| 1 | Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed |
| 2 | S&F Prepainted galvalume aluminium zink coating GI based corrugated/semi corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 3 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws ,complete all as specified and as directed. |
| 4 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 5 | S&F Rolled sections as in main and cross beams, hip and jack rafters;purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates.confirming to Fe.410W. Gde-E- 250) quality A) including necessary preperation of surfaces and applying one shop coatof red oxide, zinc chrome primer complete all as specified and as directed. |
| 6 | Taking out existing unserviceable water roof treatment of any descriptionfrom RCC roof slab, parapet etc including Cleaning of old concrete surfaces of roof, picking sweeping cleaning the surface to remove all loose dust and thoroughly washing down with clean water and dried complete all as specified anddirected . |
| 7 | M&L Rendering 10mm thick in CM (1:4) mixed with and including water proofing compound as per manufacture instructionon existing roof surface true to level after applying cement slurry @ 3Kg/Sqm over RCC slab complete all as specified anddirected. |
| 8 | M&L PCC 25mm thick average thickness Type B0 (using 20mm graded aggregate) as levelling course to roof surfaces finished even and fair including demolition of existing unserviceable PCC padding complete all as specified anddirected. |
| 9 | M&L for water proofing treatment to RCC roof slab, including parapet comprising with the following course of treatment/specification from bottom to top, complete all as specified and directed:-(i) Applying one coat of bituminous primer @ 0.40 Ltr/Sqm.(ii) Supply and laying 3mm thick APP based olymeric membrane of approved manufacturer with weight not less than 3.50 Kgs per Sqm, reinforced with non-woven polyester febric weight not less than 160gms per Sqm.Polymeric membrane shall be taken to a height of 30cm(minimum) and than inserted inside the groove of parapet wall and shall be finished by a membrane flashing.(iii) One coat of Solar reflective bituminious Aluminium paint of approved brand to be provided over the APP membrane as per manufacturers instructions. Note : (a) Work shall be carried out through specialized applicator approvrd by GE. Contractor shall submit sufficent documents/Credentials in support of Applicator whom he wants the work excuted.(b) Laying APP based polymeric membrane shall be done torch on method as per manufactures instructions. (c) A minimum overlap of 100mm and 75mm should be made at the endand sides of the polymeric membrane respectively and sealed alloverlaps and joints as per manufacturers instruction |
| 10 | Taking down Chowkhats or frames not exc. 1.5 sq. m each but with shutters (without taking off shutters from the frames)complete all as specified and as directed. |
| 11 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, fixed in opening as specified in SSR Part I, Section 8 complete all as specified and as directed. |
| 12 | S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes far top and bottom rails, MS frame shall be covered with heatmoulded plain colour PVC “C” channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail;Paneling of plain colour PVC sheets to be fitted in the MS frame welded / sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent cementas per specification & drawing as specified in SSR Part I, Section 8 complete all as specified and as directed. |
| 13 | S&F powder coated (minimum thickness of poweder coating 50 micron) anodised aluminium frame for doors, windows, ventileters with one or more rebates including joining cleat for fixing etc complete all as specified and as directed. |
| 14 | S&F Powder coated Anodised aluminium (minimum thickness of powder coating 50 micron) window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.), hinges type B-21 100mm long (2 no.) suitable handle (1no.) complete all as specified.Note:-(i)Glass/wire guage as required shall be measured and paid seperately under appropiate item (ii) Design/pattern, profile sizes and other dimensions shall be of standard sizes and as directed |
| 15 | S&F 100mm Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 complete all as specified anddirected . |
| 16 | S&F 150 mm Extruded aluminium alloy handles, fabricated type, anodised, complete all as specified and directed. |
| 17 | S&F 150mm long aluminium anodised barrel tower bolts of extruded section, complete all as specified and directed. |
| 18 | Dismantling Wall and ceiling boards (fibre,pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and as directed. |
| 19 | S&F Anodised aluminium snap grid frame work for false ceiling,Size of grid 605 x 605mm, (size of main runner 39x24.7x0.8mm, cross Tee 29x24.7mmx0.8mm, wall flange 22.2x22.2x0.65mm) hanging with 4mm dia GI wire suspenders from roof, ‘J’ hooks bolts and nuts etc,with and including 4mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to Aluminium framework with screws,complete all as specified anddirected . |
| 20 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing debries/ rubbish from the site complete all as specified and directed. |
| 21 | M&L Glazed ceramic coloured tiles in vertical surfaces 450x 350x 7 mm thick set and jointed in neat cement slurry & pointed in white or colour cement to match including backing coat 10 mm thick in Cement Mortar 1:4, complete all as specified and directed. |
| 22 | M&L Virified Light shade Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick Screed bed or bedding layer of cement mortar 1:6,for laying floor finishes, complete all as specified and directed. |
| 23 | M&L Virified Light shade Ceramic tiles 10 mm thick (square/ rectangular) polished, size of tile 600x600mm, in Vertical surfaces, dadoo/skirting etc. set and jointed in neat cement slurry and pointed in white or coloured including 10 mm thick Screed bed or bedding layer of cement mortar 1:4, complete all as specified and directed. |
| 24 | M&LNon - skidcoloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured including 15 mm thick Screed bed or bedding layer of cement mortar 1:6,for laying floor finishes, complete all as specified and directed. |
| 25 | M&LNon - skidcoloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured including 15 mm thick Screed bed or bedding layer of cement mortar 1:6,for laying floor finishes, complete all as specified and directed. |
| 26 | M&LNon - skidcoloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, Vertical surfaces, dadoo/skirting etc. set and jointed in neat cement slurry and pointed in white or coloured including 10 mm thick Screed bed or bedding layer of cement mortar 1:4, complete all as specified and directed. |
| 27 | Dismantling Stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar complete all as specified and directed. |
| 28 | M&L Heavy duty coloured vitrified tiles 300x 300x 8-10mm thick set and jointed in neat cement slurry & pointed in white or colour cement to match set and jointed in neat cement slurry and pointed in white or coloured including 15mm thick Screed bed or bedding layer of cement mortar 1:6,for laying floor finishes,complete all as specified and directed. |
| 29 | M&L Heavy duty coloured vitrified tiles 300x 300x 8-10mm thick set and jointed in neat cement slurry & pointed in white or colour cement to match set and jointed in neat cement slurry and pointed in white or coloured as in vertical surfaces, such as dadoo/skirting etc including 10mm thick Screed bed or bedding layer of cement mortar 1:4, complete all as specified and directed. |
| 30 | Demolition of unreinforced cement concrete in of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 31 | M&L 75mm thick cement concrete (1:3:6) type C-2( using 40mm graded crushed stone aggregate) as in plinth protection laid in alternatebays (not exceeding 2 Sqm each)and finished even and smooth without using extra cement and providing jointsthroughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified and directed. |
| 32 | M&L 100mm thick plain cement concrete type B2 (1:2:4) using 40mm graded stone aggregate as in Cement concrete in floor laid in alternatebays (not exceeding 2 Sqm each)and finished even and smooth without using extra cement complete all as specified and directed. |
| 33 | Demolition Brickwork or stone/boulder masonry, built in cemnt mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified anddirected . |
| 34 | M&L brick work with sub class \"B\" bricks, old size bricks, straight or curved on plan exceeding 6m mean radius built in cement mortar (1:6) complete all as specified and directed. |
| 35 | M&L for Brickwork with burnt old size bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 complete all as specified and as directed. |
| 36 | Taking down cement plaster on wall & ceiling of any description including racking out joints, hacking for key and scrubbing down with water etc complete including removing debries of the site complete all as specified and as directed. |
| 37 | M&L forrendering 20mm thick with cement mortar 1:4on fair faces of brick workin two layers (10mm and 10mm) sperately mixed with water proofing compund in top layer as per manufacturers instruction and finishing the surfaces even and smooth witout using extra cementcomplete all as specified and directed. Note:- WPC shall be measured & paid separately |
| 38 | M&L for Rendering 15 mm thick on other thanfair faces of brick work or concrete surfaces in cement mortar 1:6 for finished even and fair complete all as specified and as directed. |
| 39 | M&L for Rendering 5 mm thick on concrete surfaces as in ceiling in cement mortar 1:3 for finished even and fair including necessary preperation of surfaces complete all as specified and as directed. |
| 40 | Supply only Integral waterproofing compound complete all as specified and directed |
| 41 | M&L for preparation of new wall surface applying Two or more coats of 100% Premium acrylic exterior emulsion paint with silicone additives of required shade additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @2.20 litre/ 10 sqm complete all as specified and directed. |
| 42 | M&L for preparation of new wall surface applying Two or more coats of Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer\"s specificationover new surface over 1 mm thick wall care putty,complete all as specified and directed. |
| 43 | M&L for preparation of new Ceiling surface applying Two or more coats of Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer\"s specificationover new surface over 1 mm thick wall care putty,complete all as specified and directed. |
| 44 | Supplying and laying of 20mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings laid in floors fixed to walls and ceilings or laid in floors, including taking out old unserviceable 15mm bore GI pipe complete all as specified and as directed. |
| 45 | Supplying and laying of 25mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings laid in floors fixed to walls and ceilings or laid in floors including taking out old unserviceable 20mm bore GI pipe complete all as specified and as directed. |
| 46 | S&F in repair, vitreous China wash basin, white, flat back, size 550x400mmincluding brackets cutting forand pinning in ends of brackets or erecting stand including15mm bore pillar taps, cast copper alloy with capston heads, chromium plated,fancy type, screwed down high pressure, with or without lettered hot or cold with long screwed shanks and fly-nuts, screwed for iron pipe and PVC connection 15mm size with PTMT nuts, 450mm long complete all as specified and as directed. |
| 47 | S&F in repair, Vitreous China squatting pan \"Orissa\" pattern size 630x450mm white with integral foot rest , including S or P traps (Excluding flushing cistern & flush pipe), laid over 150mm thick cement concrete (1:5:10) type E2 using(40mm graded aggregate), complete all as specified and directed. |
| 48 | M&L 15mm thick plaster of cement mortar (1:3) rendering on brick work or concrete surfaces of sunken slab mixed with and including water proofing compound as per manufacturer\"s instructions finishing the surface fair and even without using extra cement complete all as specified and as directed. |
| 49 | M&L applying two coats of PU based liquid single component elastomeric water proofing menbrane on sunken slab complete all as specified and as directed. |
| 50 | M&L 25mm avearage thickness Type B0 (using 12.5mm graded aggregate) as levelling course/floor of sunken floor finished even anf fair complete all as specified and directed. |
| 51 | S&F 25mm bore GI pipe (light grade) spout, 45 cm long complete in all as specified and as directed. |
| 52 | S&F in repair, 25mm bore Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 25mm - 455gms), complete in all as specified and as directed. |
| 53 | S&F in repair, 15mm bore two way Bib taps, fancy type, chromimum plated cast copper alloy, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed. |
| 54 | S&F in repair, health faucet suitable for 15mm dia pipe, 1.25 meter long easy flexible tubein chrome finish & wall hook all as specified and as directed |
| 55 | S&F in repair Vitreous China wash down water closet pan, pedestal pattern white (excluding flushing cistern and flush pipe) including Plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and as directed |
| 56 | S&F in repair 10 ltrs capacity low level valve less PVC syphonic action type flushing cistern white with inlet ball valve float and handle, PVC flush pipe,including PVC connection 15mm size with PTMT nuts, 450mm longcomplete all as specified and as directed. |
| 57 | S&F in repair 15mm bore pillar taps, cast copper alloy with capston heads, chromium plated,fancy type, screwed down high pressure, with or without lettered hot or cold with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified and as directed |
| 58 | S&F in repair, 125mm Brass chromium plated shower rose with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and as directed. |
| 59 | S&F in repair,15mm bore Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed. |
| 60 | S&F in repair 15mm bore Bib taps, fancy type, chromimum plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed. |
| 61 | S&F in repair, Brass chromium plated Tubular towel rail, 20mm dia, D type, 60cm long between flanges completeall as specified and directed. |
| 62 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., (measured overall as fixed along the centre line over fittings and accessories)complete all as specified and as directed. |
| 63 | S&F 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/Ceilings complete all as specified and as directed. |
| 64 | S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/Ceilings complete all as specified and as directed. |
| 65 | S&F 75mm bore PVC (SWR) bends of any radius complete all as specified and as directed. |
| 66 | S&F 110mm bore PVC (SWR) bends of any radius complete all as specified and as directed. |
| 67 | S&F 110mm bore PVC (SWR) junction single,(Single T) equal or unequal of any radius, with access door complete all as specified and as directed. |
| 68 | S&F 75mm bore PVC (SWR) Cowl complete all as specified and as directed. |
| 69 | S&F 110mm bore PVC (SWR) Cowl complete all as specified and as directed. |
| 70 | S&F 110mm bore Stack clamps out of 50mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and as directed. |