| 1 | M & L for excavating in post holes in soft / loose soil (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed. |
| 2 | M & L for cement concrete type C2 1:3:6 (Using 40mm graded aggregate)as in post holes complete all as specified and directed. |
| 3 | S & F Steel work in joist,channel,angle,or teesections, fixed independently, without connecting plates, etc.including tubular poles/purlin/rafterspecial shaped washer etc. complete using Fe 410-W (Gde-E-250 quality-A) complete as specified and directed. |
| 4 | S&F Pre-coated galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 5 | S&FPre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed. |
| 6 | Preparation of new steel surfaces exc 10 cm width or girth and applying two coats of syntetic enamel paint overone coat of red oxide of zinc chrome primer complete all as specified and directed. |
| 7 | M&L for 40 mm thick PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in sub base floor / pavings complete all as specified and directed. |
| 8 | M&L for 75 mm thick PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in sub base floor / pavings complete all as specified and directed. |
| 9 | M&L for brick work with fly ash bricks old size bricks in cement mortar, straight or curved on plan exc. 6 m mean radius, built in CM (1:6) complete all as specified and directed. |
| 10 | M&L for 15mm thick in CM 1:4 rendering on fair faces of brick work is to be finished even and smooth (without using extra cement) complete all as specified and directed. |
| 11 | M&L for two coat of antifungal acrylic paint exterior grade (100% Acrylic) over a one coat of primer including prepartion of newly plasterd surfaces of walls etc all specified on external surfaces.Note:The aforesaid treatment shall be executed by the contractor from an authorised applicator of the manufacturer(s) and also necessary authenticated documents on account of above shall be submitted by the contractor to MES Department. |
| 12 | Taking down carefully copper/aluminum point wiring for light, fan, bell, socket or power complete including fittings such as switches, ceiling roses pendents regulators, sockets, Tube lights etc, removing materials from site and serviceable material re-use at site and making good distrubed surface of wall, floors etc all as specified and directed. |
| 13 | M & L for point wiring complete with proper colour coding using, 1100 Volts grade, 1.5 Sqmm, PVC insulated FRLS, unsheathed wire with multi stranded copper conductor confirming to IS-694, Part II, ISI markedconcealed wiring drawnin PVC conduit and including(minimum 20 mm dia) fixed under the surfaces of wall, ceiling etcwith all accessories, with sunken iron pressed steel terminal box 2 mm thick, PVC junction boxes etc, also including 1.5 Sqmm, PVC insulated, FRLS, unsheathed, 1100 Volts multi stranded copper conductor green colour as continuous earth wire connected to common earth dolly all as specified and directed. |
| 14 | One light point controlled by one switch |
| 15 | One fan/ Exhaust fan point controlled by one way switch |
| 16 | One 5A 2pin/3pin socket on same board. |
| 17 | One bell point controlled by one switch |
| 18 | One 3 pin socket point 5A controlled by switch on independent board |
| 19 | All as per item No 13 above but for 3 pin socket outlet 15 Amp independent with cable 2.5 sqmm unsheathed stranded 1100 Volts grade complete with 2.5 sqmm PVC insulated earth wire and connecting to earth dolly all as specified and directed. |
| 20 | S&F switch piano type 5 Amp single pole one way complete all as specified and directed. |
| 21 | S&F ceiling rose surface backelite, three terminal complete all as specified and directed. |
| 22 | S&F bell push 5 Amp piano type single pole 230 volts one way complete all as specified and directed. |
| 23 | M&L forsocket outlet 2 in 1,3/5 pin 5 Amps multi-purpose flush type. |
| 24 | S&F switch socket combination multi-purpose 5 pin 5 Amp flush type complete all as specified and directed. |
| 25 | S&F switch socket combination multi-purpose 15 Amp, 2 in 1, 3 /5 pin flush type complete all as specified and directed. |
| 26 | S&F in repair ceiling fan regulator socket type 230V, all as specified and directed. |
| 27 | Supply and fixin repair of Modular bell push, 6 Amp, 1 module, complete all as specified and directed. |
| 28 | Supply and fixin repair of modular switch, 1 way, 6 Amp, 1 module, complete all as specified and directed. |
| 29 | Supply and fixin repair of modular switch, 1 way, 16 Amp, 1 module, complete all as specified and directed. |
| 30 | Supply and fixin repair of Modular socket outlet, 6 Amps, 2/3 pin combined 2 module, complete all as specified and directed |
| 31 | Supply and fixin repair of Modular socket outlet 6A/16 Amps, 2/3 pin combined 2 module, complete all as specified and directed |
| 32 | Supply and fixin repair of modular fan step regulator, 120W, 2 module, complete all as specified and directed. |
| 33 | S&F LED indoor decorative aluminum housing LED batten integrated type tube light fitting, suitable and includingwattage 20W, rated input voltage 140V AC – 270V AC, driver efficiency 88%, Lumens efficiency 100 lm/W, starting voltage 90V, THD<=20, color rendering index (CRI).80, Color temperature 6500K, No harmful radiations, inbuilt surge protection 2.5 kV, isolation 3.75kV, Zero mercury content , complete with all accessories internally pre wired and including connected up with twin core twisted flexible copper conductor cable with suitable sizes all as specified and directed. |
| 34 | S&F LED indoor decorative polycarbonate housing LED batten integrated type tube light fitting, suitable and includingwattage 10W, rated input voltage 140V AC – 270V AC, driver efficiency 88%, Lumens efficiency 100 lm/W, starting voltage 90V, THD<=20, color rendering index (CRI).80, Color temperature 6500K, No harmful radiations, inbuilt surge protection 2.5 kV, isolation 3.75kV, Zero mercury content , complete with all accessories internally pre wired and including connected up with twin core twisted flexible copper conductor cable with suitable sizes all as specified and directed. |
| 35 | S&Fin repairs of angular batten holder PVC / poly carbonate body and brass internal parts with back plate mounted on PVC square box complete |
| 36 | S&Fin repairs LED lamp, 9 Watt, 2 star rated, rated input voltage 140V AC – 270V AC, 810 lm,Color temperature 6500K, No harmful radiations, all as specified and directed. |
| 37 | Taking down main switches DBs with sheet metal enclosure 2/4/6/8/12 way SPN/TPN/DBs etc all as specified and directed. Make - Havells/ ABB/ Legrand or equivalent. |
| 38 | S&F in repairs of MCB DBSPN08way double door, 240 Voltswith 200 rated bus barcomplete all as specified. Make- Schneider/ Havells/ ABB/ Legrand or equivalent. |
| 39 | S&F in repairs of MCB DBSPN12 way double door, 240 Voltswith 200 rated bus barcomplete all as specified.Make- Schneider/ Havells/ ABB/ Legrand or equivalent. |
| 40 | S&Fin repairs of MCB SP 240 Volts 6 to 32 Amps, ‘B’ curve type complete all as specified and directed. |
| 41 | S&Fin repairs of MCB SPN 240 Volts 6 Amp to 32 Amp complete all as specified. |
| 42 | S&Fin repairs of MCB SPN 240 Volts 6 Amp to 40-63 Amp complete all as specified. |
| 43 | Taking down and opening / dismantling of ceiling fan, cleaning complete, oiling / greasing including replacement of capacitor/worn out parts e.g. bearing, bush, shaft, etc. where necessary, checking for smooth running including painting with one coats of synthetic enamel paint cleaning and preparing the surface and refixing, testing and commissioning complete all as specified and directed. Note : Spare parts like capacitor, bushand bearing will be measured and paid separately under respective items. |
| 44 | Taking down and opening / dismantling of ceiling fan, 1200/1400 mm sweep and taking out old unserviceable winding andM & L for rewinding the same with super enameled copper wire of existing/same gauge including all insulating material required as per standard practice, varnishing the same and drying, cleaning the fan bearing/bushing and greasing/oiling and reassembling, testing complete including spy painting with one coats of synthetic enamel paint after preparing rusted surface and refixing, testing and commissioning complete all as specified and directed. Note : 1) Spare parts like capacitor, bush and bearing will be measured and paid separately under respective items. 2)Fan winding warranty will be one year. |
| 45 | Taking down and opening / dismantling of exhaust/ ventilation fan, 200/250/300 mm sweep and taking out old unserviceable winding andM & L for rewinding the same with super enameled copper wire of existing/same gauge including all insulating material required as per standard practice, varnishing the same and drying, cleaning the fan bearing/bushing and greasing/oiling and reassembling, testing complete including spy painting with one coats of synthetic enamel paint after preparing rusted surface and re-fixing, testing and commissioning complete all as specified and directed. Note : 1) Spare parts like capacitor, bush and bearing will be measured and paid separately under respective items. 2) Fan winding warranty will be one year. |
| 46 | Supply and fixbearing Suitablefor existing ceiling fan of 1200/1400mm sweepcomplete all as specified and directed. |
| 47 | Supply and fixbush Suitablefor existing exhaust fan of 200/250/300 mm sweepcomplete all as specified and directed. |
| 48 | Supply and fix bush Suitablefor existing ceiling fan 1200/1400mm sweep complete all as specified and directed. |
| 49 | Supply and fixshaft Suitablefor existing ceiling fan of 1200/1400mm sweep complete all as specified and directed. |
| 50 | Supply and fix capacitor 1.5 mfd capacity230 volts complete all as specified and directed. |
| 51 | Material and labour in repair of submain wiringcomplete with two core04sqmm (nominal core) PVC insulated unsheathed 1100 volts grade FRLS cable multi stranded copper conductor single core in PVC conduit/Casing capping of suitable size complete with one core of 04 sqmm PVC insulated unsheathed, FRLS green colour copper conductor as earth wire connecting to earth dolly. Note:- 02 run of 4 sqmm and 01 run of 4 sqmm wire and one run of PVC conduit/casing cappingshall be measured as one Running Meter length). |
| 52 | Material and labour in repair of submain wiringcomplete with two core06sqmm (nominal core) PVC insulated unsheathed 1100 volts grade FRLS cable multi stranded copper conductor single core in PVC conduit/Casing capping of suitable size complete with one core of 06 sqmm PVC insulated unsheathed, FRLS green colour copper conductor as earth wire connecting to earth dolly. Note:- 02 run of 6 sqmm and 01 run of 6 sqmm wire and one run of PVC conduit/casing cappingshall be measured as one Running Meter length). |
| 53 | M&L in replacement of Earthingcomplete withgalvanizedsteelearthelectrode60Cmx 60Cm x 6 mm thick directly buried in ground ( earth pit not less than 2.25 M deep below the normal ground levelconnected togalvanized earth lead wire 4 mm dia by means ofbolts, nuts, check nuts and washersof galvanizediron steel includingnecessary excavationearth workPCC chamberCI chamber cover protectionpipe wateringpipe etc. (Complete all as shown in electrical plate No 3 and connectedto earthing testpointcompleteincluding excavation earthwork,PCC chamber, chamber cover, funnel watering and protection pipe etc allspecified anddirected. |
| 54 | S & F in repairs heating element of 1.5 kw / 2.0/3.0 kw including rubber washer ISI marked any type complete all as specified and directed. |
| 55 | S&F in repairs thermostat for water storage heater SP 230V complete all as specified & directed |
| 56 | S&F in repairs non return valve 15 mm dia & connecting of complete heavy duty ISI marked complete all as specified & directed |
| 57 | S&F in repairs safety valve / high pressure release valve 15 mm dia ISI marked complete all as specified & directed |
| 58 | S&F in repairs indicator neon lamp 230 volts SP square or round complete all as specified & directed |
| 59 | S&F in repairs connection pipe of 45 cm long stainless steel anti slip technology,anti explosion design complete all as specified & directed |
| 60 | S&F Modular AC Box With 20A SP MCB, Metal Enclosure & Unbreakable Heavy Duty With ISI Plug Top. |
| 61 | Cleaning of underground sump by draining pumping out water/sludge from bottom by blocking all pipes against choking removing algae and growths from wall/floors/roof high pressure cleaning methodwith rotary sets with chemical treatment (Chemical approved by FOA/WHO) to make the sump clean and bacteria free of capacity of sumps50,000 gallons and including disposal outside MD land all as specified and directed. Note: Tank cleaning once in a six months and quoted rate is deemed fit for one time cleaning only. |
| 62 | Taking out old rusted GI tubing from trench or taking down from wallof size 40/50 mm bore all as specified and directed. |
| 63 | S&F in repairs GI tubing medium grade ISI markedincluding all fittings laid in trenches / fixed on wallof size 50 mm bore complete all as specified and directed. |
| 64 | S&F in repairs GI tubing medium grade ISI markedincluding all fittings laid in trenches / fixed on wallof size 40 mm bore complete all as specified and directed. |
| 65 | S&F in repairs GI tubing medium grade ISI markedincluding all fittings laid in trenches / fixed on wallof size 25 mm bore complete all as specified and directed. |
| 66 | M&L in repairs gun metal gate or globe valveswith iron wheel head (ISI Marked), screwed bothends for iron pipe and fixed of size 50 mm bore complete all as specified and directed. |
| 67 | M&L in repairs gun metal gate or globe valveswith iron wheel head (ISI Marked), screwed bothends for iron pipe and fixed of size 40 mm bore complete all as specified and directed. |
| 68 | M&L in repairs gun metal gate or globe valveswith iron wheel head (ISI Marked), screwed bothends for iron pipe and fixed of size 25 mm bore all as specified and directed. |
| 69 | S&F in repairs ball float valve complete with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixing of size 40 mm dia complete all as specified and directed.. |
| 70 | S&F in repairs ball float valve complete with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixing of size 25 mm dia complete all as specified and directed.. |
| 71 | Taking out the unserviceable CI pipe lines including all fittings with spigot and socket ends and lead joints including burning out joints and recovering lead of size 80mm bore complete all as specified and directed. |
| 72 | Supply and laying of cast iron pipes with spigot and socketed ends centrifugally cast, class \"LA\" in any length laid in trenches of size 80mm bore complete all as specified and directed. |
| 73 | Taking out the unserviceable CI pipe lines including all fittings with spigot and socket ends and lead joints including burning out joints and recovering lead of size 150 mm bore complete all as specified and directed. |
| 74 | Supply and laying of cast iron pipes with spigot and socketed ends centrifugally cast, class \"A\" in any length laid in trenches of size 150mm bore complete all as specified and directed. |
| 75 | Bends tapers any type, (straight, bend, increasing, decreasing or double socket etc). Tee pieces single branch \"Y\" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs of CI fittings upto 150 bore |
| 76 | M&Lin repairs of run lead joint to CI spigot and socketedpipe of bore 80 mm dia complete all as specified and directed |
| 77 | Dismantling of monoblock pumpset of20 HP capacity including dismantling of all fittings such as sluice valve, NRV, flange joints with gaskets for both incoming and outgoing connections and seal the old 150 mm/80 mm pipes from sump permanently to avoid any water leackage from the sump complete. |
| 78 | Supply and fixNew Monoblock pumppump bronze impeller, copper bounded20 HP , 415 Volts , 50 mtr head with 2900 rmp and 20 Lps discharge complete including incoming cable connection all as per directed. |
| 79 | Supply and laying of cast iron pipes with spigot and socketed ends centrifugally cast, class \"A\" in any length laid in trenches of size 100mm bore complete all as specified and directed. |
| 80 | Supply and laying of cast iron pipes with spigot and socketed ends centrifugally cast, class \"A\" in any length laid in trenches of size 80 mm bore complete all as specified and directed. |
| 81 | Dismantling the power supply of electric motor any type including dismantling from pump and taking to workshop with necessary transportation and opening the complete motor and rewinding the rotor with super enameled copper wire as per the existing gauge with necessary insulation, sticks, varnishing, replacement of connector terminalsincluding replacement of Shaft and shaft bearing, cooling fan, sealing arrangement and springs, replacement of warn out impeller and volute casing, couplers set complete of capacity 20 HPcomplete all as directed. |
| 82 | Supply install and testing 65 mm dia flanged endwater meter in supply line with necessary fittings complete all as specified and directed. |
| 83 | Supply and fix in repair new sluice valve of size 80 mm with cast iron bodywedge stuffing box gland thrust plate hand wheel of grey cast iron spindle of stainless steel nut body seal ring and wedge facing gasket of comprised fibre bolts glands packing of jute and hump flanged drilled type nominal pressure rating PN- 1.0and conforming to IS-780 of 1980 complete all as specified and directed Make : Kirloskar or equivalent |
| 84 | Supply and fixing in replacement of CI foot valve flange type of following size of 100 mm dia in new line complete all as specified. |
| 85 | Material and labour for replacement of un serviceable water pressure gauge of dia 100 mm of the range 0 to 100 Kg /sqcm |
| 86 | M & L for making of core cutting in existing sump at a height equal to pump inlet height and carefully placing new CI pipe line 100 mm dia pipe and inlet and 80 mm dia as out let pipe including all flanged connection and connecting of foot valve of size 100 mm, and interconnection of 80 mm dia pipe line to old outgoing line, including cutting of existing delivey line and making connection of new pipe line. This item includes all flanges and welding work to be incorporaed in connection of pipe lines and valves, lead joint and CI fittings used to be paid under respective schedule of items. |
| 87 | S&F in repairsMS channel thickness 55mmx 55mm x6 mm to work of quality forvalve chamber covers, pump set coupling covers, rackets, base plates for pump sets, supporting channels on culvert and supporting frames for any tank etc complete all as specified and as directed. |
| 88 | S&F in repairsMS sheet thickness 6 mm to work of quality forvalve chamber covers, pump set coupling covers, rackets, base plates for pump sets, supporting channels on culvert and supporting frames for any tank etc complete all as specified and as directed. |
| 89 | Supply and fixing PVC Tank 250 Ltrs complete including making connection of 25 mm dia GI pipe line at inlet and outletto both pump for priming purpose and valve arrangementand float valve connection for overflow complete all as specified and directed. |
| 90 | Material and labour for construction of valve chamber of size 1000 x 1200 x 1200 mm (internal dimensions built in brick masonry on 15 cm thick PCCfoundation (1 : 4 : 8) type D-2 using 40 mm graded stone aggregate over 100 mm thck hard cor with brick work masonary in cement mortar 1:4 using \"B\"class bricks and rendering in cement mortar 1: 4, 10 mm thick internally including exposed surfaces of external surfaces, MS cover made out of 6 mm thick MS sheet on angle iron framework made out of 40 x 40 x 6 mm duly embedded in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate with hold fast made out of MS flat iron 25 x 6 mm x 300 mm long and 40 mm thick PCC coping 40 mm thick 1:2:4 type B-0 using 12.5 mm graded stone aggregate with handle hinges with locking arrangement& applying two coats of synthetic enamel paint over a coat of red oxide primer to all exposed steel surfaces complete all as specified and directed. |
| 91 | M&L for design and fabrication of water level indicator suitable for existing sump in KV complex made of MS base strip 12 inch wide and 5 mm depth and level indicator strip of 2 mm on a channel attached to base strip carefully calibrated for zeo level and full level and indication devided into parts of per 20000 gallons till 50000 gallons with middle marker and the indicator will freely move in a rolleron a channel attached to base plate and last end of indicator will be connected to a floating object touching the water level complete all as directed. |
| 92 | Manual rescue & Operation rescue of water supply installation including sundays and holidays, including electric panel board, operating underground sump control valves etc for 16 hrs daily in two shifts from 0600 hrs to 1400 hrs and 1400 hrs to 2200 hrs in KV staff Qtrs Bhandup by providing one semi skilled operator per shift complete all as specified and directed to operate the following on as required basis.(a) Pumping set monoblock 20 HP - 02 Nos(b) DG set 45 KVA as and when required - 01 NoNote: The operator will attend to minor repairs like replacement of fuses, replacement of filters, oil, tightening of bolts,nuts,arresting leakages etc for which the labour rates are deemed to be included in the quoted rate. (c) Contractor should provide all necessary stationery for records. |
| 93 | Disconnecting the incoming and out going cable connection and dismantling the unserviceable LT outdoor panel.Design fabricating supplying and fixing Outdoor type LTpanel for 02 Nos centrifugal pumpset withincomer, outgoing MCCB, 02 Nos star delta starter mounting, vermin, dust and weather proof totally inclosed cubical type front & backoperated double door separate compartment fabricated out of 3 mm thick CRCA stainless sheet sheet duly treated with seven tank process and painted epoxy powder coated siemens graycolour and with industrial type built in locking arrangement. The meter box shall be factory made froma reputed panel fabricators (CPRI approved manufacturers). The panel shall be floor mounting type and to be fixed with all necessary fixing arrangements such as angle iron brackets and frame or iron angles size 55 mm x 55 mm x 5 mm. The panel to be prewired with suitable size PVC insulated copper conductors busbar with heat shrinkable sleeves of capacity 250 Amps for connecting the incoming MCCB and out going MCCBand including digital type multifunction meter and phase indicator with the following items complete all as specified (Pump house panel). |
| 94 | (a)Copper busbar250 Ampsfor phases and neutralduly sleeved withheat shrinkableinsulation using colour code for R Y B &Nset of 4- 01 Set. |
| 95 | (b)MCCB, 4 Pole, 160 Amps 415 Volts25 KA- 01 No( Incoming) |
| 96 | (b)MCCB, 4 Pole, 63 Amps 415 Volts15 KA- 02 No (Outgoing) |
| 97 | (c)Star delta starer suitable for 3 Phase, 415 Volt, cap of 20 HP-02 Nos Make:- L&T, Havells, Siemens or equivalent. |
| 98 | (d)Indicator lampcompletewithlamp holder LED typesetof03- 01 set (Red, Yellow and Blue) |
| 99 | (e)VAF+ PF meter CL-0.5, input Voltage-50-520 VAC, CT 1A/5 A, Parameter VLL,VLN,A,F& PF digital type meter of size 96mm x 96mm - 01 No |
| 100 | Supply and fixin repairs of MCB TPN 440 Volts 63 Ampbreaking capacity 10 KA rating complete all as specified. |
| 101 | Supply and fixin repairs of MCCB 100 Amps 3 Pole,with breaking capacity 16 KA complete all as specified and directed. |
| 102 | Supply and layin repairs of cable XLPE insulated, armoured heavy duty electric cable, galvanized steel strip or wire armoured, with aluminium conductor electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size35 sqmm x 4 core |
| 103 | Supply and layin repairs of cable XLPE insulated, armoured heavy duty electric cable, galvanized steel strip or wire armoured, with aluminium conductor electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size50 sqmm x 3.5 core. complete all as specified and directed. |
| 104 | Supply and layin repairs of cable XLPE insulated, armoured heavy duty electric cable, galvanized steel strip or wire armoured, with aluminium conductor electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size16 sqmm x 4 core. complete all as specified and directed. |
| 105 | Taking down and Supply and fixing LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.. Make: Philips / Havells / Wipro or equivalent. |
| 106 | Taking down and Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.. Make: Philips / Havells / Wipro or equivalent. |
| 107 | Taking out existing unserviceable FRP terminal box and S&F in repairs mounting type weather proof terminal box of size 150 x 140 x 100 mm heavy duty (machine mould) consisting of 01 No MCB SP 06 Amps and backlite connector of 32 A for single phase and neutral (Three terminals)for cable in cable out entire complete. Terminal box to be fixed to wall all as specified and directed.Make : Sintex/ National or equivalent. |
| 108 | M&L in replacement of Earthing complete with GI earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less than 1.5 M below normal ground level, connected to galvanized iron strip 32 x 4 mmby means of GI bolts nuts, check nuts and washers etcall as shown in electrical plate No. 3 of SSR part 01 1996 including earth work PCC pit with cover, funnel with watering pipe, wire mesh and GI protection pipe light grade all as specified and directed. |
| 109 | Cutting of existing road/PCC for laying of LT cables upto 150 mm depth complete all as specified and directed. |
| 110 | Excavation in trenches not exceeding 1.5M wide and not exceeding 1.5M in depth and getting out in hard/dense soil for laying of cable/pipe complete all as specified and directed. |
| 111 | Returning filling in including spreading, leveling watering and well ramming in layer not exceeding 25 Cms. complete all as specified and directed. |
| 112 | Removal of excavated surplus soil not exceeding 50 m and depositing where directed at al level not exceeding 1.5 m above the starting point. complete all as specified and directed. |
| 113 | PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) in foundation filling & mass concrete complete all as specified and directed.. |
| 114 | PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in coping of poles/ road finishing including use of form work and finishing all exposed faces of concrete as per clause 4.11.66 (a) & (d) of SSR Part-I complete all as specified and directed. |
| 115 | M&L in repairs ofGI pipe 50 mm dia light grade with all fittings for cable protection. complete all as specified and directed. |
| 116 | M & L HDPE DWC pipe 80 mm in trenches for protection of cables. complete all as specied and directed. |
| 117 | Deduct Credit for Demolished/ Dismantled material Rs. (-) 1,06,425.00 (Minus) as listed in Schedule of CreditNote 1:- Tenderers will not quote against this item being a tentative amount to be considered to arrive at the \"Contract Sum\".Note 2:- The tenderer must keep in mind when quoting rates against items out in multiple storey bldg having height beyond 4 mts. Necessary scaffolding and saftey measures required during execution of work are including in this items. |