| 1 | Demolition of brick work built in cement orcement lime mortar of any description including quoins,arches,pillars,etc complete all as specified and directed by Engineer-in-charge. |
| 2 | M & L for brick work with Cement Mortar1:6 using sub class \"B\" bricks, old size, straight or curved on plan exceeding 6 m mean radius complete all as specified and directed by Engineer-in-charge. |
| 3 | Taking down cement plaster of any description on brick stone or concrete walls surfaces including raking out joints hacking for keys scrubing down with water etcup to 10m height complete all as specified and directed. |
| 4 | M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cementcomplete. |
| 5 | M&L rendering 10mm thick on brick work or concrete surface in cement mortar (1:6) finished even and smooth without using extra cement complete all as specified & directed by Engineer-in- charge. |
| 6 | M & L for applyingtwo coats of oil bond destemberover one coat of birla white wall care putty on newly plastered surfaces(internal) of walls complete all as specified and directed by Engineer-in-charge. |
| 7 | M&L for preparation of newly plastered surfaces of walls and applying two coats of weather proofing exterior emulsion paint (Apex ultima Luxury emulsion ) of asian or equivalent by spray gun / spray machine as per approved make list in particular specification incl one coat of primer/putty up to 4 story bldg complete all as spd and as directed. Note : Rate quated up to G+3 Bldg including scoffolding. |
| 8 | Dismantling wrought iron or mild steel work of any description such as guard bars, grills etc. |
| 9 | S&F Framed mild steel work as in doors or gates of angle or other sections with gusset plates, rails, braces, tank stagging etc complete drilled for fixing of steel sheeting or other covering doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings(exclusive of steel sheeting or other covering, running rails and gurders) and hanging also fastening and complete all as specified and directed (Fe-410-W(Gde E-250)Quality-A). including demolition of old PCC tank staging |
| 10 | S & F Expanded metal n exc 4 kg weight per square meter, cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members all as specified and directed. |
| 11 | Dismentling asbestos cement corrugated orsemi corrugated sheets in roof fixed with L hook or cranked bolt |
| 12 | S&F pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engr-in-Charge |
| 13 | S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. |
| 14 | M&LSecond classhard-wood in scantlings Add if in repairs, to replace old anddecayed timber (including piecing, scarfing, etc., of old and new timbersif required) and removing defectiveportions to store |
| 15 | M&L for cement concrete 1:2:4 type B1 (using 12.5mm graded stone aggregate) on roof paddingsurface finished even and smooth without using extra cement complete all as spd & directed. |
| 16 | M&L providing and applying the plaster with single component ready to use repair mortar (SMART CARE REPAIR MORTAR or equivalent) capable of applying 15mm average thickness in single layer and finishing with trowel with a bond coat: SBR polymer (@ 10% of cement weight) modified cementious bond coat @ 2.2 kg cement/Sqm of surface area mixed with specified portion of AP SMARTCARE or equivalent Repair Polymer including taking down existing roof treatment of any type and roughning cleaning of old concrete roof and applying neat cement slurry including raking out joints, hacking for key, scrubbing down with water etc., to receive further treatment, complete all as specified land as directed. Make: Asian Paints or equivalent in Sikka, Fosroc and STP Ltd.Note: The application shall be executed on any type of surface and on horizontal/Vertical areas. |
| 17 | M&L providing and applying Smartcare Dampproof, a fibre reinforced elastomeric liquid water proofing membrane formulated with reinforcing acrylic fibers having Sun Reflectivity Index (SRI) of 105 on horizontal/vertical surfaces of roof/wall/chajas in multiple coats @2.0 litre/sqm. Primary [coat is self-priming coat of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1, damp proof : water) and other coats to be applied undiluted. The coating needs to be reinforced with 40 GSM geotextile, to sandwiched between 2nd & 3rd coat of coating. The application shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes complete in all respect as per the direction of Engineer-in-Charge.Notes:- For item ser No 16 & 17 (1) The work shall be executed through authorised applicator of manufacturer only.(2) Authrised Applicator shall be approved by GE before starting of work.(3) All materials shall be procured directly form manufacturer. The purchase voucher shall be produced to the Engineer-in-Charge for his verification of material.Engineer-in-Charge shall deface the original purchase vouchers.(4) Guarantee: The contractor shall furnish a written guarantee for the effectiveness of the water proofing treatment for a period of Eight years in favour of the GE. A sum equivalent to 2.5% (Two point Five Percent) of the cost of water proofing treatment shall be retained by the Govt from the contractor\"s dues as security deposit. The contractor may, however, furnish a fixed deposit receipt in lieu from a Schedule bank pledged in favour of Garrison Engineer. |
| 18 | S & F in repai 1000 ltr capacity three layer white colour rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including dismantling old water tank all as specified in SSR Part I. |
| 19 | Taking up or down steel tubing 15 mm bore, and connections, including cleaning for re-fixing or removal to store in repairscomplete all as specified. |
| 20 | S & F 15 mm bore, steel water tubing, medium grade, galvanized, with all fitting and fixed complete to walls and ceiling or laid into floor in repairscomplete all as specified. |
| 21 | Taking up or down steel tubing 20 mm bore, and connections, including cleaning for re-fixing or removal to store in repairscomplete all as specified. |
| 22 | S & F 20 mm bore, steel water tubing, medium grade, galvanized, with all fitting and fixed complete to walls and ceiling or laid into floor in repairscomplete all as specified. |
| 23 | M & L for removal of plant growth by injection with chemical glyphosphate solution (4 % concentration) @ 20 ml or till refuse by cutting or injection in stem of plants or roots at 30 mm. The area shall then be sprayed with solution 25 ml glyphosphate (4% conc) diluted with 1 ltr of water. The size of block shall be of 2 Qtrs on each floor and vary in number of floors. All roots of plants shall be removed completely and making good the disturbed surface and painted with cement base or acrylic paint all as specified and directed by Engr-in-charge |
| 24 | M&L for two coats synthetic enamelled paint over one coat of red oxide zink primer incl preparation of new surface of steel of any description over 10cm width or girth complete all as specifed and as directed by Engr-in-Charge. |
| 25 | Supply & fixing in repairs vitreous china wash basin, white, flat back of size 550mm x 400mm with full Pedestal including 32mm dia PVC flush pipeand pvc connection pipe with coupling and set of brackets inclcomplete all as specified and directed by Engineer-in-Charge. |
| 26 | Supply & fixing in repairs 10 litres capacityPVCvalveless syphonic action type low level flushing cistern white with inlet, ball valve, float, PVC connection 450mm long including brackets and 32mm dia flush pipe complete all as specified and directed by Engineer-in-Charge. |
| 27 | S&F in repairvitreous china wash down water closet pan (pedestal pattern) white with trap (excluding flushing cistern and flush pipe) including connection to drain and to flushing pipe etc, including plastic water closet seat black closed pattern with flat bottom and cover and mild steel chromium plated hinging device complete all as specified and directed by Engineer-in-Charge. |
| 28 | Dismantling false ceiling boards/ wall pannel any description and in any position incl frame work. |
| 29 | Providing & fixing false ceiling at (a) all heights with GRG (Glass Fibre With Reinforced Gypsum) false ceiling tiles of perforated Size 595 x 595 mm of approved texture, 12mm (b)With sami perforated 12mm thick thick micro tegular design and patterns having moisture micro tegular edged or 1 0 mm content less than 2%, humidity resistance edged GRG thick square edged of 99%, NRC0.50 to 0.75 as per IS false ceiling GRG false ceiling 8225:1987, Noncombustible as per BS tiles 4 76 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter locking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main T runners of size 15 x 32 mm of length 3000mm,cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of s1ze 600x 600mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1 OOOmm length and L shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall I partition with the help of plastic rawl plugs atand 450mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in Charge. |
| 30 | S&F Factory Made 18mm thick 100% Solid WPC,HDMR ( Wood polymer Composite ) Laminated Board of required size comprising of virgin PVC resin of K Value 57-60 ( Suspension Grade ), Calcium Carbonate and natural fibers ( Wood Powders/ rice husk/ wheat husk ) and Non toxic additives, made from Extrusion process WPC foam sheet Single Extruded ( Inner ) with having minimum density not less than 650 kg/cbmhaving good screw holding capacity ( Screw Withdrawal strength of 2000 N ( Face ) & 1100 N ( Edge ), Minimum Compissive of 50 N/mm2 , Modulus of elasticity 850N/mm2and esistance of spread of flame of Class A category with Property of being Termite/ Borer Free.Water/ Moisture Proof and Fire Retardant. WPC to be Laminated with PVC foil of minimum 14 microns thick of approved design pasted on both faces of shutter and fixinng stainless Steel butt hinges of required size with necessary full body threaded star headed counter sunk SS Screws. All as per direction of Engineer -In-Charge, Material test certificate and authentication should be compulsory provided by the manufacturing company : For WC/Bathroom/Toilet/Kitchen and Cabinets.including required of piano hinges, magnet cathes and required as site of 75mm long SS handle all as specified and directed by engineer in charge Note- in this item piano hinges and 75mm SS handle not paid saprately. |
| 31 | Taking down care fully copper/aluminium point wiring from wooden batten or conduits (light, fan, socket or power) complete incl fittings such as switches, sockets, ceiling roses, pendents, regulators, light fittings any type etc to be measured seperately) and making good disturbed surfaces of walls, floors etc complete all as specified and directed by Engineer in charge. |
| 32 | M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through and including non-metalic rigid PVC conduit medium grade ISI Marked and all conduit accessories concealed in wall/ceiling/fixed to roof/truss/columns etc and including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty, fabricated branded modular metal flush box / M S steel terminal boxes, concealed in walls with suitable modular inner and outer plate / 3 mm thick laminated top sheet cover for housing switches , socket out let and fan regulators etc. all as specified and as directed for the followings:- |
| 33 | One light/exhaust fan point controlled by oneway switch |
| 34 | One bell /buzzer point controlled by one bell push |
| 35 | One light point controlled by two Nos two way switches |
| 36 | One 3 pin 5 Amps socket outlet point controlled by oneway switch on independent board. |
| 37 | One 3 pin 5 Amps socket outlet point controlled by oneway switch on same board |
| 38 | All as per item No 2 but point wiring with 4 Sqmm single core copper cable and earth continuity wire with 4 Sqmm single core stranded copper cable for one three pin 15 socket outlet point on independent board complete all as specified and directed by Engineer in charge. |
| 39 | M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through existing PVC conduit, including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty and fabricated branded modular metal flush box/M S Steel terminal boxes, concealed in walls with suitable modular inner and outer plate/3 mm thick laminated top sheet coverfor housing switches , socket out let and fan regulators etc. all as specified and as directed for the followings:- |
| 40 | One light/fan point controlled by oneway switch |
| 41 | One bell /buzzer point controlled by one bell push |
| 42 | One light point controlled by two Nos two way switches |
| 43 | One 3 pin 5 Amps socket outlet point controlled by oneway switch on independent board. |
| 44 | One 3 pin 5 Amps socket outlet point controlled by oneway switch on same board. |
| 45 | All as per item No 4 but point wiring with 4 Sqmm single core copper cable and earth continuity wire with 4 Sqmm single core stranded copper cable for one three pin 15 socket outlet point on independent board complete all as specified and directed by Engineer in charge. |
| 46 | Taking down old unserviceable MS Steel terminal boxes from wall and supply and fixing fabricated branded modular metal flush box 1module/2 module concealed in walls with suitable modular inner and outer plate for housing switches, socket out let and fan regulators etcincluding make good of disturbed surface complete all as specified and directed by Engineer in charge.Note-Switch,socket, regulator will be paid separately |
| 47 | Taking down old unserviceable MS Steel terminal boxes from wall and supply and fixing fabricated branded modular metal flush box 3 module/4 module concealed in walls with suitable modular inner and outer plate for housing switches, socket out let and fan regulators etcincluding make good of disturbed surface complete all as specified and directed by Engineer in charge.Note-Switch,socket, regulator will be paid separately |
| 48 | Taking down old unserviceable MS Steel terminal boxes from wall and supply and fixing fabricated branded modular metal flush box 6 module concealed in walls with suitable modular inner and outer plate for housing switches , socket out let and fan regulators etc.including make good of disturbed surface complete all as specified and directed by Engineer in charge.Note-Switch,socket, regulator will be paid separately |
| 49 | Taking down old unserviceable MS Steel terminal boxes from wall and supply and fixing fabricated branded modular metal flush box 8 module concealed in walls with suitable modular inner and outer plate for housing switches , socket out let and fan regulators etcincluding make good of disturbed surface complete all as specified and directed by Engineer in charge.Note-Switch,socket, regulator will be paid separately |
| 50 | M&L in replacementswitch Modular type 6 Amps 1 Way,1 module, 230V AC complete all as specified and directed by Engineer in charge. |
| 51 | M&Lin replacement switch modular type 6amp SP two way, 1 module complete all as specified and directed by Engineer in charge. |
| 52 | M&L in replacement Modular Bell pushbutton SP, 6 Amps, 1 module 230V AC complete all as specified and directed by Engineer in charge. |
| 53 | M&L in replacement Modular socket outlet 2/3 pin 6 Amp socket 2 module complete all as specified and directed by Engineer in charge. |
| 54 | M&L in replacement switch Modular type 16 Amps 1 way, 1 module with modular plate 230V AC complete all as specified and directed by Engineer in charge. |
| 55 | M&L in replacement Modular socket outlet 2/3 pin 6/16Amp universal socket 2 module complete all as specified and directed by Engineer in charge. |
| 56 | M&L in replacement modular stepped type electronic fanregulator 120W, 2 module all as specified and directed by Engineer in charge. |
| 57 | M&L in replacement switch piano flush button type single pole one way 6 Amps complete all as specified and directed by Engineer in charge. |
| 58 | M&L in replacement switch piano flush button type single pole two way 6 Amps complete all as specified and directed by Engineer in charge. |
| 59 | M&L in replacement bell push single pole 6 Amps complete all as specified and directed by Engineer in charge. |
| 60 | M&L in replacement switch piano flushbutton type single pole 16 Amps complete all as specified and directed by Engineer in charge . |
| 61 | M&L in replacement socket outlet, 2 in 1, 3 pin 6 and 16 Amp single pole complete all as specified and directed by Engineer in charge. |
| 62 | M&L in replacement socket outlet 5 pin 6 Amp flush button type complete all as specified and directed by Engineer in charge. |
| 63 | M&L in replacement regulator electronic switch/socket type 5 steps suitable for 1200/1400 mm sweep 230 volts all as specified and directed. |
| 64 | M&L in replacement bell electric (ding dong) 230 volt, SPall complete all as specified and directed by Engineer in charge . |
| 65 | M/L in replacement insulated body, angle holder (metal ring) with back plate complete all as specified and directed by Engineer in charge. |
| 66 | S&F ceiling rose PVC/Polycarbonate type with three terminals complete all as specified and directed by Engineer in charge . |
| 67 | M&L in replacement sheet metalenclosure, single pole and neutralwith a two pin and earth plug and socket 240 Volts grade20Amps complete with onesingle poleMCB \"C\" series 10/20 A capacity complete all as specified and directed by Engineer in charge. |
| 68 | Supply and fix LED batten luminaire surface mounted, 4 feet system wattage of 20 Watts, > 2000 systems lumen outputwith lifetime of 25000 burning hours with 70% of its initial lumen maintained. CRI>70, Power Factor >0.90, THD< 10%, colour temperature-6500K, surge protection 2.5 KV in CM, IP-20 protected, Class-1,short circuit and over circuit protection, voltage range-180 to 270 Volts AC, temperature range 0 to 45 Degree C minimum andincluding connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed completeallas specified and directed. |
| 69 | Supply and fix LED batten luminaire surface mounted 2 feet system wattage of 10 watts and not less than 1000 lm with life time of 25000 burning hours with 70% of its initial lumen maintained, CRI >70, power factor > 0.90, THD < 10%, color temperature >6500 K , surge protection 2.5 KV in CM IP- 20 protected,voltage range - 180 to 270 volts AC, temperature range 0 to 45 Degree C minimum, system efficiancy at luminarie level ≥100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed. |
| 70 | Supply and fix LED 9/10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 100 lm/W with a life class of 25,000 burning hours at L70 criteria,Power Factor >0.90, driver with Voltage range 180-270V, Temperature range 0 to 45 Deg minimum, Driver efficiency >85%, THD<10%, CRI>70, Color Temperature-6000K, surge protection of 2.5 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmmcopper conductor flexible wire completeallas specified and directed. |
| 71 | S&F in replacement of decorative type wall mounted luminaire (Comet)with unbreakable poly carbonate materials suitable for 1x14 watt LED bulb B22 base complete all as specified and directed by Engineer in charge. |
| 72 | Supply and fix surface ceiling mounted, LEDdown light fitting 12 watts with die cast aluminium housing and system wattage of 12W, system efficacy at luminary level ≥ 100 Lumens/watt, 25000 burning hours, 6500K color temperature with CRI >70, Power Factor > 0.90, with multi stage high Isolate CC-CV operated driverwithvoltage variation range - 180 to 270 Volts AC, and surge protection of 2.5 KV, and including connecting up with PVC sheathed 3 core 1.5Sqmmcopper conductor flexible wire completeallas specified and directed. |
| 73 | S&F 35W high efficient LED street light fitting with pressure die cast Aluminum housing and has lenses specially designed for street lighting with polycarbonate cover, system level efficacy of the luminarieshould more than 110 lm/W. Color temperature is around 6500 K with a color rendering index of 70. The luminaire is IP-65 protected.It has an electronic driver with a power factor>.0.90, voltage variation range 180-270V, THD<10%, High and low protection along with a surge protection of 4 KV including provision ofsuitable dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on wall fixed complete as specified and directed. |
| 74 | M & L for opening up the winding of ceiling fan 1200/1400 mm sweep any make any type and rewinding with super enamelled copper winding wire after inserting super enamelled insulating material binding it with insulating tape etc completely and varnishing well including drying completely. Replacement of worn out /unserviceable capacitor bearing , bush , safety pins, nuts, bolts, washers , rubber bush with ceiling fan clamp, cable PVC flexible 23/0076 and testing the ceiling fan after re-fixing of the blades to the entire satisfaction of Engineer-in-Charge. |
| 75 | Supply and Fixing LED bulb 9 watts, 900 lumens output, 6500K suitable for B-22 base complete all as specified and directed by Engineer in charge . |
| 76 | Supply and Fixing LED bulb 14 watts, 900 lumens output, 6500K suitable for B-22 base complete all as specified and directed by Engineer in charge . |
| 77 | Supply and fixin repair MCB SPN 63 Amps 240 volts 10 KA 50 HZ \"C\" curve complete all as specified and directed by Engineer in charge. |
| 78 | Supply and fixin repair MCB SPN 40 Amps 240 volts 10 KA 50 HZ \"C\" curve complete all as specified and directed by Engineer in charge. |
| 79 | Supply and fixin repair MCB SPN 32 Amps 240 volts 10 KA 50 HZ \"C\" curve complete all as specified and directed by Engineer in charge. |
| 80 | Supply and fixin repair MCB SP 6-32 Amps 240 volts 10 KA 50 HZ \"C\" curve complete all as specified and directed by Engineer in charge. |
| 81 | Supply and fixing ventilating fan250 mm sweep, 1250 RPM, non metallic resin body,single phase 240 volts AC 50 Hzand connecting up complete including louvers and provision of copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan completeall as specified and as directed. |
| 82 | Supply and fixing ventilating fan200 mm sweep, 1250 RPM, non metallic resin body,single phase 240 volts AC 50 Hzand connecting up complete including louvers and provision of copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan completeall as specified and as directed. |
| 83 | Supply and fixing exhaust fan300 mm sweep (steel Body), 1250 RPM, non metallic resin body,single phase 240 volts AC 50 Hzand connecting up complete including louvers and provision of copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan completeall as specified and as directed. |
| 84 | Supply and fix wall mounted fan 400mm, 230 volts, 50 Hz 1420 RPM with 90 degree oscillation and having speed control by pull cord system all as specified and directed. |
| 85 | S & F water heater storage type (Geyser) steel body, vertical type with suitable size of fastner and including provision and connecting up of SS braided pipe with adopter for inlet and outlet water connection, having adjustable knob for temperature control and inner tankmaterial of superior glass lined tank and outer body material ABS with high pressure with standing capacity upto 8 bar pressure completeall as specified of capacity 25 ltr having heating element 2 KW and not less than 5 star rating with minimum two year warrant on product.Note : old unservicable geyser will be deposoted in MES yard. conversion against low rating to 5 star rating. |
| 86 | Supply and fixing wall mounted angular electric chimney black colour of suction power not less than not less than 1200Cum/Hr,Al casette with stainless steel outer layer, touch control panel,3 speedmotor with 250 watt with decorative smart cooker hood SS and glass, energy efficent LED light with digital display, including ducting not less than 12 feet as per site required complete all as specified and as directed by Engr-in-Charge. |
| 87 | Supply and fixing ceiling fans complete with blade, down rods, with remote and accessories rated speed not less than 330 RPM, 230 V, 1200 mm sweep, air delivery not less than 220 CMM, BEEfive star rated voltage range 180 - 270 volts with brushess direct current motor (BLDC)all as specified and directed by Engr in Charge. (Against BLDC converson). Old fan deposited to MES yard. |
| 88 | S&F in repair sub main wiring with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable with one run of 2.5 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable as earth continuity conductor, drawn through and including 25 mm dia non metallic rigid PVC conduit and conduit accessories on surface of walls complete all as specified and directed. |
| 89 | Supply and fix in repair sub main wiring complete with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable with one run of 2.5 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable as earth continuity conductor, drawn through existing metallic/ non metallic conduitin walls all as specified and as directed. |
| 90 | Supply and fix in repair Sub main wiring complete with two runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable with one run of 6 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable as earth continuity conductor, drawn through existing metallic/ non metallic conduitin walls all as specified and as directed. |
| 91 | Supply and fix in repair Sub main wiring complete with two runs of 10 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable with one run of 10 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable as earth continuity conductor, drawn through existing metallic/ non metallic conduitin walls all as specified and as directed. |
| 92 | S&F plug top, 3 pin,20 amp earth metal clad (ISI marked) complete all as specified and directed by Engineer in charge. |
| 93 | S&F socket 3 pin20 amp earth metal clad(ISImarked) complete all as specified and directed by Engineer in charge . |
| 94 | S & F PVC Gang box surface type heavy duty suitable for single switch & socket 5 Amps complete all as specified and directed by Engineer in charge . |
| 95 | S & F PVC Gang box surface type heavy duty suitable for two switch & two socket 5 Amps complete all as specified and directed by Engineer in charge . |
| 96 | S & F Gang box surface type heavy duty suitasble for 15 Amps switch and socket complete all as specified and directed by Engineer in charge. |
| 97 | M & L forin replacement onlysingle core PVC insulated cable 1.5 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits, all as specified and directed by Engr-in-Charge. |
| 98 | M & Lin replacement foronlysingle core PVC insulated cable2.5Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-Charge. |
| 99 | M & Lin replacement foronlysingle core PVC insulated cable4Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-Charge. |
| 100 | M & Lin replacement foronlysingle core PVC insulated cable 6Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-Charge. |
| 101 | M & Lin replacement foronlysingle core PVC insulated cable 10Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-Charge. |
| 102 | M&L in replacement copper cable flexible 2 corePVC insulated of size 23/.0076 ll as specified and directed by Engr-in-Charge. |
| 103 | Supply and fixing LED Bollard integral decorative with PMMA diffuser 10 watt of height not less than 0.6 meterwith IP 65 protection suitable for single phase 230 volts 50 HZ AC Supply including LED bulb , Poles, service wire and cement work complete all as specified and directed by Engineer-in-Charge. |
| 104 | Supply and fixing new generation, post top energy saving environmently friendly 25W , long life aesthetically designed with symmetrical light distribuiton spun aluminium landscape luminaire with high power LED as light sources. |
| 105 | Supply only SS braided pipe of 12 mm ((internal) suitable for hot/cold water, 60 cm long with brass nuts and rubber washers complete all as specified and directed. |
| 106 | Supply only heating element of 2 KW any type with nut bolt washercomplete all as directed. |
| 107 | Supply only replacement of capacitor 3.15 Mfd,240 V complete all as specified and directed. |
| 108 | Supply only replacement of capacitor 1.5 Mfd,240 V complete all as specified and directed. |
| 109 | Schedule of Credit |