| 1 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed. |
| 2 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits,manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed. |
| 3 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed. |
| 4 | Excavating inpost holes( or similar holes) each n exc0.50 cum , getting out,returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in soft/ loose soil complete all as specified and directed. |
| 5 | Surface dressing n.exc 15 cm deep in soft/loose soil complete all as specified and directed. |
| 6 | M&L for Sand filling under floors or in foundationincluding watering and consolidatedand compacted with clean dry sand complete all as specified and directed. |
| 7 | Forming embankments including raising (or lowering) earth, spreading in layers n exc. 30 cm thick; watering, ramming/rolling and finishing to required size, shape, etc., n exc. 1.5 m high from base complete all as specified and directed. |
| 8 | Removing excavated material (soil) n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed. |
| 9 | M&L for hardcore of gauge n.exc. 63 mm, with broken stone or boulder, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surfaces complete all as specified and directed. |
| 10 | M&L for cement concrete1:4:8type D2,using 40mm graded crushed stone aggregate as in foundations filling and mass concrete complete all as specified and directed. |
| 11 | M&L for PCC 1:3:6 type C2, using 40mm graded crushed stone aggregate,asin foundation filling & mass concrete complete all as specified and directed. |
| 12 | M&L for providing pre cast cement concrete type B1 (1:2:4) 20mm graded stone aggregate) solid block in kerb stone of M-25 grade edging etc (of any specification) with plain fair faces incl chambers watering throathings etc setting in cement mortar 1:4 with joints to match complete all as specified and as directed. |
| 13 | M&L for reinforced cement concrete design mix M 25 grade using 20 mm gradedcrushed stone aggregate asin foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. |
| 14 | M&L forreinforced cement concrete design mix M 25 grade using 20 mm graded crushed stone aggregate asinSlabs supported on walls,beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the likecomplete all as specified and directed. |
| 15 | M&L forreinforced cement concrete design mix M 25 grade using 20 mm graded crushed stone aggregate asin chajja , shelves and like etc.complete all as specified and directed. |
| 16 | M&L forreinforced cement concrete design mix M 25 grade using 20 mm graded crushed stone aggregate asin beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed. |
| 17 | M&L forreinforced cement concrete design mix M 25 grade using 20 mm graded crushed stone aggregate asin Columns,pillars,piers,posts and struts complete all as specified and directed. |
| 18 | Supply only integral water proofing compound liquid grade conforming to IS-2645 complete all as specified and directed. |
| 19 | M&L for brickwork with old size fly ash bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed. |
| 20 | M&L for brickwork with old size fly ash bricks, straight or curved on plan to any radius as in half brick thick walls, built in cement mortar 1:4 complete all as specified and directed. |
| 21 | M&L well burnt old size sub Class ‘B’ bricks, laidin trenches for cable protection complete all as specified and as directed by the Engineer-in-Charge. |
| 22 | M&L for20mm thick Granite (of any type) work(table rubbed and polished) for wall lining (veneering to wall) in cement mortar(1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granitecomplete all as specified and directed. |
| 23 | M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams,sides and soffits (if any) of foundation and plinth beams; and similar work; vertical to rough finished surface complete all as specified and directed. |
| 24 | M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work;not exceeding 200mm thick (Horizontal or sloping) rough finished surface flat complete all as specified and directed. |
| 25 | M&L for formworkto chullah hoods, chajjas, troughs and similar items in cluding edgescomplete all as specified and directed. |
| 26 | M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc complete all as specified and directed. |
| 27 | M&L for formwork to sides of pillars, posts, struts, piers,columns and stanchions rough finished surfaces of concrete, square, rectangular or polygonal in shape complete all as specified and directed. |
| 28 | S&F Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staplescomplete all as secified and as directed |
| 29 | M&L for MS work in posts and struts in fencing including cutting tops to shape as directed, drilling holes,notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc.,and similar work conforming to Fe-290 Gde E-165and similar workcomplete all as specified and directed. |
| 30 | M&L for MS framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors;ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165complete all as specified and directed. |
| 31 | S&F Mild steel screw bolts Diameter of neck in 5 to 10mm (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm longcomplete all as specified anddirected. |
| 32 | M&L forMild steel round bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 33 | M&L forTMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 34 | M&L forTMT bars 6 to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 35 | M&L forTMT bars5mm dia and over upto and including 10mm dia in stirrups, spacers and binders cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 36 | M&L forrolled sections as in main and cross beams, hip and jack rafters, purlins where connected to comman rafters and running railsfixed with angle cleats or other connecting plates conforming to Fe 410 W (Gde E-250) quality-A including welded to rafter,purlin complete all as specified and directed. |
| 37 | S&F MSframed work confirming to Fe 410 -W quality Aas in doors or gates of angle or other section with gusset plates, rails,braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete |
| 38 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc.including provission of binding wirecomplete all as specified and directed. |
| 39 | S&F Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc.complete all as specified and directed. (each line wire to be measured) |
| 40 | S&F Steel ventilator with centre hung shutter including hinges, steel peg stay, complete all as specified and directed. |
| 41 | S & F Standard Roller Doors (Galvalume rolling shutters) made of 0.55m RCA steel coated confirming to IS:277 and IS:513 with ball bearings and safety locks, as specified including top cover, anchoring rod, haps and staple and final shop coat of painting erected in position as indicated, complete but gear operated type with bevel gear box and crank handle etc incl taking down old rolling shutter all as per manufactures instruction. (Make Dura Ultima or Equivalent as approved by GE complete all as specified and as directed. |
| 42 | Supply only Chain link MS galvanisd fencing, any size or type complete all as specified and directed. Note: Dia and mesh size as approved by GE. |
| 43 | S&F Pre- painted coloured trapezoidal profiled Galvalume/ Zincalume sheet with min thickness 0.50mm TCT confirming to IS - 513(AZ-150 GSM, Al Zn allay metalic coating with 550 Mpa yield stress as per AS-1397) as in roof covering/cladding towall, fixed with self tapping screws colour exterior coat of silicon modified polyster/BHP x RW paint system 20 micron top coat applied over 5 micron primer and 5 micron polyster back coat applied over 5 micron primer , all fixed with galvanized self drilling self tapping fastner (12-14 x 55 with EPDM seals) complete all as specified and directed. |
| 44 | S&F Pre- painted coloured plain sheet Galvalume/ Zincalume sheet with min thickness 0.50mm TCT confirming to IS - 513(AZ-150 GSM, Al Zn allay metalic coating with 550 Mpa yield stress as per AS-1397) as in roof covering/cladding towall, fixed with self tapping screws colour exterior coat of silicon modified polyster/BHP/ XRW paint system 20 micron top coat applied over 5 micron primer and 5 micron polyster back coat applied over 5 micron primer , all fixed with galvanized self drilling self tapping fastner (12-14 x 55 with EPDM seals) complete all as specified and directed. |
| 45 | M&L for 100mm thick PCC 1:3:6 type C2(Using 40mm graded crushed stone aggregate) as in ramp/hard standing etc finished the surface even and smooth without using extra cement and spikerolling to surface or making impression of extanded metal whilst the concrete is green complete all as specified and directed. |
| 46 | M&L for 75mm thick PCC 1:3:6 type C2(Using 40mm graded crushed stone aggregate) as in sub base complete all as specified and directed. |
| 47 | M&L for 75mm thick PCCtype D2,1:4:8 using 40mm graded crushed stone aggregateas in sub base of PCC floorcomplete all as specified and directed. |
| 48 | M&L for 100mm thick PCCtype D2,1:2:4 using 20mm graded crushed stone aggregateas in sub base of PCC floorcomplete all as specified and directed. |
| 49 | M&L for 25mm thick cement concrete type B-0, 1:2:4 (using 12.5 mm graded stone crushed aggregates)as in sub base of flooring etc completeall as specified and directed. |
| 50 | M & L bricks, sub class B, laid flat, in floors, old size bricks laid flat bedded and pointed in CM 1:3 complete all as specified and directed, |
| 51 | S&F 4mm thick sheet glass ofordinary quality and glazing with oil putty or wooden beading to wooden frame or steel frame or in aluminium framein squares exc 0.50 sqm in each pane complete all as specified and as directed |
| 52 | S&F 4.0mm thick Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sqm in each panecomplete all as specified and directed. |
| 53 | M&L for two coats of synthetic enamel paint over one coat of red oxideon new steel surfaces of any description over 10cm in width or girthincluding preparation of surfaces complete all as specified and directed. |
| 54 | M&L for 40mm dia GI pipe Light grade with all necessary fittings laid in trenches, fixed to wall/pole/under road/floor etc for cable protection complete all as specified and as directed. |
| 55 | S&F steel water tubes medium grade galvanised with all fittings laid in trenches bore of tube 15 mm complete all as specified and directed. |
| 56 | Cutting existing steeltubing 15mm bore of pipes for alterations oradditions (Each cutmeasured) complete all as specified and directed . |
| 57 | S&F Bib taps,15mmcast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule or for CPVC pipes complete all as specified and directed. |
| 58 | S&F stop valve cast copper allow screw down high pressure with crutch or butterfly handle screwed both end form iron pipe or for unionof size 15mm dia complete all as specified and directed. |
| 59 | S&FPVC connectionspipe ,15mm dia size with PTMT nuts of length 450mm complete all as specified and directed. |
| 60 | M&L fornewly plastered surface of wall appying two coat of white or tinted oil bound distemper over one coat of alkali resistant priming paint including 02mm thick wall care putty etc complete all as specified and as directed. |
| 61 | M&L for powder coated(minimum thickness of powder coating 50 micron)anodised aluminium frame for doors,windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as speecified and directed.Note : (i) Weight of Aluminium sections as per actual or as per IS or as per Manufacturer which over is less, shall only be considered for payment.(ii) Cost of all the items/ accessories required for the entire completion of the work shall be deemed to be included in the quoted rate. However glass panes and wire cloth shall be measured and paid separately under respective items. (iii) The accessories (Aluminium mongries etc) required to be provided for window, vents and doors as per directions of Engineer-in-charge shall be provided but weight for the same shall not be considered and no extra cost will be paid. |
| 62 | S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, partitions,windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved makeonforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc.Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snapbeading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge.Note : (i) Weight of Aluminium sections as per actual or as per IS or as per Manufacturer which over is less, shall only be considered for payment.(ii) Cost of all the items/ accessories required for the entire completion of the work shall be deemed to be included in the quoted rate. However glass panes and particle board shall be measured and paid separately under respective items. (iii) The accessories requiredfor partition as per directions of Engineer-in-charge shall be provided but weight for the same shall not be considered and no extra cost will be paid. |
| 63 | M&L for 75mm thick PCC 1:3:6 type C2(Using 40mm graded crushed stone aggregate) as in plinth protectionfinishedeven and smoothusing extra cement.Joints to be given at every 3m interval and corners of buildings and fitted with bituminious mastic or equivalent filler complete all as specified and directed. |
| 64 | M & L for soling (or sub base) with broken boulders or quarried stone, inter stices filled, surface formed and rolled and consolidated to required gradient and camber complete all as specified and directed. |
| 65 | Applying evenly primer/ tack coat with cataonic bitumen (RS-I) @3.50 Kg/10sqm over WBM surface complete as specified. |
| 66 | M&L for 40mm thick Mastic Flooring of grade -ii (all as per IS - 1195-2002) using industrial Bitumen of penetration 50 to 20 and having softening point 85\" to 135\"C etc incl brushing with wire brushes for removing caked mud etc, sweeping with brooms & finally fanning the cleaned surfaces with gunny bags to remove all loose dirts etc all as specified. |
| 67 | M&L for Glazed ceramic tiles coloured 300mmx 450mm , 6 to 7 mm thick as in skirting / dado, set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10 mm thick rendering in cement mortar 1:4 on fair faces of brick work or concrete surface etc complete all as specified andand as directed |
| 68 | M&Lfor Non Skidceramic tiles (coloured) 7 to 8 mm thick , (square / rectangular) area of each tiles exceeding 0.18 sqm but not exceeding 0.38 sqm as in dado/skirting etc, set and jointed in neat cement slurry and pointed with white or coloured cement to matchover and including rendering layer 10 mm thick in cement mortar 1:4etc complete all as specified and directed |
| 69 | M&Lfor Non Skidceramic tiles (coloured) 7 to 8 mm thick , (square / rectangular) area of each tiles exceeding 0.18 sqm but not exceeding 0.38sqm as in floors etc, set and jointed in neat cement slurry and pointed with white or coloured cement to matchover and including screed bed or bedding layer 15 mm thick in cement mortar 1:6for laying floor finishes etc complete all as specified and directed |
| 70 | M&L for providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath,parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand,compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand;complete. completeall as specified and directed. |
| 71 | M&L for rendering 5mm thick on ceiling in cement mortar 1:3 on fair faces of concrete surface finishing surfaces even and smooth without using extra cement complete all as specified and directed. |
| 72 | M&L for rendering 15 mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces and finishing surfaces even and smooth without using extra cement complete all as specified and directed. |
| 73 | M&L forrendering 15 mm thick in two layers 10mm +5mm in cement mortar 1:4 on external surfaces of brick work or concrete surfaces with using WPC finishing the surfaces even and smooth without using extra cement complete all as specified and directed.Note:- WPC will be measured and paid separately under respective item of this schedule. |
| 74 | M&L for 5mm thick rendering in cement mortar1:3 over/soffit of chajja/ceiling, finished surface even and smooth without using extra cement complete all as specified and directed. |
| 75 | M&L for preparing new plastered surface of walls with 2mm thick Birla/Asian wall care putty in two coats and and finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) etc complete all as specified and as directed |
| 76 | M&L preparation of new plastered surfaces of wall and applying two coat of cement base paint over a coat of alkali resistant primer complete all as specified and directed. |
| 77 | M&L for preparation of new undecorated surface of wall and applying three coats of white washcomplete all as specified and directed. |
| 78 | M&L for preparation of new undecorated surface of ceiling and applying three coats of white wash complete all as specified and directed. |
| 79 | M&L for XLPE insulated GI wire/Strip armoured Electric power cable (Heavy duty) with stranded Aluminium conductor 1100 Volts grade, cross sectional area 10Sqmm 2 core laid in trench/pole/on wall completer all as specified and directed. |
| 80 | M&L for point wiring with 1.5 Sq mmsingle corePVC insulated unsheathedcopper FRLSH multi stranded conductor cable in andincludingConcealed PVC conduitof size 20/25mm ISImarked inclusive oftees ,bend ,elbows etc upto and including sunk in Anodized pressed steel box for housing switch socket etc withwhite laminated 3 mm thick sheet cover ISI marked of suitable size complete including PVC insulated multi strandedcopper conductor 1.5Sq mm FRLSH cable as earth wire to common earth dolly for connection to ceiling rose to earth terminalinclcutting, chasses and makinggooddisturbed surface to match with existing finish with plaster forcomplete all as specified and directed. |
| 81 | One light point/ Bell/ one fan point controlled by one switch |
| 82 | One 3 pin socket outlet, 6 Amp on the same board with other switches |
| 83 | One 3 pin socket outlet, 6 Amp independent |
| 84 | M&L for concealed point wiring with FRLSH PVC insulated unsheathed multistranded copper conductor cables 1100 Volts grade of 2.5 sqmm size alongwith one earth continuity conductor with FRLSH PVC insulated unsheathed multistranded copper conductor cable 1100 Volts grade of 2.5 sqmm size through and including 20 mm dia (medium grade) rigid non metallic PVC concealed conduit terminated in and including pressed steel sunken boxes , readily available (Having wall thickness not less than 1.22 mm for boxes upto a size of 200 mmX300 mm and beyond that the wall thickness shall be not less than 1.63 mm) concealed type with 3mm thick bakelite sheet coverfor fixing of switches, sockets, fan regulators etc including testing on completion complete including cutting chases for concealed conduit pinning in making good to facing and pointing in using cement mortar 1:3 and making good to disturbed surface complete all as specified and directed. |
| 85 | S&F Switch piano, flush type single pole, one way 6 Ampcomplete all as per specified and directed. |
| 86 | S&F Switch piano, flush type single pole, one way 16 Ampcomplete all as per specified and directed. |
| 87 | S&F Single Pole and neutral enclosure with a two pin and earth plug and socket complete with one single poleMCB 20/32Ampcomplete all as specified and directed. Make ABB/Legrand/Scheinder |
| 88 | S&F Sheet metal enclosure powder coated for MCB DB double door single pole & Neutral 8 way with 200Amp common bus bar at incomming complete all as specified and directed.Make:- Legrand/havells/L&T/ABB. |
| 89 | S&F Ceiling rose, 3 phase/PVC/polycarbonate, isolated body complete all as per specified and directed. |
| 90 | M&L for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less\"than 1.5 metres below normal ground level, connected to galvanisediron earth strip 25x4mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed. |
| 91 | S&F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd complete all as specified and directed. |
| 92 | M&L for sub main wiring with 2 run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm alongwith one run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm as earth continuity conductor drawn through and including 20 mm dia PVC conduit complete all as specified and directed.Note: For concealed sub-main wiring cutting chases will be included in quoted rate. |
| 93 | Supply and fixing 240V, 10KA \"C\" curve single pole miniature circuit breaker (MCB) 6 to 32 Amps,in the MCB DB complete with connection testing and commissioning. complete all as specified and directed. |
| 94 | Supply and fixing240V, 10KA \"C\" curve SPN miniature circuit breaker (MCB) 6 to 32 Amps,in the MCB DB complete with connection testing and commissioning. complete all as specified and directed. |
| 95 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230V,1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed. Make: Usha/Bajaj/HAVELLS |
| 96 | Supply and fixing LED tube light batten box type made of CRCA sheet with decorative end caps suitable with ultra bright glass LED tube light 1x 18/20 watt T8 type single side connection complete with both end bi-pin holder and all accessories internally prewired and fixed to wall/ceiling incl fittings accessories and connecting up with twin core flexible copper conductor cable suitable size complete all as specified and directed. |
| 97 | S & F for Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 for security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 25 watts with pre wired and necessary mounitng arrangements and provision of 1.5 sq mm three core copper dia GI pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as directed. |
| 98 | S & F for energey efficient exhaust fan of 300mm sweep made of metal body ventil Air-DS type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan for connection and making suitable size of hole to existing brick wall for fan base complete all as directed by GE. |
| 99 | S & F for wall mounted LED tube light fitting 10 watts batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouput box type fitting, 230 volts and intregrated electronic driver connector block etc complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and directed. |
| 100 | S&F electric water heater (Geyser),vertical storage type, 230 V, 50 Hz, stainless steelinner tank,heating element copper with nickle coated 2 KW, 8 bar pressure, capacity 25 litre, BEE 5 Star ratedthermostate (capaliary tube),thermal cutout, Multifunctional valve ( NRV/PRV/Drain), Dry heat protection, Weather proof IP-X4, Heavy duty magnesium anode, High grade ABS material outer body, High Density Puf for high energy efficiency, stainless steel connection pipe etc complete with all accessories withWarranty 2 Year for Geyser, 7 Years for Inner tank and 3 Years for Heating Element. including taking down unserviceable one and deposited to MES Yard complete all as specified and directed. Make :-USHA/ Bajaj/Havells |