| 1 | Dismantling precast cement concrete flooring or stone slabs in walls, partition walls etc. including stacking within 50 meters lead: Thickness upto 40 mm |
| 2 | Providing and Laying of Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 50 mm thick with 20mm nominal size stone aggregate. |
| 3 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:6 ( 1 cement : 6 coarse sand) including Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level |
| 4 | Providing and Applying of 15mm Cement plaster on the rough side of single or half brick wall of mix: 1 : 6 ( 1 cement : 6 fine sand) |
| 5 | Providing and applying of 2mm thick white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 6 | Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm) |
| 7 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primer |
| 8 | Providing and fixing of 35mm thick Imported KD panelled or panelled and glazed shutters for doors, windows and clerestory windows including ISI marked M.S pressed Butt hinges bright finished of required size with necessary screws and other allied fittings/ fixtures complete as per the directions of Incharge Engineer. |
| 9 | Providing and Fixing of Decorative ply wood both side decorative veneer (Type-1) conforming to IS:1328 BWR type for door shutters including all necessary fittings/ fixtures complete as per the directions of Incharge Engineer. |
| 10 | Applying priming coat: With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 11 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coats on new work |
| 12 | Providing and fixing of hardware items of ISI marked of standard quality and make including all necessary fittings/ fixtures complete as per the directions of Incharge Engineer. |
| 13 | Handles 150mm |
| 14 | Handles 100mm |
| 15 | Concealed Locks with locking arrangements. |
| 16 | Tower Bolts 150mm |
| 17 | Tower Bolts 100mm |
| 18 | Lighting point (one lighting point includes wiring of lighting point in 1.5 sq.mm PVC insulated copper wire and 2.5 sq.mm PVC insulated multistrand copper wire,6 amp one way swittch6 amp S pole MCB,10 amp DP MCB,2 way DB MCB and hylem sheet with 16/15 Watt LED surface lights.including cost of channelsas per requirement.One point controlled by one 6 amp switch.( upto 10 meters)including Placing and fixing in position 25mm PVC Conduit pipes with necessary bends and other fittings in RCC Work including cost of service line. |
| 19 | Heating point (one heatting point includes wiring of lighting point in 2.5 sq.mm PVC insulated copper wire and 4.00 sq.mm PVC insulated multistrand copper wire,16 amp one way swittch,10 amp S pole MCB,2 way DB MCB and hylem sheet.including Placing and fixing in position deep junction of cast iron with network Conduit pipes with necessary fittings in RCC Work. |
| 20 | Providing and fixing one fan point includes wiring for lighting points in 1.5sqmm pvc insulated copper wire and 2.5sqmm pvc in multi -strant copper wire including 1200mm ceilling fan electronic fan dimmer.6Amp s pole MCB-10AMP DP MCB 2 Way DB for housing MCB or lightting circuits and hylem sheet.including Placing and fixing in position Fan clamp boxes with MS Fan clamps connected with network Conduit pipes with necessary fittings in RCC Work |
| 21 | Ornamental Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 22 | Providing and fixing of Heavy duty glass panes 3.5mm thick instead of ordinary glass panes 13.75kg/sqm in doors, windows and clerestory windows shutters (Area of opening for glass panes excluding portion inside shall be measured) including cost of beading nails complete as per the directions of Incharge Engineer. |
| 23 | Providing and fixing of 10mm thick ply wood in room ceiling including supporting structure 3\"x3\" and 50x50mm wooden cornice at corners and wherever required and fixing with nails, wooden cornice, other allied fittings/fixtures including carriage of materials complete in all respects as per the directions of Incharge Engineer. |
| 24 | Dismantling of damaged ply ceiling including stacking of serviceable material and disposal of unserviceable material within 50 meters lead or as directed by Incharge Engineer. |
| 25 | Providing and fixing of CGI sheets in chejja and soffits of standard quality including cost of supporting structure nails etc complete including cost of supporting structure 2\"\"x2\"\" of Imported Kail wood. |
| 26 | Providing and fixing of CGI sheets in Eaves boarding of standard quality including cost of supporting structure nails etc complete including cost of supporting structure 2\"\"x2\"\" of Imported Kail wood. |
| 27 | Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.50 mm thick with zinc coating not less than 275 gram/m2 |
| 28 | Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand and manufacturer, in all colours and shades, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of tile 600x600 mm |
| 29 | Carriage of materials from approved source to site of work complete. |
| 30 | Stone aggregate for an average lead of 10Kms |
| 31 | Sand for an average lead of 10Kms |
| 32 | Bricks for an average lead of 60Kms. Please Enable Macros to View BoQ information |