Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 03-03-2026 | BOQ Corrigendum | BOQ | 14-03-2026 |
| Sl. No. | Item Description |
| 1 | Dismantling of Asbestos cement(corrugated, semi corrugated etc.) sheet in roof coverings complete all as specified and directed. |
| 2 | M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated corrugated steel sheet, any pattern corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering/ wall clading fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed. |
| 3 | M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated plain steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in ridge/ valley/ gutter fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed. |
| 4 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises |
| 5 | M&L for joint free Non Skidjoint free coloured Ceramic tiles 7 to 8 mm thick (square or rectangular),area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tile, laid over and including screed bed or bedding layer of mortar, 15 mm thick, in CM 1:4, complete all as specified and as directed. |
| 6 | M&L for joint free Non Skidjoint free coloured Ceramic tiles 7 to 8 mm thick (square or rectangular),area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tile, laid over and including backing coat or bedding layer of mortar, 15 mm thick, in CM 1:4, complete all as specified and as directed. |
| 7 | M&L for Glazed ceramic tiles on vertical surface of size 450X 350X 7-8mm or 300x200x7-8mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match with shade of the tiles laid over and including 10mm thick rendering as backing coatin CM 1:4 with wire markings to receive tile over it, complete all as specified and as directed. |
| 8 | M&L for joint free Non-skid ceramic colour tiles 7 to 8 mm thick , (square/rectangular), area of each tiles exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of the tiles over and including 15 mm thick screed bed in cement sand mortar 1:4 complete all as specified and as directed. |
| 9 | M&L 18-20mm thick black Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in over and including20mm thick cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including necessary dismantling of existing unserviceable one complete all as specified and as directed. |
| 10 | S & F in repairs vitreous china wash down water closet (pedestal pattern), white including thermoplastic seats and covers of grade 2 type, recessed with hinging device of bronze or brass with nickel chromium plating, fixing bolt, connector to flush pipe and making connections to flush pipe, connector to branch soil pipe and anti syphonage pipes etc. including sealing the joints and making leak proof using sealant complete all as specified and as directed. |
| 11 | S&F in repair vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests etc (excluding cistern and flush pipe) including S or P trap and provision of cement concrete M-5 type E-2(using 40mm graded crushed stone aggregates) complete all as specified and as directed. |
| 12 | S & F in repairs in repairs 10 litres capacity, low level, syphonic type, white, pressed steel (vitreous enamelling) flushing cistern as per IS 774: 2004 with inlet, ball valve, float and handle including brackets and 40 mm nominal dia high density polyethylene pipes for flush pipe complete all as specified and as directed. |
| 13 | M&L for Windows of double Rebate openable windows made of Pre painted steeel (Base steel as er IS 513 of 0.58mm thick \"D\" quality Galvanised as per IS 277 with Zink of 120 GSM). Primer coated with epoxy primer of 5-7 microns thick, finish painted with a polyester paint 12-16 microns thick and back coated with 5-7 microns thick alkyd backer. Section for outer frame should be of 72x55mm centre mullion should be of 72x50mm, section for fixed glass beading should be of 12x12mm and section for shutter should be of 52x25mm outer frame & mullion sections to have rebate for glazed shutters, fly mesh and 20mm provision for guard bars/grills fly mesh shutters section should be of 20x40mm. The sections are to be cut to length mitre joined with corner bracket centre mullions to be fixed with mullion cap. Stay, handle 2 nos of heavy duty stainless steel pivot hinges shall be provided per shutter. The should be panneled with 4mm thick plain float glass and SS mesh for fly mesh shutters (304 Grade), Rubber Gaskets are provided all around the glass. The above frame should be fixed to the concrete/masonry wall by means of self expanding screws, including 10mm sqaure bars with 6\" (152.4mm) pitch complete all as specified and directed (Note: measuremnt should Taken from frame L x B of window.) |
| 14 | Supplying and fixing of fixed Louvered Ventilators made of pre-painted steel (base steel as per IS 513 of 0.58 mm thick \"D\" quality, galvanized as per IS 277 with zinc of 120 GSM) primer coated with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with 5-7 microns thick alkyd backer. Thesection for louvered ventilators should be 33 x 56 mm box section panelled with 4 mm pinhead glass with Ethyl propylene Diamine monomer Gasked (EPDM) and the sections cut to length mitre joined with corner bracket. Corner brackets made of CRCA with Zinc Phosphate. The frames to be fixed to the concerete/masonry wall by means of self expanding screws including 10 mm square guard bars with 6\" pitch complete for finished item of work all as specified and directed. |
| 15 | S & F hot rolled medium and high tensile structural steel of grade E165 as per IS 15911: 2010 as in framed work such as grills, grating, etc., with ends of bars of shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework water tanks and similar work complete all as specified and directed by Engineer-in-charge. |
| 16 | Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and as directed. |
| 17 | Supply & fix sheet glass, ordinary quality, 3 mm thick and glazed with oil putty or fixed with beads in square not exceeding 0.5 Sqm in each pane complete all as specified and directed. |
| 18 | S & F 4 mm thick figured glass, pin head type and glazing with oil putty or fixed with beads in square not exceeding 0.5 sqm in each pane complete all as specified and as directed. |
| 19 | S & F vitreous china counter type wash hand basin, ovel shape size 550 mm x 400 mm including brackets including32 mm PVC waste coupling suitable for wash hand basin with long screwed shanks and fly nuts andPVC waste pipe 32mm bore complete all as specified and as directed. |
| 20 | S & F in repairs 15 mm nominal size, nonrising spindle type fancy concealed stop valves as per IS 8931: 1993 made of cast brass including Knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed |
| 21 | S&F in repair bib taps with wall flange, fancy type, quarter / half turn, chromium plated, long body with capstan head and cup, screwed down, screwed for iron pipe or for brass ferrule including accessories, suitable for bore of pipe 15 mm, complete all as specified and as directed. |
| 22 | S & F in repairs brass chromium plated shower rose 125 mm size with or without swivel joints, any size, fancy type including fixing to steel pipe or union complete all as specified and as directed. |
| 23 | S&F in repair stainless steel grating doom 125mm dia complete all as specified and directed. |
| 24 | S & F in repairs brass chromium plated tubular towel rail, 20 mm dia, D type, 60 cm long between flanges complete all as specified and as directed. |
| 25 | S & F in repairs 5 mm thick bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed. |
| 26 | S & F pillar taps, fancy type, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered \"hot\" or \"Cold\" with long screwed shanks and flynuts screwed for iron pipe and fixed complete all as specified and directed. |
| 27 | S & F in repairs sinks with drainage board made of stainless steel 1 mm thick sheet kitchen or laboratory with plugs, washers and 40 mm nominal size, copper alloy, nickel chromium plated finish waste fittings with including silicone sealant; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipes overall size 915 mm X 460 mm bowel size 410 mm X 330 mm X 160 mm complete all as specified and as directed. |
| 28 | S & F in repairs 15 mm nominal size, nonrising spindle type fancy stop valves/ angle valve as per IS 8931: 1993 made of cast brass including Knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed. |
| 29 | S&F in repair health faucet with 1m long flexible CP pipe with wall hook complete with all fittings complete all as specified and directed. |
| 30 | Taking down cement plaster, any description, on brick or stone walls, etc.including racking out joints, hacking for key, scrubbing down with water, etc. including removal of rubbish material away from site, complete all as specified and as directed. |
| 31 | Material and labour for plastering 5 mm thick on fair faces of brick work or concrete surfaces as in ceiling in cement mortar 1:3 finished even and smooth without using extra cement complete all as specified and as directed. |
| 32 | Material and labour for plastering 10 mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:6 finished even and fair without using extra cement complete all as specified and as directed. |
| 33 | Material and labour for plastering 15 mm thick (in two layers of 10mm and 5mm thk) on fair faces of brick wall or concrete surfacesin cement mortar 1:4 with water proofing compound as per manufacturer\"s printed instruction finished even and fair complete all as specified and directed.Note: Water proofing compound shall be measured and paid for separately. |
| 34 | Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar, suitable for 75 / 110 mm Internal dia of pipe complete, all as specified and as directed by Engineer-in-charge at site. |
| 35 | S&F PVC (SWR) Pipes single socketed in any length with rubber ring joints, 110 mm bore fixed to walls/floor, complete all as specified and as directed. |
| 36 | S & F of PVC bends without inspection door (any angle), 110 mm dia conforming to IS 14735: 1999 complete all as specified and directed. |
| 37 | S&F PVC(SWR) pipes 75mm dia single socketed in any length with rubber ring joints fixed to walls/floor complete including clamps for securing pipe, complete all as specified and as directed. |
| 38 | S & F of PVC bends without inspection door (any angle), 75 mm dia conforming to IS 14735: 1999 complete all as specified and directed. |
| 39 | S & F in repair PVC SWR Tee(87.5⁰) single, 75 mm dia without inspection door conforming to IS 14735: 1999 complete all as specified and directed. |
| 40 | Taking up or down 15 mm bore of steel tubing and connections, including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified. |
| 41 | Supplying & laying in trenches 15 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed. |
| 42 | Taking up or down 20 mm bore of steel tubing and connections, including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified. |
| 43 | Supplying & laying in trenches 20 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed. |
| 44 | S&F in repair rotational moulded polyethylene water storage tank 1000 litre capacity of triple layered layer wall construction (Cylindrical, vertical with closed top) hoisted and fixed in position including 20 mm dia ball brass valves, high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule all as specified and as directed. |
| 45 | S&F in repair rotational moulded polyethylene water storage tank 500 litre capacity of triple layered layer wall construction (Cylindrical, vertical with closed top) hoisted and fixed in position including 20 mm dia ball brass valves, high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule all as specified and as directed |
| 46 | Complete removal of existing treatment of wall and applying two coats of oil bound distemper over one coat of alkali resistant primer over 3 mm thick wall care putty to match the surfaces complete all as specified and as directed |
| 47 | M & L for preparation of new plastered surface of wall and applying two coats of oil bound distemper over one coat of alkali resistant primer over 3mm thk putty to match the existing surfaces complete all as specified and as directed |
| 48 | M&L for preparing newly plastered surfaces of ceiling andapplying three coats of whitewash complete all as specified and as directed. |
| 49 | Preparation of old decorated surfaces on ceilings and applying one coat of white wash complete all as specified and as directed. |
| 50 | Material & Labour for preparation of new plastered surfaces and applying two coats of exterior emulsion weather resistant/weather shield paint with primer on over & including a coat of 1mm thick putty concrete/plaster surfaces including preparation of plastered (as in external surfaces of wall) complete all as specified and directed. |
| 51 | M&L for complete removal of existing treatment of wall and applying two coats of exterior emulsion weather resistant/ weather shield paint with a coat of suitable primer over concrete or plastered surfaces after preparation of surfaces including coat of putty of suitable thickness to make the surfaces smooth complete all as specified and directed. |
| 52 | Taking down old defective chowkhats with shutter (without taking off shutters from the frame) n.exc 1.5 sq.m eachand removing away from site, complete all as specified and as directed. |
| 53 | Taking down wooden chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 sqm but not exceeding 4.00 sqm each complete all as specified and as directed |
| 54 | S & F prelaminated particle board (decorative lamination on one side and other side balancing lamination), 20 mm thick, grade I or II & type II (Designation PLB-12 or PLB-22), made out of medium density particle board (flat pressed-three layer or multilayer and graded (grade I or grade II), bonded with BWR adhesive), fixed with screws to timber/ steel frame work for horizontal applications as in table tops, counter, furniture tops, etc. complete all as specified and as directed. |
| 55 | Dismantling wooden boarding, any description, fixed in any position with nails complete all as specified and as directed. |
| 56 | M & L for powder coated (colour) aluminium frame for doors, windows, ventilators (thickness of powder coating not less than 50 micron) with one or more rebates including joining cleat for fixing including handle, tower bolt, door stopper, grills etc. complete all as specified and as directed. Note:- Design/ pattern, profile sizes and other dimensions shall be of standard size and as directed. |
| 57 | S & F mild steel continuous hinge, 30 mm nominal size, 1 mm thick, type IV as per IS 3818: 1992, bright finish and fixed to cupboard shutter complete all as specified and directed. |
| 58 | S&F pressed steel frames for doors of size 125mm x 60mmwith one or more rebates, including necessary fixing lugs, hinges, lock strike plate, complete all as specified and as directed by Engineer-in-charge at site.NOTE:- Filling hollow of frame with plain cement concrete and/orwith cement mortar shall be measured and paid separately. |
| 59 | S&F pressed steel frames for doors of size 105mm x 60mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, complete all as specified and as directed.NOTE:- Filling hollow of frame with plain cement concrete and/orwith cement mortar shall be measured and paid separately. |
| 60 | S&F 35 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides with and including 5mm thick teakwood lipping all round, complete all as specified and as directed. |
| 61 | Supply and fixing 2nd class HW 35mm thickGlazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. divided into squares(without sash bars ), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats as specified in SSR Part-I section 8 Clause 8.24 (a) complete all as specified and as directed. |
| 62 | Supply and fixing of solid PVC door frames of size 50 mm x 47 mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube all as per specification & drawing complete all as specified and directed. |
| 63 | S&F of Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC \"C\" channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rails on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and jointed together with solvent cement, supplying & fixing in the frame at site as per specification & drawing, complete all as specified and as directed. |
| 64 | S & F aluminium barrel tower bolts with barrel and bolt of extruded sections of aluminium alloys, 150 mm long, anodized finish not be less than Grade AC 10 of IS 1868 : 1996 with transparent anodic film complete all as specified and as directed. |
| 65 | S & F aluminium alloy sliding door bolts with hasp, staple and fixing clips of sheets, or extruded sections and fixing bolts and sliding bolts of extruded sections of aluminium alloy, 300 mm long, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed. |
| 66 | S & F 100 mm medium weight mild steel butt hinges made out of cold reduced low carbon steel or hot rolled carbon steel as per IS 1341: 1992 complete all as specified and as directed. |
| 67 | S & F cast aluminium alloy handle, cast type, 150 mm size, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed. |
| 68 | S & F cast aluminium alloy handle, cast type, 100 mm size, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed. |
| 69 | M & L for preparation of new or previously untreated wood or wooden surfaces, of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed. |
| 70 | S & F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and as directed. |
| 71 | Preparation of newly or previously untreated steel surface of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed. |
| 72 | Dismantling of wrought or mild steel work of any description such as in ladder work, bracing/supporting angle iron, roof top MS sheets, railings etc. complete all as specified and directed. |
| 73 | S & F hot rolled medium and high tensile structural steel of grade E 250 quality A conforming to IS 2062: 2011 as in joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20 mm of the length indicated) complete all as specified and as directed. |
| 74 | S&F suspended false ceiling using E-gnd 2430 180 GSM (exposed ceiling suspension system) of gridsize 600 mm x 600 mm with main runner 34 mm x 24 mm and wall angle 32 mm x 24 mm using 4 mm thick Hihg pressure steam crude Non asbestos fiber cement plain board (E board classic) in & including a grid of GI system duly suspended with 4mm dia GI wire hanger fixed with steel dash fasteners or iron purlin form the roof with adjustment clip providing positions for light fixture air conditioning diffuser and ducts sprinkler smoke cetectores etc. the main runners to be secured to structura soffts by hanger @ 1220 mm maximum centre to centre the last hanger at the end of each main runner should not be placed at more than 450 mm from the adjucent wall flush fitting 1220 mm cross tee to be inter locked between main runners @ 610 mm centre to centre so as to form 600 mm x 600 mm grid complete all as specified and as directed. |
| 75 | S & F stainless steel curtain rod made out of stainless steel sheet of grade X02Cr19NilO (304 S2), surface finish No. 4 as per IS 6911: 1992, 25 mm dia including fixing to brackets and holders etc. complete all as specified and as directed. |
| 76 | M & L 75 mm thick plain cement concrete M10(Nominal Mix) using 40 mm nominal size graded stone aggregates finished surface even and fair as in plinth protection and making 50mm deep joints at every 3 mtr enterval and at every corners and filling the joints with bitumen grade 85/25 and sand mixture 1:3 complete all as specified and as directed. |
| 77 | M&L polished chequered cement concrete tiles 30cm x 30cm x 25mm thick, set, jointed and pointed ineat cement slurry in floors with grey pigments cement and pigments and including 15 mm thick screed bed in cement sand mortar 1:4 complete all as specified and as directed. |
| 78 | M & L for machine cut Kota stone slab flooring 20 to 25 mm thick over cement screed bed of 20 mm thick in cement mortar 1:3, laid and jointed with grey cement slurry, mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed. |
| 79 | M & L for 20 to 25 mm thick machine cut Kota stone in risers of steps, skirting, dado and pillar laid on backing layer of 10 mm thick in cement mortar 1:3, laid and jointed, pointed with grey cement slurry, mixed with pigments to match the sheds including rubbing and polishing complete all as specified and directed. |
| 80 | Demolition of cement concrete(unreinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level) and complete all as specified and as directed. |
| 81 | M & L for cement concrete in foundation, filling and mass concrete in M5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed. |
| 82 | Supply and fix in repairs PVC SWR Nahani/ Floor trap plain with grating including jointing with solvent cement, dia of outlet 75 mm, water seal minimum 50 mm, complete all as specified and directed. |
| 83 | S & F stainless steel soap dish weight not less than 150 gm each fixed to plugs with chromium plated brass screws complete all as specified and as directed. |
| 84 | M & L for cement concrete M10 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs, slab staging for water tanks, filling of pressed steel door frame, fixing of hold fasts and the like including weathering, slightly rounded or chamfered angles and throating including necessary formworks complete all as specified and directed. |
| 85 | Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) in any position below or above ground floors, not exceeding 15 cm in depth complete all as specified and as directed. |
| 86 | M & L for RCC M20 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in chajjas complete all as specified and as directed. |
| 87 | M & L for RCC M20 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed. |
| 88 | M & L for mild steel TMT bars 6 mm to 8 mm dia, cut to length, bent to shape required, including hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips and including welding has to be done with minimum 20 cm over lap for new and old of any height. Complete all as specified and as directed. |
| 89 | M & L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizontal or sloping) for rough finished flat surfaces of concrete complete all as specified and as directed. |
| 90 | Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. complete all as specified and directed. |
| 91 | M & L for brick work with sub class \"B\" bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6 complete all as specified and as directed. |
| 92 | M & L for brick work with sub class \"B\" bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and as directed. |
| 93 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed. |
| 94 | Taking down ceiling fan 1200/1400 mm sweep / exhaust fans including disconnection of electric connection, dismantling blades and removing fan and blades to store complete all as specified and as directed. |
| 95 | M & L for point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC concealed conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories/ fittings ISI marked including sunk cast pressed steel terminal box made out of MS sheet 1.25mm thick for mounting of modular fittings, switches, sockets, regulators etc suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed.Note:- On RCC roof ceiling PVC conduit shall be provided on surface with proper fixing clips. |
| 96 | M & L for point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on the same board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC concealed conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed.Note:- On RCC roof ceiling PVC conduit shall be provided on surface with proper fixing clips. |
| 97 | M & L for point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC concealed conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. Note:- On RCC roof ceiling PVC conduit shall be provided on surface with proper fixing clips. |
| 98 | M & L for point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC concealed conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. Note:- On RCC roof ceiling PVC conduit shall be provided on surface with proper fixing clips. |
| 99 | M&L for switch piano (flush button type) single pole one way 5 Amps complete all as specified and directed. |
| 100 | S & F (3 pin and 2 pin) combined socket outlets, 6A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B complete all as specified and as directed. |
| 101 | S & F switch socket combination with (3 pin and 2 pin) combined socket outlets, 6A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B and switch, 6 A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed. |
| 102 | S & F switch socket combination with (3 pin and 3 pin) having two earthing pins, combined socket outlets, 6A & 16A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B and switch, 16 A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed. |
| 103 | S & F ceiling roses, 6A, 240 V, surface type, intended to support mechanical loads by means of flexible cord, having provision for the connection of switch wiring, screw type terminal, made out of Polyamide or hornbean complete all as specified and as directed. |
| 104 | S & F Bayonet plastic lamp holder, 2 A, 250 V, ordinary, backplate, non-switched, unenclosed, without T marking, B22d complete all as specified and as directed. |
| 105 | S & F LED light fittings consisting separate batten and tube lights, including both batten and tube lights, 1 X 20 W, 220 V, AC, decorative box type, epoxy powder coated white extruded aluminium channel housing, lumen output of minimum 2000, integral electronic driver (SMPS based constant current output) with output short circuit protection, over voltage protection, surge voltage protection upto 2 kVs, protection grade IP20, CRI greater than 80%, THD less than 10%, power factor of minimum 0.95, life span of minimum 50000 working hours including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 106 | S&F LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. |
| 107 | S & FLED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 108 | Supply and fixing in repairLED building security light of capacity 60 Watt made up of pressure die cast aluminium housing withhigh power LED as light source and lens embedded PC cover including electronic driver should have luminaire efficacy ≥110 lumens/watt,CRI>70 ,PF > 0.95,CCT=5700±300,IP66,impact resistance IK 07 ,inbuiltprotection against lightning, over voltage, short circuit and surge/spike protection upto 10kV including connection with PVC insulated, PVC sheathed, multistranded copper conductor cable of size 1.5 sqmmX 3 core complete all as specified and directed. |
| 109 | Supply and fixing in repairs street light bracket made of GI pipe 40 mm bore light grade (bend to shape), 2 metre longand fixed with Ms flat iron clamp(clamp shall be 40 X 5mm), nuts, bolts and washers on pole complete all as specified and directed. |
| 110 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1400 mm sweep. Min air delivery 245 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) fixing arrangement complete including 3 runs of 1.50sqmm FRLSH cable from ceiling rose to fan and fan hook complete as specified and directed. |
| 111 | S & F MCCB Distribution board of sheet metal enclosure double door, CPRI approved, vertical type, triple pole and neutral, 4 way with 250 Amps rated bus bar, 415 volt, IP43 protection grade and fixed with MS hold fast and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate, including taking down old unsrv DB, complete all as specified and as directed. |
| 112 | S & F in repair double door MCB Distribution board of sheet metal enclosure, single pole and neutral, 8 way with 200 Amps rated bus bar, 240 volt, IP43 protection grade and fixed with PVC plug and screws and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed. |
| 113 | S & F in repair MCCB, Fixed Thermal & Fixed Magnetic setting, 4 pole, 415 volts, 16 kA, 100 Amp complete all as specified and as directed. |
| 114 | S & F circuit breakers (MCB), single pole (SP), unenclosed, panel board type, screw type terminals for external copper conductors, B-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 40 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed. |
| 115 | S & F in repair of circuit breakers (MCB), single pole (SP), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 6A to 32 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed. |
| 116 | S&F in repair of MCB, SPN, 240 volts, C Curve, 32 Amps 10 KA complete all as specified and directed. |
| 117 | M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 4.0 mm dia galvanised mild steel wire by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 15 mm dia GI pipe light grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed. |
| 118 | Supply and fix sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 6 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 6 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly including taking down old sub main wiring complete all as specified and directed. Note - (i) Two runs of 6 sqmm cable, one run of 6 sqmm cable and one run of conduit shall be measured and paid as one unit length. |
| 119 | Supply and fixing of concealed sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 4 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 4 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly including taking down old sub main wiring complete all as specified and directed. Note - (i)Two runs of 4 sqmm cable, one run of 4 sqmm cableand one run of conduit shall be measured and paid as one unit length. |
| 120 | Supply and fix sub main wiring complete with and including four Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 6 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 6 sqmm two Nos single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly complete all as specified and directed. No:- Four runs of 6 sqmm cable, two run of 6 sqmm cable and one run of conduit shall be measured and paid as one unit length. |
| 121 | Supply and fix sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC concealed conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 1.5 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly including taking down old sub main wiring complete all as specified and directed. Note (i) Two runs of 1.5 sqmm cable, one run of 1.5 sqmm cable and one run of conduit shall be measured and paid as one unit length. |
| 122 | S & F sheet metal enclosure with socket plug top and MCB TPN enclosure with three pin & earth plug and socket complete with MCB TPN 20 Amps 415 volts complete all as specified and as directed. |
| 123 | S & F of sheet metal enclosure with socket plug top and MCB single pole and neutral enclosure with two pin & earth plug and socket complete with MCB SPN 20 Amps 240 volts complete all as specified and as directed. |
| 124 | S & F exhaust fan, AC, 50 Hz, single phase, 230 V, 300 mm sweep, 1400 RPM 4 pole, heavy duty, metal body, 4 Nos blades, Insulation Class A, ISI marked including capacitor to ensure power factor more than 0.9 including louvers complete all as specified and as directed. |
| 125 | S & F exhaust fan, AC, 50 Hz, single phase, 230 V, 450 mm sweep, 1400RPM, 4 pole, heavy duty, metal body, 4 Nos blades, Insulation Class A, ISI marked including capacitor to ensure power factor more than 0.9 including louvers complete all as specified and as directed. |
| 126 | M& L for cutting of circular hole at any type of wall oof suitable size for fixing of exhaust fan of any sweep, fixing of 450x450x6mm thick BWR grade plywood and making hole and fixing of stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mmand making good the surfaces to match with existing surfaces complete all as specified and as directed. |
| 127 | Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3 core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 50 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. including taking down old cable complete all as specified and as directed. |
| 128 | Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3 core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 35 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. including taking down old complete all as specified and as directed. |
| 129 | Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or water supply pipes lines etc or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed. |
| 130 | Supply & laying Sand coarse dry as in cushioning of underground electric cable in trenches, laid to a uniform thickness of 23cm (15cm under the cable & 8cm over the cable) and gently punned down to 18cm thickness complete all as specified and as directed. Note :- Only punned down sand shall be measured. |
| 131 | M&L for bricks, common burnt clay building bricks, sub- class \"B\" designation 75 complete all as specified and directed. |
| 132 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed. |
| 133 | Removing excavated material (excluding hard rock) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 134 | Supplying & laying, in trenches 40 mm nominal bore, light grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 including taking down old complete all as specified and as directed. |
| 135 | Supplying & fixing to walls and ceilings or laid in floors 25 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011complete all as specified and as directed. |
| 136 | S & F 25 mm gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed to pipe including taking down old complete all as specified and directed. |
| 137 | Cutting galvanised mild steel pipe of nominal bore 40 mm or 50 mm for alterations or additions (each cut measured) complete all as specified and as directed. |
| 138 | Taking up or down steel tubing and connections, bore of pipes 25 mm and removing away from site, complete all as specified and as directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy