| 1 | Supply only polyester triangular fibres as secondary reinforcement in all types of concrete and mortars as approved by GE. |
| 2 | S&F 30mm thick 2nd class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (with sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (b); supplied and fitted to chowkats complete all as specified and directed. |
| 3 | S&F 30mm thick factory made flush shutter, solid core construction with block board core and plywood face panels, commercial type on both sides kiln seasoned and chemically pressure treated complete all as specified and directed. |
| 4 | Taking down chowkat or frame with shutter (without taking off shutter from the frame) area not exc. 1.5sqm each, including cutting holes for removing the hold fast,making good disturbed surfaces and removing materials from site of work complete all as specified and directed. |
| 5 | Taking down chowkat or frame with shutter (without taking off shutter from the frame) exc. 1.5 sqm and n.exc 4 sqm each, including cutting holes for removing the hold fast, making good disturbed surfaces and removing materials from site of work complete all as specified and directed. |
| 6 | Taking down old unserviceable shutters of any description exc 1.00 but n.exe 2.00 Sqm each complete all as specified and directed. |
| 7 | S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heatm moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain/decorative colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement in the frame at site as per specification & drawing. etc complete all as specified and directed. |
| 8 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube in opening as per specification & drawingcomplete all as specified Make : Rajshree/Sintex/H2O solution.Note:-The door frame to be fixed to wall using 8 x 100 mm long anchor fasteners. |
| 9 | S&F Factory Made Solid PVC Moulded Door Shutter with particle board core , 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and directed. |
| 10 | S&F Solid PVC frame (Single Rebated) of size 60mm x 30mm made out of solid PVC foam with homogenous fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100 x 8 sheet metal CSK screws complete all as specified and as shown on drawing.(Note :- Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life)complete all as specified and directed. |
| 11 | S&F 100mm Brass barrel tower bolts, with cast or sheet barrel and rolled or cast bolts and fixed complete all as specified and directed. |
| 12 | S&F 150mm aluminium anodised barrel tower bolts of extruded sectioncomplete all as specified and directed. |
| 13 | S&F 250 mm long aluminium alloy, anodised,sliding door bolt with hasp,staple (bolt type) andfixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and direcetd. |
| 14 | S&F 100mm Butt hinges,medium weight, cold rolled mild steel,complete all as specified and directed. |
| 15 | S&F 100mm Butt hinges, cast brass,with mild steel hinge pin, bright polished and fixed, typeB-11 complete all as specified and as directed. |
| 16 | S&F 100mm Extruded brass handles,fabricated type polished complete all as specified and directed. |
| 17 | S&F 150mm size aluminium handle cast typecomplete all as specified and directed. |
| 18 | M&L for Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staplescomplete all as specified and directed. |
| 19 | S&F roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc conforming to Fe -410-W(Gde-E-250) quality-A. complete all as specified and directed. |
| 20 | S&F steel window with side hunge shutters including projecting type hinges with steel handle and steel peg stey, tower bolts etc. complete with glazing bars dovetailed or weldedcomplete all as specified and directed. |
| 21 | S&F steel window with side hunge shutters including projecting type hinges with steel handle and steel peg stey, tower bolts etc. complete without glazing bars dovetailed or weldedcomplete all as specified and directed. |
| 22 | M&Lfor 1.25mm thickpressed steel door frame of size 105mm x 60mm with one or more rebates including necessaryfixing lugs , hinges, lock strike plate etc complete all as specified and directed. |
| 23 | S&Ffor 1.25mm thick pressed steel frames125mm x 60mm for doors with one or more rebates includingnecessary fixing lugs, hinges, lock strike plate,etc.complete all as specified and directed. |
| 24 | M&L for anodised aluminium snap grid (SIZE-605x605MM) frame work for false ceiling complete all as specified and directed. |
| 25 | S&F Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed. |
| 26 | S&F Pre- painted coloured trapezoidal profiled Galvalume/ Zincalume sheet with min thickness 0.50mm TCT confirming to IS - 513(AZ-150 GSM, Al Zn allay metalic coating with 550 Mpa yield stress as per AS-1397) as in roof covering/cladding towall, fixed with self tapping screws colour exterior coat of silicon modified polyster/BHP x RW paint system 20 micron top coat applied over 5 micron primer and 5 micron polyster back coat applied over 5 micron primer , all fixed with galvanized self drilling self tapping fastner (12-14 x 55 with EPDM seals) complete all as specified and directed. |
| 27 | S&F Pre- painted coloured plain sheet Galvalume/ Zincalume sheet with min thickness 0.50mm TCT confirming to IS - 513(AZ-150 GSM, Al Zn allay metalic coating with 550 Mpa yield stress as per AS-1397) as in roof covering/cladding towall, fixed with self tapping screws colour exterior coat of silicon modified polyster/BHP/ XRW paint system 20 micron top coat applied over 5 micron primer and 5 micron polyster back coat applied over 5 micron primer , all fixed with galvanized self drilling self tapping fastner (12-14 x 55 with EPDM seals) complete all as specified and directed. |
| 28 | M&L for 40mm thick cement concrete type B-1, 1:2:4 (using 20 mm graded stone aggregates)as in flooring, rough finished for hard stading completeall as specified and directed. |
| 29 | M&L for rendering 10 mm thick in cement mortar 1:4 on concrete surface mixed with water proofing compound as per manufacture instruction etc complete all as specified anddirected. Notes : WPC shall be measured and paid seperately under respective item of this schedule. |
| 30 | Taking down existing un-sreviceable water proofing treatment from roof slab and slab and cleaning the roof by wire brush and removing WPT felt beyond the MOD premises etc. cement plaster on brick or stone walls, etc.complete all as specified and directed. |
| 31 | M&L for sheet glass, 4mm thick, ordinary quality and glazing with oil putty in squares n exc. 0.50 Sqm each panecomplete all as specified and directed. |
| 32 | M&L for 4mm thick, Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane complete all as specified and directed. |
| 33 | Hacking out old broken glass (any thickness size quality and discription) for metal frame exc 1.5 sqm including punching, drilling out old glazing pins / spring clips and providing new ones complete all as specified and directed. |
| 34 | M&Lfor preparation of untreated new wood/wooden surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint (1st grade quality) over a coat of pink primer complete all as specified and directed. |
| 35 | M&L for two coats of synthetic enamel paint over one coat of red oxideon new steel surfaces of any description over 10cm in width or girthincluding preparation of surfaces complete all as specified and directed. |
| 36 | Dismantling water tanks and removing to store exc 250 ltr but not exc 500 ltr capacity complete all as specified and directed |
| 37 | S&F rotational moulded PVC water storage tank 500 ltrs capacity conforming to IS-12701(1989) cylindrical vertical type double-layered with closed top (thereated) including inlet,outlet and wash out holes of approved make hoisted and fixed in position all as specified in SSR Part I etc completge all as specified and directed. |
| 38 | S&F in repair Ball brass valves, high pressure, with polyethene float and fly nut complete, screwed for GI pipe or brass ferrule of 20mm bore complete all as specified and directed. |
| 39 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 40 | Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings incl ridges, hips and valley gutter complete all as specified and directed. |
| 41 | Dimantling of Asbestos cement (corrugated,semi corrugated, etc.) sheets in roof coverings including ridges etc complete all as specified anddirected |
| 42 | Dismantlingwall and ceiling board( fiber, pulp, insulation, etc.) or insulation board/slab/ blankets, any thickness, including cover fillets complete all as specified and directed. |
| 43 | S&F 2nd class HW rail and style 35mm thick plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply the size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed. |
| 44 | S&F 4 mm thick Non asbestos fiber cementbuilding boards, fixed or laid /inserted totimber /GI /Aluminium frame-work with screws as in ceiling complete all as specified anddirected. |
| 45 | M&L for preparation of newly plastered surfaces of ceiling and applying one coat of oil bound distember over a coat of primer white or any tint over 1mm thick plaster of paris complete all as specified and directed. |
| 46 | M&L for surface preparationfree from frost, surface laitance and contamination free from loose aggregate or other sharp protrusions with fairly smooth finish for applicaion of water proof coating prime the surface with water including removal of all existing treatment, bituminious membrane, tarfelt.screed concrete etc from RCC roof slab complete all as specified and directed. |
| 47 | M&L for waterproofing coating by providing and applying Fostoc Brushbond Roof Guard of FOSROC or equivalent of SIKA/STP , a single component High build fibre Reinforced Acrylic Waterproofing render for roofing system applied by brush, at three coats at minimum dry film thickness of 1 mm, cured by reaction with atmospheric moisture to give a tough elastomeric waterproof membrane complete all as per manufacturer specification, specified and directed.Solid Content - 70%, Tensile strength ASTM D 412-1.10 Mpa, Elongation ASTM D12-100%, Resistance to ageing due to - 1000hours, UV radiation ASTM D4587 E - No Change, Rapid Chloride Penetration ASTM c 1202 - Very low, Pull off adhesion ASTM D541 - 0.92 Mpa, Resistance to Algae growth ASTM D 5589-97 - Passes, Zero rating, Permeability (mm) (BSEN 12390 part 8) -n 5.0, Water vapour transmission (ASTM E 96) - 6.0g/m2 h |
| 48 | M&L for providing and fixingDESIGNER PVC FALSE CEILING consisting of 600x600mm, 5mm (+0.25) thick plain ambossed PVC sheet of 600Kg/Cbm Density manufactured by ISO 9001-2008, certified company, used as panel insert in a frame work made using anodised aluminium T- section of sizes 1\"x1\" (25x25mm, 19 gauge or 1mm thick) in square pattern of grid sizes of 2\"x2\"(600x600mm). the aluminium frame work is supported from the ceiling with the help of \"J\" hook and GI wire/6mm MS rods of require sizes to maintain proper level etc. The aluminium framework is supported on side wall withthe use of aluminium L-section of size 1\"x1\"(25x25mm) angles etc. complete as specified by manufacturer & drawing and directed by Engr-in- Charge. |
| 49 | M&L for repairing of Cracks & Honeycomb Treatment by Injection Grouting by Identify the cracks and joints, shall be chased open into \"U\" groove shape.The surface of the groove shall be suitably prepared as require to apply the mortar. Apply a bond coat ofSBR Latex (of Make Fosroc Notobond or equivilant of SIKA/ STP and sealed with Shrinkage controlled, polymer modified, fiber reinforced cementitious repair mortar fixing PVC nozzle, injection grouting to be done with cement slurry admixed with expanding grout admixtureto be mixed @ 225 gm per bag of cement complete all as specified and directed . |
| 50 | M&L for bore packing to be done at pipe entries by forming properformwork and filling the gap with non-shrinkable cementitious grout conbextra GP2 of Make Fosroc or equivilant of SIKA/ STP and sealed with epoxy/polyester sealant complete all as specified and directed . |
| 51 | (Note : The Scope of Work contained in \"Sch of Credit\" amounting to Rs. 3,48,700.00. The Quoted sum shall be arrived at after deducting the amount of “Sch of Credit” from the total amount of the ‘BoQ’ |