixing in position including priming coad etc.,complete with standard specifications. |
| 52 | Painting New iron work such as steel doors, windows, ventilators windows bars balustrades etc.,with two coats of best approved quality Synthetic enamel paint over a primring coat with ready mixed primer of approved quality Excluding cost of priming coat etc., complete complying with standard specification ( The make, quality and collour of paint should be got approved by the Executive Enginneer before use on works) |
| 53 | Supplying and fixing in position best approved of ISI qua;ity PVC rain water down fall pipes of 110mm dia with working having a pressure of 4 kg/Sq.m including cost of necessary PVC shoe , PVC bend, Grating of requried diameter and special clamps , brass screws, nails, etc. and fixing of cast iron grating at junction of parapet and the RCC roof slab including finishing neatly etc. complete . the rate shall be inclusive of cast of removable iron grating. The size of teak wood plug to be used shall be 150mm x 25mm infront and 200 x 75mm in all other sides with a depth of 100mm,the pipes to be fixed by means of U clamps screwed to the plugs as directed by the depardmental officers complying with standard specification.TNBP:SS 107. |
| 54 | Provision for fixing the outlet pipes 100mm dia |
| 55 | Manufacturing and fixing in position RCC precast slab 50mm thick in C.C. 1:2:4, using 20 mm HBGS machine crushed jelly of following thickness, excluding cost of reinforcement grill but including moulding, finishing, curing and fixing in position etc. Complete. |
| 56 | Water Supply arrangements |
| 57 | Supplying laying and jointing PVC pipes (having working pressure 10Kg/Sq.cm) of approved quality and best veriety conforming to BIS of the following dia including cutting threading and fixing PVC specials using PVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plug, PVC clamps and screws making holes on the wall or drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work/ cement concrete and plastering neatly whever necessary scaffolding charges etc., complete complying with standard specification |
| 58 | 32mm dia pipe below ground level |
| 59 | 32mm dia pipe above ground level |
| 60 | 25mm dia pipe above ground level |
| 61 | Supplying PVC specials (with working pressure 10Kg/sq.cm) in water supply arrangements (both in internal & external water supply arrangements). Note: Since the labour for cutting threading / plastering sundries have already been included under pipe line item of works, no separate provisions for fixing PVC specials need to be allowed. |
| 62 | Coupler |
| 63 | 20mm dia |
| 64 | 25mm dia |
| 65 | 32mm dia |
| 66 | Elbow |
| 67 | 20mm dia |
| 68 | 25mm dia |
| 69 | 32mm dia |
| 70 | 20mm dia |
| 71 | 25mm dia |
| 72 | 32mm dia |
| 73 | 20mm dia |
| 74 | 25mm dia |
| 75 | 32mm dia |
| 76 | Reducer |
| 77 | 25mm X 20mm |
| 78 | 32mm X 25mm |
| 79 | Reducer Elbow |
| 80 | 25mm X 20mm |
| 81 | 32mm X 25mm |
| 82 | Supplying and fixing in position first quality and approved variety of Gun metal gate valve / Wheel valve with BIS make of the following dia including cost of shellac, thread balls etc., complete complying with standard specification ( for both internal and external water supply arrangements) |
| 83 | Fixing wheel valve of dia 25mm |
| 84 | Fixing wheel valve of dia 32mm |
| 85 | Supplying and fixing in position 15mm dia brass CP screw down tap/ pillar tap (heavy duty) of approved make conforming to BIS specification and quality including cost of shellac, thread etc., complete complying with standard specification and including cutting and threading wherever necessary. |
| 86 | Pillar Tap |
| 87 | Swan Neck Tap |
| 88 | Supply and delivery and fixing of HDPE tank 1000 litres capacity as per IS 12701/1996 including loading, unloading, transportation and labour charges for fixing of the GI pipes and specials for pipe connection works including cutting, threading and fixing charges as directed by departmental officers etc., |
| 89 | Sanitary Arrangements |
| 90 | Supplying and fixing in position best quality and approved make indian made white / colour glazed earthernware wash hand basin of size 550 X 400mm (without pedestal) |
| 91 | Supplying and fixing in position of Indian make Water Closet Oriyya Type (White) of size 580mm X 440mm of approved uality with \"p\" or \"s\" trap. |
| 92 | Supplying and fixing in positon European Water Closet with \"P\" or \"S\" Trap with Double falpped seat and seat cover with Brass Hinges and 10 litre capacity low level flushing tank with all internal fittings etc., complete complying with standard specifications and as directed by the departmental officers. (The water closet should be got approved by the Executive Engineer before use on works). |
| 93 | Supplying and fixing in position Indian make white glazed earthenware squating type urinal of best quality and approved make including dismantling masonry, if necessary and re-doing the same to original condition, etc., complete complying with standard specification. (The squatting urinal should be got approved by the Executive Engineer before use on works). |
| 94 | Supplying and fixing in position of P V C Nahini Trap of size 100 x 75mm with best stainless Steel Gratings of approved make and quality, fixed over a bed of of brick jelly concrete 1:2:5 (One part of Lime, Two parts of Sand and Five parts of 40mm size brick jelly) and finished with cement mortar 1:3 ( One part of Cement and Three parts of Sand) including cost and conveyance of all materials and labour charges including dismantling the masonry works wherever necessary and making good etc complete |
| 95 | Supplying and fixing in position of PVC Ventilating shaft 110mm dia and 3m height including cost and conveyance of all materials and all labour charges for cutting fixing in position etc., complete. |
| 96 | Supplying and filling 40mm HBG stone jelly in filter bed / Dispersion trench including cost and conveyance of all materials and labour charges for fixing in position etc., complete. |
| 97 | Supplying and fixing in position of bewelled edge mirror of size 600x450 mm quality including cost of rawal plugs brass screws and conveyance of all materials and labour charges for fixing in position etc., complete. |
| 98 | Supplying and fixing in psition of c.p towel rail of size 60cm quality 20mm with brackets for best quality including cost of rawal plugs brass screws and conveyance of all materials and labour charges for, fixing in position etc., complete. |
| 99 | Supplying and fixing in psition best quality PVC soil / waste pipes of various dia having 6kg/sq.cm pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws etc., and making connection to all sanitary fitting, dismantled portion to the original condition, including testing for any leakages etc., complete complying with standard specifications. ( The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid seperately in the cases where the pipe lines are proposed to laid. |
| 100 | Above Ground Level |
| 101 | Above Ground level 160mm dia having 6kg/sq.cm |
| 102 | Above Ground level 110mm dia having 6kg/sq.cm |
| 103 | Above Ground level 90mm PVC pipe |
| 104 | Above Ground level 75mm PVC pipe |
| 105 | Below Ground level |
| 106 | Below Ground level 110mm PVC pipe |
| 107 | Below Ground level 90mm PVC pipe |
| 108 | Supplying and fixing in psition PVC specials of the following dia and types of approved quality confirming to BIS and providing leak proof joints including fixing to the wall and giving connection of PVC soil stacks, dismantling the masonry or RCC works and re-doing the dismantled portion to original condition etc., complete complying with standard specifications. ( The PVC specials should be got approved by the Executive Engineer before use on works). |
| 109 | 160mm dia PVC Elbow |
| 110 | 160mm dia PVC door Elbow |
| 111 | 160mm dia PVC Plain bend 160mm pvc elbow with Door |
| 112 | 160mm diaTee |
| 113 | 160mm dia PVC Plain Bend |
| 114 | 110mm dia PVC Elbow |
| 115 | 110mm dia PVC Door Elbow |
| 116 | 110mm dia PVC Tee |
| 117 | 110mm dia PVC Tee with Single Door |
| 118 | 110mm dia PVC Plain Bend |
| 119 | 75mm dia PVC Elbow |
| 120 | 75mm dia PVC Door Elbow |
| 121 | 75mm dia PVC Tee |
| 122 | 75mm PVC Tee with Single Door |
| 123 | 75mm dia PVC Plain Bend |
| 124 | Supplying and fixing in psition PVC cowls of the following dia of approved quality confirming to BIS, etc., complete complying with standard specifications. ( The PVC cowls should be got approved by the Executive Engineer before use on works). |
| 125 | 110mm dia PVC Cowl (including w.c top level pipe) |
| 126 | 75mm dia PVC Cowl trap top level |
| 127 | Supplying and filling 40mm HB Jelly in Dispersion trench etc complete cuplying with standard specification. |
| 128 | Supplying and filling 20mm HB Jelly in Dispersion trench etc complete complying with standard specification |
| 129 | Supplying and fixing GI 40mm pipes above GL for following sizes including cost of materials to site and labour charges etc complete as per standard specifications |
| 130 | Supplying and fixing stone ware pipe 150mm dia tight joints etc cuplying with standard specifications |
| 131 | Supplying and fixing stone ware pipe 150mmdia Loose joints etc complying with standard specifications. |
| 132 | Wiring with 2 x1.5 sq.mm. (22/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) ( 5 points / Coil) Lower End (DATA A) |
| 133 | Wiring with 2x1.5 sqmm (22/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessoires with metal box and 6A 1way modular Switch in flush with wall with suitable modular front plate cover for making good of the concealed portion for PVC concealed light point /fan point for Electronic Regulator) (6 Points Per Coil) (Anchor Roma/Equivalent) (DATA -B) |
| 134 | Supply and fixing of single box type 4\"20 W LED fitting with TW round blocks on wall or celling with PVC unsheathed Copper leads from terminals to the fitting. (DATA - C) |
| 135 | Supply and fixing of WT bulk head fitting with guard suitable with 7W / 9W LED bulb (SD-84) |
| 136 | supply and fixing of 30W LED street light fitting with LED (Lower end) with 25mm dia. GI pipe (class B) with 1 no.25mm GI bend complete on the existing post/ on wall with PVC unsheathed copper leads with MS clamps and with painting . (SD 447) |
| 137 | supply and fixing of 1200mm (48\") sweep AC ceiling fan complete ( Higher end) with 2 module 100W fan step regulator (Higher end) with 1 metre down rod on the existing fan clamp (SD 482 ) |
| 138 | Supply and fixing of 300mm (12\") sweep (light duty) AC exhaust fan complete without provision of hole in the wall (SD 115) |
| 139 | Supply and fixing of louvers shutters arrangements for 300mm (12\") sweep (light duty) AC exhaust fan (SD 120) |
| 140 | supply and fixing of 24W LED 2x2 square type Recessed fitting with LED (Lower end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting. (SD-440 ) |
| 141 | Supply and fixing of 3 nos.6A two module 5 pin socket , 3 nos. 6A one module switch with module cover plate (plastic) on suitable module concealed Box ( GI ) in flush with wall with connections. Lower End (SD 390) |
| 142 | Supply and fixing of Douple pole sheet steel enclosure with 1 no 40 A DP MCB on wall and necessary connection for Common Toilet Block (DATA D) |
| 143 | Supply and fixing of 1 no.6A two module 5 pin socket , 1 no. 6A one module switch with module cover plate (plastic) on suitable module concealed Box ( GI ) in flush with wall with connections. Lower End (SD 378) |
| 144 | Supply and fixing of 1 no.6/16 A two module socket , 1 no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box ( GI ) in flush with wall with connections. Lower End (SD 402) |
| 145 | Supply and fixing of 20Amp MC plug with 3 pin Top for AC unit in flush with wall with earth connection complete. (DATA E) |
| 146 | Supply and fixing of 20A Double pole MCB in sheet steel enclosure in flush with wall and making good of the concealed portion with necessary earth connection. (The MCB and metal enclosure should be of Higher End).( for Ac control). (DATA- F) |
| 147 | Supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 40 A DP MCB Isolator as incoming and 10 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Lower End (SD 527) |
| 148 | Supply and fixing of 8 way Vertical TPN Distribution Boards (with MCCB Incomer); Double Door; IP43, as per IS 8623 III; Impact resistance IK09; Frame MCCB Incomer & Single Phase/Three Phase MCBs as Outgoing (for power loads exceeding 100A) , with100A 4 Pole MCCB as incoming and 4 nos 63A TP MCB,12 nos 6A -32 A SP MCB as Outgoing on suitable angle iron frame on wall with earth connection only. The MCB DB and MCCB\"s should be with ISI mark (like legrand make) (DATA G) |
| 149 | Supply and fixing of 8 way Vertical type triple pole neutral MCB Sheet steel enclosure distribution board with double door Metal with IP42 Protection, with 63 A 4 Pole MCB as incoming with 3 Nos 32A TP MCB and 15 Nos 6 A to 32A SP MCB as outgoing in flush wall with earth connection only. The MCB DB and MCB\"s should be with ISI mark (SD-584) |
| 150 | Supply and Run of 2 of 2.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection of 2.5 sq.mm copper wire and making good of the concealed portion (SD 337) |
| 151 | Supply and run of 2 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 4 sq.mm copper wire and making good of the concealed portion with suitable colour (SD 57) |
| 152 | Supply and Run of 4 of 10 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 10 sq.mm copper wire and making good of the concealed position. (SD- 347) |
| 153 | Supply, erection,testing and commissioning of 2 Ton (6000 K.Cal/Hr) ABS Plastic split type Air conditioner confirming to is : 1391(part 2) 1992 Amdt No.1 to 2 fitted with Rotory compressor operating Refrigerant R.22/ Non CFC suitable for wall mounting for operating on 230 voltrs, 50 HZ single phase AC supply with star rating of 3 as per BEE specification and capable of performing the functions of 1) Cooling 2) De humidifying 3) Air circulating 4) filtering. |
| 154 | The installation works for the above split type AC units includes the followings. Mounting/fitting in door and out door units at the respective locations. |
| 155 | 1. Laying Refrigerant pipe line of required length connecting both units after drilling hole/holes in the wall if required. Thickness of copper tubing shall not be less than 0.7mm. 2. Insulating the suction pipe with expanded polyethylene foam 5 mm tubing. 3. Laying 15mm dia Flexible PVC drain pipe to throw out. The condensate water being formed within Indoor unit. 4. Leakage testing the entire system with outdoor unit stand. 5. Charging Refrigerant gas in the unit. 6. Suitable electric wiring to be provided with 2.5 sqmm. PVC insulated copper wire between indoor and out door units up to 6 meters length and up to Switch within 3 meters of location of in door Unit. (Carrier/voltas) (DGS & D Rates) (M-1984) |
| 156 | Renewal by supply and installation of 5.0 KVA Electronic Automatic voltage stabilizer V-Guard Make with input voltage Range of 170 volt to 270 volt and output voltage range 200 volts to 240 volts with High and low voltage cut off and 3 minutes time delay relay with demonstration (M-1989) |
| 157 | Supply and fixing of MS stand for fixing Spilt Airconditioner Outdoor Unit. (SR-M-1991) |
| 158 | Earthing as per the ISI specification with an earth electrode of 2.1mt class \"B\" GI pipe of dia not less than 40mm, with copper earth plate of size 125mm x 50mm x 6mm, with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry . (SD 211) |
| 159 | Supply and Run of 1 of No.8 SWG copper wire in suitable PVC rigid pipe on wall / floor / ground for earth connection (SD 371) |
| 160 | Supply and run of 4X 16 Sqmm pvc insulated SC unsheathed copper conductor of 1100volt grade on 7/20 GI wire for service connection mains(DATA H ) |
| 161 | Supply and run of 4X 16 Sqmm pvc insulated SC unsheathed copper conductor of 1100 volt grade in 50mm dia GI pipe class B suitable bend at both ends with necessary angle iron upright ad end supports for service connection mais .(DATA-I ) |
| 162 | Supply and Laying of 3 1/2 x 50 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. (SD 661) |
| 163 | Supply and clamping of 31/2 x 50 sq.mm PVC LTUG armoured cable on post or wall with MS clamps (SD 202) |
| 164 | Supply and frxing of brass cable gland for 3-1/2 x 50 sq.mm. PVC armoured LTUG cable with earth connection (SD 166) |
| 165 | Supply and providing cable end terminaton of 3-1/2 x 50 sq.mm PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete ((SD 215) |
| 166 | Supply and Laying of 2 x 16 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. (DATA J ) |
| 167 | Supply and clamping of 2 x 16 sq.mm PVC LTUG armoured cable on post or on wall with MS clamps. (SD 195) |
| 168 | Supply and fixing of brass cable gland for 2 x 16 sq.mm. PVC armoured LTUG cable with earth connection (SD 161) |
| 169 | supply and fixing of 65 mm dia. (2 -1/2\") GI pipe (class B) of 6 metre length with 300mm x 300mm x 6mm MS base plate duly welded at the bottom with concreting with construction of masonary pedestal with suitable SMC box with door arrangement to house 6A SP MCB switch, 2/4 way connector on suitable hylem sheet and supply and fixing of 48W LED street light fitting with LED (Higher end) with 1 metre 32mm dia. GI pipe (class B) Complete with suitable MS clamps for LED steet light fitting and SMC box with PVC unsheathed copper leads from SMC box to fitting and with painting of suitable colour . (SD 456) |
| 170 | Supply and fixing of 100 A Three phase 500V 4 Pole Change over Switch on suitable angle iron frame work with MS cable entry boxes with earth connection only (SD 649) |
| 171 | Supply and fixng of TNEB meter board suitable for 3phase 100A service connection madeup of suitable angle ironframe workofsize2feetx1-1/2 feetusingangleironofsize1-1/2\"x1-1/2\"x1/4\"rigidly fixed on wall covered with hylem sheet of size 2feetx1-1/2 feet of 12mm thickness with necessary bolts and nuts supports and supply and fixing of 3Nos.100A fuse units(500V),1No.neutral link,copperearthflatofsize1\"x1/4\"with interconnection of EB meter to fuse units by 16 Sq.mm PVC insulated copper wire with100A ,30mA Sensitivity RCCB with earth connection complete.(DATA K ) |
| 172 | Supply and run of 4 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 4 sq.mm copper wire and making good of the concealed portion with suitable colour (SD 61) |
| 173 | GENERATOR |
| 174 | Supply, Testing Commissioning and Handing over of 58.5 kVA/32KW 0.8P.F, 3 ph, 415 Volts, 50c/s, 1500 RPM diesel generator set with Standard Panel with acoustic enclosure conforming to CPCB IV+ Emission Standard and BIS Specifications as detailed below including transporting & unloading charges. |
| 175 | Providing suitable concrete foundation suitable for 58.5kva generator set with pcc 1:2:4 using20mm jelly for wearing coat including laying compacting finshing and curing etc |
| 176 | SOLAR |
| 177 | Supply, Installation, Testing, Commissioning and Handing over of 20KWp Grid connected roof top Solar Photo Voltaic (PV) System Scheme complete as detailed below. |
| 178 | Scope of the proposal:1) MonoCrystalline PERC Solar PV Modules 2) Module Mounting Structure 3) Array junction boxes4) DC Distribution box5) Inverter / PCU6) AC Distribution box7) Energy Meter8) Protection - Earthing, Lightning, Surge9) Cables10) Drawing & Manuals11) Miscellaneous |
| 179 | Supply and clarnping of 3-1/2 x 25 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps (SD 200) |
| 180 | Supply and fixing of brass cable gland for 3-1/2 x 25 sq.mm. PVC armoured LTUG cable with earth connection (SD 164) |
| 181 | Supply and providing cable end termination of 3-1/2 x 25sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete (SD 213) |
| 182 | Supply and fixing of Four pole sheet steel enclosure with 1 no 63 A FP MCB on wall and necessary connection for Solar (DATA L) |
| 183 | GST Amount for providing Service to Government Contract Works for the above Construction Works. { GST Amount is the Total GST Amount for total overall quoted amount above this row in column \"BB\" for all works in this package} Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail