| 1 | NOTE:- (Applicable for all parts/items/):- The bidders/contractorsare advised to read tender document, all drawings & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates. |
| 2 | Lumpsum price workedout by the tenderer for BUILDING& STRUCTURE WORKS as listed in Schedule ‘A’ Part-I |
| 3 | Lumpsum price worked out by the bidder/ tenderer forSITE CLEARANCE, SITE DEVELOPMENTS & EARTH WORKS as listed in Schedule \"A\" Part-II. |
| 4 | Lumpsum price worked out by the bidder/ tenderer forINTERNAL ELECTRIFICATIONas listed in Schedule \"A\" Part-III |
| 5 | Lumpsum price worked out by the bidder/ tenderer for ROAD, PATH, CULVERT AND HARDSTANDING as listed in Schedule \"A\" Part-IV. |
| 6 | Lumpsum price worked out by the bidder/ tenderer for SEWAGE DISPOSAL as listed in Schedule \"A\" Part-V. |
| 7 | Lumpsum price worked out by the bidder/ tenderer for AREA DRAINAGEas listed in Schedule \"A\" Part-VI. |
| 8 | Lumpsum price worked out by the bidder/ tenderer for FENCING AND GATEas listed in Schedule \"A\" Part-VII. |
| 9 | Lumpsum price worked out by the bidder/ tenderer for RCC/STONE MASSONRY RETAINING WALLas listed in Schedule \"A\" Part-VIII |
| 10 | Lumpsum price worked out by the bidder/ tenderer for SUMMER APPLIANCEas listed in Schedule \"A\" Part-IX. |
| 11 | Lumpsum price worked out by the bidder/ tenderer for LIGHTNING PROTECTOIN as listed in Schedule \"A\" Part-X. |
| 12 | Lumpsum price worked out by the bidder/ tenderer for EXTERNAL WATER SUPPLY as listed in Schedule \"A\" Part-XI. |
| 13 | Lumpsum price worked out by the bidder/ tenderer for EXTERNAL ELECTRIC SUPPLYas listed in Schedule \"A\" Part-XII. |
| 14 | Lumpsum price worked out by the bidder/ tenderer for INTERNAL WATER SUPPLY as listed in Schedule \"A\" Part-XIII. |
| 15 | Sch \"A\" Sec-XIV (Miscellaneous Items) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as \"Rs 0.00\" under Col. 5 siginifies this fact only. |
| 16 | S&fx electric water heater storage type, steel body with copper inner tank and heating element upto 2 kW capacity 50 litres, BEE 5 star rated complete with all accessories such as safety valve, thermostate, NRV, connection pipe complete all as specified and directed. |
| 17 | S&F,testing and commissioning of voltage stablizer for automatic operation, single phase, naturally air cooled, indoor type, designed for input variation between 170V to 250V with stablized output voltage at 230V with accuracy of ±2.5% and of capacity 1.0 kVA complete all as specified and directed. |
| 18 | Supply, Install, Testing and Commissioning of 11kV 630 Amps 21 KA for 3 Sec, SF6 insulated, both side extensible, outdoor type, fully motorized, in combination of 1 No VCB module as Incomer and 01 No Load Break Switch as Outgoing (VC), consisting of copper busbar in SF6 insulated 304 (Non - Ferrite Non - Magnetic Grade) stainless steel enclosure of thickness 2.5 mm with manometer fixed on the tank. The Breaker shall have mechanical ON/OFF indicator with hand trip device and spring charging, spring release coil. The HV switchgear and control gear should be confirming to IEC - 62271-1,100,200. The RMU gas tank should be internal arc tested for 21 KA for 1 second with IAC - AFLR classification for gas tank. The complete RMU mimic and cable chamber should be covered by a single door to have ingress protection of minimum IP54. The RMU design should support site replaceable HT cable bushing and VCB should be RMU Manufacturer\"s own make. (At 457 FD Hospital area)RMU should have following:- 1 No, microprocessor based self powered numerical relay with Over Current / Earth fault & short circuit protection (with Rs 485 port and modbus protocol) in VCB feeder, Relay should display each phase current.- 3 Nos, Protection CT shall be of Burden 2.5 VA, ratio 200 - 100/1A, Class of Accuracy class 5P10 for O/C and E/F protection for VCB outgoing feeder.(CT ratio is indicative and may vary during detailed engineering).- 1 No Manometer for each tank- 1 No Voltage passage indicator for each feeder.- Completely touch proof screen seperable termination kit for all the feeder Modules considering installation shall be above 1200 meter altitude. |
| 19 | Serial item No. 14.003 continued--- - Vacuum Interrupter & RMU should be of same make for better life cycle optimization.- Basic insulation level of complete RMU shall be 28KV (RMS) / 75 KV (Peak)- The VCB operating sequene must be O-0.3-CO-3 MIN-CO & tested for 10000 CO mechanical operation- Complete RMU must be scada ready and all the wirings for control and Indication of each module, Better health, Gas pressure monitoring etc to brought to a dedicated set of Terminal bolck and there shall be space to be left to mount FRTU in future. (System house / Franchise/license partner are not allowed).Note:- (i) Cost of supply and fix of Switchgears / Breakers havingterminals / disconnecting links for termination of CT wiring including fuses complete all as required at site are deemed to be included in the quoted rate.(ii) Cost of Foundation including construction material as per manufacture design complete is deemed to be included in the quoted rate.(iii)Rate is inclusive for dismantling, taking down existing HT cable from 4 pole / 2 pole structure and connecting Switchgears / Breakers.(iv) Rate of cable end joint shall be measured and paid seperately under relevant item.(v)Cost of additional base channel required at site shall be measured and paid seperately.(vi) Rate is inclusive for any other works which are not included in item but required at site for commissioning of Switchgears / Breakers / VCB including marking, numbering, by synthetic enamel paint providingdanger board etc.(vii)Contractor shall provide AMC include callibration of HT panels, VCBs, CT / PTs, Relay settings for the Switchgears / Breakershere in above under defect liability period (DLP) i.e 24 months by engaging Service Engineer from OEM of eqpts without any extra cost and site inspection, testing and callibration report will be submitted on before commissioning and subsequently once in six months to Engr-in-charge . Compensation @ Rs 80000.00 shall be recovered from contractor due in case failure.(viii) Rate is inclusive for submitting completion Drg and network details after testing & commissioning but before completion of work. Display board (illuminated) of size not less than 2.0 Mtr x 1.5 Mtr shall also be provided by the contractor at MRS Sub Stn without any extra cost. (ix) Detail Technical Specification of SF6 Metal enclosed, Outdoor / Indoor Switchgears / Breakers as per Particular Specification attch as Appx \"A\" |
| 20 | Shifting and installation of existing distribution transformer upto 200 kVA, 11/0.433V / nearest available capacity / through existing station rationalisation source complete including connection at proposed location all as specified and directed. |
| 21 | S&F Cast iron cable route indicator width 4\" with embossing mark as HT/LT cable, shall be directly burried into the ground and having withstand capacity in all type of weather conditions and physical impact and painted with bright colour complete as specified and directed. |
| 22 | Supplying and laying of DWC HDPE pipe ISI marked of size 120 mm dia (OD-120 mm & ID-103 mm nominal) along with all accessories like socket, bend, couplers etc. conforming to IS:14930, Part Ilincluding fittings and cutting, jointing etc. in the existing trench complete all as specified and directed. |
| 23 | Supplying and laying of DWC HDPE pipe ISI marked of size 50 mm dia (OD-50 mm & ID-38 mm nominal) along with all accessories like socket, bend, couplers etc. conforming to IS:14930, Part Ilincluding fittings and cutting, jointing etc. in the existing trench complete all as specified and directed. |
| 24 | S & F loop in loop out junction box of size 300 x 200 x 110 mm made out of 1.6mm thick SMC sheet weather proof dust and vermin proof with hinged door and locking arrangements with slanting cover on top and provision of 04 nos aluminium bus bar of size 20x5 mm fixed on insulator and one MCB of capacity 10 Amp complete fixed on pole with and including suitable size MS flat iron clamp nut, bolt and washers complete all as specified and as directed. |
| 25 | Fabrication, supply, installation, testing & commissioning of electrical cubical control panel board (PTTA Panel) factory assembled weather, Dust & Vermin proof, totally enclosed IP-54 protection Plinth mounted Outdoor factory fabricated of 3.15 mm CRCA MS sheet of suitable size, 3 phase, 4 wire, 415 Volt AC, 50 Hz complete duly painted with powder coating complete with locking arrangement, earthing terminals with suitable rating aluminium bus bar insulated with FRP heat shrinkable sleeves of relevant colour wit necessary insulators for incoming/outgoing Circuit breakers including and mounting measuring instrument such as voltmeter, Ammeter, CT’s Phase LED indicator lamp R-Y-B, selector switch for incoming, cables connection with suitable cable glands, lugs including grouting of feeder pillar box 60 cm above ground level by providing 90 cm long angle iron size 50x50x6 mm welded on all four corner embedded in PCC (1:2:4) using 20mm graded up to 30 cm as latest edition of IS 8623, IS 13947 & IS 2147 complete all as specified and directed(Near Single liv OR bldg)INCOMING:-MCCB 4 pole, 100 Amps, 16 kA, Thermal Magnetic based, adjustable range 0.7 to 1 In - 01 No OUTGOING:-(a) MCCB 4P 40A, 16kA, Thermal Magnetic based, adjustable range 0.7 to 1 In - 03 No (b) TPN MCB 6-32A, 10kA, \"C\" curve - 01 No (Street light)(c) Intelligent panel meter to measure voltage, current frequency, power factor, kWH, etc with all connected CTs -01set(d) LED indicating lamps with colour R,Y,B - 01 set |
| 26 | Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 Mpa working pressure complete all as specified and directed |
| 27 | Fabrication, supply, installation, testing & commissioning of IP-66, IK10 protection, outdoor type, double door pedestal, Street light timer controlled panel of 5kW,3 phase, 4 wire, 415 Volt AC, 50 Hz with an astronomical timer driving two three phase feeders complete with floor mounted, fabricated of 3.15 mm CRCA MS sheet of suitable size with UV-stable gasket, duly powder coated complete with locking arrangement, earthing terminals, with FRLSH control wiring includingmounting Phase LED indicator lamp R-Y-B, selector switch for incoming, cables connection with suitable cable glands, lugs with all complete accessories. Complete panel unit grouting60 cm above ground level by providing necessary angle iron support on all four corner embedded in PCC (1:2:4) using 20 mm graded up to 30 cm complete with the following:- |
| 28 | Serial item No. 14.011 continued...Bus-bar : 3P+1N - Aluminium busbar, 40 A mounted on 1.2 kV insulation sleeves, form-2bIncomer : TPN MCB 6-32A, 10kA, \"C\" curve - 01 NoOutgoing : (i) MCB 4P 16 A, 10kA \"C\" curve - 02 Nos(ii) Power contactor - 4P, 16-20 A AC - 01 No(iii) Surge Protection device Type 2, 3P+N, Uc 275 V (N-PE)/320-350 V (L-PE), Imax≥20 kA per pole, with thermal disconnector and remote contact - 01 NoControl & automation:-(i) Astronomical timer : Legrand Astro Rex or equivalent, 2 channel, 230V AC, ≥per chan(pilot duty), lay/long programmable, DST auto, ±120 min offset - 01 No(ii) 3 position (Hand-Off-Auto) selector - 01 No(iii) Master bypass : AUTO/BYPASS selector to force panel ON irrespective of timer - 01 No(iv) Manual OFF pushbutton -02 (per outgoing feeder)(v) LED indicating lamps with colour R,Y,B - 01 setNote: (i) Clearance for 25% future feeders shall be made provisioned(ii) The cost of earthwork, panel foundation is deemed to be included in the quoted rate of contractor |
| 29 | Supply, install, testing and commissioning of Smart energy meter (IS-16444), AC whole current, three phase, 4 wire, CT operated Smart Energy meter of Class 0.5 S, 415 V, 50 Hz, 1b 5A complete all as specified. The meter shall communicate with Head End System (HES) on any of the communication technologies mentioned in IS-16444 Part-I in a secure manner. The selection of communication technology should be as per the site condition and as per design consideration of AMI implementing agaency to meet the performance. The smart meter can based on RF Mesh communication technology or Cellular communication technology. The meter shall be provided with transparent polycarbonate ABS thermoplastic box with sealing arrangemenrs of suitable size as per the requirement of OEM of electric meter. The cost of meter would include the supply of current transformer, rated burden 15VA, accuracy class 0.5S, frequency 50Hz and voltage class 660V, effectively earthed and CT ratio suitable as (60/5 to 1000/5) completecomplete all as specified and as directed |
| 30 | Fabrication, supply, installation, testing & commissioning of electrical cubical busbar control panel board factory assembled weather, Dust & Vermin proof, totally enclosed IP-54 protection Plinth mounted Outdoor factory fabricated of 3.15 mm CRCA MS sheet of suitable size, 3 phase, 4 wire, 415 Volt AC, 50 Hz complete duly painted with powder coating complete with locking arrangement, earthing terminals with 300A, 4way aluminium bus bar, insulated with FRP heat shrinkable sleeves of relevant colour with necessary insulators for incoming/outgoing controls including 01 x MCCB 250A, 4P, 36kA, Miroprocessor based electronic release with LSIG protection as incoming, cables connection with suitable cable glands, lugs including grouting of feeder pillar box 60 cm above ground level by providing 90 cm long angle iron size 50x50x6 mm welded on all four corner embedded in PCC (1:2:4) using 20mm graded up to 30 cm complete all as specified and directed |
| 31 | M&L for construction of 100 users septic tank in odinary soil, foundation in PCC (1:2:4) type B1 using 20 mm graded crushed stone aggregate, brick construction wall in CM (1:4), M-20 grade RCC cover slab , RCC pre-cast manhole cover 100 mm thick of M-20 grade concrete having 6 mm plate embedded all around / fibre reinforced cover with angle iron frame , vent shaft and sludge chambers complete all as specified and as shown on TD drawings. |
| 32 | M&L for construction of sokage wellof size 3.60 m internal dia and 6.00 m effective depth in odinary soil, foundation in PCC (1:3:6) type C1 using 20 mm graded crushed stone aggregate, honey comb brick construction wall in CM (1:4), M-25 grade RCC cover slab , including intercepting chamber, screen chamber with brick wall construction in CM(1:4) ,RCC pre-castcover cover slab 100 mm thick of M-25 grade concrete, brick bats filling complete all as specified and as shown on TD drawings. |
| 33 | S&F LED type bed side wall mounted light fitting 9/10 Watt , housing- glass, frosted type, metallic frame, adjustable type complete all as specified and directed. |
| 34 | S&F wall mounted type fans of 400 mm sweep, 03 blades aerodynamically balanced with 60 degree oscillation, working Voltage range 230 V, with service value not less than 1.2 BEE 5 star rated with brush less direct current motor(BLDC), the super efficient BLDC motor 50Hz and Noise level not more than 64 dB with 2 years warranty complete all as specified and directed. |
| 35 | S&F electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW, complete of capacity 50 Ltrs, BEE 5 Star rated complete with allaccessories such as safety valve, thermostate, NRV, connection pieces for for hot and cold water complete and including all fixing accessories complete all as specified and directed.NOTE: - Contractor has to provide5 years warrantyfrom the date of installation. |
| 36 | S&F modular type TV socket. RJ46, 1 module complete all as specified and directed. |
| 37 | S&F modular blanking plate modular type suitable for fixing in modular switch board complete all as specified and as directed. |
| 38 | S&F epoxy powder coated sheet metal enclosure for DBs, double door, Triple pole and neutral (VTPN) 415V, 4 ways suitable for fixing MCCB 4P/3P upto 160 Amps as incomer and MCB TP/SP as out going, fitted with 250 Amps rated copper bus bar for each phase with 02 Nos neutral bar & 02 NOs Earth bar and cable ties for cable management fully insulated busbar & shrouded Neutral bars pre-fitted with masking sheet, the DB shall be ofIP-54 Protection complete all as specified and directed |
| 39 | S&F Surge Protection Device (SPD) Single Phase and neutral, T2 -limb, Imax 20 KA per pole complete fixed in distribution board and making connections complete all as specified and directed. |