| 1 | Dismantling of floor hearth or wall tiling including cement mortar bedding but not backing and rubbish off the primises complete all as specified and directed. |
| 2 | M&L for Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 15mm thick in CM 1:4 screed bed complete all as specified and directed. |
| 3 | M & L for non skid ceramic (colored),7 to 8 mm thick as in floor area of each tile exceeding 0.6 Sqm but n exceeding 0 .11 Sqm , set and jointed in neat cement slurry and pointed in white or colored cement to matchincl and over screed bed or beeding layers of mortar 15mm thick in CM 1:4 in floors, complete all as specified and directed. |
| 4 | Dismantling of water tanks and removing to store having Capacity of Exc 500 litres and n.exc 1000 litres complete all as specified and directed. |
| 5 | S & F for 1000 ltrs capacity rotational moulded polyethelene water storage tanks(cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed. |
| 6 | S & F in repairs 25 mm bore ball brass valves,high pressure,with polythene float and flunut complete,screwed for iron pipe or brass ferrule and fixed complete all as specified and directed. |
| 7 | Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 8 | S & F of mild steel Fe 410-W (Grade-Fe 250) quality A of Compound girders and stanchions,purlin ,rafter, lattice girders, aerial masts, , staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc complete all as specified and directed. |
| 9 | M & L for preparation of new or previously untreated(old) steel surfacesand applying two coats of synthetic enamel paint over and including a coat of red oxide primer complete all as specified and directed. |
| 10 | M & L for Preparation of old painted steel surfaces of any description not otherwise described over 10cm width or girth and applying two coat of synthetic enamel paint complete all as specified and directed. |
| 11 | Taking down of chowkhats / frames n exc 1.50 sqm each without taking off shutter eachcomplete all as specified and directed. |
| 12 | Taking down of chowkhats / frames exc 1.50 Sqm but n exc 4.0 sqm each without taking off shutter eachcomplete all as specified and directed. |
| 13 | M&L pressed steel frames of size 165x60 mm for door with one or more rebates incl necessary fittings, lugs, hinges, lock strike plate, flat iron hold fast etc complete as specified & as directed. |
| 14 | M&L Pressed steel frames for doors of size 105x 60 mm for doorwith one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified,and as directed. |
| 15 | S & F 30mm thick flush door shutter solid core construction with block board core and laminated0verplywood faceDecorated typeon both side completeall as specified and directed. |
| 16 | M&L for preparation of new wooden surface of any description n. exc. 10cm width or girth and applying two coats of synthetic enamel paint over and includinga coat of primer complete all as specified and directed. |
| 17 | Supply and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter 30 mm of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately). |
| 18 | Supply and fixing 18mm thick factory made single extruded WPC (Wood Polymer Composite) solid board one side white colour and other side of board laminated with PVC foil of minimum 14 micron thickness of approved design pasted with hot melt adhesive for cup boards. work stations and bathroom/kitchen cabinet etc. of required sizes comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel piano hinges/soft close clip on concealed hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel piano hinges/soft close clip on concealed hinges and necessary S.S screws shall be paid separately) |
| 19 | S&F factory made35 mm thick2nd class hardwood glazed and skeleton shutters, open rebated and prepared to receive glass, gauge, etc., divided into squares, with plain, chamfered or rounded, mitred and rebated sash members, any numbers and mited beads for securing glass, etc sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.20(a) supplied and fitted to chowkatscomplete all as specified and directed. |
| 20 | S & F stainless steel wire cloth 0.36 nominal dia wire & average width of aperature 1.40 mm fixed with stainless steel wire staples complete all as specified and directed. |
| 21 | S & F of aluminium anodised 200 mm barrel tower bolts of extruded section complete all as specified and directed. |
| 22 | S & F of aluminium handle 150 mm cast type anodised complete all as specified and directed. |
| 23 | S & F of 100 mm butt hinges extruded aluminium alloy with galvanized mild steel hinges pin anodised type \"C\"-22 complete all as specified and directed. |
| 24 | S & F of floor door stopper of aluminium alloy body and tongue, anodised , with hard drawn steel spring overall length of cover plate 140 mm, complete all as specified and directed. |
| 25 | S & F 300 mm aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium complete all as specified and directed. |
| 26 | Taking up or down steel tubing / CPVC Pipes and connection including cleaning for refixing or removed to store, complete all as specified and directed. |
| 27 | (a) 20 mm bore |
| 28 | (b) 25 mm bore |
| 29 | Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified & directed of following sizes :- |
| 30 | (a) 20 mm bore |
| 31 | (b) 25 mm bore |
| 32 | S&F in repair soap dish of jaquar make catalog no. AQN-CHR-7731or equivalent complete all as specified and directed. |
| 33 | S&Fin repair single towel rail of 600mm long of jaquar make catalog no.AHS-CHR1581or equivalent complete all as specified and directed. |
| 34 | Supply & fixin repair glassshelvetype, Make : Jaquar cat :AQN-CHR-7771 complete all as specified and directed. |
| 35 | S & F Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe)complete in all respect complete all as specified and directed. |
| 36 | S&Fin repairover head shower with shower arm140mm dia . Round shape single flow with air effect shower. ( ABS Body & Face Plate Chrome Plated) of jaquar CAT OHS-CHS-1757and equivalent complete all as specified and directed. |
| 37 | S & F in repairs 10 litre capacity PVC low level flushing cisternwith all accessories complete fixed with WC including syphone pipe, PVC flushing pipe of size complete all as specified and directed. |
| 38 | M&L for 18-20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite and including 15 mm thick screed in CM 1:3 complete all as specified and directed. |
| 39 | S&F in repairs pillar cocks 15mm bore CP with 140 mm extension bodyand fixed. Jaquarcat partno: ARI-CHR--39021 or equivalent complete all as specified and directed. |
| 40 | S & F in repairs grating round 150mm size of PTMT (minimum 100 gms) with waste hole of PTMT complete all as specified and directed. |
| 41 | S&F in repairsvitreous chinacounter TOPwash basin, white, of size 425X425X145 mm excluding taps, brass coupling 32mm, bottle trap of 32mm size with 300mm long .catalog no ONS-WHT-10901 complete all as specified and directed. |
| 42 | S&F in repairs PVC connection 15mm size PTMT nuts of length 450 mm complete all as specified and directed. |
| 43 | S&F in repairs fancy type Bib taps 15mm bore CP with wall flange, screwed down, screwed for iron pipe or for brass ferrule and fixed. Jaquarcat partno: QQT-7037 or equivalent complete all as specified and directed. |
| 44 | S & F as in repair 15 mm bore fancy type angular valve cast copper alloy screwed down, high pressure, with crutch or butter fly handle, screwed both ends for iron pipe or for unions complete all as specified and directed. |
| 45 | S & F in repairs 20 mm bore dia gun-metal,globe or gate valves,with iron wheel head,screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 46 | Demolition and breaking up drain pipes upto 100/110 mm dia (Salt glazed ware, AC, PVC or reinforced concrete) set in cement mortar complete all as specified and directed. |
| 47 | Demolition and breaking up drain pipes upto 75 mm dia (Salt glazed ware, AC, PVC or reinforced concrete) set in cement mortar complete all as specified and directed. |
| 48 | Supply and fixing of 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to wall with suitable clamp complete all as specified and as directed. |
| 49 | Supply and fixing of 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to wall with suitable clamp complete all as specified and as directed. |
| 50 | Supply and fixing of PVC (SWR) junction single, (single T) equal or unequal provided with access door suitable for 110mm bore PVC pipes complete all as specified and as directed. |
| 51 | Supply and fixing of PVC (SWR) bends any radius suitable for 110mm bore PVC pipes with access door complete all as specified and as directed. |
| 52 | Supply and fixing of PVC (SWR) bends any radius suitable for 75mm bore PVC pipes with access door complete all as specified and as directed. |
| 53 | Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings of any height complete all as specified and directed. |
| 54 | S&F pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of colour as approved by GE and having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 55 | S&F pre- painted galvalume aluminum zinc coating GI based plainsteel sheet 0.50mm thick of colour as approvedand having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screwscomplete all as specified and directed. |
| 56 | Demolition of ceiling boards/wall (puf) of any description, and any thickness including cover fillets and frame work complete all as specified and directed. |
| 57 | M & L for Anodised aluminium snap grid having Size of grid 605 x 605mm frame work for false ceiling all as specified complete all as specified and directed. |
| 58 | S & F of 9mm thick PVC laminated gypsum ceiling tiles size of 600mm x 600mm, square edge, front side laminated PVC and back side aluminium foil complete all as specified and directed. (Frame work for ceiling shall be measured and paid separately). |
| 59 | S & F powder coated anodised Aluminium alloy sections sliding windows with frames Series-B (18 mm) and , 3 track sliding shutters/openable duly fitted with neoprene beading, glazing clips, two shutters tinted glass panes 4.80 mm nominal thickness one shutter with stainless steel wire cloth 0.36mm dia and average width of aperture 1.4mm , aluminium alloy handles etc.complete all as specified and directed.Note :Rates include all glazing/aluminium wire cloth, rubber packing, joining, cleats, glazing clips, aluminium snap beading, locking arrangements, handle with or without opeing for AC as directed by EICetc |
| 60 | S & Faluminium anodisedventilator with fixed aluminium frame of size 65 x 40 x 1.98mm thick fixed in vertical position with aluminium vertical members andhalf portion to be provided with 4mm thick pin head glass and remaining portion to be louvered using 4mm thick pin head glass including necessary channel frame work, including rubber gasket and frame with wire mesh of aluminium,and deco grill ,aluminiumbeading complete all as specified and as directed. |
| 61 | Demolition ofBrick work or stone/boulder masonry, build in cementmortar or cement lime mortar including all quions, arches, pillars etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. |
| 62 | M&L for brick work with sub class \"B\" bricks straight or curved on plan exc 6 mtr mean radius built in CM 1:6 complete all as specified and directed. |
| 63 | Taking down cement plaster on wall of any description including racking out joints, hacking for key and scrubbing down with water etc complete all as specified and directed. |
| 64 | M&L for rendering on fair faces of brick work in two layers i.e., 15 mm thick inCM 1:4 mixedfinishing the surface fair and even without using extra cement complete all as specified and as directed. |
| 65 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over New surfaces complete all as specified and directed. |
| 66 | Demolition of cement concrete of any description and in any position (unreinforced) in ground floors/ paving not exceeding 15 cm thick (below or above GL) and disposing off rubbish off the premises of cantonment complete all as specified and directed. |
| 67 | M&L 75mm thick PCC (1:3:6) type C2 as in plinth protection/footpath using 40mm graded stone aggregate finishing cement concrete surface even & smooth without using extra cement including impression and glass strip or bitumen filling in two panel etc complete all as specified and as directed. |
| 68 | Supply & Fix in repairs bevelled edge mirror of size 600 x 450mm and any thickness, mounted in 6mm thick plywood/AC building board with PVC coloured frame all around, complete all as specified and as directed. |
| 69 | S & F poly urethane foam (PUF) pannel to thickness 50mm/60mm, density of pannel 40 Kg/m3 skin pre painted powder cotted PPGI/PCGI tongue and groove as per ASTM D 1692 sandwich between as per site require complete all as specified and directed. |
| 70 | Dismantaling and taking down copper / aluminium point wiringany type / size complete with removing all connection and accessories such asswitches , sockets, ceiling rose,pendent holder,fan regulator any type , all type of fitting , batten , steel or PVC conduit , casing caping etc compele and making good the disturbed surface complete all as specified and directed. |
| 71 | Taking down old and unsrevicablesheet metal enclosure , switch fuse unit , distribution bord any type /way / capacity including fuses,MCB\"s , insulator etc complete after removing all connection and making good the disturbed surface all as directed. |
| 72 | M & L for Point wiring for one light/fan point controlled by one modular switch, one way, 1 module byusing 1.5 Sq mm nominal cross sectional area multistrandedcopperconductor, PVC insulated unsheathed FRLS cables in and including PVC casing & capping with all accessories/fittings, modular metal flush box, modular white cover plate with frame fitted with screws, washers and 1.5 Sq mm nominal cross sectional area multistranded copper conductor green PVC insulated unsheathed earth wire and connecting to earth dolly and make wall/panel surface as existing same colourand making good disturbed surfaces of walls, panels, floors, etc. to match with the existing good surfaces of walls, panels, floors etc. complete all as specified and as directed. |
| 73 | (a)One light point controlled by one way one switch SP 5 Amps ,240 V. |
| 74 | (b)One ceiling/exhaust fan point controlled by one way one switch SP 5 Amps, 240 V |
| 75 | (c)One switch socket outlet 3 Pin, 6 Amps, SP on independent board. |
| 76 | (d)One switch socket outlet 3 Pin, 5 Amps, SP on sameboard. |
| 77 | (e) One bell / buzer point controlled by one push button switches on independentboard . |
| 78 | All as per the above item No 68 herein before but with 2.5 Sqmm cable for 3 Pin 5/15 Amps switch socket outlet complete all as specified and directed. |
| 79 | S&F in repair modular switch one way 6 Amps , 1 module type complete all as specified and directed. . |
| 80 | S&F in replacement Bell push6 Amps 1 module complete all as specified and directed. Make :- ANCHOR |
| 81 | S&F in repair modular switch 1 way 16A, 1 module of one way complete all as specified and as directed. |
| 82 | S&F in repair modular socket , 6 Amps , 2/3 pin combined 2 module type complete all as specified and directed. |
| 83 | S&F in repair modular socket6 Amps / 16 Amps , 2/3 pin combined 2 module complete all as specified and directed. |
| 84 | S&F in replacement ceiling rose surface backlite 65 x 20mm size three terminal ISI marked complete all as specified and directed.Make :- ANCHOR |
| 85 | S&F in replecement bellMulti music type ,240 Volt, Single PoleISI marked complete all as specified and directed. Make :- ANCHOR |
| 86 | S&F fan regulator electronic, step type, suitable for ceiling fans of any capacity, pre-wired 230 volts AC 50Hz supply 100Watt complete all as specified anddirected. |
| 87 | S&F lamp holder PVC / Polycarbonate type with cord grip cap suitable for LED lamp fitting complete all as specified and directed. |
| 88 | Supply and fixing LED lights fitting 1x 20 W, 220V,AC decorative box type with driver, holder including LED tube light connecting uptoPVC insulated 3 core flexible cable from ceiling rose to fitting drawn through in PVC flexible conduit including as per site requirementand 2 Nos ofround or square PVC bolck for fixing of TUBELIGHT fitting complete all as per directed. |
| 89 | Supply and fixing in replacement of LED Ceiling light fitting 2\"X2\" suitable for gried ceiling with aluminium housing with anti glare diffuser of capacity 36 Watt complete making all connection using 1.5 sqmm copper conductor muilstranded PVC insulated 3 core flexible cable from terminate point tofitting drawn through in PVC flexible conduit complete all as per directed. Make - C&S Cat Part No.LTCRSLM36WATT2X2Philips/GE/Wipro |
| 90 | S & F LED Bulb 14 /15 Watt complete all as specified and directed. |
| 91 | Supply and fixing LED wall mountedlight aesthetic design with chrome finish and bright output of vegalight of capacity 22 Watt complete with all fixing acessories complete all as specified and directed.Make :- Philips Cat Part No.58158 / C&S / Wipro |
| 92 | S & F in replacement 10 W mirror light having indirect up down light for mirror and as well light application with CCT 6000K, including LED Bulb/Module and Electrical connection with 3 core flexible wire of appropriate size from ceiling rose to the tubelight fitting, complete all as specified and directed. |
| 93 | Supply and fixing ceiling fans complete with three blade with 1.5mm thickness, down rods,regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 220 CMM with service value 6.00 BEE, five star rated with squirrel cage induction motor Copper Winding all as specified and directed. |
| 94 | Supply and fix in repair exhaust fan in repair made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm & 200 mmcomplete all as specified and directed ( Note : suitable E/F place according to site ) |
| 95 | Supply & Fixing LED bldg light fitting luminaire 35 Watt IP-65/66, 230 volts, new generation energy saving & enviormental friendly long life versatile pressure die cast aluminium roadway luminarie with high power LEDs as light source and electronic driver alongwith suitable bracket required as per site for fixing the lightcomplete all asspecified & directed |
| 96 | S&F sheet metal enclosures fordistribution board when MCB to be used SPN ( Single pole and neutral ) 04 way, 240 Volts, sheet metal powder coated, IP 42 protection with 100 Amps rated bus bar, single door typecomplete all as specified and directed. |
| 97 | S&F sheet metal enclosures fordistribution board when MCB to be used SPN ( Single pole and neutral ) 08 way, 240 Volts, sheet metal powder coated, IP 42 protection with 100 Amps rated bus bar, single door typecomplete all as specified and directed. |
| 98 | S&F MCB SPN 40 to 63 AMP 240 Volts, rupturing capacity 10 KA \"C\" Series complete all as specified and directed. |
| 99 | S&F MCB SP, 6 to 32Amps, 240 Volts, rupturing capacity 10 KA \"C\" Series complete all as specified and directed. |
| 100 | Supply ,layingand fixing in trenches / wall / pole wich complete acceseries GI tube light grade 40 mm bore from ground to DB with suitable size clamp complete ,nut bolt ,washers complete all as specified and directed. |
| 101 | M&L for sub main wiring with two runs of 4 Sqmm (2x4 sqmm )1100 volts grade single core FR PVC insulated unsheathed multistranded copper conductorcableconfirming to IS-694 drawn through and including non-metalic PVC rigid conduit 25 mm dia ISI marked with all conduit accessories concealed in walls/roofs/floors etc with one run of 4 Sqmm (1x4 sqmm )single core FR PVC insulated unsheathed copper conductor cableas earth wire complete all as specified and directed. Note:- 2 runs of 4 Sqmm ,one run of 4 Sqmm( 2x4 sqmm + 1x 4sqmm ) cable and one run of conduit will be measured as one unit and follow proper colour code for phase ,Neutral,Earth). |
| 102 | M&L , earthing complete for machinary / Equipment installed at power house / sub station with galavanised steel earth plate electrode of size 60 cmx 60 cmx 6 mm thick buried directly in ground ( earth pit not less then 2.25 m deep below the normal ground level ) with top edge of the earth plate not less then 1.5m below normal Ground level connected galvanised earth lead wire 4.0mm dia by means of bolts, nuts, washerws and check nutsall shown in electrical plate No.5 of SSR Part- I connected to main board / disribution board complete .Earthing GI lead and GI protection pipe 15 mm dia light grade upto 7.5 m from earth pit connecting to machinary/ equipment, testing point, all as specified and testing on completion all as per directed.Note :- (i) The unit rate shall also included for earth work in hard /dense soil , PCC type C-I (1:3:6) chamber , PCC 1:2:4 type B-I cover 50 mm thick reinforced with 8 mm dia TMT bars,150 mm c/c both ways, funnelwith watering pipe 20 mm dia medium graded , GI protection pipe light grade 15 mm dia and wire mesh complete in addition to items No. 1(a) to (e) of preamble (notes) under sub heading earthing specified on SI page No. 389 of SSR Part - II.(ii) Earthing lead and GI protection pipe beyond 7.5 mtrs will be measured and paid separatelly if required under appropriate Schedule. (iii)Earthing shall be tested as specified incasul 19.137 of SSP PART - I 2009 , to the entire satisfication of Engr-in-Charge. (iv) On teting after complataion of earthing,if the desired earth resistance is not obatined the earthing wiil be re done by thecontractor at his on risk and cost to the entire satisfaction of the Engr - in - charge. |
| 103 | Disconnecting and taking out old existing steel/PVC tubing and connections of any description/ grade and in any position in trenches/under floors / on walls etc including all fittings/accessories and fixtures such as bends, union, elbow socket, valves, taps etc, all as directed and specified for 25 mm to 50 mm dia pipe complete all as specified and directed.Note :- Excavation & earth work shall be measured and paid for separately under respective item of Sch \"A\". |
| 104 | Supply and Fixing in any length UPVC pipe 25 mm dia pipe manufactured as per ASTM-D-1785 as per IS-559, Schedule-40 complete with fittings, laid in trenches in required length complete all as specified and directed. Note :Unplasticiscd PVC pipes of pressure rating 10 kgf/cm2 laid intrenches |
| 105 | Supply and Fixing in any length UPVC pipe 50 mm dia pipe manufactured as per ASTM-D-1785 as per IS-559, Schedule-40 complete with fittings, laid in trenches in required length complete all as specified and directed. Note :Unplasticiscd PVC pipes of pressure rating 10 kgf/cm2 laid intrenches |
| 106 | S & Fin repair UPVC Ball valves with operating handle (stop valve) of size 25 mm dia complete suitable for fittings with ASTM - 1785, Schedule 40 UPVC pipes all as specified and as directed. |
| 107 | Excavation in trenches in soft / loose soil nexc 1.5 mtr wide and not exc 1.5 m in depth etc complete and getting out in soft soil inciuding trimming sides and bottom of trenches complete all as specified and directed. |
| 108 | Returming filling in trenches including watering and well ramming in layer not exc 25 cm thick in soft/ loose soil complete all as specified and directed. |
| 109 | Removing excavated surplus soil to a distance not exc 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting pointxall complete all as specified and directed. |
| 110 | Cutting existing steel/ UPVC tubing of any size for alterations, additions or insertions of new GI/CI/ UPVC pipe of size 25mm dia all as specified and directed. |
| 111 | Supplying ,Laying , jointing and testingXLPE insulated, armoured, heavy duty, LT aluminum conductor cable1100 volts grade of size 25 Sqmm, 2 core laid in trenches/ducts, floors, fixed to walls etc completeall as specified and directed. |
| 112 | M&L for sand cushioning in trenches for protection of LT under ground cable including watering and consolidation complete all as specified and directed. |
| 113 | Supplying and laying un-reinforced precast concrete cable cover class LV Type 1, flat, size 250mm x 150mm x 40mm complete all as specified and directed. |
| 114 | NOTE APPLICABLE FOR ALL ITEMS :- If rate quoted for similar/identical items in same part of Sch ‘A’ is at variance, the lowest rate quoted shall only be considered for payment to the contractor. |